Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023041215682Floor Panel · damagedCABIN FLOOR PANEL 231ZF HAS INSERT PUSHED IN ON IB FWD AREA. 8-88<[01] CABIN FLOOR PANEL 231ZF WILL BE REPLACED ON TTG8Q00JQJ6V;[02] FINAL INSPECTION; CABIN FLOOR PANEL 231ZF WILL BE REPLACED ON TTG8Q00JQJ6V.SDR SWAA2023041215688Floor Panel · crackedCABIN FLOOR PANEL 231ZF HAS CRACK ON AFT EDGE. 8-89<[01] RECEIVED NEW PANEL 231ZF (PO#2012626). PANEL WILL BE INSTALLED ON TTG8Q00H69CB.;[02] VERIFIED STEP#1.SDR SWAA2023041215715Stiffener · crackedSTIFFENER P/N 111A1308-16 IS CRACKED BS 663 RH VAPOR BARRIER RBL 25 W/L 148<[01] VERYFIED APPLICABILITY IAW SRM 53-10-10-1A-2 ALLOWABLE DAMAGE; FOUND OUT OF LIMITS IAW SRM 53-10-10-1A-2; 4(E);[02] REMOVED STIFFENER P/N 111A1308-16 IAW SRM 51-40-02-0G-0.<BR>UPDSDR SWAA2023041115672Vapor Barrier · crackedCRACK FOUND AT FASTENER HOLE AT LT VAPOR BARRIER UPPER SUPPORT ANGLE ;STA 663 ;LBL 5. CRACK FOUND AT FASTENER HOLE AT LT VAPOR BARRIER UPPER SUPPORT ANGLE STA 663 LBL 5.<[01] REPAIR LT VAPOR BARRIER UPPER SUPPORT ANGLE STA 663 LBL 5' AS PER SRM 57-10-10-2R-REPSDR SWAA2023041115673Angle · elongatedELONGATED HOLES (2 EA) FOUND AT RT VAPOR BARRIER UPPER ANGLE STA 663. RBL 22 AND RBL 47.<[01] C/W;[02] TASK C/W;[03] VERIFIED TASK C/W;[04] INSTALLED NEW ATTACHED UPPER ANGLE AT RIGHT VAPOR BARRIER STA 663. APPLIED SEALANT BMS 5-95 870C8. MIX TIME 2:00PM 3.16.SDR SWAA2023032316154Table · crackedTRAY TABLES AT SEAT ROWS 3C; 4C; 4A; 4F; 5B; 8B; 8E; 11C; 13C; 13A ; ARE CRACKED / SEPARATED.<[01] REPLACED TRAY TABLES AT SEAT ROWS 3C; 4C; 4A; 4F; 5B; 8B; 8E; 11C; 13C; 13A ; IAW CMM-25-21-42;[02] VERIFIED STEP 1; JOB COMPLETE; AUDIT C/WSDR SWAA2023031715845Light · inoperativeAFT SERVICE DOOR EXT EMERGENCY LIGHT INOP<[01] RELAMPED AFT SERVICE DOOR EXT EMERGENCY LIGHT PER AMM 33-51-04. OPS CHECK GOOD.SDR SWAA2023031615136Bulb · inoperative*C/R* EMERGENCY SIGN AFT OF R-2 DOOR HAS 1 BULB INOPERATIVE.<[01] RELAMPED EMERGENCY SIGN AFT OF R-2 DOOR AS PER B737 AMM 33-51-04-960-801. TEST OK.SDR SWAA2023031515433Sign · missingEMERGENCY EXIT LIGHT LENS COVER AFT OF L2 DOOR MISSING BOTTOM ATTACHMENT SCREW (MARKED)<[01] REPLACED L2 DOOR EXIT SIGN ASSEMBLY IAW AMM 33-51-01. OPS CHECK GOOD.;[02] CW INSPECTION PER AMM 33-51-01SDR SWAA2023042015791Vapor Barrier · crackedCUSTOMER REQUEST: L/H BS-663 VAPOR BARRIER CRACKED<[01] MEASUREMENTS;[02] CLEANED AND PREPARED CRACK DAMAGE AREAS FOR REPAIR; STOP DRILL ALL CRACKS ;PERFORMED DRY OUT; FOUND NO WATER AS PER B737 SRM 51-70-04-2R-10;[03] C/W;[04] VERIFIED ALL STEPS C/W;[05] VERISDR SWAA2023041715782Fitting · crackedDURING BUYBACK FOUND SUPPORT FITTING HAS 0.390' CRACK AT STR 16L BETWEEN STA 294.5 THRU 303.9 WL 208.1<[01] STARTED TO REMOVE FASTENERS AT SUPPORT FITTING LOCATED AT STR 16L BETWEEN STA 294.5 AND 303.9 WL 208.1 PER B737-700 SRM 51-40-02-0G-0;[02] REMOVED SUPPOSDR SWAA2023041715735Beam · corrodedCORROSION ON FLOOR BEAM 986.5 AT LEVEL STR 17L WL 208.1 LBL 46 AT GALLEY AREA 2023-185347<[01] INITIAL MEASURES OF CORROSION ARE L= 1.167? W=1.020? TOOL USED DIGITAL CALIPER P/N:500-197-30 S/N:A21042066 DUE DATE: 30-JUN-23.;[02] TOOL USED ULTRASONIC EQUIPMENT SDR SWAA2023041715736Beam · corrodedCORROSION ON FLOOR BEAM 986.5 AT LEVEL STR 17R WL 208.1 RBL 46 AT GALLEY AREA 2023-185342<[01] TOOL USED: ULTRASONIC THICKNESS GAGE P/N:45MG; S/N:221859911 DUE DATE: 07-NOV-23.;[02] TOOL USED: EDDY CURRENT EQUIPMENT. P/N: NORTEC 600D. S/N: 220272512. DUE DATE:SDR SWAA2023041715732Intercostal · corrodedCORROSION ON FLOOR STRUCTURE INTERCOSTAL BRAKE PANEL LOCATED BTW BS 312 TO BS 328 WL 208.1 RBL 10 AT FWD GALLEY AREA 2023-185317<[01] REPLACED FLOOR STRUCTURE INTERCOSTAL BRAKE PANEL LOCATED BTW BS 312 TO BS 328 WL 208.1 RBL 10 AT FWD GALLEY AREA IAW B737-700 SDR SWAA2023041715780Skin · bulgedLT WING LOWER MID SPAN T/E PANEL ASSEMBLY 561CB INNER SKIN SHOWS FASTENER HOLES BULGING AS MARKED. 124-014<[01] REPAIRED DAMAGED AREA AT LT WING LOWER MID SPAN T/E PANEL ASSEMBLY 561CB INNER SKIN. REF B737 SRM 51-70-04-2R-9 PARAGRAPH 4. MATERIAL USED GLASS FABSDR SWAA2023041715731Plate · crackedCRACK CORRUGATED PLATE TRAILING EDGE LOCATED ON ORSS 261 LT WING 2023-185292<[01] FAULT RESOLVER IN FAULT TTG8Q00JWHBK DUE TO DISCREPANCY IS DUPLICATED;[02] FAULT RESOLVER IN FAULT TTG8Q00JWHBK DUE TO DISCREPANCY IS DUPLICATEDSDR SWAA2023041715730Angle · corrodedCORROSION ANGLE OUTBOARD TRAILING EDGE LOCATED BTW SPOILER 3 AND SPOILER 4 ORSS 354 LT WING 2023-185285<[01] REPLACED ANGLE OUTBOARD TRAILING EDGE LOCATED BTW SPOILER 3 AND SPOILER 4 ORSS 354 LT WING I.A.W B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG#SDR SWAA2023041115151Angle · corrodedCORROSION INNER CHORD LOCATED AT LEVEL STR 17L BS 303.9 LBL 55 WL 208.1 AT FWD GALLEY AREA 2023-180925<[01] TOOL USED ULTRASONIC THICKNESS INSTRUMENT P/N 45MG S/N 130064101 DUE DATE 12-OCT-23;[02] REPLACED INNER CHORD LOCATED AT LEVEL STR 17L BS 303.9 LBL 55 WSDR SWAA2023041115181Door · corrodedLOWER FUSELAGE SERVICE DOOR 145AL INTERNAL EVIDENCE OF CORROSION AROUND BONDING WIRE<[01] REMOVED AND REPLACED LOWER FUSELAGE SERVICE DOOR 145AL REF AMM 52-49-07-400-801;[02] VERIFIED REPLACEMENT OF THE LOWER FUSELAGE SERVICE DOOR 145AL REF AMM 52-49-07-400-80SDR SWAA2023041115179Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 380-400 AND LBL 13<[01] C/W;[02] C/W;[03] VERIFIED REPLACEMENT OF CABIN FLOOR INTERCOSTAL BETWEEN STA. 380-400 AND LBL 13SDR SWAA2023041115178Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 380-400 AND RBL 39<[01] REMOVED AND REPLACED NEW INTERCOSTAL AT MAIN CABIN STA 380-400 RBL 39' AS PER SRM 51-40-02 AND DWG 143A5400;[02] VERIFIED STEP 1;[03] TASK C/W;[04] VERIFIED STEP 1SDR SWAA2023041115182Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 380-400 AND RBL 9<[01] INSTALLED NEW INTERCOSTAL BETWEEN STA 380-400 AT RBL 9 REF 51-40-02-0G-0 AND DWG 145A5400;[02] C/W;[03] TASK C/WSDR SWAA2023041115180Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 277-291.5 AND BL0<[01] REMOVED AND REPLACED INTERCOSTAL AT MAIN CABIN BETWEEN STA 277 AND STA 291.5 BL 0 REF SRM 51-40-02-0G-0 AND DWG #141A5400.;[02] VERIFIED STEP 1SDR SWAA2023032415376Bracket · crackedFOUND PANEL SUPPORT BRACKET CRACKED AT STA 500L BEHIND PANEL 191AR<[01] REMOVED PANEL 191AR FOR ACCESS TO BRACKET REF B737-700 SRM 51-40-02-0G-0;[02] REMOVED R/H SUPPORT BRACKED AT STA 500L IN REF TO B737 AMM 51-40-02-0G-0;[03] LOCATED AND DRILLED NEW SUPPORT SDR SWAA2023031515976Slide · out of adjustFWD SERVICE DOOR NEEDS REPACKED<[01] R&R FS DOOR ESCAPE SLIDE PER MT 725-61-06.SDR SWAA2023031515977Cover · brokenREF PREVIOUS LP#2119565 - FORWARD SERVICE DOOR SLIDE NEEDS REPACKED<[01] REMOVED FWD SVC DOOR SLIDE ASSY REF MT 725-61-06 FOUND SLIDE COVER CLASP BROKEN SEE LP#2119565 FOR FINAL CORRECTIVE ACTIONSDR SWAA2023031515995Sign · brokenOVER WING EXIT SIGN BROKEN.<[01] SECURED OVER WING EXIT SIGN PER AMM 33-51-00. SIGN WORKS NORMAL.SDR SWAA2023031515960Strap · brokenA STRAP ON THE OVERWING EXIT; CAPTAINS SIDE; APPEARS BROKEN.<[01] RE-SECURED L/H OVERWING EMERGENCY EXIT PULL STRAP HOUSING IAW S.I.P.SDR SWAA2023041815611Stringer · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS706 S-6R.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM. PART DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED STRINGER CLIP AT PASSENGER CABIN BS706 S-6R IAW SRM 51-40-02;[03] RSDR SWAA2023041715655Tie · crackedCRACK ON TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA 2023-185225<[01] REPLACED TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A1110 SHEET 18 REV-;[02] CORRECTED STEP 1<BR>REPLACED TIE CLISDR SWAA2023041715778Floor Panel · delaminatedPANEL 232QF DELAMINATED.<[01] REPLACED MAIN CABIN FLOOR PANEL #232QF REF. B737-700 AMM 53-21-00-400-801. FLOOR PANEL #232QF WILL BE INSTALL ON FAULT #TTG8Q00HHHG4;[02] VERIFIED.SDR SWAA2023041715771Bracket · crackedFWD CARGO STA 500C LBL 23.5 S-26L WL 156 INTERCOSTAL SUPPORT BRACKET ON AFT SIDE OF FRAME IS CRACKED 124-006<[01] REMOVED AND REPLACED INTERCOSTAL SUPPORT BRACKET AT FWD CARGO STA 500C LBL 23.5 S-26L WL 156 PER B737-700 SRM 51-40-02-0G-0 & DRAWING NO. 143A7505SDR SWAA2023041715779Angle · crackedINTERCOSTAL UPPER CHORD (ANGLE) AT BETWEEN STA 380 AND STA 400 BL 0; HAS CRACKS AT FASTENERS HOLES;<[01] REMOVED AND REPLACED INTERCOSTAL UPPER CHORD (ANGLE) BETWEEN STA 380 AND STA 400 BL 0 PER B737-700 SRM 51-40-02-0G-0 AND DRWG #143A5400.;[02] VERIFIED STEPSDR SWAA2023041715658Intercostal · corrodedCORROSION ON FLOOR STRUCTURE INTERCOSTAL BRAKE PANEL LOCATED BTW BS 294.5 TO BS 312 AT FWD GALLEY AREA 2023-185239<[01] TOOL USED: ULTRASONIC THICKNESS GAUGE; PN: 45MG; SN: 221861811; DUE DATE: 08-NOV-23;[02] REPLACED NEW INTERCOSTAL BRAKE PANEL LOCATED BTW BSSDR SWAA2023041715723Panel · crackedCRACK ACCESS PANEL 661CB HOLES AT RT WING 2023-185255<[01] TOOL USED: CALIPER P/N:500-197-30 S/N:B20189416 DUE DATE:19-DEC-23;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18175478 DUE DATE: 24/SEP/23.;[03] TOOL USED: SCALE P/N: SPX621 S/N:8340225441 DUE DASDR SWAA2023041715724Panel · crackedCRACK ACCESS PANEL 661BB AROUND HOLE AT RT WING 2023-185257<[01] TOOL USED: CALIPER P/N:500-197-30; S/N:B2018941; DUE DATE:19-DEC-23.;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18175478 DUE DATE: 24/SEP/23.;[03] TOOL USED: SCALE P/N: SPX621 S/N:834022544SDR SWAA2023041715725Panel · crackedCRACK ACCESS PANEL 661AB AROUND HOLE AT RT WING 2023-185259<[01] TOOL USED: CALIPER P/N:500-197-30; S/N:B20189416; DUE DATE:19-DEC-23.;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18175478 DUE DATE: 24/SEP/23;[03] TOOL USED: CALIPER P/N: 500-193-30 S/N: 00SDR SWAA2023041715632Panel · crackedCRACK ACCESS PANEL 561CB TRAILING EDGE AROUND HOLES LT WING 2023-185210<[01] TOOL USED: CALIPER P/N:500-197-30 S/N:B20189416 DUE DATE: 19-DEC-23;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18175478 DUE DATE: 24/SEP/23;[03] TOOL USED: SCALE P/N: SPX621 S/NSDR SWAA2023041715649Panel · crackedCRACK ACCESS PANEL 561AB TRAILING EDGE AROUND HOLES LT WING 2023-185218<[01] TOOL USED: CALIPER P/N:500-197-30 S/N:B20189416 DUE DATE:19-DEC-23;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18175478 DUE DATE: 24/SEP/23.;[03] TOOL USED: SCALE P/N: SPX621 S/NSDR SWAA2023041715654Panel · crackedCRACK ACCESS PANEL 561BB TRAILING EDGE AROUND HOLES LT WING 2023-185220<[01] TOOL USED: CALIPER PN: 500-197-30; SN: B20189416; DUE DATE: 19-DEC-23;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18175478 DUE DATE: 24/SEP/23.;[03] TOOL USED: SCALE P/N: SPX621 SDR SWAA2023041415659Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED BS 294.5 AT LEVEL STR 17R FWD GALLEY AREA 2023-185241<[01] FAULT RESOLVED ON OTHER FAULT; SEE FAULT TTG8Q00JJ51Q;[02] FAULT RESOLVED ON OTHER FAULT; SEE FAULT TTG8Q00JJ51QSDR SWAA2023041415664Intercostal · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 344 TO BS 360 RBL 52 AT FWD GALLEY AREA 2023-185254<[01] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 344 TO BS 360 RBL 52 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND SDR SWAA2023041415634Intercostal · crackedCRACK ON INTERCOSTAL LOCATED BTW BS 303.9 TO BS 294.5 AT LEVEL STR 16L AT FWD GALLEY AREA 2023-185222<[01] REPLACED INTERCOSTAL; LOCATED BTW BS 303.9 TO BS 294.5 AT LEVEL STR 16L AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02 AND DWG: 141A8180 REV: C. SEE INDISDR SWAA2023041415660Stub Frame · crackedCRACK ON STUD FRAME LOCATED BS 294.5 AT LEVEL STR 17R RBL 54 FWD GALLEY AREA 2023-185243<[01] ET EQUIPMENT P/N: NORTEC 600D; S/N: 220272712; DUE DATE: 17-DEC-23;[02] ET EQUIPMENT P/N: NORTEC 600D; S/N: 220272712; DUE DATE: 17-DEC-23;[03] PERFORMED PERMANENT RESDR SWAA2023041415656Intercostal · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 270 TO BS 277 RBL 3 AT FWD GALLEY AREA 2023-185229<[01] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 270 TO BS 277 RBL 3 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND SDR SWAA2023041415657Web · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 RBL 32 AT FWD GALLEY AREA 2023-185236<[01] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 RBL 32 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02 ITEM 9 AND DWG #141A541SDR SWAA2023041415661Intercostal · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 344 TO BS 360 LBL 14 AT FWD GALLEY AREA 2023-185250<[01] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 344 TO BS 360 LBL 14 AT FWD GALLEY AREA IAW B737-700 SRM-51-40-02 AND DWG-141A5400 REV:- SESDR SWAA2023041415662Intercostal · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 344 TO BS 360 RBL 33 AT FWD GALLEY AREA 2023-185253<[01] REPLACED WEB INTERCOSTAL AND FASTENERS ON FLOOR STRUCTURE LOCATED BTW BS 344 TO BS 360 RBL 33 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02 ITEM 9SDR SWAA2023041415636Intercostal · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA 2023-185226<[01] REPLACED WEB INTERCOSTAL LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02; 51-40-02 AND DWG 141A5400 REV-.SEE ISDR SWAA2023041415653Intercostal · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 328 TO BS 344 LBL 46.5 AT FWD GALLEY AREA 2023-185219<[01] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 328 TO BS 344 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02;51-40-02 AND DWG 141A
Back to Boeing 737-7H4