Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023030103315Floor Panel · pulledDOT A24-11 CENTER CABIN FLOOR PANEL 232RF HAS PULLED COMPOSITE FIBERS ON UPPER SURFACE.<[01] WORK ACCOMPLISHED ON W.O.#TTG8Q00HU0UH;[02] VERIFIED STEP 1SDR SWAA2023030103316Floor Panel · pulledDOT A24-12 CENTER CABIN FLOOR PANEL 231YF HAS PULLED COMPOSITE FIBERS ON UPPER SURFACE.<[01] EVALUATED AND FOUND MULTIPLE PLIES ON UPPER SURFACE FULL LENGTH OF BOARD. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANESDR SWAA2023030103307Barrier · crackedR/H VAPOR BARRIER HAVE A CRACK AT RBL45 WL165<[01] EVALUATED R/H VAPOR BARRIER AND FOUND A 3' CRACK AT RBL 45. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 57-10-10-2R-2 PAR 1A& NOTE. CLEAN AND PREP FOR REPAIR. IAW B737-700 SRM 51-70-04-2R-10 PAR 4A-C. VERIFY MATESDR SWAA2023030103304Angle · crackedLEADING EDGE ATTACH ANGLE FOR WING TO BODY PANEL 191AR IS CRACKED<[01] REMOVED CRACKED ANGLE IAW SRM 51-40-02-0G-00.;[02] DRILLED NEW ANGLE IAW SRM 51-40-02-0G-00 AND BOEING DRAWING 116A3110.;[03] VERIFIED ACTIONS 1 AND 2;[04] VERIFIED STEPS AND OK TO INSTALL;SDR SWAA2023030103305Angle · crackedR/H STA 663 CENTER TANK LOWER ANGLE HAVE A CRACK AT RBL 43 WL167<[01] VERIFIED ITEM 2 OF STEP 3;[02] VERIFIED ITEM 4 OF STEP 3;[03] VERIFIED ITEM 2 OF STEPS 1 AND 7;[04] JOB COMPLETE; AUDIT C/WSDR SWAA2023030103306Angle · crackedL/H STA663 CENTER TANL LOWER ANGLE HAVE A CRACK AT LBL43 WL167<[01] VERIFIED ITEM 2 STEP 7;[02] VERIFIED ITEM 5 OF STEP 5;[03] JOB COMPLETE; AUDIT C/WSDR SWAA2023030103320Angle · crackedCRACK FOUND ON LOWER ATTACH ANGLE(WL 193) AT STA 663 FROM APPROX RBL 45-48<[01] REMOVED THE REPAIR THAT WAS ORIGINALLY INSTALLED PER NRC X381997 AND INSTALLED A NEW REPAIR PER EA 23-157-00522. INSPECTION THRESHOLD DEFINED IN EA 23-157-00522-DTI;[02] VERIFIED SSDR SWAA2023021702571Support Bracket · cracked192E RH FWD HANGAR SUPPORT BRACKET CRACKED.<[01] REMOVED AND REPLACED SUPPORT BRACKET PER SRM 51-40-02SDR SWAA2023021602559Seal · crackedLH HORIZONTAL STABILIZER UPPER SLIDING SEAL IS CRACKED<[01] INSTALLED PINS TO ATTACH LH HORIZONTAL STABILIZER UPPER SLIDING SEAL TO LINK ASSEMBLY PER AMM 53-31-31. OPS CHECK REQUIRED.;[02] REMOVED AND REPLACED LH HORIZONTAL STABILIZER UPPER SLIDING SEAL ASSEMBSDR SWAA2023021602560Seal · crackedRH HORIZONTAL STABILIZER UPPER SLIDING SEAL IS CRACKED. R/R RIGHT HAND UPPER SLIDING SEAL PER AMM 53-31-31SDR SWAA2023021602573Track · brokenRH HORIZONTAL STABILIZER UPPER SLIDING SEAL FWD GUIDE TRACK IS BROKEN. REPAIRED RH HORIZONTAL STABILIZER UPPER SLIDING SEAL FWD GUIDE TRACK PER 23-153-00526.SDR SWAA2023021502628Handle · loose*C/R* R2 DOOR FWD ASSIST HANDLE LOOSE<[01] RESECURED FWD R2 DOOR ASSIST HANDLE IN REF TO B737 AMM 52-41-31-020-008.;[02] VERIFIED STEP NO 1.SDR SWAA2023021502809Light · inoperativeL/H OVERWING EMERGENCY EXIT EXTERIOR LIGHT INOP<[01] REPLAMPED OVERWING EMERGENCY EXIT LIGHT IAW AMM 33-51-04SDR SWAA2023021502860Slide · out of positionFWD FLIGHT ATTENDANT REPORTS: FWD SERVICE DOOR SLIDE; DROOPING.<[01] REPOSITIONED SLIDE ASSY IAWMM 25-66-01 REF MT 725-66-01SDR SWAA2023021503367Cover · missingFO SIDE OVERWING EMERGENCY EXIT ROW LIGHT COVER MISSING ON LOWER SIDEWALL.<[01] REF. AMM 33-51-01.<BR><BR>INSTALLED EXIT COVER SIGN.SDR SWAA2023032002663Spar · crackedCRACK INSPAR RIB 120.30 AT 18 INCHES FROM FRONT SPAR AT LT HORIZONTAL STABILIZER 2023-127441<[01] ET TOOL USED: PN: MIZ-21C ; SN: 769680; DUE DATE: 07-JUL-23;[02] TOOL USED PN:NORTEC 600D;PN:200053402;DUE DATE:13-MAY-23;[03] TOOLS USED: TEMPERATURE CONTROLLER SDR SWAA2023031602641Scuff Plate · crackedFWD CARGO COMPARTMENT SCUFF PLATE FWD CORNER HAS CRACK<[01] RECEIVED SERVICEABLE FWD CORNER SCUFF PLATE AT FWD CARGO; WELDED BY J.L. WELDING P. O. # 413896; SERVICEABL SCUFF PLATE TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00HR48J;[02] VERIFIED STEP 1.SDR SWAA2023031602642Scuff Plate · crackedFWD CARGO COMPARTMENT SCUFF PLATE AFT CORNER HAS CRACK<[01] RECEIVED SERVICEABLE AFT CORNER SCUFF PLATE AT FWD CARGO; WELDED BY J.L. WELDING P. O. # 413894; SERVICEABLE SCUFF PLATE TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00HR48J;[02] VERIFIED STEP 1.SDR SWAA2023031302588Structure · corrodedMAIN CABIN FWD. WET AREA CORROSION AT INNER CHORD LBL 55' BETWEEN STA 294.5-312 [TTG8Q00HRY1G]<[01] TASK C/WSDR SWAA2023031302758Floor Panel · delaminatedFWD CABIN FLOOR PANEL 222BF HAS A DELAMINATION ON O/B EDGE APPROXIMATELY 4' AFT OF FWD EDGE<[01] IDENTIFIED 222BF PANEL IAW SRM 53-00-50-0I-1 PARA FIGURE 2; TABLE 2.<BR><BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR><BR>WILL SDR SWAA2023031302759Floor Panel · delaminatedAFT CABIN FLOOR PANEL 242UF HAS A DELAMINATION ON THE LOWER SKIN AFT EDGE AT GIRT BAR ATTACH POINT<[01] IDENTIFIED PANEL 242UF MATERIAL IAW SRM 53-00-50-0I-1 FIG 6; TABLE 6.<BR><BR>FOUND DAMAGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F. <BRSDR SWAA2023031302656Plate · crackedCRACK REAR SPAR CORRUGATED PLATE LOCATED AT IRSS 216 AT LT WING 2023-113071<[01] REPLACED REAR SPAR CORRUGATE PLATE LOCATED AT IRSS 216 AT LT WING I.A.W. B737-700 SRM 51-10-02 AND SRM 51-40-02 AND DWG 115A2001 SHEET 30 REV.A. DUE TO NOT FOUND ALLOWABLE DAMAGE SDR SWAA2023031302332Track · crackedCRACK CARGO TRACK LOCATED BS747 RBL13 AND WL156 AT AFT CARGO COMPARTMENT 2023-113064<[01] TOOL USED DIGITAL CALIPER P/N: 500-197-30 S/N: B20189511 DUE DATE: 12-OCT-23.;[02] PERFORMED REPAIR ON CARGO TRACK LOCATED BTW BS727E MORE 7.5? TO BS747 MORE 11? RBL13 ANSDR SWAA2023031302655Angle · crackedCRACK ANGLE LOCATED BTW STA 907 TO STA 927 STS 25L TO STR 27L AFT CARGO COMPARTMENT 2023-113072<[01] REPLACED ANGLE LOCATED BTW STA 907 TO STA 927 STS 25L TO STR 27L AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02; SRM 51-20-02 ITEM 9 AND DWG 147A7221 REV. -. SDR SWAA2023031302657Support · crackedCRACK ANGLE - SUPPORT LOCATED STA 867 AT LEVEL STR 26L AFT CARGO COMPARTMENT 2023-113074<[01] REPLACED ANGLE - SUPPORT LOCATED STA 867 AT LEVEL STR 26L AFT CARGO COMPARTMENT I.A.W B737-700 SRM 51-10-02 ITEM 9 AND DWG #149A8102 REV:-;[02] REPLACED ANGLE - SUPPOSDR SWAA2023031002871Stiffener · crackedCRACK FOUND AT FASTENER HOLE LOCATION RBL 54.21 AFT STIFFENER COMMON TO RT VAPOR BARRIER LOWER WEB STA 663; CRACK APPROX DEPTH 0.020' > . CRACK FOUND AT FASTENER HOLE LOCATION RBL 54.21 AFT STIFFENER COMMON TO RT VAPOR BARRIER LOWER WEB STA 663 CRACK APPROX DESDR SWAA2023031004390Angle · crackedCRACK FOUND AT FASTENER HOLE LOCATION RBL 54.21 FORWARD ANGLE COMMON TO RT VAPOR BARRIER LOWER WEB STA 663; CRACK APPROX DEPTH 0.020'< . CRACK FOUND AT FASTENER HOLE LOCATION RBL 54.21 FORWARD ANGLE COMMON TO RT VAPOR BARRIER LOWER WEB STA 663 CRACK APPROX DEPSDR SWAA2023030902654Angle · crackedCABIN FLOOR SUPPORT INTERCOSTAL AT 380-400 2'LEFT OF CENTER LINE IS CRACKED.<[01] INSTALLED EWIS PROTECTION AT ANGLE REPLACEMENT AREA PER B737-700 AMM 20-60-07-913-801.;[02] REMOVED CRACKED ANGLE AT FLOOR STRCTURE BET. STA 380 AND STA 400 BL0 PER B737-700 SRM SDR SWAA2023021502478Cover · brokenFWD GALLEY EMER. EXIT LIGHT COVER BROKEN<[01] RESECURED LIGHT COVER PER AMM 33-14-00.SDR SWAA2023021502479Tailpipe · fireENGINE TAILPIPE FIRE @ 75KTS DURING T/O ON NO 1 ENG REJECTED T/O ; PERFORMED QRH PROCEDURES .FLAMES WERE REPORTED FROM ANOTHER A/C AND TOWER RAN BRAKE COOLING ON PWB TAXI TO GATE NORMALLY FIRE TRUCKS CLEARED US TO GATE RAN COOLING FOR APPROX 3 MINUTES PRIOR TOSDR SWAA2023032002231Support Angle · corrodedCORROSION ** AT R-1 SERVICE DOOR CUTOUT LOWER SILL INNER SCUFF PLATES SUPPORT ANGLE<[01] REMOVED SURFACE CORROSION ON R-1 LOWER MAIN SILL I/B ANGLE ON UPPER SURFACE PER B737-700 SRM 51-10-02-0G-G.;[02] VERIFIED STEP1;[03] MEASUREMENTS FOR INNER CHORD; ORIGINALSDR SWAA2023032002337Flap · debondedCUSTOMER REQUEST - DEBONDED IB MAIN FLAP WEDGE PANEL LOWER SURFACE AT RT WING 2023-127406<[01] TOOL USED CALIPER P/N 500-197-30 S/N A21147765 DUE DATE 08/NOV/23.;[02] TOOL USED BOND TESTER PN S-3 SN 064 DUE DATE 19-JUL-23;[03] TOOL USED: HOT BONDER P/N:HCS9200SDR SWAA2023031702311Cap · elongatedAFT CARGO COMPARTMENT L/H CAP STRIPS WITH HOLE ELONGATED<[01] RECEIVED NEW AFT CARGO CAP STRIPS P/NS; 453A2611-8; -10;-4;- AND -13; NEW CAP STRIPS TOB INSTALLED ON CUSTOMER BAR CODE TTG8Q00GS7H9 AND TTG8Q00GS7HB;[02] VERIFIED STEP 1SDR SWAA2023031602338Light · brokenBROKEN STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN (10 EA) 2023-127410<[01] REPLACED STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN (10 EA) I.A.W B737-700 AMM 33-51-15-400-802 AND DWG 33500007 REV .2;[02] COMPLETEDSDR SWAA2023031302378Panel · tornFWD CABIN FLOOR PANEL 222DF HAS A TORN OUT FASTENER HOLE ON THE O/B EDGE<[01] IDENTIFIED FLOOR PANEL 222DF MATERIAL IAW SRM 53-00-50-0I-1 FIG. 2 TABLE 2. DAMAGE AT DISCREPANT LOCATION EXCEEDS ALLOWABLE DAMAGE LIMITS AND REQUIRES A PERMANENT REPAIR IAW SRM 53-0SDR SWAA2023031302329Panel · delaminatedDELAMINATED ACCESS PANEL 193AR AT LOWER FUSELAGE 2023-113052<[01] TOOL USED: CALIPER PN: 500-197-30 B20189526 DUE DATE: 20/DEC/23.;[02] TOOL USED HOT BONDER P/N: HCS9200B P/N: 18165044; DUE DATE: 28-FEB-23;[03] TOOL USED: SCALE PN: SPX621; SN: 8340225441; DUE SDR SWAA2023031302382Floor Panel · brokenFWD CABIN FLOOR PANEL 221BF HAS BROKEN TANG ON AFT I/B END<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>RESDR SWAA2023031302383Panel · brokenFWD CABIN FLOOR PANEL 221GF HAS BROKEN TANG ON FWD O/B END<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>RESDR SWAA2023031302331Track · crackedCRACK CARGO TRACK LOCATED BS767 LBL17 AND WL156 AT AFT CARGO COMPARTMENT 2023-113063<[01] TOOL USED: DIGITAL CALIPER; P/N: 500-193-30; S/N:0000293; DUE DATE:12-OCT-23.;[02] PERFORMED PERMANENT REPAIR CARGO TRACK LOCATED BS747 TO BS 787 LBL17 AND WL156 AT AFT CSDR SWAA2023022202392Web · elongatedFLIGHT DECK REPAIR EA 21-153-00734 HAS 2 ELONGATED HOLES AT B/S 260 MARKED IN RED.<[01] REAMED TWO HOLES NEXT OVER-SIZE BY 1/32 INCHES IN ACCORDING EA M-21-153-00734 SWA REPAIR FLIGHT DECK FLOOR WEB DENT REPAIR AT BS 260(TTG8Q00HQESA) STEP 16; NOTE ONE.;[02] PSDR SWAA2023021502182Bolt · faultySEAT 11F IS RECLINING INTO THE EXIT ROW<[01] REMOVED AND REPLACED SEAT 11F BREAKOVER BOLT AND NUT PER CMM 25-21-42. OPS CHECK GOOD.SDR SWAA2023021502411Light · inoperativeEMERGENCY LIGHT AT MAIN CABIN SEAT ROW CBA1 IS INOP WHEN EMERGENCY LIGHTS SELECTED TO ON EMERGENCY LIGHT AT MAIN CABIN ROW CBA1 IS INOP WHEN EMERGENCY LIGHTS SELECTED TO ON<[01] REMOVED AND REPLACED AREA EMERGENCY LIGHT AT MAIN CABIN SEAT ROW CBA1 AS PER REFERSDR SWAA2023032002086Intercostal · crackedFWD CABIN FLOOR INTERCOSTAL AT 312-328 RIGHT B/L 28 IS CRACKED<[01] REMOVED INTERCOSTAL AT FWD CABIN FLOR STA 312 TO 328 RIGHT BL 28 FOR CRACKED SRM 51-40-02 -0G-0;[02] VERIFIED STEP 1AND OK TO INSTALL NEW INTERCOSTAL;[03] RECEIVED NEW PART PO#2002351) INSTALLSDR SWAA2023032001780Structure · corrodedCORROSION....R/H AFT CABIN FLOOR @ STA 947.5 - STA 992.8 + 6 RBL 57 WL 208.1 INNER CORD HAS CORROSION. (18-41)<[01] FOUND EXFOLIATE CORROSION ON R/H INNER CHORD FROM STA. 947.5 TO STA. 992.8; OUT OF LIMITS PER SRM 53-70-15-1A-1REMOVED R 2 DOOR INNER CHORD; PERSDR SWAA2023032001767Structure · corrodedCORROSION....L/H AFT CABIN FLOOR @ STA 986.5 LBL 43 WL 208.1 T - CORD FASTENER HOLE HAS CORROSION. (18-46)<OUT OF LIMITS PER REF SRM 53-70-51-1A-1 CUT OUT DAMAGE SECTION ON FLOOR BEAM STA 986.5; LBL 43' PER REF SRM 53-70-51-2R-6;[07] VERIFIED STEP 6;[08] PERFOSDR SWAA2023032002083Intercostal · corrodedCABIN FLOOR SUPPORT INTERCOSTAL BETWEEN 294.5-312 LEFT B/L 12 IS CORODED<[01] INSTALLED EWIS AND FOD PROTECTION ON AREA AS PER AMM 20-60-07-913-801.;[02] PARTIALLY REMOVED DAMAGED CABIN FLOOR SUPPORT INTERCOSTAL BETWEEN 294.5-312 LEFT B/L 12 PER REF SRM 51-40-SDR SWAA2023032002082Structure · corrodedR-! DOOR THRESHOLD INTER CORD HAS CORROSION.<[01] REMOVED SURFACE CORROSION ON INNER CHORD UPPER SURFACE AROUND FASTENER HOLES PER B737-700 SRM 51-10-02-0G-G.;[02] VERIFIED STEP1;[03] MEASUREMENTS FOR INNER CHORD; ORIGINAL MATERIAL 0.80'; MATERIAL LOSS .016' ASDR SWAA2023031601989Floor Panel · corrodedCABIN FLOOR PANEL 221BF HAS CORRODED INSERTS<[01] RECEIVED NEW PANEL P/N 141A5810-56 INSTALLATION WILL BE ACCOMPLISH ON TTG8Q00GS734;[02] RECEIVED NEW PANEL P/N 141A5810-56 INSTALLATION WILL BE ACCOMPLISH ON TTG8Q00GS734SDR SWAA2023031601762Floor Panel · peelingAFT CABIN FLOOR PANEL 241XF UPPER SURFACE PEELING.<[01] RECEIVED NEW CABIN FLOOR PANEL 241 XF; NEW FLOOR PANEL TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00GS6T5;[02] VERIFIED STEP 1 RECEIVING FLOOR PANEL 241XF AND TO BE INSTALLED ON TTG8Q00GS6T5.SDR SWAA2023031601778Floor Panel · peelingAFT CABIN FLOOR PANEL 241YF UPPER SURFACE PEELING.<[01] RECEIVED NEW CABIN FLOOR PANEL 241 YF; P/N 147A5810-77; NEW FLOOR TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00GS6UA;[02] VERIFIED STEP 1 RECEIVING FLOOR PANEL 241YF AND TO BE INSTALLED ON TTG8Q00GS6UA.
Back to Boeing 737-7H4