SDR AMTA200600079Power Supply · unserviceableRIGHT SIDE, AFT, TWO EXTERIOR EMERGENCY LIGHTS OUT. DURING T/S, FUSE BROKE OFF IN POWER SUPPLY M1695. REMOVED AND REPLACED POWER SUPPLY M1695. ALSO REPLACED BAD FUSE IN POWER SUPPLY M1691. ALSO, REPLACED BAD FUSEL IN POWER SUPPLY M1691 TO FIX INOPERATIVE LJan 25, 2006 · N304TZ · Boeing 73783N · Emergency LightingSDR AMTA200500316Overheat Sensor · malfunctionedAFTER GEAR RETRACTION, WHEEL WELL FIRE LIGHT ILLUMINATED WITH FIRE BELL. COMPLETED WHEEL WELL FIRE PROCEDURES, LIGHT WENT OUT ON SHORT FINAL, BRAKE TEMPS WERE (0) DEG AND HYD NORMAL. REMOVED AND REPLACED OVERHEAT DETECTION CONTROL UNIT IAW MM. OPS CHECK GOMar 27, 2005 · N314TZ · Boeing 73783N · Overheat DetectionSDR AMTA200500257Slide · failedWHILE COMPLYING WITH WORK CARD 382F2501 L1 SLIDE, SN NG4084, FAILED TO DEPLOY WITH EITHER NORMAL OR MANUAL DEPLOY PROCEDURES. SLIDE WAS REPLACED AND OPS CHECK NORMAL. (K)Mar 13, 2005 · N319TZ · Boeing 73783N · Escape SlideSDR 2005FA0000183Psu · contaminatedCONTAMINATION ON INSIDE OF PSU. WHILE CARRING OUT ROUTINE MAINTENANCE ON PAX PSUS, CONTAMINATION WAS FOUND AT ROWS 8,13, 18, AND 23 LT AND RT. CONTAMINATION APPEARS AS SOME FORM OF CARBON OR GRAPHITE. IT IS LOCATED DIRECTLY BELOW WHERE THE OVERHEAD BINS JOIJan 31, 2005 · N312TZ · Boeing 73783N · Crew Oxygen SystemSDR AMTA200500023B-Nut · looseENGINE NR 2 OIL QUANTITY LOW. ENGINE OIL PRESSURE FLUCTUATIONS DURING APPROACH. OIL PRESSURE REACHED RED LINE AFTER CLEARING R/W. SHUTDOWN NR 2 ENGINE DURING TAXI. FOUND LOOSE B-NUT, TIGHTENED SAME ON TRANSFER GEAR BOX VENT LINE. LEAK CHECK, OK. (K)Jan 4, 2005 · N313TZ · Boeing 73783N · Turbine Engine Oil SystemSDR AMTA200400379Floor Panel · corrodedCORROSION: AFT CARGO COMPARTMENT, FLOOR PANEL. DUE TO OLD SEALANT A ROUND CARGO TIEDOWNS WAS NOT REMOVED CAUSING BULGE IN NEW PANEL. NEW SEALANT NOT APPLIED EITHER. ALSO INCORRECT MM REF USED. INSTALLED PANEL IAW SRM. REMOVED OLD SEALANT AROUND CARGO TIEMar 31, 2004 · N308TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400361Computer · malfunctionedELEVATORY FEEL DIFFERENTIAL LIGHT ILLUMINATED. REMOVED AND REPLACED ELEVATOR FEEL COMPUTER IAW MM 27-31-37-4. COMPLIED WITH STEP 3G2 AND 3 MM 27-31-37-4 FEEL FORCE SYSTEM TEST AMM TASK 27-31-00-700-812. SYSTEM OPS CHECK GOOD. (M)Mar 28, 2004 · N318TZ · Boeing 73783N · Elevator Control SystemSDR AMTA200400377Floor Panel · corrodedCORROSION: AFT CARGO COMPARTMENT, FLOOR PANEL. FABRICATED PANEL 14 OBF IN C2 PIT IAW SRM, INSTALLED FLOORBOARD IAW AMM IN C-2 PIT.Mar 28, 2004 · N308TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400180Odor · detectedHOT PLASTIC ODOR IN AFT GALLEY AREA. ODOR SUBSIDED AND DIDN'T RETURN AFTER GALLEY POWER AND OVENS TURNED OFF, ALTHOUGH FLIGHT ATTENDANTS COULDN'T ISOLATE ODOR TO OVENS. NO SMOKE OR FIRE. OPS CHECKED AFT GALLEY OVENS COULD NOT DUPLICATE PROBLEM. NOTIFIED OPFeb 18, 2004 · N321TZ · Boeing 73783N · Air Distribution SystemSDR AMTA200400173Heater · malfunctionedRIGHT ELEVATOR PITOT HEAT LIGHT CAME ON ON RECALL BEFORE TAXI CHECK. REMOVED AND REPLACED RIGHT ELEVATOR PITOT PROBE PER MM 27-31-94-4. OPS CHECK NORMAL. (M)Feb 15, 2004 · N314TZ · Boeing 73783N · Pitot/Static Anti-Ice SystemSDR AMTA200400174Igniter · failedLEFT ENGINE FAILED TO LIGHT OFF WITH RIGHT IGNITION SELECTED. REMOVED AND REPLACED NR 1 ENGINE RIGHT IGNITOR PLUG IAW MM 74-21-02-4. OK FOR SERVICE. (M)Feb 13, 2004 · N303TZ · Boeing 73783N · Spark Plug/IgniterSDR AMTA200400161Panel · corrodedFOUND C2 CARGO PANEL CORROSION AT STATION 767 TO 727J. FOUND CORROSION OUT OF LIMITS PER SRM 53-00-53-1. FABRICATED NEW PANEL PER SRM 53-60-53-01 AND INSTALLED PANEL. (M)Feb 12, 2004 · N304TZ · Boeing 73783N · Fuselage Miscellaneous StructureSDR AMTA200400159Floor Panel · corrodedC-2 CARGO PANELS HAVE CORROSION APPROX STATION 727A TO 727E. FOUND CORROSION OUT OF LIMITS PER SRM 53-00-53-1. REMOVED FLOOR PANEL. FABRIATED AND INSTALLED NEW PANEL. (M)Feb 12, 2004 · N304TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400160Floor Panel · corrodedFOUND C-2 CARGO PIT FLOOR PANEL HAS CORROSION STATION 727E TO 727J. CORROSION OUT OF LIMITS PER SRM 53-00-53-01. REMOVED FLOOR PANEL, FABRICATED AND INSTALLED NEW PANEL IAW AMM 51-40-02-0. (M)Feb 12, 2004 · N304TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400151Window · gougedPILOTS SLIDING WINDOW HAS GOUGED FROM CONTACTING HEX BOLTS FWD EDGE OF FRAME, UPPER CORNER. REMOVED AND REPLACED ELFT NR 2 SLIDING WINDOW IAW M/M56-12-11-4. (M)Feb 11, 2004 · N303TZ · Boeing 73783N · Flight Compartment WindowsSDR AMTA200400122Panel · corrodedFOUND C2 CARGO PANEL NR 1 HAS CORROSION. CORROSION BEYOND LIMITS PER SRM. FABRICATED NEW PANEL AND INSTALLED PANEL.Feb 5, 2004 · N323TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400119Power Supply · inoperativeFOUND LEFT AFT O/W EXIT EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK CHARGER PER MM 33-51-06, OPS GOOD. (M)Feb 5, 2004 · N332TZ · Boeing 73783N · Emergency LightingSDR AMTA200400127Floor Panel · corrodedFOUND C2 CARGO PIT, AREA UNDER CARGO LOADING SYSTEM, PARTICALLY BY DOOR HAS CORROSION ON FLOOR STATION 727J TO 787. REMOVED AND REPLCED C-2 PIT FLOOR PANEL REF 737 AMM 25-51-1 0-4. (M)Feb 4, 2004 · N303TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400126Floorboard · corrodedFOUND FLOORBOARD INBOARD OF C2 DOOR HAS CORROSION AT FORWARD END, STATION 887 TO 740 LBL 20 TO RBL 20. REMOVED AND REPLACED C-2 PIT FLOOR PANEL REF 737 AMM 25-52-10-4. (M)Feb 4, 2004 · N303TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400078Megaphone · inoperativeFOUND AFT CABIN MEGAPHONE INOPERATIVE. REMOVED AND REPLACED AFT CABIN MEGAPHONE. (M)Jan 25, 2004 · N306TZ · Boeing 73783N · Emergency EquipmentSDR AMTA200400089Floor Panel · corrodedFOUND C2 CARGO FLOOR PANEL UNDER LOADING SYSTEM CORRODED FROM DOOR FORWARD. REMOVED AND REPLACED CARGO FLOOR PANEL. REINSTALLED ON A/C IAW 737 AMM 25-52-10-4. SEALED FITTINGS IAW 737 AMM 20-30-1 1-2. COATED PANEL WITH ABRASION PROTECTIVE COATING. (M)Jan 23, 2004 · N304TZ · Boeing 73783N · Fuselage Floor PanelSDR AMTA200400048Skin · gougedFOUND TWO GOUGES ON THE C1 CARGO DOOR, BOTH VERTICALLY 7 INCHES AND 4.1, 8 LONG IN ADJACENT BAYS. COMPLY WITH ERA 737-52R-5423 FOR REPAIR. COMPLIED WITH ERA 737-52R-5423. GOUGES CUT OUT AND DOUBLER INSTALLED IAW ERA. (M)Jan 19, 2004 · N302TZ · Boeing 73783N · Cargo/Baggage DoorsSDR AMTA200400047Panel · corrodedFOUND C-2 CARGO PANELS HAVE SURFACE CORROSION STATION 792 TO FORWARD BULKHEAD. CORROSION OUT OF LIMITS ON PANEL FROM STATION 767 TO 887. FABRICATED NEW PANEL, COATED AND INSTALLED NEW CARGO FLOOR PANEL IAW 727 SRM 51-40-02-0 AND AMM 25-52-10-400-801. (M)Jan 19, 2004 · N302TZ · Boeing 73783N · Fuselage Main, Plate/SkinSDR AMTA200400046Skin · corrodedFOUND C-2 PIT JUST FORWARD OF DOOR CUT OUT STATION 792-760 FLOOR PANEL HAS CORROSION. CORROSON OUT OF LIMITS PER SRM. REMOVED FLOORPANEL AND FABRICATED NEW PANEL. INSTALLED NEW PANEL PER SRM 51-40-02-0. TOP COATED PANEL WITH BMS 10-86 TY1 FOR PROTECTION. Jan 15, 2004 · N301TZ · Boeing 73783N · Fuselage Main, Plate/SkinSDR AMTA200400029Track · missingFOUND SECTION OF PHOTOLUMINESCENT EGRESS TRACK MISSING IN FARTHEST AFT CABIN ON LEFT. REPLACED SECTION OF PHOTOLUMNINESCENT TRACK LIGHTING AS REQ'D. (M)Jan 10, 2004 · N305TZ · Boeing 73783N · Emergency EquipmentSDR AMTA200400030Ballast · failedFOUND LEFT AFT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BALLAST AS REQUIRED CHECKS GOOD. (M)Jan 9, 2004 · N306TZ · Boeing 73783N · Emergency LightingSDR AMTA200301197Warning Light · illuminatedLT PACK LIGHT COMES ON DURING MASTER CAUTION RECALL. PERFORMED BITE TEST ON LEFT PACK TEMP ZONE CONT. OP CHECK GOOD, AS PER FIM 21-62-00-810. (M)Sep 18, 2003 · N315TZ · Boeing 73783N · Cabin Temperature IndicatorSDR AMTA200301147Ballast · inoperativeFOUND LEFT MIDDLE FORWARD WINDOW EXIT SIGN LIGHT, ABOVE THE OVERWING EXIT IS INOPERATIVE. REMOVED AND REPLACED LEFT FORWARD OVERWING EXIT LIGHT ASSEMBLY IAW MM 33-21-00-2. OK FOR SERVICE. (M)Sep 8, 2003 · N325TZ · Boeing 73783N · Emergency LightingSDR AMTA200301085Battery · dischargedALL F/A JUMPSEAT EMERGENCY FLASHLIGHT ARE WEAK AND BATTERIES NEED REPLACED. REMOVED AND REPLACED ALL F/A JUMPSEAT EMERGENCY FLASHLIGHTS. OPS NORMAL PER M/M 25-64-00. OK FOR SERVICE. (M)Aug 23, 2003 · N304TZ · Boeing 73783N · Emergency EquipmentSDR AMTA200301084Battery · dischargedMEGAPHONE IN COMPT 704 NEEDS BATTERIES REPLACED. REMOVED AND REPLACED MEGAPHONE BATTERIES PER MM 25-34-00. OK FOR SERVICE. (M)Aug 23, 2003 · N304TZ · Boeing 73783N · Emergency EquipmentSDR AMTA200301065Brake · malfunctionedSUSPECT DRAGGING BRAKE, RETURN TO GATE. REMOVED AND REPLACED NR 3 MAIN BRAKE ASSEMBLY IAW MM 32-41-41, OPS AND LEAK CHECK NORMAL. (M)Aug 17, 2003 · N327TZ · Boeing 73783N · Landing Gear Brake SystemSDR AMTA200301055Sign · damagedEMERGENCY EXIT INDICATOR AFT OF R4 DOOR DAMAGED. REMOVED AND REPLACED EMERGENCY INDICATOR ASSEMBLY AFT OF R4 DOOR, OPS CHECK GOOD PER AMM 33-51-01. (M)Aug 14, 2003 · N316TZ · Boeing 73783N · Emergency LightingSDR AMTA200301054Lens · missingRIGHT SIDE OVERWING AFT LOWER EMERGENCY LIGHT LENSE ASSEMBLY MISSING. INSTALLED NEW LIGHT ASSEMBLY, OPS CHECK GOOD REF MM 33-51-01-2. (M)Aug 12, 2003 · N310TZ · Boeing 73783N · Emergency LightingSDR AMTA200301036Odor · detectedLIGHT ODOR OF SMOKE IN ROWS 24 PLUS 25, NO VISABLE SMOKE IN CABIN. OPERATED PACKS WITH ENGIENS PLUS APU INSPECTED OVERHEAD PANELS FOR ROWS 23 THROUGH 26, NO ODOR OF SMOKE OF EVIDENCE OF SMOKE NOTED. (M)Aug 8, 2003 · N331TZ · Boeing 73783N · Air Distribution SystemSDR AMTA200300987Power Supply · dischargedRIGHT AFT EXTERIOR OVERWING EMERGENCY LIGHT INOPERATIVE, ALSO EXTERIOR EMERGENCY LIGHT FORWARD OF LIGHT POWER SUPPLY AS PER AMM 33-51-06. (M)Aug 1, 2003 · N313TZ · Boeing 73783N · Emergency LightingSDR AMTA200300986Slide · unsecureFLT 645 - ESCAPE SLIDE PACK IS HANGING LOOSE IN DOOR. RESECURED VELCRO STRIPS TO SLIDE BACKING PAN PER M/M 25-66-01, OK FOR SERVICE. (M)Aug 1, 2003 · N307TZ · Boeing 73783N · Escape SlideSDR AMTA200300968Strip · detachedEMERGENCY FLOOR LIGHTING STRIP DETACHED FROM FLOOR BY AFT LAVATORY. REMOVED AND REPLACED AFT LEFT PHOTOLUMINESCENT STRIP PER MM 33-51-15. (M)Jul 28, 2003 · N314TZ · Boeing 73783N · Emergency EquipmentSDR AMTA200300969Warning System · malfunctionedRIGHT PACK LIGHT ILLUMINATED ALONG WITH CONT CABIN AND FORWARD CABIN LIGHTS. PERFORMED FIM 21-62-00-810-848, AND PACK/ZONE TEMP CONTROLLER BITE IAW 21-62-00-810-801. NO DEFECTS NOTED. (M)Jul 28, 2003 · N303TZ · Boeing 73783N · Cabin Cooling SystemSDR AMTA200300955Pump · inoperativeON DESCENT THE LT ENG FAIL ILLUMINATED FOLLOWED BY SOURCE OFF, LEFT ENGINE RE-LIT. MOVING THRUST LEVER TO IDLE RESULTED IN LEFT ENGINE FAIL AGAIN. MOVING THRUST LEVER FORWARD MADE ENGINE LIGHT OFF AGAIN. REMOVED AND REPLACED FUEL PUMP IAW MM. PACKAGE REMOVJul 19, 2003 · N306TZ · Boeing 73783N · Engine Fuel PumpSDR AMTA200300890Power Supply · malfunctionedALL EGRESS LIGHTS AROUND LEFT AFT SERVICE DOOR INOPERATIVE. RESET POWR SUPPLY WITH SWITCH PER 737 MM 33-51-00. LIGHTS OPS CHECKED NORMAL. (M)Jul 7, 2003 · N310TZ · Boeing 73783N · Emergency LightingSDR AMTA200300790Fuse · failedRIGHT OVERWING EXTERIOR EGRESS LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK FUSES. OPS CHECK GOOD. (M)Jun 17, 2003 · N311TZ · Boeing 73783N · Emergency LightingSDR AMTA200300773Container · looseFOUND DOOR L2 SLIDE CONTAINER LOOSE. SECURED 2L DOOR CONTAINER. OK FOR SERVICE. (M)Jun 13, 2003 · N319TZ · Boeing 73783N · Escape SlideSDR AMTA200300772Lens · crackedEMERGENCY EXIT LENS FORWARD OF R1 DOR CRACKED. REPLACED LIGHT ASSEMBLY PER AMM 33-51-01, OPS CHECK GOOD. (M)Jun 13, 2003 · N313TZ · Boeing 73783N · Emergency LightingSDR AMTA200300768Battery · dischargedEMERGENCY FLASHLIGHT AFT GALLEY INOPERATIVE. REMOVED AND REPLACED BATTERY FOR FLASHLIGHT. (M)Jun 12, 2003 · N324TZ · Boeing 73783N · Emergency EquipmentSDR AMTA200300769Cover · dislodgedFOUND R-1 DOOR SLIDE FALLING OUT OF COVER. RESTOWED SLIDE IN COVER, OK FOR FLIGHT. (M)Jun 12, 2003 · N312TZ · Boeing 73783N · Escape SlideSDR AMTA200300761Valve · malfunctionedLEFT PACK TRIP LIGHT, WOULD NOT RESET. FOUND ON RECALL. REMOVED AND REPLACED LEFT PACK TCV VALVE PER MM 21-51-10-4. OPS CHECK GOOD. LEAK CHECK GOOD. (M)Jun 10, 2003 · N304TZ · Boeing 73783N · Cabin Cooling SystemSDR AMTA200300719Actuator · malfunctionedAFTER TAKEOFF, UPON GEAR RETRACTION RED NOSE GEAR AND GREEN NOSE GEAR LIGHTS REMAINED ILLUMINATED. LOUD AIR NOISE HEARD AND RETURNED TO PHL. REMOVED AND REPLACED NOSE GEAR LOCK ACTUATOR IAW AMM 32-33-21-4. CYCLED GEAR 5 TIMES. LEAK AND OPS CHECK GOOD. NO May 28, 2003 · N301TZ · Boeing 73783N · Landing Gear ActuatorSDR AMTA200300716Light · inoperativePROX LIGHT FORWARD ENTRANCE FOR EMERGENCY EGRESS LIGHTS INOPERATIVE AND BROKEN IN PIECES. REMOVED AND REPLACED PROX LIGHT ASSEMBLY FOR EGRESS LIGHTING AT FORWARD ENTRANCE OPS CHECKS NORMAL. (M)May 27, 2003 · N302TZ · Boeing 73783N · Emergency LightingSDR AMTA200300733Oven · malfunctionedOVEN GLIDES IN FORWARD AND AFT GALLEY CREATE BILLOWING CLOUDS OF SOOT AND BLACK SMOKE WHEN COOKING ENTREE'S, AS REPORTED BY SR F/A. CATERING REMOVED AND REPLACED INSERTS AND GUIDES. OVENS IN FORWARD AND AFT GALLEY, OP CHECKED GOOD AMM 25-00-00. (M)May 18, 2003 · N302TZ · Boeing 73783N · Buffet/GalleysSDR AMTA200300751Skin · dentedFOUND LEFT WING INBOARD TRAILING EDGE AFT FLAP LOWER SKIN DENTED. REPAIRED SKIN IAW SRM 51-70-10-2. (M)May 16, 2003 · N317TZ · Boeing 73783N · Trailing Edge Flaps
Back to Boeing 737-83N