Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2019021528175Wire Harness · failedFOLLOW UP TO HISTORY OF #2 ENGINE FIRELOOP B FAULTS. GROUNDED - YES. REMOVED AND REPLACED #2 ENGINE UPPER DETECTOR ASSEMBLY. REVERSED ALTERNATE DEACTIVATION PROCEDURES. ETOPS GROUND VERIFICATION NOW OPS NORMAL REF B737-800 AMM TASK 26-11-00-710-801. CLOSED TSRSDR ASAA2019021428493Shield · corrodedAFT PIT RT SHIELD IS CORRODED BETWEEN BS767 - BS787+6. GROUNDED - YES. REMOVED CORROSION ON SHIELD AT AFT PIT RT STA. 767-787+6 IAW SRM 53-60-15 FIG.103 DETAIL D. ORIGINAL MAT .050, MATERIAL LOSS .008, REMAINING MAT. .042 AND IS OUT OF LIMITS IAW SRM 53-60-15.SDR ASAA2019021428451Channel · corrodedAFT PIT LT ZEE CHANNEL IS CORRODED BETWEEN BS727J - 747. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS, ORIG THICKNESS .040 MATERIAL REMOVED .006 REMAINING THICKNESS .034 PER DWG BAC 1496-377 AND SRM 53-00-53-2R-5 TOOL# 8225R. REMOVED DAMAGE, MATSDR ASAA2019021428446Floorbeam · corrodedMAIN CABIN AFT WET AREA FLOORBEAM UPPER SURFACE AT STA 986.5 RBL 28 HAS CORROSION. GROUNDED - YES. REMOVED CORROSION ON THE UPPER SURFACE OF THE FLOORBEAM AT STA 986.5, RBL 28, ORIGIAL THICKNESS 0.150, REMAINING THICKNESS 0.130, REMOVED 0.020 FOUND TO BE OUT OSDR ASAA2019021428408Bulkhead · crackedACCESS AND OVER SIZE BS 540 BULKHEAD LOWER CHORD FASTENER HOLE LT SIDE SHOWING CRACK INDICATION. GROUNDED - YES. REPAIRED BS540 LT LOWER CHORD IAW EA 800-53EA-21262.SDR ASAA2019021428214Engine · making metalWHILE ACCOMPLISHING T/C 78472040 FOUND MAGNETIC PARTICLES IN AGB/TGB SCAVENGE MCD ON NR 1 ENGINE. GROUNDED - YES. INSPECTED STARTER MAGNETIC PLUG ON NR 1 ENG FOUND NO MATERIAL ON MAGNETIC PLUG REF AMM 79-00-00-240-001-F00. REMOVED AND REPLACED NR 1 ENGINE REF SDR ASAA2019021428201Hf Comm · malfunctionedAIRBORNE, BOTH HF NR 1 AND HF NR 2 NEITHER RADIO WOULD TUNE, NO TUNING SIDETONE FOR EITHER RADIO. WE COULD HEAR CONVERSATION ON BOTH HF RADIOS. NEITHER L OR R WOULD TUNE OR TALK ON EITHER RADIO. GROUNDED - YES. PERFORMED HF BIT CHECK ON HF NR 1 AND HF NR 2 REFSDR ASAA2019021428199Autothrottle Sys · malfunctionedAUTOTHROTTLE TRIPPED OFF TWICE DURING DESCENT. GROUNDED - YES. ACCOMPLISHED AUTOTHROTTLE SYSTEM- OPERATIONAL TEST REF AMM 22-31-00-710-801. ALL TESTS PASSED. ACCOMPLISHED AUTOTHROTTLE SYSTEM- SYSTEM TEST REF AMM 22-31-00-710-802. ALL TESTS PASSED. GROUND VERIFSDR ASAA2019021428194Warning System · false activationCONTROL ZONE TEMP OFF LIGHT ON. GOES OUT WITH MASTER CAUTION RESET. GROUNDED - YES. PERFORMED A/C TEMP CONTROLLER BITE CHECK PER CONTROLLER PLACARD, ONE FAULT, NR 2 TEMP CONTROLLER FLT DECK TRIM VLV. RAN CONTROLLER BITE & RESET, NO FAULTS NOTED. RAN NR 2 CONTRSDR ASAA2019021428192Warning System · false activationRIGHT HAND PACK LIGHT ILLUMINATES ON RE-CALL AND EXTINGUISHES WHEN MASTER CAUTION "PUSH TO RESET" IS PUSHED. GROUNDED - YES. RELEASED PER MEL 21-32B. RIGHT HAND PACK PRIMARY TEMP CONTROL INOP. NR 2 PACK/ZONE TEMP CTRLR SHOWS "TCV THIS PACK" FAULT ON PREV FLT &SDR ASAA2019021428191Warning System · false activationRIGHT PACK LIGHT ILLUMINATED DURING RECALL. EXTINGUISHED AFTER RESET. GROUNDED - YES. PERFORMED RIGHT PZTC BITE & FAULT REVIEW REF AMM 21-51-00. FOUND 1 HIT FOR RIGHT RAM AIR ACT IN PREV FLT. NO FAULTS IN BIT OR VERIFY. RESET FAULTS. VERIFIED PROPER RT RAM AIRSDR ASAA2019021428177Battery Pack · dischargedEMERGENCY LIGHTS INOP AT R/H SEAT ROWS 3-12, RT 27-29, AND ALL EMERGENCY LIGHTS AROUND R2 DOOR. GROUNDED - YES. REMOVED AND REPLACED BATTERY PACK AT STATIONS 500C+7 WL 213 RBL 67 (M1676) AND STATION 952 WL 291 RBL 14 (M1672) IAW AMM 33-51-06. SYSTEM CHECKS GOOSDR ASAA2019022738366Floorbeam · wornMAIN CABIN FLOOR STRUCTURE, STA 520 FLOORBEAM UPPER T-CAP HAS DEEP WEAR MARK APPROX. RBL 10. GROUNDED - YES. REMOVED DAMAGE TO UPPER T CAP REF: B737-800 SRM 53-00-51-2R-1. ORIGINAL MATERIAL .125 MATERIAL REMOVED 100%, LOCATED AND DRILLED REPAIR ANGLES #1 AND #SDR ASAA2019021328168Warning System · false activationLEFT PACK LIGHT ILLUMINATES ON RECALL. GROUNDED - YES. ACCOMPLISHED PACK/ ZONE TEMPERATURE CONTROLLER BITE TEST, OPS NML REF AMM 21-61-00-700-806-002.SDR ASAA2019021228169Warning System · false activationAFTER START ON RECALL "FLT CONT" LIGHT "ON" AND "MACH TRIM" AND AUTO SLAT" FAIL LIGHT "ON" ON OVERHEAD. ALL LIGHTS RESET WITH MASTER CAUTION RESET BUTTON. GROUNDED - YES. RESET SYSTEM AND RE-RAN SPEED TRIM TEST, OPS CHECK GOOD. RAN BITE LIBRARY TESTS IAW AMM 2SDR ASAA2019021228157Warning System · false activationAFTER PUSH BACK "ELEC" ILLUMINATED. GROUNDED - YES. C/W FIM 24-31 TASK 825 FOUND AUX BAT CHGR FAULT TO BE INTERMITTENT, VERIFIED BOTH BATTERY CHARGERS GREEN LIGHTS ON, PERFORMED STANDBY POWER SYSTEM OPS CK REF AMM 24-34-00-710-802 FOR ETOPS GROUND VERIFICATIONSDR ASAA2019021128533Mechanism · brokenLEFT ELEVATOR MECHANISM HAS 2 EACH SPRING BROKEN; REQUIRES AN ODR. REF: CARD G1127029 FOR INBOUND ELEVATOR FAILED POWER OFF 18 TURNS NOSE DOWN. GROUNDED - YES. REMOVED AND REPLACED L/H ELEVATOR TAB CONTROL MECHANISM IAW AMM 27-31-34. OPS CHECKS GOOD.SDR ASAA2019021128252Floorbeam · corrodedAFT WET AREA STA 947.5 HAS AREA OF CORR AT LBL 53. GROUNDED - YES. REPAIRED FLOORBEAM UPPER FLANGE IAW SRM 53 70 51 2R 5 W 1" O .180 R .138 L 1" D .042".SDR ASAA2019021128159Starter · failedUPON ENGINE START NR 2 ENGINE NO ROTATION WITH GOOD DUCT PRESSURE, NR 1 ENGINE START NORMAL. GROUNDED - YES. REMOVED AND REPLACED NR 2 ENGINE STARTER AND START VALVE REF AMM 80-11-01 AND 80-11-03, LEAK AND OPS CHECK GOOD.SDR ASAA201902128151Lubrication Unit · stuckFWD SUMP SEALING SPOOL ON LUBE UNIT STUCK OPEN AND SEALS ARE CUT, #1 ENGINE. GROUNDED - YES. REPLACED #1 ENGINE LUBE UNIT PER B737-800 AMM 79-21-01. LK CK GOOD.SDR ASAA201902128147Display · malfunctionedPRIOR TO PUSH BACK F/O'S NAV DISPLAY MAP LIGHT ILLUMINATED F/O LOST ROUTE, CAPTAIN'S OK. GROUNDED - YES. ACCOMPLISHED RESET OF FMC SYS. NO FAULTS EVIDENT. REF B737-800 FIM TASK 34-61.SDR ASAA201902128145Fire Loop · faultedNR 2 ENGINE B LOOP INDICATES A FAULT DURING ENGINE FIRE TEST. GROUNDED - YES. FOUND #2 ENGINE UPPER FAN B LOOP FAULT. POWERED DOWN SYSTEM REF B737-800 AMM 20-60-99. ACCOMPLISHED OPS CHECK OF FIRE DETECTION SYSTEM IAW AMM 26-11-00. NO HISTORY LAST 10 DAYS. GROUSDR ASAA2019021028135Charger · failedAFTER ENGINE START, ELEC. LIGHT ON OVH PANEL ILLUMINATED. GROUNDED - YES. AUX BATTERY CHARGER POPS BREAKER, REMOVED AND REPLACED AUX BATTERY CHARGER IAW 24-31-31-401, OPS CHECK GOOD IAW AMM 24-31-31-501. BATTERIES, MAIN AND AUX WERE DISCONNECTED FOR MAINTENANCSDR ASAA2019020928605Transition Panel · corrodedFWD. CARGO COMPARTMENT RT TRANSITION PANEL HAS CORROSION STA.500F TO STA.500G LBL.24. MARKED IN RED. GROUNDED - YES. REMOVED CORROSION ON RT TRANSITION PNL ORG MAT .040 REMOVED .007 REMAINING .033 AND FOUND TO BE OUT OF LIMITS IAW DWG #BAC1496-444 AND SRM 51-1SDR ASAA2019020928532Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1671 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED M1671 BATTERY PACK. OPS CHECK GOOD. AMM 33-51-06 & 33-51-00.SDR ASAA2019020928531Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1673 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED M1673 BATTERY PACK. OPS CHECK GOOD. AMM 33-51-06 & 33-51-00.SDR ASAA2019020928530Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1672 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED M1672 BATTERY PACK. OPS CHECK GOOD. AMM 33-51-06 & 33-51-00.SDR ASAA2019020928529Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1670 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED M1670 BATTERY PACK. OPS CHECK GOOD. REFERENCE: AMM 33-51-06 & 33-51-00.SDR ASAA2019020928528Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1694 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED B1634 BATTERY PACK. OPS CHECK GOOD. REFERENCE: AMM 33-51-06 & 33-51-00.SDR ASAA2019020928527Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1695 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED M1695 BATTERY PACK. OPS CHECK GOOD. REFERENCE: AMM 33-51-06 & 33-51-00.SDR ASAA2019020928526Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1676 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED M1676 BATTERY PACK. OPS CHECK GOOD IAW AMM 33-51-06 & 33-51-00.SDR ASAA2019020928525Battery Pack · defectiveEMERGENCY LIGHT BATTERY PACK M1675 FAILED DISCHARGE CHECK. GROUNDED - YES. REMOVED AND REPLACED M1675 BATTERY PACK. OPS CHECK GOOD. REFERENCE: AMM 33-51-06 & 33-51-00.SDR ASAA2019020928141Eec · failedNR 1 ENGINE HAS FAULT CODE 73-10771, PS3 SIGNAL IS OUT OF RANGE (LONG TIME). GROUNDED - YES. REMOVED AND REPLACED NR 1 ENG EEC. REF AMM 73-21-60-401 PERFORMED EEC TEST, EEC DISCREET TEST, IDENT CONFIG. NO DEFECTS NOTED. REF AMM 73-21-00-700-802-F00 TEST 12 ACTSDR ASAA2019020928133Warning System · false activationON RECALL "CONT CAB" ZONE TEMP LIGHT REMAINED ILLUMINATED WITH AIR COND LIGHT. LIGHT EXTINGUISH WITH MASTER CAUTION RESET. GROUNDED - YES. UNABLE TO DUPLICATE DEFECT - MASTER CAUTION RECALL SHOWED NO ZONE TEMP LIGHTS, BITE OF BOTH PACK/ZONE TEMP CONTROLLERS PESDR ASAA2019020828580Transition Panel · corrodedAFT PIT, LT TRANSITION PANEL HAS CORROSION 4 PLACES BETWEEN STA 727I AND 727J. GROUNDED - YES. REMOVED CORROSION ORG THICKNESS .040 REMOVED .007 REMAINING .033 FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 AND DWG BAC1496-444 TOOL# T8225P. REMOVED TRANSITION PNL SSDR ASAA2019020828388Intercostal · corrodedFWD WET AREA BS270 HAS AREAS OF CORROSION LBL 12 TO RBL 12. GROUNDED - YES. REMOVED CORR FROM FWD WET AREA BS 270 BETWEEN LBL 12 AND RBL 12, FOUND TO BE OUT OF LIMITS IAW SRM 53 10 51 1A 1 REPAIRED BS 270 BETWEEN LBL 12 AND RBL 12 IAW EA 800 53EA 21263 W 1 O .SDR ASAA2019020828273Floorbeam · corrodedAFT WET AREA CORR ON STA 986 FLOORBEAM UPPER FLANGE LBL 21 TO RBL 43. GROUNDED - YES. REPAIRED 986 FLOORBEAM IAW SRM 53 70 51 2R 6 W 1" O .150" R .122' L 4" D .028".SDR ASAA2019020828272Floorbeam · corrodedAFT WET AREA STA 947.5 FLOORBEAM UPPER FLANGE HAS AREAS OF CORR AT APPROX LBL5. GROUNDED - YES. REPAIRED FLOORBEAM AND INSTALLED ALL REPAIR PARTS ON UPPER FLANGE IAW SRM 53 70 51 2R 6 W 2" O .180" R .154" L 1" D .026".SDR ASAA2019020828271Pressure Panel · crackedUPON NDT INSPECTION FOUND CRACK IN O/B BAY OF LT PRESSURE WEB. GROUNDED - YES. REPAIRED LT PRESSURE WEB IAW SRM 51 10 10 2R 3 REPAIR 3 ALTERNATIVE 2.SDR ASAA2019020828144Computer · failedAUTOTHROTTLES DISENGAGED TWICE DURING DESCENT WHILE THRUST LEVERS WERE AT IDLE. GROUNDED - YES. PERFORMED REVIEW OF A/T INFLIGHT FAULTS. AGAIN "ASM- 1 MOTOR PWR FAILED". MSG 22-31518. REF PREVIOUS HISTORY ASM-1 ALREADY CHANGED. T/S PER FIM 22-31 TASK 805. PERFSDR ASAA2019020828182Intercostal · crackedFWD WET AREA FORMED INTERCOSTAL STA 312 TO 328 LBL 45.5 IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED DAMAGED INTERCOSTAL AT FWD WET AREA STA 312 TO 328 LBL 45.5 IAW SRM 51 40 02 0G 0.SDR ASAA2019020828180Pressure Panel · crackedUPON NDT INSPECTION FOUND CRACK IN O/B BAY OF RT PRESSURE WEB. GROUNDED - YES. REPAIRED RT PRESSURE WEB IAW SRM 57 10 10 2R 3 REPAIR 3 ALTERNATIVE 2.SDR ASAA2019020828137Compensator · failedTECH SERVICES REQUEST, DUE TO RECENT FUEL IMBALANCE ISSUE, CHECK NR 1 (LEFT) FUEL TANK UNIT VALUES. GROUNDED - YES. PERFORMED CAPACITANCE CHECK IAW AMM 28-41-21-710-801. ALL CHECKS GOOD. WILL REQUIRE FQIS BITE AFTER LEAK CHECK. REPLACED COMP PROBE AND TANK UNISDR ASAA2019020828134Hf Comm · malfunctionedHF NR 1 WILL NOT TRANSMIT. GROUNDED - YES. GROUND VERIFICATION SUCCESSFUL AMM 23-11-00.SDR ASAA2019020828131Actuator · failedLEFT PACK LIGHT ILLUMINATED ON RECALL DURING DESCENT. LIGHT OUT WITH "MASTER CAUTION" RESET. GROUNDED - YES. LEFT ZONE TEMP CONT LOGGED RAM AIR ACT FAULT, ACTUATOR R&R PER AMM 21-51-21, C/B'S PULLED/TAGGED & UNTAGGED/RESET (3). SYS OPS CKS NML PER SAME.SDR ASAA2019021278149Actuator · leakingLEFT VSV OF L/H ENG-VSV IS LEAKING 20 DROPS PER MINUTE STAGANT FROM DRAIN TUBE. GROUNDED - YES. REMOVED AND REPLACED LEFT VSV ACTUATOR IAW B737-800 AMM 75-31-01. LEAK AND OPS CHECKED GOOD.SDR ASAA2019021278136Control Valve · failedRIGHT HAND PACK LIGHT COMES ON WITH MASTER RECALL AND DOES RESET WITH MASTER CAUTION PUSH TO RESET. GROUNDED - YES. REMOVED & REPLACED RH PACK TCV REF B737-800 AMM 21-51-10 PERFORMED OPERATIONAL / FUNCTIONAL CHECK OPS CKS NORMAL. BITE CK. ACCOMPLISHED REF AMM SDR ASAA2019020728115Blade · wornWHILE ACCOMPLISHING TASK CARD, S/N 894424 FOUND MISSING AND CHIPPED CU-NI-IN COATING BEYOND LIMITS OF AREA X. BLADES NR 1 DD459254-L NR 6 S/N DD458565-G NR 11 S/N DD458388-Y NR 21 S/N DD456868-U. GROUNDED - YES. REPLACED NR 1 ENGINE FAN BLADES NR 1, 6, 11 & 21SDR ASAA2019020728110Circuit Breaker · trippedPRIOR TO DESCENT LEFT SIDE WINDOW OVERHEAT LIGHT ILLUMINATED AND REMAINED ILLUMINATED AFTER RESET PER QRH. GROUNDED - YES. FOUND "WINDOW HEAT POWER" CB OPEN AT P6-12 B-9 RESET CB PER 20-60-01 AND BITE CHECK OF WHCU OK PER AMM 30-41 TASK 801. WINDOW HEAT OPERATSDR ASAA2019020628270Door Sill · corrodedFWD CARGO DOORWAY LOWER SILL WEB IS CORRODED. GROUNDED - YES. REMOVED CORR ON FWD CARGO DOORWAY LOWER SILL WEB FOUND TO BE OUT OF LIMITS REMOVED AND REPLACED SILL WEB IAW SRM 53 30 15 1A 1 FIG 103, 51 40 02 0G 0 W 2 O .080 R 63 L 4 D .017.
Back to Boeing 737-890