Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2012123093581Charger · malfunctionedDURING PREFLIGHT OVERHEAD ELEC LIGHT WAS ILLUMINATED. ACCOMPLISHED P5-13 BITE PROCEDURE IAW FIM TASK 24-31, TASK 801. FOUND FAULT MESSAGE FOR BATTERY CHARGER INOPERATIVE. CLEARED FAULT. ACCOMPLISHED BATTERY CHARGER OPERATIONAL TEST IAW AMM 24-31-21-710-80SDR ASAA2012123093579Autoland Sys · malfunctionedAUTOLAND FAILED - FLAIR WOULD NOT ARM. ACCOMPLISHED DFCS FAULT REVIEW BG 20 FOR 30DEC12. NO RELEVANT FLIGHT LEG FAULTS AND ALL FAULT LRU TESTS PASS 20.01, 20.18, 20.24. ALSO ACCOMPLISHED LAND VERIFY BG 49. ALL TESTS PASS.SDR ASAA2012123093577Control Valve · faultedRT PACK LIGHT ILLUMINATES ON RECALL OF M/C SYS, LIGHT GOES OUT WITH RESET. BITE CHECKED FAULTED RT PACK TCV. REPLACED RT PACK TCV. REF AMM 21-51-10. OPS CK, NO FAULTS FOUND. LEAK CK, NO LEAKS NOTED.SDR ASAA2012122993575Oil System · lowMAINTENANCE LIGHT ILLUMINATED ON APU CONTROL PANEL. ACCOMPLISHED APU BITE PROCEDURE IAW 49-60, TASK 801. FOUND FAULT CODE 49-91227. SERVICED APU OIL. MAINTENANCE LIGHT EXTINGUISHED. APU LEAK & OPS CHECKED GOOD. NO FAULTS DISPLAYED. OK FOR SERVICE.SDR ASAA2012122993570Indication Sys · malfunctionedFUEL HAS DECREASED 600 LBS IN 15 MINUTES WITH NO ENGINES OR APU RUNNING. ACCOMPLISHED FUEL QTY, OPS TEST IAW 28-41-00, ALSO PERF FQIS COMPARISON CHECK WITH STICKS IAW 28-41-00, ALL TANKS WELL WITHIN TOLERANCE. NO FAULTS LOGGED, ALL CK NORMAL.SDR ASAA2012122993566Controller · faultedCONT CAB ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHED WITH MASTER CAUTION RESET. PERFORMED FIM 21-62, TASK 842. BITE TEST OF NR 2 ZONE TEMP CONTROLLER HAS FAULT, FLT DECK TRIM VALVE . CLEARED FAULT AND RAN PACKS. FAULT DID NOT RETURN. INTERMITTENT FAULT IAW SDR ASAA2012122993565Control Valve · failedWITH MASTER RECALL, LT PACK LIGHT COMES ON, GOES OUT WITH RESET. REPLACED LT TEMP CONTROL VALVE IAW MM 21-51-10-000-801 AND 21-51-10-400-801. OPS CHECKED GOOD. NO LEAKS NOTED.SDR ASAA2012122993564Control Valve · faultedLEFT PACK LIGHT ILLUMINATES ON RECALL. LT ZONE CONT, LOGGED TCV FAULT. ACCOMP FIM 21-62 801, FAULT CLEARED & TESTS NORMAL.SDR ASAA2012122993560Control Valve · faultedLEFT PACK LIGHT ILLUNIMATED ON RECALL. EXTINGUISHED WITH RESET. ACCOMPLISHED PACK/ ZONE TEMP CONTROLLER BITE M1442, FIM 21-62, 801. MESSAGE FAULT TCV. R & R LEFT TEMP CONTROL VALVE IAW MM 21-51-10-400-801. OPS AND LEAK CHECKED GOOD.SDR ASAA2012122893576Warning Light · malfunctionedDURING NR 1 ENGINE START SEQUENCE, BLUE ENGINE VALVE CLOSED LIGHT REMAINED ILLUMINATED LONGER THAN NORMALLY OBSERVED. FUEL FLOW AND EGT RISE OCCURRED WITH LIGHT. LIGHT EXTINGUISHED. ALL INDICATIONS NORMAL. OP AND LEAK CHECKED NR 1 ENGINE HPSOV VALVE REF SDR ASAA2012122893574Ignition Unit · faultedDURING MX TROUBLESHOOTING, CSS FAILED, FAULT LIGHT. FOUND FAULT CODE 49-41011. NO FLAME SHUTDOWN. MADE 2 START ATTEMPTS WITH NO EGT RISE NOTED, FAULT LT ILLUM AND FAULT CODE 349-41011. LATCHED ON EACH ATTEMPT. ACCOMP. FIM TASK 49-40, TASK 802, FOR MAINT. SDR ASAA2012122893573Warning Light · false activationON TAXI OUT, FMC DISAGREE WAS ANNUNICATED ON THE NDS. QRH PROCEDURES WERE ACCOMPLISHED WITH NO FURTHER PROBLEMS NOTED. PERFORMED FIM 34-61, TASK 835 IAW INSTRUCTIONS FROM AMM 34-61-01-800-801. FMC DISAGREE ON GROUND IS A NUISANCE ANOMALY AND WAS CLEARED.SDR ASAA2012122893563Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON DEPARTURE. FOLLOWED QRH PROCEDURE, WOULD NOT RESET. PACK LIGHT WENT OUT AFTER APPROX 20 MIN. PERFORMED FIM TASK 21-62, TASK 801 ON LT PACK TEMP CONTROLLER. OPS CHECKED GOOD. LIGHT STAYS EXTINGUISHED AT THIS TIME. NO HISTORYSDR ASAA2012122793571Terminal · looseRIGHT SIDE WINDSHIELD WINDOW OVERHEAT LIGHT ON AT 2000FT 150 IAS, 2-5 TAT WHILE ON APPROACH. RT WHCU SHOWS SENSOR FAULT. FRONT TERMINAL LOOSE -SECURED LUG FOR A H-15 WINDOW BOTH PRIMARY & SECONDARY SENSORS 100 ARE OUT OF TOLERANCE, REF MM 30-41-21, WDM 30-41SDR ASAA2012122793569Eec · faultedA/T LIM SHOWING ABOVE N1 INDICATORS AFTER SPLIT THROTTLES AND AUTO THROTTLE DISCONNECT. A/T INFLT FAULTS SHOW MANY 22-31411 AND 22-31511 EEC 1A/1B DATA INV AND THROT SPLIT 22-31525. DEUS 1 & 2 FAULT 31-68210 NO EEC-1 CH A BUSS DATA. EEC 1 & 2 SHOW NO RECENTSDR ASAA2012122793568Control Valve · faultedRIGHT PACK LIGHT ILLUMINATED ON RECALL. PERFORMED RT TEMP CONTROLLER BITE ND FOUND THIS PACK TCV LOGGED. RESET FAULT, REF 21-61, TASK 801. GROUND RAN RT PACK REF 21-00-00 FOR HALF HOUR. PERFORMED RT PACK BITE AFTER GROUND OPS CHECK OF RT PACK. NO FAULTS LOSDR ASAA2012122793562Warning Light · false activationAFTER START, & CHECKLIST PERFORMED. MASTER CAUTION AIR CONDITIONING LIGHT ILLUMINATED. RESET WITH MASTER CAUTION. CHECKLIST ACCOMPLISHED. PRIMARY OR SECONDARY TEMP CONTROL INOPERATIVE. RT PACK ZONE TEMP CONTROL BITE LOGS THIS PACK - TCV IN MEMORY. RESET SDR ASAA2012122793561Controller · malfunctionedON RECALL, AFTER START LEFT PACK REMAINED ON. FOLLOWED QRH AND LIGHT WENT OUT WITH RESET. RESET BOTH TEMP CONTROLLERS IAW PLAC ON FRONT OF CONTROLLERS. 1 & 2 RESET OK.SDR ASAA2012122693559Fire Loop · inoperativeAFT CARGO FIRE TEST LOOP A INOPERATIVE. REPLACED A1 SMOKE DETECTOR. OPS CHECKED GOOD. REF AMM 26-26-02.SDR ASAA2012122693558Actuator · illuminatedWHILE PERFORMING T/C 78273000, HAD FAULT 75-10391. THE VSV POSITION SIGNAL IS OUT OF RANGE, LONG TERM FAULT, NR 1 ENGINE. REMOVED NR 1 ENG INBD (RT) VSV ACTUATOR IAW AMM 75-31-01-000-802-F00. INSTALLED HEAD-END NIPPLE, ROD-END NIPPLE AND DRAIN PORT NIPPLE FOSDR ASAA2012122693554Screw · wornNR 2 ENGINE, NR 5 FAN DUCT PANEL WITH LPTACC SCOOP HAS 2 LOOSE FASTENERS AND MISSING 2 WASHERS. ON FURTHER INSPECTION, NOTED THAT THERE WERE NO MISSING WASHERS, THE SCREW HEADS HAD WORN LEAVING A GAP BETWEEN THE PANEL AND SCREW HEAD. REPLACED ALL SCREWS ONSDR ASAA2012122693553Warning Light · false activationAFTER ENGINE START, NOTED FMS DISAGREE ERROR MESSAGE DISPLAYED. FOLLOWED ABNORMAL PROCEDURE. RESET SUCCESSFUL. BOTH FMC OPS CHECKED NORMAL.SDR ASAA2012122693552Warning Light · false activationFMC DISAGREE MESSAGE AFTER TAXI OUT. FOLLOWED QRH PROCEDURE, OPS NORMAL.SDR ASAA2012122693551Warning Light · false activationON TAXI OUT, RECEIVED AN FMC DISAGREE LIGHT. ACCOMPLISHED QRH PROCEDURE. NORMAL SYS REGAINED, NO FURTHER PROBLEMS.SDR ASAA2012122693550Control Unit · malfunctionedON CLIMBOUT PASSING 26000 FT, RT SIDE WINDOW OVERHEAT LIGHT CAME ON. FOLLOWED QRH, RETURNED TO NORMAL OPS. REMOVED & REINSTALLED R2 WINDOW. SEALS GOOD. HISTORY SHOWS SENSOR FAULT. SENSOR OHMS GOOD & TERMINALS ARE TIGHT, REF MM 30-41-21. REPLACED R2 WISDR ASAA2012122693549Warning Light · illuminatedAMBER LIGHT ILLUMINATED ON OVERHEAD PANEL AFTER ENGINE START AND ON ENGINE DRIVEN GENERATORS. SPCU INOPERATIVE FAULT. RESET AND TESTS NORMAL IAW FIM 24-34, TASK 802. VERIFIED FAULT, GROUND VERIFICATION SUCCESSFUL.SDR ASAA2012122693548Warning Light · false activationDURING FLIGHT, ON RECALL MASTER CAUTION AIR CONDITIONER & NR 1 PACK LIGHT ILLUMINATE. ALL EXTINGUISH ON RESET. ACCOMPLISHED FIM 21-53, TASK 809. VERIFIED NO DEBRIS AT HEAT EXCHANGERS. LEFT PACK OPS CHECKED NORMAL ON GROUND. ZONE TEMP CONTROLLERS BITE TEST SDR ASAA2012122693547Controller · malfunctionedLEFT PACK TRIPPED ON SHORT FINAL. FOUND PACK ZONE CONTROLLER FAULT LIGHT ON LT PACK ZONE TEMP CONTOLLER. RESET FAULT & ACCOMPLISHED BITE IAW MM 21-61-00. NO FAULTS NOTED & PACK LIGHTS EXTINGUISH ON RECALL. OK FOR SERVICE.SDR ASAA2012122593542Apu · unknownAPU DID NOT START, FAULT LIGHT ILLUMUNATED ON GROUND. PERFORMED FIM TASK 49-31-808 STEP F, FAULT CORRECTED. STARTED APU 4 TIMES, OPERATED NORMAL.SDR ASAA2012122593541Transceiver · unknownPWS FAIL AND WEATHER RADAR FAIL, FLAGS DISPLAYED ON DISPLAY. FAULT CODE 34401000. FOUND CIRCUIT BREAKER D13 OUT ON P6-1. VISUALLY INSPECTED ACCESSIBLE WIRING BEHIND P6-1. NO DEFECTS NOTED. RESET CIRCUIT BREAKER IAW MM 20-60-01-860-801. PRECAUTIONARY R & RSDR ASAA2012122593540Wire · inoperativeRIGHT SIDE OVERHEAT LIGHT ILLUMINATED ON SHORT FINAL, APPROX 1500 FT, AFTER LANDING ACCOMPLISHED QRH. LEFT SWITCH IN OFF POSITION. TURNED RT SIDE WINDOW HEAT ON. 10 MINUTES LATER OVERHEAT LIGHT CAME ON. PERFORMED MM 30-41-21 TO CHECK RESISTANCE OF RT SIDE SDR ASAA2012122593539Circuit Breaker · trippedP18-3 A-6, CIRCUIT BREAKER FOUND TRIPPED. RESET CIRCUIT BREAKER AT P18-3 A-6 IAW AMM 20-60-01 AND WDM 30-21-11. CIRCUIT BREAKER REMAINS SET. ACCOMPLISHED NR 1 ENGINE COWL ANTI-ICE OPS TEST IAW AMM 30-21-00. OPS CHECKED GOOD. OK FOR SERVICE. SYS GROUND FUSDR ASAA2012122593538Indication Sys · malfunctionedAT PUSHBACK, THE NR 2 FUEL SYS DECREASED UNILATERALLY BY 400 POUNDS. DRAINED AND SUMPED NR 2 MAIN TANK. TANK UNIT AND COMPENSATOR VALUES WITHIN LIMITS. BITE TEST PASSES. NO CURRENT FAULTS, REF AMM 28-41-00-730-801.SDR ASAA2012122593537Warning Light · false activationELECRICAL LIGHT DISPLAYED ON OVERHEAD PANEL. PERFORMED P5-13 BITE PROCEDURE IAW FIM 24-31, TASK 801 BATTERY CHARGER INOPERATIVE, ONE MX MESSAGE. CLEARED MESSAGE, ALL SYS CHECKED NORMAL. ACFT OK FOR SERVICE.SDR ASAA2012122493535Shutoff Valve · failedLEFT DUCT PRESSURE BELOW 18 PSI (AT 16PSI) WITH IDLE POWER DURING HIGH STAGE CROSSOVER CHK. ACFT GROUNDED. R & R NR 1 ENG PRSOV AND LEAK AND OPS CHECKED GOOD IAW MM 36-11-04 ACP ENG BLEED AIR CROSSOVER OPS TEST IAW MM 36-11-00 TEST GOOD.SDR ASAA2012122493529Warning Light · false activationAUX PITOT LIGHT ILLUMINATED ON PUSHBACK. PERFORMED FIM 30-31, TASK 801. OPS CK NORMAL COULD NOT DUPLICATE FAULT.SDR ASAA2012122493528Indicator · inoperativeCENTER FUEL QUANTITY INDICATOR GOES BLANK AND TOTAL QUANTITY INDICATOR GOES BLANK . HAPPENS RANDOMLY. IT OCCURRED 3 TIMES WHILE ON DESCENT. AFTER ABOUT 5 SECONDS THE INDICATORS RETURNED TO NORMAL. ACFT GROUNDED. PERFORMED FQIS BITE 28-41TASK 808. REQUIRESSDR ASAA2012122493524Warning Light · false activationON RECALL LEFT PACK LIGHT ILLUMINATED WHEN PUSH TO RESET IS PUSHED. THE PACK LIGHT EXTINGUISHES. ACCOMPLISHED PACK/ZONE TEMP COMP BITE IAW AMM REF 21-61-20 GROUND VERIFICATION SUCCESSFUL, OPS CHECKED NORMAL.SDR ASAA2012122493523Warning Light · false activationFMC DISAGREE MESSAGE DISPLAYED ON GROUND. PERFORMED QRH, OPS NORMAL.SDR ASAA2012122393536Apu · unknownFOLLOWING GROUND POWER INTERRUPTION APU INDICATES FAULT ON START. WILL NOT START. RESTARTED APU AFTER 5 MINUTES. APU STARTED NORMAL, NO FAULT LIGHT ILLUMINATED, NO HISTORY ON LAST 30 DAYS. OK FOR SERVICE.SDR ASAA2012122393533Regulator · failedON THE GROUND WITH BOTH ENGINES RUNNING AND BOTH PACKS IN AUTO, LT DUCT PRESSURE INDICATES 5 PSI AND WILL NOT INCREASE AS POWER IS ADVANCED. RT SIDE NORMAL 20 PSI AT IDLE AND INCREASING AS POWER ADVANCED. R & R NR 1 HIGH STAGE REGULATOR IAW AMM 36-11-07. GRSDR ASAA2012122393532Fmc · malfunctionedSINGLE FMC OPERATION ANNUNCIATED IN FLIGHT. SELECTED BOTH ON LEFT TO RESTORE COPILOTS DISPLAY. TESTED IAW FIM 34-61 TASK 807, NO FAULTS, INTERMITTENT, NO FURTHER ACTION REQUIRED.SDR ASAA2012122393531Battery Pack · failedEMERGENCY LIGHT POWER SUPPLY M1873 BATTERY PACK FAILS DEEP CYCLE CHECK. REF SSM 33-51-14 R & R AND TESTED BATTERY PACK FOR EMERGENCY LIGHT POWER SUPPLY M1873 IAW MM 33-51-06-960-805. OPS NORMAL.SDR ASAA2012122393530Circuit Breaker · trippedRT SIDE WINDOW HEAT OVERHEAT LIGHT ILLUMINATED WHEN SWITCH MOVED TO ON POSITION. FOUND RT SIDE WINDOW HEAT CIRCUIT BREAKER OUT ON P6-11. INSPECTED CIRCUIT REF WDM 30-41-11, FOUND NORMAL. RESET CIRCUIT BREAKER. GROUND VERIFICATION SUCCESSFUL. SYS TESTS OK, SDR ASAA2012122393527Compensator · malfunctionedNR 2 FUEL TANK QTY AND FUEL TOTALIZER WENT BLANK ON UPPER DU FOR APPROX 1 MINUTE THEN RETURNED TO NORMAL. REPLACED NR 2 TANK COMPENSATOR UNIT REF MM 28-41-21-400-801, STEPS 2.C.(1) THRU 3.E.(1), (2), (4)-(8). TANK COMPENSATOR UNIT. T/C 7852800 FUEL TANK ENTSDR ASAA2012122393526Indication Sys · malfunctionedDURING LEVEL FLIGHT BURNING OUT OF CENTER TANK , NOTICED RT FUEL QUANTITY DROP FROM 8.72 TO 8.30 QUANTITY STAYED AT 8.30 FOR ABOUT AN HOUR THEN JUMPED BACK TO 8.72 RT QUANTITY THEN SEEMED TO INDICATE CORRECTLY FOR REMAINDER OF FLIGHT. FOUND FQIS FAULT MESSAGESDR ASAA2012122293522Indication Sys · unknownDURING PREFLIGHT, TOTAL FUEL QTY WAS 43.1 ( LT QTY APPROX 8.52, CNT 26.01, RT APPROX 8.5 ). DURING PUSHBACK PRIOR TO CHECK, FUEL QTY WAS 42.7 W/TANKS READING L 8.52, CNTR 26.01, R 8.12. RT FUEL QTY INDICATED 400 LESS THAN PREVIOUSLY INDICATED. ACCOMPLISHED FSDR ASAA2012122293521Shutoff Valve · failedPNEUMATIC DUCT SPLIT DURING CLIMB AND CRUISE IN EXCESS OF 20 PSI. LEFT DUCT INDICATES 20 PSI, RIGHT IS 40-45 PSI. ACFT GROUNDED. RAN NR 1 ENG ON GROUND AND VERIFIED LOW LT DUCT PRESS WITH PACKS ON. R & R LT PRSOV IAW AMM 36-11-04 AND BAR IAW AMM 36-11-03. SDR ASAA2012122293518Processor · faultedNR 2 FUEL GAUGE FLASHING AT PANEL. ACFT GROUNDED. TRANSFERRED 100 LBS IAW FIM TASK 28-21-21-816, OPS CKS NORMAL. NO HISTORY 10 DAYS. REPLACED FUEL QTY PROCESSOR UNIT, REF MM 28-41-81. ALSO, REPLACED NR 2 REFUEL QTY IND, REF MM 28-41-61. OPS TEST OF FQIS NSDR ASAA2012122293519Lens · missingF/A REPORTS, ON TAKEOFF, METAL PLATE ON L1 DOOR WHICH COVERS EMERGENCY EXIT LIGHTING, FELL OFF & GLASS LENS BROKEN. NOTE PART ON FED PEDESTAL ON FLT DECK. R & R L1 ENTRY DOOR LIGHT ASSY IAW AMM 33-29-00.
Back to Boeing 737-890