SDR ASAA2018080625667Apu · damagedCHECKED APU FOR OIL CONSUMPTION. ACFT GROUNDED. ACCOMPLISHED A BOROSCOPE INSPECTION OF INNER SURFACE OF APU TURBO EXHAUST DUCT. FOUND BURN OIL EVIDENCE IAW FIM 49-95, TASK 801-STEP A-D (1) (A). REPLACED THE APU IAW AMM 49-11-00.SDR ASAA2018080125610Data Unit · failedREPORTS OF MX BLUE LIGHT ON WITH OIL LEVEL FOUND FULL AND FAULT CODE 49-72104 FOUND. GROUNDED - YES. REMOVED AND REPLACED DATA MEMORY MODULE REF AMM 49-72-11. OPS NORMAL.SDR ASAA201808065651Web · corrodedON REMOVAL OF THE AFT CARGO LOWER CENTER BULL NOSE SCUFF PLATE. FOUND THE CARGO DOOR CUTOUT LOWER SILL WEB HAD CORROSION. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-60-15-1A-1. REMOVED AND REPLACED THE SILL WEB IAW SRM 5SDR ASAA2018080225627Start Valve · faultyDURING ENGINE START OF NR 2 ENGINE THE START VALVE OPEN LIGHT WOULD NOT ILLUMINATE. GROUNDED - YES. REMOVED AND REPLACED NR 2 ENG START VLV. LK & OPS NORMAL REF AMM 80-11-03. START VLV OPEN INDICATION OPS NORMAL.SDR ASAA2018080025625Fault Message · false indicationAFTER LANDING CAPTAIN'S INBOARD DU WAS GETTING INTERMITTEN VTK FLAG. GROUNDED - YES. PERFORMED FIM 34-61 TASK 801. NO FAULTS NOTED FIM TASK 34-61 TASK 836 LIST VTK FLAG AS NUISANCE FAULT AND A/C REBOOTED AND CLEARED W/ NO FAULTS NOTED.SDR ASAA2018080225623Unknown · malfunctionedNR 1 ENGINE SPAR VALVE CLOSED ANNUNCIATOR STAYS BRIGHT. GROUNDED - YES. RECYCLED ENG NR 1 FUEL SPAR VALVE CB, OPS CHECK NORMAL NO HISTORY 30 DAYS.SDR ASAA2018080125614Guide Arm · out of adjustRAMP REPORTS R1 DOOR DIFFICULT TO CLOSE. GROUNDED - YES. C/W GALLEY SERVICE DOOR ADJUSTMENT PER AMM 52-41-00, ADJUSTED GUIDE ARM AND PINS. OPS CHECKED GOOD.SDR ASAA2018080225622Pump · failedNR 2 FWD LOW PRESSURE LIGHTS ILLUMINATED WITH PUMP SWITCH ON (FUEL). GROUNDED - YES. REMOVED AND REPLACED THE NR 2 FUEL TANK FWD BOOST PUMP MOTOR IMPELLER ASSY REF AMM 28-22-41-000-801 AND 28-22-41-400-801, NR 2 FWD BOOST PUMP OPERATIONAL TEST PASS REF AMM 28-SDR ASAA2018080125609Control Valve · failed"PACK" LT ILLUM ON RECALL, RESET W/ MC RESET. GROUNDED - YES. REMOVED & REPLACED LT PACK TCV AMM 21-61-21 OPS CHECK NORMAL.SDR ASAA2018080125608Warning System · false activationPRESSURIZATION CONTROL PANEL "AUTO FAIL" LIGHT ILLUMINATED ON SHORT FINAL APPROACH. GROUNDED - YES. VERIFIED DISCREPANCY. FOUND NR 1 CONTROLLER FAULTING LRU CODE 57. PERFORMED FIM 21-31 TASK 801 (DCPC) BITE PROCEDURE. NO ACTIVE FAULTS FOUND. SYS RESET. FAULT CSDR ASAA2018073125590Warning System · false activationAMBER FD FLAG IN CAPTAINS PFD. GROUNDED - YES. PERFORMED LAND VERIFY TEST REF AMM 22-11-00 BITE GROUP 49. NO FAULTS.SDR ASAA2018073125589Warning System · false activationFLT CONTROL CAUTION LIGHT, SPEED TRIM FAIL ON RECALL. EXTINGUISHES ON RESET. GROUNDED - YES. FLT FAULT REVIEW LOGGED FAULTS 22-11182 AND 22-11208 STAB TRIM CUTOUT FAULT. PERFORMED FIM 22-13 TASKS 813 AND 818 NO FAULTS. PERFORMED LAND VERIFY TEST REF AMM 22-11-SDR ASAA2018073125588Circuit Breaker · trippedAUTOTHROTTLE WILL NOT STAY ENGAGED. GROUNDED - YES. RESET FCC A C/B. ACCOMPLISHED AUTOTHROTTLE OPS CK REF AMM 22-31-00-710-801, GOOD.SDR ASAA2018073125587Circuit Breaker · trippedON MASTER CAUTION RECALL GOT MACH TRIM FAIL LT. GROUNDED - YES. RESET FCC A C/B. ACCOMPLISHED MACH TRIM ACT TEST REF AMM 22-11-24-740/801, PASSED.SDR ASAA2018073125585Warning System · false activationAUTO FAIL LIGHT ILLUMINATED ON PRESSURIZATION CONTROL PANEL. ALTN GREEN LIGHT ILLUMINATED. GROUNDED - YES. RECYCLED SWITCH TO MANUAL AND BACK TO AUTO. GOOD FOR SERVICE.SDR ASAA2018080225628Sensor · dirtyFOUND NR 2 ENGINE ECONOMIC FAULT 77-20862 "THE BOTTOM LEFT EGT SIGNAL IS OUT OF RANGE". GROUNDED - YES. ACCOMPLISHED EGT CLEANING PROCEDURES, BEFORE CLEAN TEMP READS: S1- 126.50, S2- 70.25, S3, S4- 123.12. AFTER CLEAN, TEMPERATURES READS: S1- 65.37, S2- 35.00,SDR ASAA2018080125573Unknown · malfunctionedAUTOLAND UNSATISFACTORY. AT APPROX 70 FEET AGL, AUTOPILOT COMMENCED A LEFT BANK, FOLLOWED QUICKLY BY AN APPCH WARNING. GROUNDED - YES. ACCOMPLISHED LLM MAINTENANCE PRACTICES FOR LLM SPECIAL CONDITION. INBOUND CONDITION RELATED TO AUTOLAND PER AMM 22-00-01-730-SDR ASAA2018073025567Start Valve · failedNR 1 START VALVE WOULD NOT OPEN FOR START. GROUNDED - YES. C/W FIM TASK 80-07 TASK 804. CONFIRMED 28V AT CONNECTOR DP1202 ON NR 1 ENGINE. REMOVED AND REPLACED NR 1 START VALVE PER AMM 80-11-03. OPS AND LEAK CHECKS GOOD.SDR ASAA2018073025561Blade · damagedWHILE ACCOMPLISHING T/C 78472002 ENG NR 2 S/N 894523 FOUND NR 4 FAN BLADE C/C SIDE CU-NI-IN COATING CHIPPED & MISSING MEASURED AT 1.2. FOUND PLATFORM ELASTOMER SEALS TORN & UNBONDED TOTALING 45 INCHES. FOUND 10 SPACERS WITH DISBONDED ELASTOMER STRIPS. GROUNDEDSDR ASAA2018072825615Fault Message · false indicationFOUND NR 1 ENG LOGGED LONG TIME FAULT MSG NR: 75-10831 - THE T3 SIGNAL IS OUT OF RANGE. GROUNDED - YES. ON NR 1 ENGINE PERFORMED EEC BITE TEST RECENT FAULTS PER AMM 73-21-00-740-803. NO FAULTS FOUND. PERFORMED EEC BITE TEST FAULT HISTORY PER AMM 73-21-00-740-8SDR ASAA2018081525777Bulkhead Web · crackedPRESSURE BULKHEAD WEB WAS CRACKED BS 663, LBL 25-45. ACFT GROUNDED. REPAIRED THE PRESSURE BULKHEAD WEB IAW SRM 57-10-10-2R.SDR ASAA2018081525773Floor Support · corrodedFLOOR SUPPORT BS 950, LBL 24 WAS CORRODED AT MULTIPLE AREAS. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02.SDR ASAA2018081525769Bulkhead Web · crackedRIGHT AFT PRESSURE BULKHEAD WEB AT BS 663 WAS CRACKED ON THE OTBD SIDE. ACFT GROUNDED. THE PRESSURE WEB WAS REPAIRED IAW SRM 57 10 10 2R 3.SDR ASAA2018080125551Unknown · malfunctionedA/T WILL NOT STAY ENGAGED. GROUNDED - YES. PERFORMED OPS TEST & SYS TEST REF AMM TASK 22-31-00 710-801 & TASK 22-31-00-710-802, RESPECTIVELY. CHECKED GOOD. NO FAULTS.SDR ASAA2018073125552Window · faultyON FINAL APPROACH, DESCENDING OUT OF 1000 MSL THE RIGHT FORWARD WINDOW OVERHEAT LIGHT ILLUMINATED. PERFORMED WINDOW OVERHEAT QRH ON TAXI IN AND THE OVERHEAT LIGHT ILLUMINATED AGAIN. GROUNDED - YES. ACCOMPLISHED WINDOW HEAT BITE TEST. WINDOW IS FAULTING SENSOR.SDR ASAA2018073025575Satcom · lockedSATCOM LOCKUP GROUNDED - YES. PERFORMED SATCOM LOCKUP QRH. SATCOM RETURNED TO MENU SATISFACTORY.SDR ASAA2018073025560Warning System · false activationAPU OVERSPEED LIGHT ILLUMINATED, APU RUNNING FOR AT LEAST 4 MINUTES. GROUNDED - YES. PERFORMED APU BITE CHECK REF FIM TASK 49-60-00-810-801 FOUND OVERSPEED FAULT TO BE AN INTERMITTENT FAULT. APU GROUND VERIFICATION CHECKS NORMAL.SDR ASAA2018073025557Software · faultedVTK DISPLAYED ON BOTH NAVIGATION DISPLAYS AFTER LANDING DURING TAXI - IN TO OAK. GROUNDED - YES. PERFORMED FIM 34-61 TASK 801, SYSTEM CHECKS GOOD. INFLIGHT FAULTS HAD ONE GROUND FAULT FOR RT FMC, CODE 3DD REVEALED IT WAS A PROGRAM FAULT, A SOFTWARE INSTRUCTIONSDR ASAA2018073025554Warning System · false activationINTERMITTENT DISPLAY OF VTK ON BOTH CAPTAINS AND FIRST OFFICERS MAPS FMC ALERT LIGHT ILLUMINATED. GROUNDED - YES. LEFT AND RIGHT FMC'S OPS CHECKS GOOD REF FIM 34-61 TASK 801.SDR ASAA2018073125591Eec · faultyWHILE ACCOMPLISHING T/C 78273000 FOUND MAINT MESSAGE 75-20832. T3 SIGNAL OUT OF RANGE. LONG TIME FAULT. DEFERRED PER T/C 78273000. GROUNDED - YES. PERFORMED FIM 75-33 TASK 802 AND FOUND EEC REQUIRES REPLACEMENT. REMOVED AND REPLACED NR 2 ENGINE EEC REF AMM 73-SDR ASAA2018080375632Bracket · brokenLOWER FUSELAGE KEEL BEAM PANEL SUPPORT BRACKET BROKEN AT BS 551. ACFT GROUNDED. REMOVED AND REPLACED THE SUPPORT BRACKET IAW SRM 51-40-02, AND 51-40-05.SDR ASAA2018073125586Sensor · out of adjustSTAB TRIM MOTOR FAILED TEST PER AMM 22-11-81-710-801, AMM 27-41-00-700-801, ACCOMPLISHED STAB ELEC TRIM SYSTEM TEST REF AMM 27-41-00-700-803, TEST NORMAL, COULD NOT DUPLICATE FAILED TEST. UNABLE TO PERFORM LAND VERIFY DUE TO FCC-A FAILURE. SUSPECT STAB POS SENSDR ASAA2018073125568Control Valve · failedAFTER START RIGHT PACK LIGHT CAME ON. GROUNDED - YES. REPLACED RIGHT PACK TCV (V141) PER AMM 21-61-21/401. OPS GOOD.SDR ASAA2018073025571Unknown · malfunctionedCONT CAB TEMP STILL SWINGS EXCESSIVELY WHEN CONT CAB KNOB ADJUSTED. GROUNDED - YES. UNABLE TO DUPLICATE FAILURE. GVI OF STANDBY TCV & TEST PER AMM 21-51-11-400-801 STEPS G1 THROUGH G15. NO FAILURES NOTED.SDR ASAA2018073025553Sensor · failedOVERHEAT LIGHT ON LEFT FORWARD WINDSHIELD. GROUNDED - YES. BITE CHECKED LT FWD WHCU REF FIM 30-41 TASK 801. FAULTS SENSOR. SWAPPED TO SPARE SENSOR USING S1078, STILL FAILS WINDOW SENSOR REF WDM 30-41-11. REMOVED L1 WINDOW REF AMM 56-11-11-000-801. PERFORMED LESDR ASAA2018073025548Control Valve · failedUNABLE TO CONTROL CONT CAB TEMP SWINGS UP TO 20 DEGREES. GROUNDED - YES. REMOVED & REPLACED LT PACK TEMP CONTROL VALVE PER AMM 21-51-10-400-801. LEAK CK GOOD. CLEANED TEMP CONTROL CABIN TEMP SENSOR REF AMM 21-61-10. TESTS NORMAL.SDR ASAA2018073025546Warning System · false activationLEFT PACK LIGHT ILLUMINATED ON SYSTEM RECALL AND RESET WITH PRESSING MASTER CAUTION LIGHT. GROUNDED - YES. LEFT PACK FAULT CLEARED DURING THE PACK/ZONE TEMP CONTROLLER BITE TEST REF AMM 21-51-00-700-803 AND IS CONSIDERED AN INTERMITTENT FAULT.SDR ASAA2018082165867Floorbeam · corrodedFWD WET AREA BS 312 FLOORBEAM LBL 10 TO 20 HAD CORROSION ON THE UPPER HORIZONTAL FLANGE. ACFT GROUNDED. REPAIRED THE FLOORBEAM IAW EA 800-53EA-20655, AND SRM 53-10-51-2R-12, REPAIR 12.SDR ASAA2018082044444Floor Support · corrodedFWD WET AREA FLOOR SUPPORT AT LBL 10, BETWEEN BS 294 - 312 HAD AREAS OF CORROSION. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02-0G.SDR ASAA2018082065827Floorbeam · corrodedFWD WET AREA BS 294, FLOORBEAM, LBL 12 HAS AREA OF CORR ON UPPER FLANGE. ACFT GROUNDED. THE FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1. REPAIRED THE FLOORBEAM IAW EA 800 53EA 20611.SDR ASAA2018082065794Angle · corrodedL2 INNER ANGLE UPPER SURFACE HAD AN AREA OF CORROSION. ACFT GROUNDED. REMOVED AND REPLACED THE ANGLE IAW SRM 51-40-02-0G-0, PG 2, STEP B AND E. FOUND TO BE OUT OF LIMITS IAW SRM 53-70-15-1A-1.SDR ASAA2018082065775Floor Support · corrodedFWD WET AREA FLOOR SUPPORT, LBL 12, BETWEEN BS 312 TO 328 WAS CORRODED ON THE UPPER FLANGE. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02-0G.SDR ASAA2018081625793Support Angle · corrodedLT SHEAR WEB SUPPORT ANGLE AT AFT END LBL 32 HAS AREA OF CORROSION. ACFT GROUNDED. REMOVED AND REPLACED THE SHEAR WEB SUPPORT ANGLE IAW SRM 51-40-02-0G-0.SDR ASAA201801525776Floor Support · corrodedFLOOR SUPPORT AT LBL12 BETWEEN BS 312 - 328, WAS CORRODED. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02.SDR ASAA2018081525774Floorbeam · corrodedBS 986 FLOORBEAM HAD AREAS OF CORROSION ON THE UPPER FLANGE. ACFT GROUNDED. THE FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED THE FLOORBEAM IAW SRM 53-70-51.SDR ASAA201808155772Floorbeam · corrodedAFT WET AREA, BS 947 FLOORBEAM UPPER FLANGE, LBL 47-50 HAD AREAS OF CORROSION. ACFT GROUNDED. REPAIRED AND REPLACED THE FLOORBEAM TEE IAW SRM 53-70-51-2R-5.SDR ASAA20180815771Floorbeam · corrodedAFT WET AREA FLOORBEAM, BS 952, LBL 16 TO LBL 24, HAD AN AREA OF CORROSION. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1, FIG 104, DETAIL C. REMOVED THE FLOORBEAM IAW SRM 51-40-02-0G-0, PARA 7D.6, FABRICATSDR ASAA2018073025572Computer · failedAUTOPILOT DISCONNECTED WOULD NOT RECONNECT. GROUNDED - YES. REPLACED FCC-A PER AMM 22-11-33/401. LRU TEST GOOD PER SUBTASK 22-11-33-74-001. NO FAULTS NOTED. LAND VERIFY TESTS ALL PASS PER AMM 22-11-00/20. CHECKED SPOILER POS SENSORS PER AMM 22-11-27/401. ALL WSDR ASAA2018073025550Computer · failedAUTO THROTTLE DISENGAGED AND WOULD NOT RENGAGE ON T/O. GROUNDED - YES. A/P DISCONNECT, THE FCC-A WAS REPLACED. ACCOMPLISHED A/T SYS TEST PER AMM TASK 22-31-00-710-802. NO FAULTS NOTED.SDR ASAA2018073025580Pump · failedNR 2 FWD BOOST PUMP LOW PRESSURE LIGHT REMAINS ILLUMINATED WITH SWITCH ON. GROUNDED - YES. REMOVED AND REPLACED NR 2 FWD BOOST PUMP REF AMM 28-22-41. OPS TEST GOOD REF AMM 28-2241-710-801.
Back to Boeing 737-890