Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023050846598Controller · missingOVERWING EXIT SIGN MISSING A COVER<[01] INSTALLED NEW COVER REF MM 33-51-03;[02] THIS WAS ENTERED ON WRONG A/C. DISCREPANCY WAS FOR A/C 8683. ITEM WAS CLOSED AND UNABLE TO CANCEL.SDR SWAA2023052545319Beam · crackedAFT CARGO COMPARTMENT BILGE AREA. SUPPORT ANGLE FOR WASTE TANK ENCLOSURE BEAM IS CRACKED. LOCATED AT STA 867 LBL 13; WL 161. MARKED. AFT CARGO COMPARTMENT BILGE AREA. SUPPORT ANGLE FOR WASTE TANK ENCLOSURE BEAM IS CRACKED. LOCATED AT STA 867 LBL 13 WL 161. MARSDR SWAA2023052545316Web · corrodedAFT CARGO DOOR CUTOUT SURROUND STRUCTURE. LOWER MAIN SILL WEB HAS MINOR SURFACE CORROSION AROUND FASTENER HOLES STARTING AT STA 787 TO STA 847 RBL 21 TO RBL 27. MARKED<[01] FAULT DUPLICATED IN ERROR. REFERENCE FAULT TTG8Q00KTSGQ FOR CORRECTIVE ACTION.;[02] C/ASDR SWAA2023052545310Angle · corrodedAFT CARGO LH FLOOR TRANSITION ANGLE (SIDEPLATE CHANNEL) HAS CORROSION IN NUMEROUS AREAS ON AND AROUND FASTEN HOLES STA-747 TO 787 (MARKED)<[01] BLENDED OUT CORROSION AT L/H TRANSITION ANGLE STA 747 TO 787; LBL 21 PER REF. SRM 51-10-02. REMAINING MATERIAL THICKSDR SWAA2023052545614Angle · corrodedAFT CARGO RH FLOOR TRANSITION ANGLE (SIDEPLATE CHANNEL) CORROSION OUT OF LIMITS BS727I TO 727J.<[01] COMPLIED WITH MEASUREMENTS.;[02] COMPLIED WITH TOOL REQUIREMENT.;[03] REMOVED CORROSION FROM AREA PER SRM 53-00-53-1A-2 (REMAINING THICKNESS 0.036'). TRANSITIOSDR SWAA2023052445612Flap · delaminatedLEFT WING OUTBOARD AFT FLAP HAS A LARGE AREA OF DELIMITATION ON THE INBOARD LOWER SURFACE. (PIC ATTACHED)<[01] REMOVED AND REPLACED OUTBOARD AFT FLAP IAW AMM 27-51-22. SEE STEPS 1-3 FOR INDIVIUAL SIGN OFFS.;[02] INSPECTED WORK PERFORMEDSDR SWAA2023050545507Brake · crackedFLOOR BOARD SUPPORT L/H PANEL BRAKE ASSY. CRACKED - LOCATED AT STA 540 (P/N 143A5240-35) (ZONE 125)<[01] REPLACED LH BRAKE ASSY REF SRM 51-40-02SDR SWAA2023050545508Brake · crackedFLOOR BOARD SUPPORT R/H PANEL BRAKE ASSY. CRACKED - LOCATED AT STA 540 (P/N 143A5240-36) (ZONE 126)<[01] REPLACED RH BRAKE ASSY REF SRM 51-40-02SDR SWAA2023050545941Seal · out of positionLEFT AFT HORIZONTAL SLIDING SEALS OUT OF TRACK<[01] REMOVED AND REINSTALLED LEFT AFT HORIZONTAL SLIDING SEAL PER AMM 53-31-31. RAN STABILIZER OPS CHECK NORMALSDR SWAA2023052545067Angle · crackedFWD CARGO R/H SIDEPLATE HAS POSSIBLE CRACK AT I/B ATTACH FASTENER RBL 21; STA. 500B.<[01] CRACKED FOUND OUT OF LIMIT .I.A.W. SRM 53-00-53-1A-2.;[02] REMOVED RH TRANSITION ANGLE STA 500B-500I PER SRM 51-40-02;[03] LOCATE AND DRILL REPAIR PARTS FROM STA 500B TO SDR SWAA2023052545083Plate · crackedFWD CARGO L/H SIDEPLATE HAS POSSIBLE CRACK AT I/B ATTACH FASTENER LBL 21; STA. 500B.<[01] FWD CARGO L/H SIDE PLATE FROM STA 440+10 TO STA 500I REPLACED ON FAULT TTG8Q00KSRV.;[02] CORRECTIVE ACTION #1 ENTERED INCORRECTLY. FWD CARGO L/H SIDE PLATE FROM STA 440+1SDR SWAA2023052545073Structure · corrodedSURFACE CORROSION ON UPPER FLOOR STRUCTURE AROUND O/B AFT LAV MOUNT FOR AFT L/H LAV. (MKD)<[01] DRAIN INTERCOSTAL OUT OF LIMITS PER SRM 53-70-51-1A-1;[02] LOCATED AND DRILLED REPLACEMENT INTERCOSTAL; COUNTERSUNK FASTENER HOLES AS REQUIRED PER REF. SRM 51-40-05SDR SWAA2023052545059Angle · corrodedFWD CARGO AFT BULKHEAD PANEL LOWER ATTACH ANGLE HAS CORROSION AT FASTENER HOLES; RBL 11-RBL 24; STA. 500I<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE TO BE .009? IN DEPTH. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-30-08-1A-1.;[02] REMOVED DAMAGSDR SWAA2023052545075Plate · corrodedFWD CARGO R/H SIDEPLATE HAS CORROSION AT FASTENER HOLES RBL 24; STA. 500D-500E<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .010? IN DEPTH. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.;[02] REMOVED RH TRANSITION ANGLE STA 50SDR SWAA2023052545076Plate · corrodedFWD CARGO R/H SIDEPLATE HAS CORROSION AT FASTENER HOLES RBL 24; STA. 500E-500F<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .015?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.;[02] REMOVED RH TRANSITION ANGLE STA 500B-500H PSDR SWAA2023052545061Plate · corrodedFWD CARGO R/H SIDEPLATE HAS CORROSION AT FASTENER HOLES RBL 24; STA. 500F-500G<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .009?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.;[02] REMOVED RH TRANSITION ANGLE STA 500B-500H PSDR SWAA2023052545064Threshold · corrodedAFT CARGO DOOR THRESHOLD CORROSION AT STA 795 TO 847; RBL 27. AFT CARGO DOOR THRESHOLD CORROSION AT STA 795 TO 847 RBL 27.<[01] BLENDED OUT CORROSION AT AFT CARGO DOOR THRESHOLD WEB PER SRM 51-10-02. REMAINING MATERIAL THICKNESS OUT OF LIMITS PER SRM 53-60-15-SDR SWAA2023052545077Plate · corrodedFWD CARGO R/H SIDEPLATE HAS CORROSION AT FASTENER HOLES RBL 24; STA. 500H-500I<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .006?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.;[02] REMOVED RH TRANSITION ANGLE STA 500B-500I PSDR SWAA2023052545062Plate · corrodedFWD CARGO R/H SIDEPLATE HAS CORROSION AT FASTENER HOLES RBL 24; STA. 500G-500H<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .009?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.;[02] REMOVED RH TRANSITION ANGLE STA 500B-500H PSDR SWAA2023052545086Threshold · corrodedFWD CARGO DOOR THRESHOLD WEB HAS CORROSION RBL 28; STA. 440-492.<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .006?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-30-15-1A-1.;[02] LOCATED AND DRILLED NEW WEB PER SRM 51-40-02;[03] LOCATEDSDR SWAA2023052545298Beam · corrodedCORROSION ON FLOOR BEAM AT STA 927+10; LBL +52- MARKED. FAULT #1137 CLOSED IN ERROR<[01] DRAIN INTERCOSTAL OUT OF LIMITS PER SRM 53-70-51-1A-1;[02] FAULT TO BE RESOLVED ON ANOTHER FAULT. REF TTG8Q00KTSPA;[03] INSPECTED WORK PERFORMEDSDR SWAA2023052545078Plate · corrodedFWD CARGO L/H SIDEPLATE HAS CORROSION AT FASTENER HOLES LBL 24; STA. 500D-500E<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .018?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.[08] INSPECTED WORK PERFORMED ON C/A #7;[09] ENGISDR SWAA2023052545299Intercostal · crackedLEFT INBOARD FAN COWL HAS CRACKED INTERCOSTAL ON OIL ACCESS DOOR FRAME.<[01] REMOVED AND REPLACED INTERCOSTAL PER ARM. 51-40-02;[02] INSPECTED WORK PERFORMED.SDR SWAA2023052545300Web · crackedRIGHT OUTBOARD FAN COWL HAS CRACKED INTERCOSTAL ON OIL SERVICE DOOR FRAME.<[01] REMOVED AND REPLACED WEB I.A.W SRM 51-40-02.;[02] INSPECTED WORK PERFORMEDSDR SWAA2023052446186Panel · missingPANEL 221BF HAS FIBERS MISSING<[01] INSTALLED NEW 221BF PANEL PER AMM 53-21-00-401-NG (PASSENGER CABIN FLOORS - REMOVAL/INSTALLATION - PERMANENT);[02] C/W INSPECTION.SDR SWAA2023052446185Panel · missing-PANEL 221DF HAS FIBERS MISSING<[01] INSTALLED NEW 221DF PANEL PER AMM 53-21-00-401-NG (PASSENGER CABIN FLOORS - REMOVAL/INSTALLATION - PERMANENT);[02] C/W INSPECTION.SDR SWAA2023052446176Panel · missingPANEL 221FF HAS FIBERS MISSING<[01] INSTALLED NEW 221FF PANEL PER AMM 53-21-00-401-NG (PASSENGER CABIN FLOORS - REMOVAL/INSTALLATION - PERMANENT);[02] C/W INSPECTION.SDR SWAA2023052446184Panel · missingPANEL 221GF HAS FIBERS MISSING<[01] INSTALLED NEW 221GF PANEL PER AMM 53-21-00-401-NG (PASSENGER CABIN FLOORS - REMOVAL/INSTALLATION - PERMANENT);[02] C/W INSPECTION.SDR SWAA2023052446175Floor Panel · missingPANEL 242PF HAS FIBERS MISSING<[01] REMOVED AND REPLACED FLOOR PANEL 242PF IN REFERENCE TO AMM 53-21-00. PART ORDERED UNDER TASK [TTG8Q008LYZ6];[02] C/W INSPECTIONSDR SWAA2023052446183Floor Panel · missing-PANEL 242QF HAS FIBERS MISSING<[01] REMOVED AND REPLACED FLOOR PANEL 242QF IN REFERENCE TO AMM 53-21-00. PART ORDERED UNDER TASK [TTG8Q008LYZ6];[02] C/W INSPECTIONSDR SWAA2023052446182Floor Panel · missingPANEL 241D HAS FIBERS MISSING<[01] REMOVE AND REPLACED FLOOR PANEL 241D PER AMM 53-21-00. PART ORDERED UNDER TASK (TTG8Q008LYZ6).;[02] C/W INSPECTIONSDR SWAA2023052446181Floor Panel · missingPANEL 241UF HAS FIBERS MISSING<[01] REMOVED AND REPLACED FLOOR PANEL 241UF IN REFERENCE TO AMM 53-21-00. PART ORDERED UNDER TASK [TTG8Q008LYZ6];[02] C/W INSPECTIONSDR SWAA2023052446180Floor Panel · missing-PANEL 241VF HAS FIBERS MISSING<[01] REMOVED AND REPLACED FLOOR PANEL 242VF IN REFERENCE TO AMM 53-21-00. PART ORDERED UNDER TASK [TTG8Q008LYZ6];[02] REMOVED AND REPLACED FLOOR PANEL 241VF IN REFERENCE TO AMM 53-21-00. PART ORDERED UNDER TASK [TTG8Q008LYZ6];[0SDR SWAA2023052446179Panel · missing-PANEL 241WF HAS FIBERS MISSING<[01] REMOVED AND REPLACED FLOOR PANEL 241WF IN REFERENCE TO AMM 53-21-00. PART ORDERED UNDER TASK [TTG8Q008LYZ6];[02] C/W INSPECTIONSDR SWAA2023052446178Panel · missingPANEL 241XF HAS FIBBERS MISSING<[01] REMOVE AND REPLACED FLOOR PANEL 241XF PER AMM 53-21-00. PART ORDERED UNDER TASK (TTG8Q008LYZ6).;[02] C/W INSPECTIONSDR SWAA2023052446177Floor Panel · missing-PANEL 242D HAS FIBERS MISSING<[01] REMOVE AND REPLACED FLOOR PANEL 242D PER AMM 53-21-00. PART ORDERED UNDER TASK (TTG8Q008LYZ6).;[02] C/W INSPECTIONSDR SWAA2023052445065Plate · crackedFWD CARGO L/H SIDEPLATE HAS PUNCTURE WITH CRACK AT LBL 24; STA. 500C +13'<[01] PUNCTURE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.;[02] CUT AND REMOVED THE DAMAGED TRANSITION ANGLE FRO STA 450 TO STA 500I L/H PER SRM 53-00-53-2R-5.;[03] LOCATED AND DRISDR SWAA2023052445004Seat Track · corrodedCORROSION AT SEAT TRACK #4 RBL 45.50 STA 867+12.<[01] REMOVED CORROSION 0.050' PER SRM 51-10-02. OUT OF LIMITS PER SRM 53-00-52-1A-1.FABRICATED AND LOCATED HOLES IN -2 ANGLES; -4 STRAPS; -5 STRAPS AND -3 STRAP PER SRM 53-00-52-2R-5 APPLIED PROTECTIVE COATING PSDR SWAA2023052445005Seat Track · corrodedCORROSION AT SEAT TRACK #4 RBL 45.50 STA 847 TO 867.<[01] SEAT TRACK BEING REPAIRED FROM CUT AND REMOVED SEAT TRACK #4; RBL 45.50 FROM STA. 827+9.500 TO STA. 887. SEE TTG8Q00KTREZ FOR REPAIR.;[02] SEAT TRACK BEING REPAIRED FROM CUT AND REMOVED SEAT TRACK #4; RSDR SWAA2023052444646Web · cracked#1 ENGINE IB FAN COWL INTERIOR WEB CRACKED AT ENGINE OIL SERVICE DOOR (MARKED)<[01] REMOVED AND REPLACED WEB PER SRM 51-40-02;[02] C/W INSP .REMOVED AND REPLACED WEB PER SRM 51-40-02SDR SWAA2023052344592Floor Panel · pulledPASSENGER CABIN FLOORBOARD 241DF HAS SEVERAL FIBER STRANDS MISSING ON TOP LAYER OF PANEL<[01] REPLACED WITH NEW FROM STOCK PANEL PER AMM 53-21-00. TO BE INSTALLED ON CARD TTG8Q00K37DY;[02] INSPECTION C/WSDR SWAA2023052344594Floor Panel · pulledPASSENGER CABIN FLOORBOARD 241AF HAS SEVERAL FIBER STRANDS MISSING ON TOP LAYER OF PANEL<[01] REPLACED WITH NEW FROM STOCK PANEL PER AMM 53-21-00. TO BE INSTALLED ON CARD TTG8Q00K37E4.;[02] INSPECTION C/WSDR SWAA2023052344598Floor Panel · pulledPASSENGER CABIN FLOORBOARD 231XF HAS SEVERAL FIBER STRANDS MISSING ON TOP LAYER OF PANEL<[01] REPLACED WITH NEW FROM STOCK PANEL PER AMM 53-21-00. TO BE INSTALLED ON CARD TTG8Q00K37EG.;[02] INSPECTION C/WSDR SWAA2023050845322Handle · loosePER CUSTOMER REQUEST- L2 DOOR ASSIST HANDLE LOOSE<[01] RESECURED L2 DOOR ASSIST HANDLE AS PER AMM 52-13-31-400-802;[02] VERIFIED AND INSPECTED STEP #1; RESECURED L2 DOOR ASSIST HANDLE AS PER AMM 52-13-31-400-802SDR SWAA2023050545557Bracket · looseFORWARD GALLEY SERVICE DOOR GIRT BAR BRACKET IS LOOSE ? NOT SECURE<[01] REPLACED GIRT BAR BRACKET RIVET PER SRM 51-40-02SDR SWAA2023050544462Seal · crackedR/H HORIZONTAL FWD UPPER SLIDING SEAL CRACKED<[01] REMOVED AND REPLACED UPPER SLIDING SEAL IAW AMM 53-31-31.SDR SWAA2023050445558Cover · out of adjustMAIN ENTRY DOOR EMERGENCY LIGHT COVER FELL OFF.<[01] RESECURED EMERGENCY EXIT LIGHT COVER PER SIPSDR SWAA2023052544290Seal · crackedR/H FORWARD UPPER HORIZONTAL STABILIZER SLIDING SEAL CRACKED FOR AND AFT.<[01] DUPLICATE WRITE UP; SEE FAULT # TTG8Q00KT349 (LINE #1110) FOR CORRECTIVE ACTION;[02] VERIFIED<BR>DUPLICATE WRITE UP; SEE FAULT # TTG8Q00KT349 (LINE #1110) FOR CORRECTIVE ACTIONSDR SWAA2023052444508Scuff Plate · crackedFORWARD CARGO FORWARD CORNER SCUFF PLATE CRACKED.<[01] FORWARD CARGO FORWARD CORNER REPAIRED BY OUTSIDE VENDOR (REF # P7027523) & WILL BE INSTALLED ON MT# 753-140-00-01Y [TTG8R008185Q] AS PER AMM 53-11-02.;[02] INSPECTED WORK PERFORMEDSDR SWAA2023052444509Scuff Plate · crackedFORWARD CARGO AFT CORNER SCUFF PLATE CRACKED.<[01] FORWARD CARGO AFT CORNER REPAIRED BY OUTSIDE VENDOR (REF # P7027524) & WILL BE INSTALLED ON MT# 753-140-00-01Y [TTG8R008185Q] AS PER AMM 53-11-02.;[02] INSPECTED WORK PERFORMED
Back to Boeing 737-8H4