Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2013012593749Regulator · failedONE MINUTE AFTER BEGINNING DESCENT FROM 40,000FT, NR 2 BLEED TRIP OFF ILLUMINATED. RESET OK. THROTTLES WERE AT 65 N1 WHEN TRIP OCCURRED. ACCOMPLISHED FIM TASK 36-10, TASK 801. TS & ACCOMPLISHED NR 2 ENG BLEED AIR SYS HEALTH CHECK IAW T/C NG-36WC-000001. SDR ASAA2013012593748Fmc · illuminatedFMC DISAGREE ILLUMINATED AFTER ENGINE START. PERFORMED QRH, OPS NORMAL.SDR ASAA2013012593745Controller · malfunctionedCONTROL CAB ZONE TEMP LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. PERFORMED AN OPS CHECK OF THE PACK SYSTEMS IAW AMM 21-00-00. ALSO, PERFORMED A BITE CHECK OF THE ZONE TEMP CONTROLLERS. NO FAULTS NOTED. OK FOR SERVICE.SDR ASAA2013012493753Ignition Lead · failedAPU FAILED TO START. NO FLAME SHUTDOWN FAULT CODE 49-41011. REPLACED APU IGNITION UNIT REF AMM 49-41-31. REPLACED APU IGNITER PLUG REF AMM 49-41-51. REPLACED APU IGNITER PLUG LEAD REF AMM 49-41-52. PERFORMED APU IGNITION UNIT, IGNITER PLUG AND IGNITER PLUSDR ASAA2013012493752Packing · leakingFUEL LEAK COMING FROM THE APU. ACFT GROUNDED. FOUND FUEL LEAK FROM FCU FUEL SUPPLY LINE NEAR TUBE RETAINER. REPLACED FUEL SUPPLY LINE O-RINGS AND HARDWARE IAW AMM 49-31-11. RUN APU FOUND NO LEAKAGE, ALL OPERATIONS NORMAL.SDR ASAA2013012493747Actuator · inoperativeFUEL CROSSFEED VALVE TRIPPED IN FLIGHT. CROSSFEED VALVE HAD BEEN CLOSED AND HAD NOT BEEN OPENED BY PILOTS. WHEN CENTER TANK EMPTIED OF FUEL, IMBALANCE BEGAN TO BE EVIDENT. SURMISED THAT VALVE HAD OPENED AND WAS NOW STUCK OPEN. BALANCE MAINTAINED BY SELECTIVSDR ASAA2013012493742Control Valve · malfunctionedRT PACK LIGHT ILLUMINATED. MASTER CAUTION RESET EXTINGUISHED LIGHT IAW QRH 2.7. ACFT GROUNDED. NR 2 TEMP CONTROLER SHOWS THIS PACK-TCV FAULT. R & R NR 2 TEMP. CONT VALVE REF AMM 21-51-10-000-801. LK & OPS CKD GOOD. BITE TEST PASS REF AMM 21-61-00-700-8SDR ASAA2013012493741Control Valve · malfunctionedON MASTER RECALL THE RT PACK LIGHT ILLUMINATED, LIGHT EXTINGUISHED ON RESET. REPLACED RT TCV IAW AMM 21-51-10-000-801. OPS CK GOOD BITE CK GOOD.SDR ASAA2013012393738Flow Divider · failedCSS PASSED WITH FAULT LIGHT ON FIRST ATTEMPTED FL 390. SECOND ATTEMPT STARTED BETWEEN FL 380 AND FL 350 APU STARTED FINE. ACFT GROUNDED. IAW POWERPLANT ENG REQUEST ACCOMPLISHED TASK 49-60, TASK 899 WITH FOLLOWING RESULTS FAULT HISTORY PAGE SHOWS 49-31016 JASDR ASAA2013012393728Shroud · missingDURING ACCOMPLISHMENT OF IGNITOR PLUG T/C 78474000 FOUND THE NR 1 ENG IGNITER PLUG RT POSITION COOLING SHROUD MISSING. REPLACED NR 1 ENGINE RT POSITION COOLING SHROUD, REF T/C 78474000.SDR ASAA2013012393727Duct · splitOBSERVED DUCT PRESSURE SPLIT AT CRUISE AT FL 370. LT PRESSURE 23, RT PRESSURE 43 N1 92.8 LT & RT, N2 95.4 LT & RT. ACFT GROUNDED. INSTALLED SERVICEABLE PRSOV IAW MM 36-11-04-400-801, 12292. INSTALLED SERVICEABLE HIGH STAGE REGULATOR IAW MM 36-11-07-400-801.SDR ASAA2013012393726Warning Light · false activationCONT CAB ZONE TEMP ILLUMINATED ON RECALL AFTER ENG START ACCOMPLISHED GROUND CHECKLIST. AFTER SELECTING COOLER TEMP AND PUSHING TRIP RESET ZONE TEMP LIGHT STAYED ILLUMINATED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-62. NO DEFECTS NOTED.SDR ASAA2013012293739Actuator · faultedLEFT PACK LIGHT ILLUMINATED ON RECALL, LIGHT GOES OUT WITH MASTER CAUTION, RESET. ACFT GROUNDED. ACCOMPLISHED BITE TEST ON NR 1 CONTROLLER REF AMM TASK 21-60-00, LOGGED RAM AIR ACTUATOR FAULT, R & R LT RAM AIR DOOR ACTUATOR REF AMM TASK 21-51-21. OPS CK NSDR ASAA2013012293723Engine · damagedNR 2 ENGINE TREND DATA SHOWS A SUDDEN SHIFT IN EGT (TAKEOFF AND CRUISE), FUEL FLOW AND DELTA CORE SPEED. CORE SPEED AND EGT ARE CURRENTLY WITH ETOPS LIMITS. NR 2 ENGINE VBV GUIDE PAD UNDER NR 9 FAN DUCT PANEL IS DISBONDED. (REF AMM 75-32-00-200-801-F00) ACFT SDR ASAA2013012193718Probe · corrodedREF T/C N8420001 T49.5 S2 AND S4 PROBES, PINS HAVE CORROSION/CONTAMINATION AND REQUIRE REPLACEMENT IAW AMM70-70-01-200-801-F00. RT ENGINE. ACFT GROUNDED. ACCOMPLISHED ALTERNATE DEACTIVATION 05-07-01, TABLE 3, ITEM 1. REPLACED S2 AND S4 T49.5 PROBES AT NR 2 SDR ASAA2013012193717Buss · malfunctionedSTARTED APU ON LANDING ATTEMPTED TO BRING APU ELECTRICAL POWER ON BUSSES AND WOULD NOT HOLD AFTER 2ND BUSS ATTEMPTED ON TWO ATTEMPTS, ATTEMPTED TO PROVIDE APU BLEED AIR AT GATE ALSO AND THERE WAS ZERO APU BLEED DUCT PRESSURE. APU BITE PROCEDURE AMM TASK 49-60SDR ASAA2013012193716Warning Light · false activationLT PACK ILLUM ON CLIMBOUT. RAN QRH, OPS NORMAL. BITE TEST, FLT HISTORY & VERIFY ALL TESTS PASS ON BOTH LT & RT CONTROLLERS. FIM TASK 21-52-820 INITIAL EVALUATION INDICATES NO FAULT. NO LT PACK FAULTS LAST 30 DAYS.SDR ASAA2013012193715Modulating Valve · failedRT PACK FAILED IN FLIGHT. ACFT GROUNDED. BITE TEST OF NR 2 ZONE TEMP CONTROLLER HAS FAULT TCV THIS PACK. REPLACED RT TCV IAW AMM 21-51-10-000-400-801. BUBBLE TEST REVEALED NO AIR LEAKS. RT PACK TEMP CONTROLLER BITE NORMAL - NO CURRENT FAULTS REF 21-61-00. PSDR ASAA2013012093724Actuator · faultedWHILE PERFORMING TASK CARD 78273000, INTERROGATED FMC CDU FOR ENGINE FAULTS. THE NR 1 ENGINE SHOWS FAULT 75-10391 THE VSV POSITION SIGNAL IS OUT OF RANGE. THIS IS A 450 HOUR, LONG TIME FAULT.SDR ASAA2013012093719Igniter · inoperativeAPU INOP, DUE TO NO FLAME SHUTDOWN, FAULT CODE 49-41011. ACFT GROUNDED. PERFORMED FIM TASK 49-40 TASK 802 BITE CHECKS NO CURRENT FAULTS, START/OPERATION/SHUTDOWN CHECKS GOOD, INLET PLENUM AND COMPRESSOR INLET CLEAR. BITE CHECKS GOOD 5 START CYCLES, NO HISTORSDR ASAA2013012093705Warning Light · false activationDURING LANDING CHECK, RT PACK ILLUMINATED ON RECALL. RESET SYS AND RAN PACK/ ZONE TEMP CONTROLLER BITE TEST FOR THE RT PACK, GROUND FUNCTIONAL TESTED GOOD IAW AMM 21-61-00-700-806-002.SDR ASAA2013012093703Filter · dirtyCONT CAB LIGHT ON RECALL ZONE TEMP. BITE TEST OF PACK/ZONE TEMP CONTROLLERS SHOWED NO FAULTS AND VERIFY TEST PASSED FOR BOTH WITH NO TRIM VALVE FAULTS. FOUND CONTROL CABIN ZONE TEMP SENSOR AND FILTER VERY DIRTY. CLEANED TEMP SENSOR IAW MM 21-61-10-100-801 ANSDR ASAA2013012093700Converter · failedATTEMPTED TO PLACE APU GENERATOR ON BUSS FROM GROUND POWER, CPS FREQ AN AC VOLTS SHOWED ZERO WITH GENERATOR SELECT SWITCH IN APU GEN POSITION. GROUND POWER SWITCH CONFIRMED ON. APU GEN SHOWED FREQ AND VOLTS (400/116). PLACED APU ON GEN AND POWER TRIPPED OFF.SDR ASAA2013011993730Transition Panel · crackedAFT CARGO BAY RT FLOOR TRANSISTION PANEL (SIDE PLATE) CRACKED BS 727I AND 727J. ACFT GROUNDED. FABRICATED REPAIR PART S IAW SRN 53-00-53 REATED AND PRIMED IAW SRM 51-20-01. INSTALLED REPAIR IAW SR, 53-00-53.SDR ASAA2013011993706Autoland Sys · malfunctionedAUTOLAND FAILED, TOUCHDOWN WAS GREATER THAN 35 LT OF CENTERLINE, BUT IN THE TOUCHDOWN ZONE OF THE RUNWAY. NO FAULT LOGGED IN DFCS FFR, CURRENT STATUS PASSED. PERFORMED LAND VERIFY TEST REF FIM 22-11 TASK 825. ACFT REMAINS CAT IIIA AUTOLAND & HGS QUALIFIED, SSDR ASAA2013011993704Warning Light · false activationAFTER LANDING, DURING TRANSFER FROM ENGINE GENERATOR TO APU POWER, PRESSURIZATION AUTOFAIL AND ALTN LIGHTS CAME ON. FOUND LRU FAIL OFV OII ON NR 2 DCPC. RESET IAW FIM TASK 21-31, TASK 802. ALL FAULTS CLEARED AND DID NOT RETURN. BOTH NR 1 AND NR 2 DCPCS CHECSDR ASAA2013011793725Support · corrodedFWD CARGO COMPARTMENT AFT BULKHEAD LOWER SUPPORT CORRODED. REMOVED LOWER SUPPORT 2 ANGLE FROM FWD PIT AFT BULKHEAD IAW SRM 51-50-02. LOCATED, DRILLED, AND DEBURRED NEW ANGLE IAW SRM 51-40-05. INSTALLED NEW Z ANGLE IAW SRM 51-40-02, CICD AREA IAW AMM 51-21-91.SDR ASAA2013011793707Circuit Breaker · trippedON PREFLIGHT, FOUND HF 2 CIRCUIT BREAKER TRIPPED. RESET HF 2 CIRCUIT BREAKER IAW AMM 20-60-01. CIRCUIT BREAKER REMAINS RESET. NO DEFECTS NOTED. PERFORMED HF 2 COMMUNICATION SYS TEST IAW AMM 23-11-00. SUCCESSFUL GROUND OPS CHECK. NO DEFECTS NOTED.SDR ASAA2013011793702Ecu · faultedWHILE PREFORMING FMC-CDU T/C FOUND FAULT CODE 76-31362 FOR THE NR 2 ENGINE, START LEVER SIGNALS DISAGREE LONG TERM FAULT. R & R NR 2 ENG EEC. REF MM 73-21-60-000-801-FOO AND 73-20-60-400-801-FOO. PERFORMED FADEC SYS TEST REF MM 73-21-00-700-802-F00. EEC SOSDR ASAA2013011793701Module · leakingDURING ETOPS PDC FOUND OIL STREAMING OUT OF APU COWLING DRAIN MAST. REPLACED APU LUBE MODULE REF AMM 49-91-11-400-802, OPS CHECKED GOOD.SDR ASAA2013011793688Fastener · looseNR 1 ENGINE FAN DUCT PANEL FASTENER FOUND LOOSE AND RETORQUED SCREWS ON ALL PANELS IAW AMM 72-23-07.SDR ASAA2013011693699Valve · failedON DEPARTURE NOTICED DUCT SPLIT. PERFORMED ENGINE BLEED AIR HEALTH CHECK ON NR 2 ENGINE IAW TASK CARD NG-36WC-00001, SYS PASSED ALL CHECKS. HSV SEEMED TO RATCHET SLIGHTLY UPON OPEN AND CLOSED SO PART WAS REPLACED. REMOVED HSV REF AMM 36-11-06-000-801, REPLSDR ASAA2013011693692Window · crackedF/O R2 WINDOW HAS .5" CRACK IN UPPER FORWARD CORNER OF OUTER PANE. REMOVED NR 2 RT SLIDING WINDOW. INSTALLED NEW R2 F/O SLIDING WINDOW REF MM TASK 56-12-11-400-801. OPS CHECKED GOOD AND LEAK CHECKED IAW 78256003, ACCOMPLISHED.SDR ASAA2013011693691Control Valve · malfunctionedON RECALL, DURING LANDING CHECK, LT PACK LIGHT ILLUMINATED, EXTINGUISHED WITH RESET. PERFORMED LT PACK TEMP CONTROLLER BITE CK, REF FIM 21-62, TASK 801. LOGGED TCV FAULT LAST FLT NO HISTORY LAST 60 DAYS. PERFORMED FIM 21-62, TASK 830 TCV FAULT ISOLATION & FSDR ASAA2013011693690Control Valve · malfunctionedLT PACK LIGHT ILLUMINATES ON RECALL. RESETS WITH MASTER CAUTION RESET. TESTED LT PACK TCV LOGGED AS A FAULT. CLEARED FAULT AND RE-TESTED IAW AMM 21-61-00. NO FAULTS INDICATED. RAN LT PAC WITH NO PROBLEMS OR FAULTS. NO FAULT HISTORY FOR THE LT SYS WITHIN SDR ASAA2013011693689Actuator · faultedON FINAL APPROACH PACK LIGHT FOR LT A/C PACK ILLUMINATED ON RECALL. WAS ABLE TO RESET WITH MASTER CAUTION. VERIFIED PACK LIGHT ILLUMINATES ON RECALL AND WILL EXTINGUISH WITH RESET. RAN BITE CHECK ON BOTH TEMP CONTROLLERS, RAM AIR ACTUATOR FAULT SHOWED FOR LSDR ASAA2013011693675Probe · out of limitsDIAGNOSTICS REPORTS NR 2 ENGINE TREND DATA CONTINUES TO SHOW A SHIFT IN DELTA CRUISE AND TAKEOFF MARGIN INDICATIVE OF EGT INDICATION ERRORS. ACCOMPLISHED T49.5 PROBE AND EGT SYS INSPECTION IAW MM 77-21-00-200-801-F00. ALL RESISTANCES AND INSULATION RESISTANCSDR ASAA2013011593685Light · inoperativeNR 1 MAIN FUEL TANK REFUEL VALVE INDICATION LIGHT IS INOPERATIVE. REPLACED NR 1 REFUEL VALVE LIGHT ASSY WITH NEW 1. ACCOMPLISHED REFUEL PANEL OPS TEST, TEST PASSES. REF MM 28-41-61-400-801 & WDM 28-44-11.SDR ASAA2013011593683Fmc · malfunctionedAPPROX 17.5 E OF OGG VOR. LT FMC FAILED, VTK FLAG APPEARRIED ON CAPTS INBD DU, LT FMC BLANKED AND ROLL QUIDANCE LOST FOR 45 SECONDS FMC RECOVERED ON ITS OWN, QRC FOLLOWED . OPERATED NORMALLY REMAINDER OF FLT. PERFORMED FIM 34-61, TASK 836, NR 1 FMC SHOWS NO SDR ASAA2013011493687Shutoff Valve · wornLT ENG PRSOV STUCK OPEN WITH ENGINE OFF. PERFORMED TROUBLESHOOTING TASK 36-00-00-860-807, SECTION C, DETERMINED PRSOV VALVE TO BE WORN EXCESSIVELY. REMOVED PRSOV VALVE ON NR 1 ENGINE REF AMM 36-22-04-000-801. INSTALLED PRSOV VALVE ON NR 1 ENGINE REF AMM 36-SDR ASAA2013011493681Unknown · unknownINITIAL FUEL LOAD ON ACFT WAS INCORRECT, MAIN TANKS NOT FUELED TO FULL IN CENTER TANKS. PERFORMED FUEL QUANTITY OP TEST REF AMM 28-41-00-710-801, NO FAULTS FOUND, NO CURRENT FAULTS FOUND, SYS VERIFIED WITH FUEL STICK VERSUS FLT DECK IND, WITHIN LIMITS IAW AMMSDR ASAA2013011493679Lamp · failedEMERGENCY LIGHT OUT, ROW 8 CBA SIDE. R & R WITH NEW LAMP IAW AMM 33-51-43, STEP 2 EMERGENCY LIGHT AT ROW 8 CBA, PERFORMED GROUND OPS CHECK.SDR ASAA2013011493678Lamp · failedEMERGENCY EXIT LIGHT AFT OF L2 WILL NOT ILLUMINATE. REPLACED LAMP IAW AMM 33-51-04-960-801, 33-51-06-960-805.SDR ASAA2013011493677Control Valve · faultedAT FL 340, PUSHED MASTER CAUTION RECALL AND THE RT PACK LIGHT ILLUM ON THE OVERHEAD, FOLLOWED THE QRH, INDICATES PRIMARY OR SECONDARY CONTROL FAILURE NO FURTHER ACTION REQ. PERFORMED NR 2 PACK TEMP CONTROLLER BITE CK REF FIM 21-62, TASK 801, LOGGED TCV FAULTSDR ASAA2013011493676Warning Light · false activationCONT CAB ZONE TEMP ILLUMINATES ON RECALL & EXTINGUISHED ON RESET. VERIFIED FAULT FOR CABIN RECALL. ACCOMPLISHED PACK/ ZONE TEMP CONT BITE NR 1 CONT NO FAULTS. NR 2 CONT FAULTED FLT DECK TRIM VALVE (V143). CLEARED FAULT, ACCOMPLISHED CABIN TEMP CONT & IND OSDR ASAA2013011393884Seat Track · wornMAIN CABIN BS 520, RBL 24, SEAT TRACK UPPER CROW IS WORN. CLEANED AREA IAW NG 20-30-88, BLENDED AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-00-52, FIG 202. REPAIR 4. CUT AND TRIMMED DAMAGE SECTION OF SEAT TRACK IAW SRM 53-00-52, FIG 202, PG 109. LOCATED, DRSDR ASAA2013011393682Brake Assy · shortedLEFT ENGINE VALVE CLOSED LIGHT ILLUMINATED BRIGHT BLUE. LT ENGINE INDICATIONS NORMAL TROUGHOUT, LIGHT WENT OUT. CAME BACK ON, REMAINED ON THROUGH DECENT, LANDING AND TAXI TO GATE. DISCONNECTED D626 AND HMU DP1207, READ PIN 12, D626 TO GROUND, OPEN CIRCUIT TSDR ASAA2013011393670Relay · inoperativeLOW PRESSURE LIGHT FOR THE CENTER TANK LT FUEL PUMP FAILS TO COME ON. REF T/C 78128006, PARA. D. (9)-(11). FOUND R936 RELAY BAD. REPLACED R936 REF WDM 28-23-11. NOW T/CS 78128006 AND 78128007, OPS NML.SDR ASAA2013011393669Warning Light · false activationRT PACK LIGHT ILLUMINATES ON RECALL. ACCOMPLISHED CABIN TEMP CONTROLLER BITE IAW AMM REF 21-61-00, OPS CHECKED NORMAL. GROUND VERIFICATION SUCCESSFUL.SDR ASAA2013011293674Cover · dislodgedFORWARD ENTRY EMERGENCY LIGHT COVER FELL OFF. REPLACED LIGHT COVER AND LIGHT ASSY.
Back to Boeing 737-890