Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2018031924013Probe · dirtyPERFORMED TC 78273000 AND FOUND NR 2 ENG ECONOMIC MSG NR 77-20862, THE BOTTOM LEFT EGT SIGNAL (T496S3) IS OUT OF RANGE. ACFT GROUNDED. PERFORMED B737-800 FIM 77-21 TASK 803 FOUND NR 2 ENGINE S3 OUT OF LIMITS. CLEANED THE NR 2 ENGINE S3 PROBE IAW AMM 77-21-0SDR ASAA2018031923960Warning Light · false activationBOTH HF RADIOS INDICATE INOPERATIVE. ACFT GROUNDED. VERIFIED FAULT, BOTH RTPS SHOW INOPERATIVE WITH EITHER HF 1 OR 2 SELECTED. PERFORMED A RADIO TUNING PANEL INOPERATIVE DISPLAY TOGGLE IAW AMM 23-12-41-800-802. BOTH RTPS NOW SHOW SELECTED FREQUENCIES WHESDR ASAA2018031923957Control Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED WITH MASTER CAUTION. THE LIGHT EXTINGUISHED WITH RESET. ACFT GROUNDED. PERFORMED A PACK/ZONE TEMP CONTROLLER BITE IAW AMM 21-61-00-700-806-002, FOUND A FLT DECK TRIM VALVE LIGHT WITH THE NR 2 CONTROLLER. REPLACED SDR ASAA2018031823958Control Valve · faultedON MASTER CAUTION RECALL, MASTER CAUTION, AIR CONDITIONING, AND LEFT PACK LIGHTS ILLUMINATED. LEFT PACK LIGHT EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. HAS A HISTORY. NR 1 PACK, TEMP CONTROLLER SHOWS TCV FAULT. RESET FAULT. REMOVED AND REPLACED SDR ASAA2018031823926Control Valve · malfunctionedZONE TEMP LIGHT ILLUMINATED ON MASTER RECALL. ACFT GROUNDED. REPLACED FLT DECK TRIM VALVE V143 IAW AMM 21-61-21. OPERATED BOTH LEFT AND RIGHT PACKS FOR APROXIMATELY 10 MINUTES. OPS CHECKED GOOD. PERFORMED PZTC BITE ON BOTH NR 1 AND 2 CONTROLLERS IAW FIM 21SDR ASAA2018031823962Lens · detachedMID CABIN CEILING EMERGENCY EXIT SIGN LENS DETACHED. ACFT GROUNDED. SECURED THE LENS IAW AMM 33-51-01.SDR ASAA2018031823928Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL DURING DESCENT, LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. TROUBLESHOT IAW FIM 21-62 / 801 & 802. APPEARS TO HAVE BEEN AN INTERMITTENT FAULT. BITE VERIFICATION TESTED NORMAL. NO OTHER RECENT HISTORY.SDR ASAA2018031823925Warning Light · false activationAUTO FAIL AND ALT LIGHT ILLUMINATED. ACFT GROUNDED. ACCOMPLISHED FIM 21-31 / 827, AUTO FAIL LIGHT ON, CYCLED TO MANUAL THEN TO AUTO, LIGHT EXTINGUISHED, RESET FAULTS WITH NO FURTHER FAULTS LOGGED.SDR ASAA2018031724025Terminal · looseNR 1 ENGINE, LOOP B OVERHEAT, HANDLE LIGHTS DO NOT ILLUMINATE ON OVERHEAT TEST. ACFT GROUNDED. MOVED THE NR 1 ENGINE OVERHEAT DETECTOR SWITCH TO NORMAL POSITION. PERFORMED ALT DEACTIVATION PROCEDURES IAW CHAP 5, TABLE 3. TERMINATED LOOSE TERMINALS ON THSDR ASAA2018031723934Fire Detector · failedFAULT IN THE NR 1 B LOOP. ACFT GROUNDED. CONFIRMED FAULT, NR 1 ENGINE B LOOP WILL NOT TEST. ENGINE, APU FIRE & OVHT DETECTION CONTROL MODULE BITE SHOWS UPPER FAN LOOP DEFECTIVE. ACCOMPLISHED DETECTOR LOOP RESISTANCE TEST IAW AMM 26-11-00-730-801, CONFIRMESDR ASAA2018031723933Module · failedLEFT GENERATOR SOURCE OFF LIGHT ILLUMINATED DURING CLIMBOUT, ZERO VOLTS AND FREQUENCIES, ACCOMPLISHED QRH PROCEDURES, APU POWER ON LEFT BUSS. ACFT GROUNDED. PERFORMED NR 1 ENGINE RUN. INSPECTED AND FOUND THE NR 1 GEN NOT COMING ON LINE. NO VOLTS OR FREQUSDR ASAA2018031723980Egt Indication · out of toleranceDURING ACCOMPLISHMENT OF TC 78273000, THE FOLLOWING FAULT DISPLAYED FOR NR 2 ENGINE. MSG NR 77-20862. BOTTOM LEFT EGT SIGNAL IS OUT OF RANGE (T495S3). FLT LEG 1 AND 2. FAULT TIME IS ECONOMIC. ACFT GROUNDED. ENGINE SHOWS NO FAULTS OR FAULT HISTORY. BITE TEST DSDR ASAA2018031723979Egt Indication · out of toleranceFAULT CODE APPEARED ON THE NR 2 ENGINE, FAULT CODE 77-20862, BOTTOM LEFT EGT SIGNAL, T495S3 IS OUT OF RANGE. ACFT GROUNDED. T49.5 S3 PROBE CHANNEL B FAULTING AND SHOWS DASHES ON INPUT MONITORING. FAULTS SHOWN ON EVERY LEG. J10 HARNESS RANG OUT WITH NO RESULSDR ASAA2018031723932Hf Comm · unknownHF RADIO INOPERATIVE. ACFT GROUNDED. NR 2 HF GROUND VERIFICATION TESTED SUCCESSFUL IAW AMM 23-11-00-710-801.SDR ASAA2018031623982Connector · dirtyFOUND FAULTS FOR THE NR 2 ENGINE, 77-20862, BOTTOM LEFT EGT SIGNAL OUT OF RANGE. ACFT GROUNDED. TSR 701692 ACCOMPLISHED EGT INDICATION SYSTEM TROUBLESHOOTING AND CONNECTOR CLEANING IAW AMM 77-21-00-140-801. RAN ENGINE FOR 5 MINUTES. ALL READING WERE WELL SDR ASAA2018031623935Warning Light · false activationRT SIDE WINDOW HEAT, OVERHEAT LIGHT ILLUMINATED. FRM 304-040-42. ACFT GROUNDED. ACCOMPLISHED A WHCU BITE IAW FIM 30-41 / 801. PREV HISTORY SHOWED WINDOW SENSOR FAULT. NO EXISTING FAULTS. ACCOMPLISHED WHCU SYS TEST IAW AMM 30-41-11-710-801. OPS CHECKEDSDR ASAA2018031524015Floorbeam · crackedFLOOR SUPPORT FROM BL0 TO LBL24 STA 540 IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED FLOOR SUPPORT AT STA 540 BL0 TO LBL24 IAW SRM 51 40 02 0G 0.SDR ASAA2018031523937Lens · detachedFLIGHT ATTENDANT REPORTED THE AFT FACING EMERGENCY EXIT COVER HAS FALLEN OFF. ACFT GROUNDED. INSTALLED THE LIGHT COVER.SDR ASAA2018031523927Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL, RESET WHEN MASTER CAUTION PUSHED. ACFT GROUNDED. RESET SYSTEM AND RAN PACKS FOR FIVE MINUTES. TESTED SYSTEM IAW AMM 21-61-00, NO FAULTS.SDR ASAA2018031423909Control Valve · faultedLEFT PACK LIGHT ON RECALL, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED A BITE TEST IAW FIM 21-53 / 809, FOUND FAULT IN THE CABIN TEMPERATURE CONTROLLER NR 1, RED LIGHT ON TCV FOR THIS PACK STAYS ON. REMOVED & REPLACED THE LEFT PACSDR ASAA2018031423915Processor · failedLEFT FUEL QUANTITY BLANKS INTERMITTENTLY. ACFT GROUNDED. COULD NOT DUPLICATE ON GROUND. IAW FIM 28-41 TASK 801, FQIS BITE SHOWS NO CURRENT FAULTS. FLT LEGS 0-6 SHOWS MESSAGE 28-41109 PROCESSOR FAILED. REPLACED TH EFQIA PROCESSOR IAW AMM 28-41-81/401. OPS SDR ASAA2018031423914Warning Light · illuminatedCARGO FIRE PANEL, DISCHARGE LIGHT ILLUMINATED. ACFT GROUNDED. REPLACED THE NR 2 CARGO FIRE BOTTLE IAW T/C 78226001, OPS CHECKED GOOD AND DISCHARGE LIGHT NO LONGER ILLUMINATED.SDR ASAA2018031423886Fault Message · false indicationFOUND MAINTENANCE MESSAGE 73-11271, NR 1 ENGINE ALTERNATOR VOLTAGE INPUT TO THE EEC IS OUT OF RANGE, SHORT TIME FAULT. ACFT GROUNDED. PERFORMED TASK CARD 78273000. NO FAULTS FOUND AND NO MAINTENANCE HISTORY FOUND WITHIN THE PAST 30 DAYS. ACFT RELEASED.SDR ASAA2018031423882Controller · failedRIGHT PACK, ZONE TEMP CONTROLLER M1443, ZONE LIGHT DOES NOT ILLUMINATE WITH LAMP TEST PRESSED. ACFT GROUNDED. REMOVED AND REPLACED THE RIGHT PACK, ZONE TEMP CONTROLLER, INSTALLATION TEST, PASSED, IAW AMM 21-61-20.SDR ASAA2018031323860Control Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. FOLLOWED QRH, LIGHT STAYED ILLUMINATED. ACFT GROUNDED. PERFORMED A PACK ZONE TEMP CONTROL BITE ON BOTH THE NR 1 AND 2 IAW FIM 21-62 TASK 801. FOUND FLIGHT DECK TRIM VALVE FAULT ON BITE, HISTORY, AND VERIFY ON TSDR ASAA2018031323881Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ON TAXI OUT. LIGHT EXTINGUISHED WITH RESET. ACFT GROUNDED. ACCOMPLISHED THE LT AND RT PZTC BITE WITH NO FAULTS NOTED IAW AMM 21-61-00. ACCOMPLISHED AN EVALUATION IAW FIM 21-62 / 842, CONTROL CABIN ZONE TEMP LIGHT REMAINS EXTISDR ASAA2018031323880Warning Light · false activationLEFT PACK LIGHT ILLUMINATED. EXTINGUISHED WITH A MASTER CAUTION RESET. ACFT GROUNDED. IAW FIM 21-53 TASK 807, 1 & 2 PZTC BITE TESTED GOOD. NO PREVIOUS FLT FAULTS LOGGED. VERIFIED LEFT PACK OPS CHECKED NORMAL ON GROUND WITHOUT FAULTS.SDR ASAA2018031323865Warning System · false activationAFTER PUSH IN, L SIDE WINDOW OVERHEAT ILLUMINATED. GROUNDED - YES. RAN QRH CHECKLIST, LIGHT EXTINGUISHED.SDR ASAA2018031223879Wire · shortedNR 1 FUEL TANK AFT PUMP LOW PRESSURE LIGHT ILLUMINATED WITH 5900 LBS INDICATED. ACFT GROUNDED. R18 GFI RELAY TRIPPED. ACCOMPLISHED FIM 28-22 / 803. FOUND WIRE W1136-3601B-16 SHORTED AT CONNECTOR D70 BACKSHELL. REMOVED THE DAMAGE, PINNED WIRING AND REPLACESDR ASAA2018031223835Fault Message · false activationFOUND A NR 2 ENGINE LONG TIME FAULT MESSAGE 73-20172, INTERNAL EEC FAULT. ACFT GROUNDED. PERFORMED T/C 78273000, NO FAULTS FOUND, ALSO NO FAULTS IN HISTORY.SDR ASAA2018031223861Controller · inoperativeFLT DECK HEAT CONTROL CABIN INOPERATIVE, RESET MASTER CAUTION, AND OPS CHECKED OK. ACFT GROUNDED. BITE CHECKED THE CONTROLLER, NO FAULTS FOUND.SDR ASAA2018031223836Eec · failedP6-2 PANEL NR 2 ENGINE EEC ALTN POWER CIRCUIT BREAKER OPEN. GROUNDED - YES. NR 2 ENGINE EEC BITE SHOWED FAULT 73-11282 "EEC CHANNEL IS NOT ENERGIZED WITH THE ALTERNATOR VOLTAGE" LOGGED FOR LEGS 0 AND 1. ATTEMPTED C/B RESET PER MM 20-60-01-810-801, WOULD NOT RESDR ASAA2018031223829Warning System · false activationCONT CAB ZONE TEMP LIGHT ON CLIMB AND RE-ILLUMINATED ON RECALL. GROUNDED - YES. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE REF AMM 21-61-00 OPS CHECK NORMAL NO FAULTS FOUND. NO HISTORY 30 DAYS.SDR ASAA2018031123833Ecu · faultedCREW ATTEMPTED APU START - FAULT LIGHT ILLUMINATED. INTERROGATED CDU FOUND FAULT CODE 49-41011 <NO FLAME SHUT DOWN>. GROUNDED - YES. ACCOMPLISHED APU BITE PER FIM 49-60 TASK 801. CURRENT STATUS SHOWS FAULT 49-94304 OIL LEVEL SENSOR FAULTY. ALSO FOUND FAULT CODSDR ASAA2018031123831Warning System · false activationRIGHT FWD WINDOW OVERHEAT LIGHT ILLUMINATED. GROUNDED - YES. ACCOMPLISHED RESET PROCEDURE PER QRH. RESTORED NORMAL.SDR ASAA2018031123830Sensing Element · failedRIGHT FWD WINDOW OVER HEAT LIGHT ILLUMINATED, WILL NOT RESET. GROUNDED - YES. SWITCHED R1 SENSOR TO ALTERNATE IAW FIM 30-41 TASK 812. ACCOMPLISHED BITE CK OF WHCU IAW FIM 30-41 TASK 801. OPS CHECK OKAY.SDR ASAA2018031123808Overheat Loop · malfunctionedNR 1 ENGINE OVERHEATT B SIDE, HAS A FAULT ON FIRE - OVERHEATT TEST. ACFT GROUNDED. COULD NOT DUPLICATE, NO FAULTS ON FIRE CONTROL PANEL OR MODULE BITE. OPS GOOD IAW AMM 26-11-02. NO HISTORY 30 DAYS.SDR ASAA2018031023862Circuit Breaker · openFCC DC CIRCUIT BREAKER FOUND OPEN. ACFT GROUNDED. PERFORMED A CIRCUIT BREAKER RESET PROCEDURE IAW AMM 20-60-01. PERFORMED AN FCC INSTALL TEST IAW AMM 22-11-33. OPS TESTED GOOD.SDR ASAA2018031023816Unknown · malfunctionedNR 1 ENGINE LAGS BEHIND NR 2 ENGINE DURING INCREASE AND DECREASE IN POWER SETTING. WITH 10% N1 CHANGE NR 1 ENGINE WOULD TAKE 4-5 SECONDS TO REACH SAME POWER SETTING AS NR 2 N1. THIS OCCURRED DURING DESCENT FROM FL 360 INCLUDING LEVEL OFF AND CONTINUED DURING TSDR ASAA2018031023813Fastener · looseWHILE ACCOMPLISHING TC 7847200 NR 1 ENGINE FOUND LOOSE FASTENER AT FAN DUCT PANEL NR 5 WITH LPTACC SCOOP. GROUNDED - YES. TIGHTENED NR 1 ENG NR 5 PANEL FASTENER REF AMM 72-23-07.SDR ASAA2018031023807Idg · leakingNR 2 IDG FREQUENT SERVICING. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 ENGINE IDG IAW AMM 24-11-11-000-801, AND AMM 24-11-11-400-801. ACCOMPLISHED TESTS FROM POWERPLANT TEST TABLE. TEST 3A. LEAK CHECKED GOOD. INSTALLATION TEST OPS CHECKED GOOD.SDR ASAA2018031023801Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION. EXTINGUISHED ON RESET. ACFT GROUNDED. ACCOMPLISHED A BITE CHECK ON THE NR 1 & 2 TEMP CONTROLLERS. NR 2 CONTROLLER SHOWS CONTROL CABIN TRIM VALVE FAULT. RESET THE NR 2 CONTROLLER, NO FAULTS NOTED.SDR ASAA2018031023799Switch · malfunctionedAUTO FAIL CAUTION LIGHT ILLUMINATED ON PRESSURIZATION CONTROL PANEL. ACFT GROUNDED. CYCLED CABIN PRESSURE CONTROL SWITCH FROM AUTO TO MANUAL AND BACK. OPS CHECKED GOOD. LIGHT WENT OUT, GROUND VERIFICATION SUCESSFUL.SDR ASAA2018030923809Circuit Breaker · openFORWARD LEFT WINDSCREEN OVERHEAT LIGHT ILLUMINATED. ACFT GROUNDED. IAW FIM 30-41 / 801. PERFORMED A BITE CHECK OF WINDOW HEAT CONTROL SYSTEM. LOGGED BUSS POWER FAULT, FOUND THE CIRCUIT BREAKER AT P6-12 OPEN IAW AMM 20-60-01. INSPECTED THE CIRCUIT BREAKERSDR ASAA2018030923806Hf Comm · malfunctionedCAPTAIN`S AND FIRST OFFICER`S COMMUNICATION PANELS DISPLAY FAILED WHEN HF 2 IS SELECTED. ACFT GROUNDED. CYCLED THE HF 2 CIRCUIT BREAKER P6-1 D2, SYSTEM RESTORED TO NORMAL. ACCOMPLISHED HF OPS TEST IAW AMM 23-11-00-710-801. GROUND VERIFICATION TEST PASSED, NOSDR ASAA2018030923804Transceiver · intermittentFAIL DISPLAY ON BOTH ACTIVE AND STBY WINDOWS OF THE NR 1 HF. ACFT GROUNDED. DISCREPANCY WAS INTERMITTENT. NR 2 HF WAS NORMAL. REPLACED THE NR 1 HF TRANSCEIVER. OPS NORMAL IAW AMM 23-11-21.SDR ASAA2018030923800Warning Light · false activationAFTER ENGINE START CHECKLIST. ON INITIATING MASTER CAUTION RECALL, THE LT PACK LIGHT ILLUMINATED, LIGHT EXTINGUISHED WHEN MASTER CAUTION SYSTEM WAS RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-61 TASK 801. TCV FAULT CLEARED. RECALL CHECKED GOOD.SDR ASAA2018030823803Satcom · malfunctionedSATCOM RADIO ON SAT 2 OR SAT 1 NO RECEIVE AND NO SIDE TONE. STATION CALLED REPORTED RECEIVING LOUD AND CLEAR. ACFT GROUNDED. PERFORMED A SATCOM SYSTEM TEST IAW AMM 23-15-00. OPS CHECKED NORMAL.SDR ASAA2018030823810Warning System · false activationLEFT SIDE WINDOW OVERHEAT ILLUMINATED GROUNDED - YES. PERFORMED QRH PROCEDURE AND SYS RESTORED TO NORMAL.SDR ASAA2018030724077Door Frame · corrodedL1 DOOR FWD LOWER FRAME AT BS 303 HAS CORROSION AT FLOOR LEVEL. ACFT GROUNDED. REPAIRED THE DOOR FRAME IAW EA 53EA 20029.
Back to Boeing 737-890