SDR ASAA2018102426591Control Panel · defectiveWX RADAR CONTROL PANEL AUTO/MAN PUSH-PUSH SWITCH WILL NOT HOLD SELECTED TO AUTO. (THE SWITCH "HOLDS" IN AUTO BUT THE RADAR STAYS IN MANUAL). GROUNDED - YES. REMOVED AND REPLACED WEATHER RADAR CONTROL PANEL PER AMM REF 34-43-91-000-801/34-43-91-400-801. OP'S CKSDR ASAA2018102326687Transition Panel · corrodedAFT PIT LT TRANSITION PANEL IS CORRODED AND HAVE MISSING NUTPLATES FROM STA 727H+10 TO STA 787.10. GROUNDED - YES. REMOVED AND REPLACED DAMAGED SECTION OF TRANSITION PANEL AND NUTPLATES IAW SRM 51 40 02 0G 0 W 1 O .040 R .020 L 2 D .020".SDR ASAA2018102326686Intercostal · corrodedAFT WET AREA DRAIN FLOOR SUPPORT LBL46 HAS CORR. GROUNDED - YES. REMOVED AND REPLACED AFT WET AREA DRAIN FLOOR SUPPORT AT LBL NG, IAW SRM 51 40 02 0G 0 W 4" O .090 R 0 L 18.5" D .090.SDR ASAA2018102326596Fcu · faultyDURING INFLIGHT START FOR CSS WE RECEIVED A FAULT LIGHT AND THE APU SHUT DOWN TWICE AT FL380, APU STARTED SUCCESSFULLY AT FL350. GROUNDED - YES. ACCOMPLISHED BITE OF APU FOUND FAULTS IN FAULT HISTORY NO ACCELERATION SHUTDOWN MESSAGE 49-41010. OVERTEMP SHUTDOWNSDR ASAA2018102626603Unknown · malfunctionedREF LOG 11903751, EGT CONNECTOR CLEANING WAS ACCOMPLISHED PER FIM TASK 77-21-00-839-007. POST CLEANING RECHECK PER T/C 78273000, FOUND FAULT 77-20861 ON LEGS 1, 2, AND 3 (ENGINE 1). GROUNDED - YES. PERFORMED EGT SYSTEM RESISTANCE CHECK (ENG NR 1) REF AMM 77-21SDR ASAA2018102326595Filter · contaminatedWHILE PERFORMING TASK CARD, FOUND METALLIC MAGNETIC CHIPS ON AGB/TGB CHIP DETECTOR. GROUNDED - YES. PERFORMED TASK AMM 79-00-00-200-804-F00 STEP 7H(7)(B)1) FOUND CONTAMINATION ON STARTER MAGNETIC PLUG. REMOVED DEBRIS FROM MAGNETIC PLUG. REPLACED SCAVENGE OIL FSDR ASAA2018102326582Filter Element · cloggedFOUND OIL FILTER INDICATOR HAS EXTENDED. GROUNDED - YES. SERVICED APU OIL FILTER INDICATOR REF AMM 49-91-13.SDR ASAA2018102426578Warning System · false activationON RECALL CONT CABIN ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. CABIN TEMP CONTROL SYSTEM INOP. NR 2 PACK/ZONE TEMP CONTROLLER FAULTED FLT DECK TRIM VALVE. FAULT VERIFIED AND RESET; ALL PASS "GO" ON BOTH ZONE TEMP CONTROSDR ASAA2018102926608Angle · crackedCABIN FLOOR INTERCOSTAL UPPER ANGLE CRACKED BETWEEN STA 380 AND 400 LBL 20. GROUNDED - YES. REMOVED CRACKED CABIN FLOOR INTERCOSTAL UPPER ANGLE BETWEEN 380 AND 400 LBL 20 IAW SRM 51 40 02 0G 0 FIG 8, LOCATED AND SRILLED NEW ANGLE IAW SRM 51 40 05 0G 0 FIG 2, ISDR ASAA2018102226588Idg · leakingFOUND NR 1 ENG LEAKING OIL AFTER SHUTDOWN AT GATE. GROUNDED - YES. REMOVED AND REPLACED NR 1 IDG IAW AMM 24-11-11-000/400-801.SDR ASAA2018102226583Bolt · wornNR 2 ENGINE FAN FRAME OUTBOARD STRUT COVER HAS A FASTENER HEAD WORN BOTTOM SIDE. GROUNDED - YES. REPLACED DAMAGE FASTENER SEE MIG 2C 40-0026341 FOR DETAILS.SDR ASAA2018102326569Warning System · false activationDUAL VTK AND FMC FAILURE ON LANDING. GROUNDED - YES. BOTH FMC'S LOGGED "GENERAL DATA SYNC ERR" AND "L/R PGM FAULT" LAST FLIGHT. PERFORMED FIM 34-61 TASK 807, OPS NML PER SAME. NO HISTORY LAST 30 DAYS. GRD VERIFICATION NML.SDR ASAA2018110826748Floorbeam · corrodedPAX CABIN, AFT WET AREA FS 947 TOP SURFACE OF FLOOR BEAM HAS CORR @ LBL4 @ FLOOR BOARD HOLE. GROUNDED - YES. REPAIRED FS 947 FROM RBL8 TO LBL8 IAW 737 800 SRM 53 70 51 24 R REPAIR 5 W 2.5" O .0180 R .117 L 16.5" D .063.SDR ASAA2018102126734Floorbeam · corrodedPAX CABIN AFT WET AREA AT FS 986.5 FLOORBEAM TOP SURFACE HAS CORR AT LBL16. GROUNDED - YES. REPAIRED FLOORBEAM STA 986.5 UPPER CAP FRM LBL8 TO LBL64 IAW SRM 53 70 51 2R 4 W 2" O .150 R .076 L 44" D .074.SDR ASAA2018102126685Door Sill · corrodedPAX CABIN FWD WET AREA R1 DOOR MOPSILL AT FS 328 AND RBL 55 HAS AREA OF CORR. GROUNDED - YES. REMOVED AND REPLACED DAMAGED MOPSILL AT R1 DOOR IAW SRM 51 40 02 0G 0 W 2 O 080 R 039 L 6 D 041.SDR ASAA2018102426579Switch · defectiveNR 1 COWL ANTI ICE LIGHT ILLUMINATED ON POWER UP TO TAXI FOR DEPARTURE. GROUNDED - YES. R & R ENG COWL TAI VALVE PER AMM 30-21-11. VALVE OPS CK NORMAL. BUT AMBER LIGHT NOW ILLUMINATES DIMLY ALL THE TIME. PERFORMED FIM 30-21 TASK 801. FOUND CONTINUITY BETWEEN PSDR ASAA2018102326572Shroud · wornNR 1 ENG ABRADABLE SHROUD HAS GROOVES COMPLETELY AROUND THE SHROUD. MAX WIDTH WAS 2.9 IN. OUT OF LIMITS PER AMM 72-24-02 F.(1)(E). GROUNDED - YES. INSTALLED NEW COMPOUND TO THE ABRADABLE SHROUD IAW AMM 72-24-02-200-802. 2.A.-F.(1)-(10). COMPLETED NR 1 ENG ABRASDR ASAA2018102326567Unknown · malfunctionedCAPTAINS LEFT SIDE WINDOW OVERHEAT GROUNDED - YES. QRH CHECKLIST COMPLETED, NORMAL OPS.SDR ASAA2018102126559Power Supply · inoperativeR1 DOOR INTERIOR AND EXTERIOR EMERGENCY LIGHTS INOP. GROUNDED - YES. REMOVED AND REPLACED FWD RIGHT EMERGENCY POWER SUPPLY REF AMM 33-51-06 OP CK GOOD.SDR ASAA2018102126557Start Valve · stuckON ENGINE NR 2 START. START VALVE OPEN LIGHT DOES NOT ILLUMINATE. GROUNDED - YES. MANUALLY OPENED START VALVE, ENGINE NR 2 STARTED NR 2. REMOVED & REPLACED NR 2 ENG START VALVE ASSY REF AMM 80-11-03. OPS CK NR 2 ENG REF AMM 71-00-00. OPS CK'S NORMAL. SUCCESSFUSDR ASAA2018102426547Actuator · stuckRIGHT PACK OFF LIGHT IN FLIGHT. RESET MC AND LIGHT WENT OUT. PACK LIGHT COMES BACK ON WITH MC RECALL THEN RESETS OUT. GROUNDED - YES. FOUND RIGHT RAM AIR DOOR INLET ACTUATOR STUCK IN FULL EXTEND POSITION AND CONTINUALLY RUNNING. ACFT RELEASED PER MEL 21-5C. RESDR ASAA2018102026584Connector · dirtyNR 1 ENGINE FMC/CDU SHOWS FAULT 75-10831, T3 SIGNAL IS OUT OF RANGE-LONG TIME FAULT. GROUNDED - YES. PER B737-800 FIM 75-33 TASK 802 INITIAL EVALUATION SHOWS FAULT 75-10831 T3 SIGNAL IS OUT OF RANGE. LONG TIME FAULT PRE CLEANING READINGS, T3 CH B: 109.62. T3 SDR ASAA2018101926558Starter · inoperativeNO N1 OR N2 WITH START SWITCH IN GROUND. START VALVE OPEN LIGHT ILLUMINATED. DUCT PRESSURE WITHIN LIMITS. GROUNDED - YES. REMOVED & REPLACED NR 1 ENG STARTER PER AMM 80-11-01 OPS & LEAK CK GOOD.SDR ASAA2018101926548Control Valve · failedZONE TEMP LIGHT ILLUMINATED. GROUNDED - YES. CONFIRMED FAULT NR 2 PACK ZONE TEMP CONTROLLER SHOWS HARD FAIL FLIGHT DECK TCV (V143). REMOVED & REPLACED FLIGHT DECK TCV REF AMM 21-61-21, LK CK & OPS CK NML REF AMM 21-61-00-700-806-002.SDR ASAA2018101826546Warning System · false activationZONE TEMP CONTROL CAB ILLUMINATED. QRH PROCEDURE COMPLETED LIGHT EXTINGUISHED. GROUNDED - YES. PERFORMED AMM TASK 21-61-00-700-808-001. BITE TEST. CHECKED GOOD. NO FAULT NOTED. ALSO RESET BOX. OPS NORMAL.SDR ASAA2018101826545Warning System · false activationRIGHT PACK TRIP, CHECKLIST COMPLETE PACK LIGHT ILLUMINATED UPON RECALL. GROUNDED - YES. T/S IAW FIM 21-62 TASK 848. DURING BITE CHECK FOUND RIGHT RAM AIR "ACT" ILLUMINATED. ACCOMPLISHED FIM 21-62 TASK 836. WAS ABLE TO RESET "ACT " FAULT LIGHT. RIGHT PACK OPS CSDR ASAA2018101926525Unknown · odorFLIGHT ATTENDANTS REPORT BURNING RUBBER SMELL DURING TAKEOFF AND CLIMB IN ROW 26. THE SMELL DISSIPATED IN CRUISE. GROUNDED - YES. ACCOMPLISHED CABIN ODOR TROUBLESHOOTING REF FIM TASK 05-51 TASK 814 RAN APU BOTH ENGS AND PACKS NO DISCREPANCIES NOTED. NO HISTORYSDR ASAA2018101726727Starter Gen · failedAPU TREND DATA SHOWS CT5ATP TEMP IS AT OR ABOVE THE THRESHOLD 605 DEGREES. GROUNDED - YES. REPLACED APU STARTER-GENERATOR DUE TO FAILURE OF FIM 24-21 TASK 814 STEP F(2)(E) AND (F). REMOVED/REPLACED SGU REF AMM 49-41-21. ACCOMPLISHED FIM 49-40 TASK 825 STEP D(9SDR ASAA2018101726560Not Reported · faultedWHILE ACCOMPLISHING T/C 78073000 FOUND ENG 2 LONG TIME FAULT MSG 75-20832 THE T3 SIGNAL IS OUT OF RANGE. GROUNDED - YES. ON DEFERRAL.SDR ASAA2018101726543Outflow Valve · failedDURING CLIMB AUTO FAIL AND ALTN LIGHT ILLUMINATED. COMPLIED WITH QRH. NORMAL OPS. GROUNDED - YES. PER FIM TASK 21-31-802 REMOVED AND REPLACED OUTFLOW VALVE REF AMM 21-31-03-000-801. OPS TESTS GOOD.SDR ASAA2018101726532Sensor · intermittentAT THE GATE WITH APU POWERING BUSES, THE APU ELECTRICAL DISCONNECTED FROM BOTH BUSES. AFTER 10 SECONDS THE APU BLUE LIGHT CAME BACK ON AND WE POWERED BOTH BUSES WITH THE APU. GROUNDED - YES. REMOVED & REPLACED APU INLET PRESSURE SENSOR REF AMM 49-52-31, REPLACSDR ASAA2018101726506Actuator · intermittentLEFT PACK LIGHT ILLUMINATED. EXTINGUISHES AFTER MASTER CAUTION RESET. GROUNDED - YES. PERFORMED PZTC BITE FOUND FAULT RAM AIR ACT NR 1 PACK. REF FIM 21-62 TASK 837 FAULT CLEARED ON VERIFY RAM AIR ACTUATOR TEST PASSES REF AMM 21-51-21-740-001.SDR ASAA2018101926531Valve · defectiveINFO ONLY: RIGHT BLEED TRIPPED OFF AT FL 380, FOLLOWED QRH BLEED REST, NO FURTHER PROBLEMS. GROUNDED - YES. NR 2 ENG FOUND VALVE GAP EXCESSIVE. VALVE REMOVAL PER AMM 36-11-06-000-801. INSTALLED SERVICEABLE HIGH STAGE VALVE, REVERSED ALT DEACTIVATION PROCEDURE SDR ASAA2018101926528Plenum · delaminatedLT AFT HEAT EXCHANGER ACCESS PANEL DOOR OPENING DELAMINATED BEYOND LIMITS. COMMON TO THE PLENUM. GROUNDED - YES. MIG-2C 40-0009860 INIT. REPLACED LT AFT HEAT EXCHANGER PLENUM REF MM 21-51-03-400-804-002, MIG 2C 40-0009860 COMPLETED.SDR ASAA2018101926527Plenum · damagedFURTHER DAMAGE NOTED ON RT AFT PRIMARY HEAT EXCHANGER PLENUM. GROUNDED - YES. REPLACED RT PRIMARY HEAT EXCHANGER PLENUM REF AMM 21-51-03-400-804-002. OPS, LEAK CK NORMAL.SDR ASAA2018101726516Battery · lowAFT RIGHT EMERGENCY LIGHTS DO NOT REMAIN ON FOR 15 MINS. GROUNDED - YES. REMOVED AND REPLACED AFT RIGHT EMGR LIGHT BATT PACK OPS NML REQ ENDURANCE TEST. AFT RIGHT EMERGENCY LIGHTS OPS CHECK GOOD IAW AMM 33-51-06.SDR ASAA2018101726514Filter Element · leakingON WALK AROUND FOUND OIL DRIPPING FROM APU DRAIN TUBE. GROUNDED - YES. CLEANED OIL FROM APU AND RAN, FOUND OIL LEAKING FROM LUBE FILTER ELEMENT BOWL. REMOVED BOWL AND FOUND BOWL O-RING BAD. INSTALLED NEW OIL FILTER AND PACKING. RAN APU FOR 30 MINUTES NO DEFECTSDR ASAA2018101726512Indication Sys · faultyFAIL INDICATORS ON HF1 RADIO. GROUNDED - YES. PERFORMED HF 1 AND 2 BITE PER FIM 23-11 TASK 801. OPS CK GOOD. NO FAULTS NOTED. NO FAIL MSG ON COMM WINDOW.SDR ASAA2018101726508Warning System · false activationAT CRUISE THE AUTO FAIL AND ALTN LIGHTS ILLUMINATED COMPLIED WITH QRH. NORMAL OPS. GROUNDED - YES. FAULT HISTORY SHOWS OFV LRU FAIL ON NR 2 CONTROLLER. PERFORMED SYSTEM TESTS ON BOTH CONTROLLERS- SYS TESTS OKAY REF FIM 21-31-TASK 801.SDR ASAA2018101626797Skin · crackedLT HORIZ LOWER SKIN HAS A CRACK AT APPROX STAB STA 134.00. GROUNDED - YES. REPAIRED SKIN IAW SRM 55 10 01 2R 11 THIS IS A CAT B REPAIR.SDR ASAA2018101626796Skin · crackedRT HORIZ LOWER SKIN HAS A CRACK AT APPROX STAB STA 100.00. GROUNDED - YES. REPAIRED SKIN IAW SRM 55 10 01 2R 11 THIS IS A CAT B REPAIR.SDR ASAA2018101626513Warning System · false activationLEFT SIDE WINDOW OVERHEAT LIGHT ILLUMINATED DURING FLIGHT. GROUNDED - YES. FOLLOWED QRH PROCEDURE. LIGHT REMAINED EXTINGUISHED AFTER 4 MINUTE COOL DOWN. INFO NOTED BY MX. NO HISTORY WITHIN THE PAST 30 DAYS. A/C OK FOR SERVICE.SDR ASAA2018101626509Control Module · failedPRESSURIZATION MODE CONTROL LAND ALT DIGITS FAILING. GROUNDED - YES. REMOVED AND REPLACED CABIN PRESSURE CONTROL MODULE, CABIN PRESSURE CONTROL SYSTEM OPS CK GOOD REF AMM TASK 21-31-00.SDR ASAA2018101626494Not Reported · meltedNR 1 ENGINE WAS OBSERVED TO HAVE MELTED MATERIAL ON THE FRONT COMPRESSOR CASE BETWEEN THE 2ND AND 3RD STAGE VSV ACTUATION RINGS FROM APPROX THE 4 O’CLOCK TO 2 O’CLOCK POSITION. GROUNDED - YES. REMOVED AND REPLACED NR 1 ENGINE.SDR ASAA2018101626492Bonding Wire · frayedNR 1 ENGINE COWL THERMAL ANTI-ICE VALVE BONDING WIRE IS FRAYED. GROUNDED - YES. REPLACED NR 1 ENG COWL THERMAL ANTI-ICE VALVE BONDING WIRE PER CFM56-7 POWER PLANT BUILDUP MANUAL 71-00-02 FIG 27-1 PGS 2 & 3. AND ALSO AMM 30-21-11.SDR ASAA2018101626491Fire Loop · out of limitsDURING NR 1 ENG FIRE TEST E&E BOX DISPLAYS NR 1 ENGINE B LOOP LEFT CORE. GROUNDED - YES. NR 1 ENG B LOOP LEFT CORE ELEMENT RESISTANCE VALUE OUT OF LIMITS REF FIM 26-10/805. REPLACED NR 1 ENGINE LEFT CORE FIRE DETECTOR ASSEMBLY. INSTALLATION TEST PASSES REF AMMSDR ASAA2018102926619Pressure Panel · crackedDURING NDT INSPECTION CRACK FOUND ON RT SIDE VERTICAL PRESSURE WEB MACHINED POCKET. GROUNDED - YES. REPAIRED RT SIDE VERTICAL PRESSURE WEB MACHINED POCKET IAW SRM 57 10 10 2R 5 REPAIR 3 ALTERNATIVE 1. THIS IS A CAT. B REPAIR, INSPECTION THRESHOLD IA 56,000 FLTSDR ASAA2018102326565Support · crackedRT WING TRAILING EDGE LOWER SURFACE PANEL 661AB SUPPORT CRACKED. GROUNDED - YES. REMOVED AND REPLACED RT WING T/E LWR SURFACE PNL SUPPORT IAW SRM 51 40 02 0G 0 STEP 4B STEP 1-6, 4C STEP 1-3 AND STEP 7A 1-6.SDR ASAA2018101526498Start Valve · failedRIGHT ENGINE START SWITCH FAILED TO ENGAGE THE START MODE IN MEX. AFTER MULTIPLE ATTEMPTS START MODE WAS SUCCESSFUL ONLY AFTER HOLDING THE START SWITCH HARD OVER AND HOLDING IN THERE. GROUNDED - YES. REMOVED AND REPLACED RIGHT ENGINE START SWITCH REFERENCE AMMSDR ASAA2018101526496Nut Plate · corrodedWHILE ACCOMPLISHING T/C 78472000 NR 1 ENGINE FOUND 3 NUTPLATE CORRODED BEHIND OIL TANK. GROUNDED - YES. REMOVED AND REPLACED ENGINE NR 1 REF W/O 428952.
Back to Boeing 737-890