Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2015060912043Warning Message · false activationFMC DISAGREE AFTER ENGINE START. ACFT GROUNDED. CHECKLIST COMPLETED. OPS NORMAL.SDR ASAA2015060912042Sensor · failedRIGHT ALPHA VANE LIGHT ILLUMINATED MOMENTARILY. ACFT GROUNDED. R & R NR 2 AOA SENSOR IAW AMM 34-21-05. OPS CHECKED NORMAL.SDR ASAA2015060912041Warning Light · false activationRT ALPHA VANE LIGHT ILLUMINATED MOMENTARILY ON ENGINE START. ACFT GROUNDED. ACCOMPLISHED SYSTEM TEST REF AMM 30-31-00. VERIFIED OPS CHECK NORMAL.SDR ASAA2015060912040Warning Light · false activationRIGHT ALPHA VANE LIGHT ILLUMINATED MOMENTARILY. ACFT GROUNDED. UNABLE TO DUPLICATE. RIGHT AOA HEATER CHECKS OK REF AMM 30-31-00-736-801.SDR ASAA2015060912039Idg · failedAFTER STARTING LT ENGINE-GENERATOR WOULD NOT COME ON LINE -NEGATIVE FREQUENCY AND VOLTS. ACFT GROUNDED. AFTER ENG RUN FOUND NO SOURCE VOLTS, FREQUENCY WITH GCU FAULT 1 IDG. R & R 1 ENGINE IDG REF MM 24-11-11-000-801 AND 24-11-00-700-802.SDR ASAA2015060812030Fuel Feed · faultedDURING ACCOMPLISHMENT OF T/C 78273000, LONG TIME FAULT MSG 73-31072, FUEL FLOW SIGNALS DISAGREE. NR 2 ENGINE LEG 2. ACFT GROUNDED. ON DEFERRAL.SDR ASAA2015060812028Warning Light · illuminatedNR 1 SOURCE OFF LIGHT ILLUMINATED. NO VOLTS/ FREQUENCY IN CRUISE AT 36,000 FT. ACFT GROUNDED. ACCOMPLISHED GCU BITE TEST NR 1 IAW FIM 24-21, TASK 801, AND RESET. C/W FIM 24-21, TASK 823 SOURCE OFF LIGHT ILLUMINATED AFTER NR 1 ENGINE GROUND RUN, GROUND VERIFSDR ASAA2015060812027Satcom · lockedSATCOM LOCKED UP. ACFT GROUNDED. RESET SATCOM SYS IAW FIM TASK 23-15, TASK 801. OPS RESTORED.SDR ASAA2015060712015Sign · brokenEMERGENCY LIGHT EXIT LOCATOR SIGN ADJACENT TO L-1 DOOR IS BROKEN. ACFT GROUNDED. REMOVED, REPLACED, AND TESTED EXIT LOCATOR SIGN LIGHT ASSY IAW MM 33-51-01-960-802. OPS NORMAL.SDR ASAA2015060712014Regulator · failedDURING CLIMBOUT, OBSERVED RT PACK PRESSURE INDICATION FLUCTUATIONS, WITH THE LT PACK INDICATION STABLE AT 32 PSI. THE RT PACK NEEDLE WAS OCCILATING BETWEEN APPROXIMATELY 37 TO 46 PSI IN CYCLES OF APPROXIMATELY 1 TO 2 SECONDS. THIS OBSERVATION STAYED CONSISTENSDR ASAA2015060712013Warning Message · false activation"FMC DISAGREE" ALERT ON GROUND. ACFT GROUNDED. FOLLOWED QRH. SYSTEM RESET NORMALLY.SDR ASAA2015060712010Satcom · lockedSATCOM LOCK-UP. ACFT GROUNDED. COMPLIED WITH QRH, OPS NORMAL.SDR ASAA2015060611993Window · failedON FINAL THE RT SIDE WINDOW HEAT OVERHEAT ILLUMINATED. COMPLETED THE QRH CHECKLIST AND OVERHEAT LIGHT EXTINGUISHED. LINE MAINTENANCE ADVISED. ACFT GROUNDED. BITE TESTED RT SIDE WHCU REF FIM 30-41, TASK 801. TEST OK. LAST FLIGHT LEG HAS FAULT FOR SENSOR. SDR ASAA2015060611992Warning Light · malfunctionedL2 WINDOW HEAT LIGHT EXTINGUISHED WHILE ALL OTHER LIGHTS REMAINED ON. SUNLIGHT WAS NOT AN ISSUE. ACFT GROUNDED. PERFORMED WINDOW HEAT CONTROL UNIT BITE PROCEDURE ON L2 WINDOW IAW AMM TASK 30-41, TASK 801. NO FAULTS NOTED. NO HISTORY 30 DAYS.SDR ASAA2015060611984Satcom · lockedSATCOM LOCK-UP. ACFT GROUNDED. COMPLIED WITH QRH, OPS NORMAL.SDR ASAA2015060611983Satcom · lockedSATCOM LOCK-UP WITH POWER TRANSFER. ACFT GROUNDED. QRH PROCEDURE COMPLETED SUCCESSFULLY.SDR ASAA2015060611981Warning Light · false activationON MASTER CAUTION RECALL, RT PACK LIGHT ILLUMINATES. RESETS ON RECALL. ACFT GROUNDED. BITE CHECK OF NR 2 PACK/ZONE TEMP CONTROLLER LOGGED "TCV", FAULT RESETS. FIVE ADDITIONAL BITE CHECKS, NO FAULTS LOGGED.SDR ASAA2015060611979Actuator · faultedBITE TEST OF NR 1 PACK /ZONE TEMPERATURE CONTROLLER LOGS RAM AIR DOOR "ACTUATOR FAULT". ACTUATOR FAULT WILL NOT RESET IAW AMM TASK 21-51-00-700-803. ACFT GROUNDED. REPLACED LT RAM AIR INLET ACTUATOR REF AMM 21-51-21-401. OPS CHECKS GOOD.SDR ASAA2015060611978Control Valve · malfunctionedFWD CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXT ON MAST CAUTION RESET. ACFT GROUNDED. VERIFIED ZONE TRIM FAULT ON THE NR 2 ZONE TEMP CONTROLLER. REPLACED THE FORWARD CABIN ZONE TRIM MODULATING VALVE IAW AMM'S 21-61-21-000-801 AND 21-61-21-400-801. VALVESDR ASAA2015060512000Exciter · failedON NR 2 ENGINE START W/R IGNITION DID NOT GET LIGHT OFF. ACFT GROUNDED. REPLACED AND OPS CHECKED NORMAL NR 2 ENGINE RT IGNITION EXCITER BOX REF AMM 74-11-01. ACCOMPLISHED 2 ENGINE STARTS ON NR 2 ENGINE WITH NO DEFECTS NOTED.SDR ASAA2015060512001Engine · faultedREF T/C 78273000, NR 2 ENG FAULT 77-20872. TOP LT EGT SIGNAL T495S4 IS OUT OF RANGE. ACFT GROUNDED.SDR ASAA2015060511999Regulator · failedAFTER NR 2 ENGINE START, TURNED ON RT PACK & AIR CONDITIONER BLEED AIR VALVE RT CIRCUIT BREAKER OPENED. ACFT GROUNDED. REPLACED NR 2 ENGINE BLEED AIR REGULATOR REF AMM 36-11-03-400-801. OPS AND LEAK CHECKED GOOD.SDR ASAA2015060511990Circuit Breaker · trippedGENERATOR NR 1 DISC CIRCUIT BREAKER TRIPPED. ACFT GROUNDED. CHECKED HISTORY. NO HISTORY 90 DAYS. RESET CIRCUIT BREAKER ON P6-4 GENERATOR DISC 1, IAW WDM 24-11-11 AND MM 20-60-01. RAN NR 1 ENGINE AND OPS TESTED DISCONNECT FOR NR 1 IDG. OPS NORMAL. RESET ISDR ASAA2015060511988Satcom · lockedSATCOM LOCK-UP DURING POWER TRANSFER. ACFT GROUNDED. QRH PROCEDURE COMPLETED, OPS RESTORED.SDR ASAA2015060511987Warning Message · false activationFMC DISAGREE ON TAXI OUT. ACFT GROUNDED. QRH FOLLOWED, OPS NORMAL.SDR ASAA2015060511980Module · failedAFTER ENGINE START DURING RECALL "AIR COND" LIGHT ILLUMINATES ALONG WITH "ALL" 3 ZONE TEMP LIGHTS. NO TEMP CONTROL. "AIR COND" LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. FLT DECK AND ZONE SELECTOR FAULTS ON BOTH ZONE TEMP CONTROLLERS. REPSDR ASAA2015060511976Circuit Breaker · malfunctionedNO SATCOM PROMPT ON FMC CDU MENU PAGE. ACFT GROUNDED. CYCLED SATCOM CIRCUIT BREAKER AS REQUIRED, OPS CHECK NORMAL IAW FIM 23-15, TASK 801.SDR ASAA2015060411998Valve · failedRIGHT DUCT PRESSURE READS 5 PSI IN FLIGHT GROUNDED. RETURNED TO DEPARTURE. DIVERSION TIME - 38 MINUTES. PERFORMED ENGINE BLEED HEALTH CHECK REF. T/C NG-36WC-00001 IAW STEP .04, HIGH STAGE VALVE FAILED WRENCH CHECK. REPLACED NR 2 ENGINE HIGH STAGE VALVE IAWSDR ASAA2015060411996Keyboard · wornF/O MCDU, CONTROL DISPLAY UNIT, BUTTON 6L COMING OFF. ACFT GROUNDED. REPLACED F/O MCDU KEYPAD. INSTALLATION TEST PASSES. REF AMM 34-61-01-400-801.SDR ASAA2015060411991Sensor · failedWINDOW HEAT, RIGHT SIDE OVERHEAT LIGHT ON. ACFT GROUNDED. RIGHT SIDE WINDOW PRIMARY SENSOR OPEN. MOVED "D" TERMINAL TO SPARE TERMINAL. WHCU UNIT BITE VERIFY CHECK PASSES. REF FIM 30-41, TASK 811.SDR ASAA2015060411986Satcom · lockedSATCOM LOCKOUT ON POWER TRANSFER. ACFT GROUNDED. QRH PROCEDURE CORRECTED PROBLEM.SDR ASAA2015060411985Hf Comm · malfunctionedHF1 AND HF2 BOTH SHOW INOPERATIVE ON BOTH RADIO CONTROL PANELS. ACFT GROUNDED. PERFORMED RADIO TUNING PANEL, INOPERATIVE DISPLAY TOGGLE IAW TC AMM 23-12-41-800-802. OK FOR SERVICE.SDR ASAA2015060411982Satcom · malfunctionedNO SATCOM PROMPT ON THE GROUND. ACFT GROUNDED. PERFORMED SATCOM LOCKOUT PROCEDURE, SATCOM CAPABILITY RESTORED.SDR ASAA2015060411977Warning Light · false activationDURING PREFLIGHT, NOTICED GREEN ALTN LIGHT ILLUMINATED ON OVERHEAD PRESSURIZATION PANEL ALSO AMBER AUTO FAIL LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED BITE ON CABIN PRESS CONTROLLERS OPS NORMAL, NO DEFECT NOTED, ALTN GREEN LIGHT AND AMBER AUTO FAIL LIGHT ESDR ASAA2015060411964Beam · gougedRT CENTER WING BEAM SPANWISE LOWER CHORD DAMAGED BY ECS DOOR LATCH. ACFT GROUNDED. REPLACED LOWER CHORD.SDR ASAA2015060311955Warning Light · illuminatedLEFT PACK ILLUMINATES DURING RECALL, EXTINGUISHED ON RESET. ACFT GROUNDED.SDR ASAA2015060311961Warning Light · false activationRT ALPHA VANE LIGHT ILLUMINATED BREIFLY CLIMBING THROUGH 10,000 MSL. MASTER CAUTION LIGHT WAS RESET AND RT ALPHA VANE LIGHT EXTINGUISHED. ACFT GROUNDED. PERFORMED OPS TEST IAW MM 30-31-00-730-801 NO DEFECTS NOTED, OPS NORMAL, NO HISTORY PAST 30 DAYS.SDR ASAA2015060311956Warning Light · false activationRIGHT PACK LT ILLUMINATED DURING CLIMB IAW QRH RESET. ACFT GROUNDED. PERFORMED PACK ZONE TEMP CONTROLLER BITE TEST. NO FAULT FOUND. GROUND VERIFICATION COMPLETE REF AMM 21-61-00. NO HISTORY LAST 30 DAYS.SDR ASAA2015060311954Satcom · malfunctionedSATCOM PROMPT DISAPPEARED AT POWER TRANSFER. ACFT GROUNDED. ACCOMPLISHED QRH PROCESS NORMAL, OPS RESTORED.SDR ASAA2015060212046Channel · crackedAFT CARGO COMPARTMENT RT TRANSITION PANEL IS CRACKED AT BS 727H. ACFT GROUNDED. REPAIRED AFT CARGO COMPARTMENT RT TRANSITION PANEL AT BS 727H IAW SRM 53-00-53-2R-5, REPAIR 5.SDR ASAA2015060211969Channel · puncturedAFT CARGO COMPARTMENT, LT SIDEPLATE CHANNEL IS PUNCTURED AT APPROXIMATELY BS 753. ACFT GROUNDED. REPAIRED LT SIDE PLATE CHANNEL AT APPROXIMATELY BS 753 IAW SRM 53-0-53-22R-5.SDR ASAA2015060211968Floor Support · crackedFWD CARGO COMPARTMENT, RIGHT FLOOR SUPPORT BAFFLE BS 500A-500B IS CRACKED. ACFT GROUNDED. R & R RT FLOOR SUPPORT BAFFLE BS 500A-500B IAW ASA 737-800, SRM 51-10-02, PARA 9 AND 51-40-02, AND BAC DWG 143A7505, REV A .SDR ASAA2015060211967Shield · corrodedAFT CARGO COMPARTMENT, FWD DOOR SURROUND SHIELD IS CORRODED, APPROXIMATELY BS 767-BS 787. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-60-15-1A-1, ORIGINAL THICKNESS IS .050 IN REMAINING THICKNESS IS .039 IN REMOVED .011 IN, SDR ASAA2015060211951Control Panel · dimHEADING DISPLAY WINDOW ON MCP IS VERY DIM. ACFT GROUNDED. REPLACED AND TESTED MODE CONTROL PANEL REF MM 22-11-34. OPS NORMAL. PERFORMED DFCS GROUP 32, DFCS LRU INTERFACE TEST FOR MCP REF MM 22-11-34/501, DFCS GROUP NR 49, LAND VERIFY TEST, REF MM 22-11-00/SDR ASAA2015060211952Satcom · inoperativeINOPERATIVE SATCOM. ACFT GROUNDED. FINISHED THE CHECKLIST, ACFT BACK TO NORMAL.SDR ASAA2015060211950Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATES DURING MASTER CAUTION RECALL. EXTINGUISHES WHEN MASTER CAUTION IS RESET. ACFT GROUNDED. INTERROGATED NR 2 PACK ZONE TEMP CONTROLLER: 2 HARD FAULTS FOUND-- TEMP CONTROL VALVE & FWD PASS COMP ZONE TEMP VALVE. REF: AMM 21-61-00. RSDR ASAA2015060112048Channel · corrodedAFT CARGO BAY RT SIDEPLATE CHANNEL IS CORRODED APPROXIMATELY BS 727D TO 767. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2. ACCOMPLISHED A SPLICE REPAIR IAW SRM 53-00-53-2R-5.SDR ASAA2015060112006Floor Panel · puncturedPARTS RACK, FWD CARGO COMPARTMENT, FLOOR PANEL 120CF IS PUNCTURED. ACFT GROUNDED. FABRICATED NEW PANEL 120CF IAW DWG 453A1610, SHEETS 51 & 52 REV A, ALODINED AND PRIMED IAW SRM 51-20-01.SDR ASAA2015060112005Floor Panel · puncturedAFT CARGO COMPARTMENT, FLOOR PANEL 140BF IS PUNCTURED. ACFT GROUNDED. FABRICATED A NEW FLOOR PANEL NR 140-BF IAW BAC DWG 453A2610, REV "E".SDR ASAA2015060112003Channel · corrodedFWD CARGO COMPARTMENT, RT SIDEPLATE CHANNEL IS CORRODED. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND BEYOND ALLOWABLE LIMITS OF 10 PERCENT THICKNESS MAX IAW SRM 53-00-53-1S-2. ORIGINAL MATERIAL THICKNESS WAS 0.040 IN; REMOVED 0.013 IN; REMAINING THICKNES
Back to Boeing 737-890