Boeing 737-7H4

Service difficulty reports · 96,125

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '7377H4'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWAA2023041415637Intercostal · crackedCRACK ON WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 RBL 2 AT FWD GALLEY AREA 2023-185233<[01] REPLACED WEB INTERCOSTAL LOCATED ON FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 RBL 2 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141AMar 11, 2023 · N221WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041215201Panel · brokenPANEL 242CF CORNER BROKEN. 8-80<[01] RECEIVED NEW PANEL 242CF (PO#2012626). PANEL WILL BE INSTALLED ON TTG8Q00H6975.;[02] FINAL INSPECTION; NEW PANEL RECEIVED. PANEL WILL BE INSTALLED ON TTG8Q00H6975.Mar 11, 2023 · N443WN · Boeing 7377H4 · Fuselage Floor PanelSDR SWAA2023041215203Panel · brokenPANEL 242DF CORNER BROKEN. 8-79<[01] RECEIVED NEW PANEL 242DF INSTALLATION WILL BE ACCOMPLISHED ON TTG8Q00H6971;[02] FINAL INSPECTION; RECEIVED NEW PANEL 242DF INSTALLATION WILL BE ACCOMPLISHED ON TTG8Q00H6971.Mar 11, 2023 · N443WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041115150Web · elongatedELONGATED HOLE WEB LOCATED AT BS 294.5 RBL 54 AT FWD GALLEY AREA 2023-180921<[01] REPLACED WEB LOCATED AT BS 294.5 RBL 54 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 DWG 141A8310 REV. A SEE INDIVIDUAL SIGN OFF BELOW.;[02] TASK COMPLETED ; Mar 11, 2023 · N280WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023032115803Battery Pack · inoperativeL2 DOOR EMERGENCY EXIT LIGHTS ARE INOP<[01] REPLACED EMERGENCY BATTERY PACK AT L2 DOOR IAW AMM 33-51-06-960-805. OPS CHECK GOOD;[02] VERIFIED STEP 1<BR>AUDIT CWMar 11, 2023 · N235WN · Boeing 7377H4 · Emergency LightingSDR SWAA2023031615132Light · inoperativeR/H AFTER WING EXTERIOR EMERGENCY LIGHT INOPERATIVE.<[01] RELAMPED R/H AFTER WING EXTERIOR EMERGENCY LIGHT PER REF AMM 33-51-04-960-801. PERFORMED OPS CHECK AND FOUND NORMAL.;[02] VERIFIED / INSPECTED LITE .IS OPERATIONAL ;Mar 11, 2023 · N216WR · Boeing 7377H4 · Emergency LightingSDR SWAA2023031515898Holder · looseFORWARD SERVICE DOOR GIRTH BAR HOOKS DO NOT SECURE THE BAR SUFFICIENTLY<[01] RECLAMPED THE SERVICE DOOR GIRT BAR HOLDERS TO SECURE THE GIRT BAR TIGHTER REF SIPMar 11, 2023 · N497WN · Boeing 7377H4 · Escape SlideSDR SWAA2023031515913Slide · looseAFT ENTRY DOOR SLIDE FELL OUT<[01] REINSTALLED AFT ENTRY DOOR SLIDE IAW AMM 25-66-01Mar 11, 2023 · N948WN · Boeing 7377H4 · Escape SlideSDR SWAA2023031414893Trim Tab · faultyAFTER TAKE OFF STAB OUT OF TRIM ANNUNCIATOR ILLUMINATED WITH AUTO PILOT ENGAGED. THEN EXTINGIUSHED AFTER 10 SECONDS; LATER ON CLIMB OUT STAB TRIM WILL NOT TRIM NOSE UP.<[01] TROUBLE SHOT PER FIM 27-41 TASK 803. PROBLEM FOUND TO BE INTERMITTENT. ELECTRIC STAB TMar 11, 2023 · N485WN · Boeing 7377H4 · Stabilizer Control SystemSDR SWAA2023041814992Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS277+14 BL0 WL208.<[01] CRACKED INTERCOSTAL AT FWD CABIN BS 277+14 BL 0 WL 208.1 FOURD 100% OUT OF LIMITS IAW SRM 5-10-02;[02] REMOVED INTERCOSTAL FROM BS277-BS294 BL 0 WL 208.1 IAW SRM 51-40-02;[03] VERIFIED CORRECTIVE ACTIONMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041814996Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS312+5 RBL31 WL208.<[01] CRACKED INTERCOSTAL AT FWD CABIN BS312+5 RBL 31; WL 208.1 FOUND 100% OUT OF LIMITS IAW SRM 51-10-02;[02] REMOVED INTERCOSTAL FROM BS312-BS344 RBL 31 IAW SRM 51-40-02;[03] VERIFIED CORRECTIVE ACTION 1;[Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041814998Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+6 BL0 WL208.<[01] VERIFIED APPLICABILITY OF SRM 53-10-51-1A-1 ALLOWABLE DAMAGE 1 - SECTION 41 FLOOR STRUCTURE;[02] ACCOMPLISHED EVALUATION OF CRACK ON INTERCOSTAL AT FWD WET AREA PASSENGER CABIN FLOOR STRUCTURE STA344+6''Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041814979Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+6 RBL51 WL208.<[01] REQUEST NDI TO VERIFY DAMAGE.;[02] REMOVED INTERCOSTAL AT FWD CABIN BS 344-360 RBL 51 WL 208 IAW SRM 51-40-02;[03] AFTER INTERCOSTAL REMOVED CRACKS ARE NOTED ON FASTENER HOLES AND NO DATA FOUND ON SRM Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815003Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+6 RBL32 WL208.<[01] REQUEST NDI TO VERIFY DAMAGE.;[02] REMOVED INTERCOSTAL AT BS 344 TO 360 RBL32 PER SRM 51-40-02-0G-0;[03] AFTER INTERCOSTAL REMOVED CRACKS ARE NOTED ON FASTENER HOLES AND NO DATA FOUND ON SRM 53-10-51-1Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041814991Attach Angle · crackedCRACKED ATTACH ANGLE AT FWD CABIN BS294 RBL53 WL208.<[01] REQUEST NDI TO VERIFY DAMAGE.;[02] UNABLE TO PERFORM HFEC INSPECTION DUE TO AREA NOT BEING SUFFICIENTLY CLEANED.;[03] HFEC INSPECTED SUSPECTED CRACKED AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041815001Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+6 LBL11 WL208.<[01] REQUEST NDI TO VERIFY DAMAGE.[11] 7075-T6 CLAD SHEET#0.080 LOT#1492623-1.<BR>IAW SRM 53-10-51-2R-10 PART 4.H TO 4.L FIG.205; REFER TO EA 23-153-01114-WIP1 STEPS 10-13; SRM 51-40-05-0G-0.;[12] UPDATE STMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815005Fitting · bulgedACCESS RH BS 663 VAPOR BARRIER BULKING FITTINGS FOR REPAIR.<[01] REMOVED 8 EA. BULKHEAD FITTINGS FROM RH BS 663 VAPOR BARRIER PER AMM 20-10-51-000-801.;[02] REINSTALLED 8 EA. BULKHEAD FITTINGS ONTO RH BS 663 VAPOR BARRIER IAW AMM 20-10-51-400-804.<BR>TORQUE WRMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041815569Stringer · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS767 S-6L.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM. PART DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED ON STRINGER CLIP AT PASSENGER CABIN BS767 S-6L IAW SRM 51-40-02;[03Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Longeron/StringerSDR SWAA2023041815570Stringer · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS747 S-6L.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM. PART DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9;[02] REMOVED STRINGER CLIP ON PASSENGER CABIN BS 747 S-6L IAW SRM 51-40-02;[03] RMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Longeron/StringerSDR SWAA2023041815571Stringer · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS727B S-9L.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM. PART DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED STRINGER CLIP AT PASSENGER CABIN ON BS727B S-9L IAW SRM 51-40-02;[Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Longeron/StringerSDR SWAA2023041815572Stringer · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS727E S-5L.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM. PART DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED STRINGER CLIP AT PASSENGER CABIN BS727E S-5L IAW SRM 51-40-02;[03]Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Longeron/StringerSDR SWAA2023041815573Stringer · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS727E S-6L.<[01] NOT ALLOWABLE DAMAGE FOUND ON SRM. PART DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED STRINGER CLIP AT PASSENGER CABIN BS727E S-6L IAW SRM 51-40-02;[03]Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Longeron/StringerSDR SWAA2023041814655Panel · pulledPASSENGER CABIN FLOOR PANEL 231XF UPPER SURFACE HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 231XF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1508290-1; INSERTS INSTALLED USING BMS5-107 LOT#AK2KP8383K THEN CURED USING HEAT LAMPS AMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Floor PanelSDR SWAA2023041814659Floorboard · pulledPASSENGER CABIN FLOOR PANEL 241DF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] FABRICATED NEW FLOOR BOARD 241DF FROM BMS 4-23 TY2 LOT#1492708-1. INSTALLED INSERTS USING BMS 5-107 LOT#AK2KP8383K AND CURED INSERTS USING HEAT LAMP AND THERMOMETER ID:ATS2Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Floor BeamSDR SWAA2023041815584Angle · crackedCRACK ON FWD CARGO BAY FRAME TO BAFFLE ATTACH ANGLE AT LBL 24 BS 400+1 WL 155.<[01] VERIFIED SRM 51-10-02 PARAG 9;IS APPLICABLE BY REPLACEMENT.;[02] PRIOR TO REMOVAL ;FOUND PART HAS NOT SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT;IAW SRM 51-10-02 PARAGMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Plate/SkinSDR SWAA2023041815586Gusset · crackedCRACK ON FWD CARGO BAY GUSSET AT BS 500D STRINGER 19L.<[01] PRIOR TO REMOVAL;FOUND PART TO HAVE NO SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT;PER SRM 51-10-02 STEP 9.;[02] REMOVED ON FWD CARGO BAY GUSSET AT BS 500D STR 19L IAW SRM 51-40-02;[03] RECEIVMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Plate/SkinSDR SWAA2023041815604Gusset · crackedCRACK ON FWD CARGO BAY GUSSET AT BS 500D STRINGER 19R.<[01] PRIOR TO REMOVAL;FOUND PART TO HAVE NO SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT;PER SRM 51-10-02 STEP 9.;[02] REMOVED ON FWD CARGO BAY GUSSET AT BS 500D STR 19R IAW SRM 51-40-02;[03] RECEIVMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Plate/SkinSDR SWAA2023041815587Gusset · crackedCRACK ON FWD CARGO BAY GUSSET AT BS 500D STRINGER 21R.<[01] PRIOR TO REMOVAL;FOUND PART TO HAVE NO SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT;PER SRM 51-10-02 STEP 9.;[02] REMOVED ON FWD CARGO BAY GUSSET AT BS 500D STR 21 IAW SRM 51-40-02;[03] REMOVEDMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Plate/SkinSDR SWAA2023041815575Stringer · crackedAFT CARGO BAY - STRINGER CLIP HAS A CRACK BS 747 STR 26L.<[01] REMOVED STRINGER CLIP IN AFT CARGO BAY BS747 STR 26L IAW SRM 51-40-02.;[02] THIS PART DOES NOT ALLOWABLE DAMAGE WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9;[03] VERIFIED CORRECTIMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Longeron/StringerSDR SWAA2023041814662Floorbeam · corrodedCORROSION ON STA 986.5 FLOOR BEAM UPPER FLANGE AT RBL 46; 43.5; AND 40.5; WL 208.1 CORROSION ON STA 986.5 FLOOR BEAM UPPER FLANGE AT RBL 35.5 39.5 AND 43 WL 208.1 [TTG8Q00JF8G0]<[01] SRM 53-70-51-0I-1 IDENTIFICATION AND SRM 53-70-51-1A-1 ALLOWABLE DAMAGE ARE AMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Floor BeamSDR SWAA2023041815606Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727C+10 TO BS 767 (MARKED)<[01] VERIFIED APPLICABILITY SRM 53-60-53-01-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>STEPS 1-3 COMPLETED.;[02] VERIFIEDMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815607Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727 TO BS 727D+10 (MARKED)<[01] VERIFIED APPLICABILITY SRM 53-60-53-01-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>STEPS 1-3 COMPLETED.;[02] VERIFIEDMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815608Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727D+10 TO BS 847 (MARKED)<[01] VERIFIED APPLICABILITY SRM 53-60-53-01-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>STEPS 1-3 COMPLETED.;[02] VERIFIEDMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041814988Floorbeam · corrodedCORROSION ON LATERAL BEAM AT FWD CABIN BS270 LBL10 WL208.<[01] REMOVED 1 EA HILOK AT LBL 10 BS 270WL 208.1 IAW SRM 51-40-02;[02] REMOVED CORROSION ON LATEAL BEAM AT FWD CABIN BS 270 LBL 10 WL 208 IN 1.1'LX 0.8'W AREA IAW SRM 51-10-02;[03] VERIFIED CORRECTIVE AMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Floor BeamSDR SWAA2023041814989Support · corrodedCORROSION ON FLOOR SUPPORT AT FWD CABIN BS270+6 LBL11 WL208.<[01] EVALUATED DAMAGE ON FLOOR SUPPORT AT FWD CABIN BS270+6 LBL11 WL208; FOUND TO BE OUT OF LIMITS; DUE NOT LIMITS IN SRM PART WILL BE REPAIRABLE BY REPLACEMENT; IAW SRM 51-10-02-0G-0;[02] REMOVED FLMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041814990Floorbeam · corrodedCORROSION ON FLOOR BEAM AT FWD CABIN BS328 RBL328 RBL10; 20;23;31 WL208.<[01] UPDATED PARTIAL STEPS 1-718] FABRICATED -5 ANGLE FROM BAC 1490-2651#7075T6 CLAD LOT#1483887-1; -4 (2EA) SHIMS AND -6 FILLER FROM 7075T6#0.020' CLAD LOT#1516841-1. TREATED IAW SRM 53-Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, Floor BeamSDR SWAA2023041814665Strap · corrodedCORROSION ON PAX CABIN FLOOR TENSION STRAP AT STA 1016 TO 1016+2; RBL 3; WL 208.1<[01] NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM FOR THIS ITEM. THE STRUCTURAL ITEMS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT PER SRM 51-10-02 PARAGRAPH 9;[02] RMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041814661Strap · corrodedCORROSION ON AFT PAX CABIN FLOOR STRUCTURE TENSION STRAP FROM STA 1016 TO 1016+10; LBL 3; WL 208.1.<[01] NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM FOR THIS ITEM. THE STRUCTURAL ITEMS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT PER SRM 51-10-02 Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Structure (General)SDR SWAA2023041815591Support · corrodedAFT CARGO - AFT BULKHEAD LOWER FLOOR SUPPORT HAS CORROSION BS 947 LBL 3; LBL 4.5; LBL 8; LBL12.5; RBL 2; RBL 5.5; RBL 7.75; RBL 8.5; RBL 10; RBL 11.75; RBL 14; RBL 15.25.<[01] REMOVED AFT CARGO BAY AFT LOWER BULKHEAD SUPPORT AT BS 947 BRACKET P/N (149A8118-29)Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815574Web · corrodedAFT CARGO BAY - CORROSION ON THRESHOLD WEB AT RBL 25.75 BS 787+14; BS 787+18; BS 807+1; BS 807+3; BS 807+5; BS 807+7.5; BS 807+10; BS 807+12; BS 807+14; BS 807+16; BS 807+18; BS 827+1; BS 827+3.5.<[01] COMPLETED STEPS 1-13 VERIFIED APPLICABILITY SRM#53-60-15-0Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041815594Rail · corrodedAFT CARGO BAY - RAIL HAS CORROSION LBL 3 BS 727+9.5; BS 727+12.75; BS 767+5.<[01] VERIFIED APLICABILITY SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE;[02] COMPLETED STEPS 1-3.<BR><BR>OK TO APPLY CHEMICAL CONVERSION COATING ANDMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815595Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500B+10-500D WL 158.<[01] FLOOR TO SIDEWALL SUPPORT SHOW PREVIOUS REINFORCING REPAIR & NOT HAS ALLOWABLE DAMAGE IN SRM AT LBL 24 BS 500B+10' TO BS 500D WL 156.5 MUST BE REPAIR BMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815577Rail · corrodedAFT CARGO BAY - RAIL HAS CORROSION BS 767+5 LBL 7.75; LBL 12; RBL 3.<[01] VERIFIED APLICABILITY SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE;[02] COMPLETED STEPS 1-3.<BR><BR>OK TO APPLY CHEMICAL CONVERSION COATING AND PRIMER.Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Structure (General)SDR SWAA2023041815576Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500-500B WL 158.<[01] FLOOR TO SIDEWALL SUPPORT SHOW PREVIOUS REINFORCING REPAIR & NOT HAS ALLOWABLE DAMAGE IN SRM AT LBL 24 BS 500 TO BS 500B WL 156.5 MUST BE REPAIR BY REPLACEMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815578Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 420-480 WL 157.<[01] PARTIAL STEPS # 1-3.;[02] PARTIAL UPDATES STEPS 1 - 3;[03] RECEIVED EXTRUSION P/N BAC1496-444 LOT. 1520195-1. LOCATED AND DRILLED (2EA) EXTRUSION (FORMED CHMar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815599Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 400-420 WL 157.<[01] VERIFIED APPLICABILITY FOR SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2.;[02] REMOVED CORROSION ON FCB TO SIDEWALL SUPPORT AT RBL24;BS400-420;WL157.MEASURE:L=.9';W=Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815600Shield · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FWD DOOR SHIELD AT RBL 24 BS 420-440 WL 157.<[01] VERIFIED SRM 51-10-02 PARAG 9. IS APPLICABLE FOR REPAIRABLE BY REPLACEMENT.;[02] CORROSION ON FWD CARGO BAY FWD DOOR SHIELD LOCATED BETWEEN BS 420-BS 440 RBL24.FOUND Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815581Web · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY THRESHOLD AT RBL 23-29 BS 440-480+11 WL 157.<[01] VERIFIED APPLICABILITY OF SRM 53-30-15-1A-1 ALLOWABLE DAMAGE 1;AND SRM 53-30-15-0I-1 IDENTIFICATION 1.;[02] REMOVED CORROSION FROM FWD CARGO;THRESHOLD WEB AT RBL23-29Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Main, StructureSDR SWAA2023041815601Shield · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY AFT DOOR SHIELD AT RBL 24 BS 480+13-500A WL 157.<[01] VERIFIED SRM 51-10-02 PARAG 9.IS APPLICABLE FOR REPAIRABLE BY REPLACEMENT.;[02] CORROSION ON FWD CARGO BAY AFT DOOR SHIELD;LOCATED BETWEEN BS 492.4-BS 500A;FOUND Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous StructureSDR SWAA2023041815582Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500A-500D WL 157.<[01] VERIFIED APPLICABILITY FOR SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2.;[02] REMOVED CORROSION ON FCB TO SIDEWALL SUPPORT AT RBL24;BS500A-500D;WL157.MEASURE:L=.5Mar 10, 2023 · N281WN · Boeing 7377H4 · Fuselage Miscellaneous Structure
Back to Boeing 737-7H4