SDR SWAA2022101128532Shield · corrodedAFT CARGO BAY SHIELD FWD OF CARGO DOOR HAS AREAS OF CORROSION BS767 TO BS794 RBL22 WL156 / [01] EVALUATED CORROSION ON SHIELD BS 767 TO 794 RBL 22 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02]SDR SWAA2022101128530Angle · corrodedAFT CARGO LOWER ATTACH ANGLE COMMON TO SHIELD HAS AREAS OF CORROSION BS767 TO BS787 RBL21 WL156 / [01] EVALUATED CORROSION ON ATTACH ANGLE BS 767 TO 787 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10SDR SWAA2022101128534Plate · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS MULTIPLE AREAS OF CORROSION BS727H TO BS767 RBL22 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS OF FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 747+10 RBL 22 WL 156; FOUND 0.015 REMOVEDSDR SWAA2022101028531Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL SPLICE HAS CORROSION BS767+6 RBL8 WL156 / [01] EVALUATED CORROSION ON FLOOR PANEL SPLICE BS 767+6 RBL 8 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED MEASURESDR SWAA2022092927876Battery Pack · inoperativeDURING EMERGENCY LIGHTS CHECK; FOUND SEVERAL EMERGENCY LIGHTS INOP. / [01] INSTALLED NEW BATTERY PACKS AT POSITIONS M1670; M1671; M1672; M1673 AS PER B737 AMM REF 33-51-06-960-805. TESTED FOUND NORMAL.;[02] INSTALLED NEW BATTERY PACK AT POSITION M02816 AS PER SDR SWAA2022092922760Battery Pack · inoperativeAFT GALLEY EMERGENCY LIGHTS INOP / [01] REMOVED AND REPLACED 2 AFT EMER BATTERY PACKS LEFT AND RIGHT IAW AMM 33-51-06;[02] VERIFIED THE REMOVAL AND REPLACEMENT OF AFT EMER BATTERY PACKS LEFT AND RIGHT AND OPS CHECK GOOD IAW AMM 33-51-06.SDR SWAA2022092724647Megaphone · inoperativeFWD MEGAPHONE INOP RECORDED BY CREW / [01] REMOVE AND REPLACED FWD MEGAPHONE IAW AMM 25-64-00SDR SWAA2022092724641None · missingMID- CABIN AFT FACING EXIT SIGN MISSING / [01] INSTALLED SIGN/LENS REF AMM 33-51-01SDR SWAA2022092724637None · out of adjustOVERWING WINDOW EXIT SIGN NEEDS TO BE REATTACHED. / [01] RESECURED MID CABIN EXIT SIGN PER AMM 33-51-00.SDR SWAA2022092716222Doubler · crackedEXTERNAL GROUND POWER RECEPTACLE SURROUND DOUBLER TAB HAS A CRACK WITH MISSING MATERIAL AT LOWER LOBE ACROSS TWO FASTENERS IN ZONE 2. BETWEEN STA 224.8 AND 235.8 6.5' ABOVE 23R / [01] INSTALLED PERMANENT REPAIR PER SRM 53-10-15-2R-4-B00449 (REPAIR 4 )SDR SWAA2022092716304Bracket · crackedLEFT WING FIXED TRAILING EDGE PANEL SUPPORT BRACKET O/B CLIP CRACKED. / [01] REMOVED AND INSTALLED LEFT WING FIXED TRAILING EDGE PANEL SUPPORT BRACKET O/B CLIP. REF SRM 51-40-02SDR SWAA2022101016013Shield · corrodedAFT CARGO RH FLOOR SUPPORT ANGLE CORRODED BELOW TRANSITION SHIELD AT STA. 767 TO 787. / [01] REMOVED CORROSION TRANSITION SHIELD AT STA. 767 TO 787PER SRM.51-10-02 ; MATERIAL FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-2 ;REMOVED AND REPLACED TRANSITION SHIELD ATSDR SWAA2022092616160Stiffener · crackedLH WING INBD FIXED LEADING EDGE STIFFENER COMMON TO DENT HAS A .375 L CRACK AT OB END. HFEC VERIFIED. / [01] R/R?D STIFFENER PER SRM 51-40-02;[02] MEASUREMENTS ADDED;[03] CW;[04] CWSDR SWAA2022101016011Floor Panel · poppedCABIN FLOOR PANEL 231DF HAS POPPING NOISE WHEN WALKED ON / [01] REMOVED AND INSTALLED NEW CABIN FLOORBOARD PER AMM 53-21-00;[02] COMPLIED WITH INSPECTION OF REMOVED AND INSTALLED NEW CABIN FLOORBOARD 231DF PER AMM 53-21-00SDR SWAA2022100594965Threshold · crackedAFT CARGO BAY AFT CORNER THRESHOLD IS CRACKED / [01] WELDED CRACK ON AFT CARGO BAY AFT CORNER SCUFF PLATE USING ER4043 FILLER ROD LOT NUMBER 1131216 PER 737-800 SRM 53-60-15-2R-1 PARA 4.B.(2) AND (4)<BR>EQUIPMENT USED: WELDING MACHINE; E10583; CAL DUE 12/22;[0SDR SWAA2022092694508None · crackedLEFT WING AFT FIXED TRAILING EDGE PANEL SUPPORT BRACKET OUTBD CLIP IS CRACKED. / [01] REMOVED AND INSTALLED LEFT WING AFT FIXED TRAILING EDGE PANEL SUPPORT BRACKET OUTBD CLIP. REF SRM 51-40-02.SDR SWAA2022100694997None · cutLEFT HORIZONTAL UPPER FORWARD SLIDER SEAL IS CUT; SHEARED AT FORWARD TRACK. / [01] INSTALLED ATTACH BRACKET WITH FASTENERS PER SRM 51-40-02.;[02] 1. DANIEL ANDERSON (TECHNICIAN); 21-SEP-2022 08:02 UTC<BR>INSTALLED ATTACH BRACKET WITH FASTENERS PER SRM 51-40-02SDR SWAA2022100616082None · cutRIGHT HORIZONTAL UPPER FORWARD SLIDER SEAL IS CUT; SHEARED IN FORWARD TRACK. / [01] REMOVED AND REPLACED R/H UPPER FWD SLIDING SEAL PER AMM 53-31-31;[02] RII: INSPECTED THE WORK PERFORMED ON C/A #1; THE REMOVAL AND REPLACEMENT OF THE R/H UPPER FWD SLIDING SEALSDR SWAA2022100694996None · delaminatedL/H HORIZONAL STAB TIP FAIRING HAS DELAMINATION ON UPPER SURFACE. / [01] REPLACED HORZ L/E TIP REF MM 27-41-21;[02] VERIFIED REPLACED HORZ L/E TIP REF MM 27-41-21;[03] CWSDR SWAA2022092693810Light · inoperativeAFT ENTRY DOOR EMERGENCY SLIDE LIGHT IS INOP / [01] REPLACED LAMP FOR AFT ENTRY DOOR SLIDE LIGHT AND PERFORMED GOOD TEST PER AMM 33-51-04-960-901.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2022101082957Intercostal · corrodedAFT CARGO R/H INTERCOSTAL STA. 747- 767 HAS LIGHT SURFACE CORROSION AROUND NUTPLATES / [01] REMOVED SURFACE CORROSION ON AFT CARGO R/H INTERCOSTAL ATTACH; FOUND TO BE OUT OF LIMITED. MATERIAL REMOVED .005 AND REMAINING THICKNESS .025. REFERENCE SRM 53-00-04-1ASDR SWAA2022092683131Battery Pack · failedEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1671 FAIL TO ILLUMINATE / [01] REMOVED AND REPLACED M1671 BATTERY PACK AND POWER SUPPLY CHARGER ASSY AND OPS CHECKED PER AMM 33-51-06 CHECKED GOOD;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2022092630514None · failedEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1671 FAIL TO ILLUMINATE / [01] REMOVED AND REPLACED M1671 BATTERY PACK AND POWER SUPPLY CHARGER ASSY AND OPS CHECKED PER AMM 33-51-06 CHECKED GOOD;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2022092283068None · inoperativeAISLE CEILING-EMERGENCY LIGHT LENS COVER MISSING ROW 17. / [01] REPLACED AISLE CEILING LENS AT ROW 17 EMERGENCY. IAW AMM 33-51-00. OP?S CHECKED GOOD.SDR SWAA2022092283101None · damagedFORWARD F.O. SIDE PHOTOLMINESCENT AISLE STRIP DIM / [01] CLEANED IAW M/M 33-51-15SDR SWAA2022092283120None · damagedLOWER EXIT LOCATOR SIGN FOR FWD ENTRY DOOR IS DAMAGED. REPLACED LOWER EXIT LOCATOR SIGN FOR FWD ENTRY DOOR AND PERFORMED GOOD TEST PER AMM 33-51-01-960-802.SDR SWAA2022092982772Floor Panel · damagedAFT CARGO PANEL 140AF IS FOUND TO BE OUT OF LIMITS REQUIRES REPLACEMENT / [01] FABRICATED NEW FLOOR PANEL PER AMM. 25-52-01-201-801;[02] 1. DAVID YECK (TECHNICIAN); 20-SEP-2022 09:25 UTC<BR>FABRICATED NEW FLOOR PANEL PER AMM. 25-52-01-201-801SDR SWAA2022092982771Floor Panel · damagedAFT CARGO FLOOR PANEL 140DF FOUND OUT OF LIMITS REQUIRES REPLACEMENT / [01] REMOVED AND REPLACED AFT CARGO COMPARTMENT FLOOR PANEL 140DF TO BE INSTALLED ON CLOSE CARD LINE 987 TTG8Q00385F PER AMM 25-52-10.SDR SWAA2022092283060Battery · inoperativeTWO FWD JUMPSEAT EMERGENCY FLASHLIGHTS WILL NOT CHARGE / [01] R&R'D BOTH FWD GALLEY EMERG FLASHLIGHT BATTERIES PER 25-64-00SDR SWAA2022092205546None · inoperativeBOTH AFT LEFT EMERGENCY FLASHLIGHTS DONT TEST / [01] R AND R FLASHLIGHTS PER AMM 25-64-00.SDR SWAA2022092283063None · inoperativeBOTH AFT LEFT EMERGENCY FLASHLIGHTS DONT TEST / [01] R AND R FLASHLIGHTS PER AMM 25-64-00.SDR SWAA2022092282626Light · inoperativeRH FWD ASILE ABOVE OVERHEAD BIN EMERGENCY LIGHTS INOP BETWEEN ROWS 2-16 RIGHT SIDE. R&R AISLE LIGHT POWERT SUPPLY BATT PACK REF AMM 33-51-06 OPS CHECK GOOD AT THIS TIME.SDR SWAA2022092282888None · inoperativeLIGHTS ASSOCIATED WITH BATTERY PACK M1675 ARE INOP / [01] RPLACED BATTERY PACK M1675 AND PERFORMED GOOD TEST PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2022092282889None · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1676 ARE INOP / [01] REPLACED BATTERY PACK M1676 AND PERFORMED GOOD TEST PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2022092282890None · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1694 ARE INOP / [01] REPLACED BATTERY PACK M1694 AMD PERFORMED GOOD TEST PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2022092282891None · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M2335 ARE INOP / [01] REPLACED BATTERY PACK M2335 AND PERFORMED GOOD TEST PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2022101182728None · looseLEFT AFT EMERGENCY EXIT DOOR; ESCAPE ROPE RETENTION STRAP VELCRO NOT SECURED TO FUSELAGE. / [01] REPLACED MISSING VELCRO I/A/W AMM 20-10-60.;[02] INCORRECT REFERENCE USED. REPLACED MISSING VELCRO I/A/W AMM 20-10-06.;[03] CERTIFYSDR SWAA2022101182729Rope · out of positionLEFT AFT EMERGENCY EXIT DOOR; ESCAPE ROPE NOT STOWED. / [01] STOWED ESCAPE ROPE I/A/W AMM 25-61-10.SDR SWAA2022101182744None · looseRIGHT AFT EMERGENCY EXIT DOOR; ESCAPE ROPE RETENTION STRAP VELCRO NOT SECURED TO FUSELAGE. / [01] REPLACED MISSING VELCO I/A/W AMM 20-10-06.;[02] INSPECTED AS REQUIRED.SDR SWAA2022101078794None · corrodedLH TRANS. ANGLE; HAS CORROSION STA. 500I-500H / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV0RQ DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF SIDEPLATE.;[02] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTGSDR SWAA2022101082724None · corrodedAFT CARGO R/H TRANSITION ANGLE STA. 767- 787 HAS LIGHT SURFACE CORROSION AROUND SCREW HOLES. / [01] REMOVED CORROSION AROUND NUT PLATES HOLES PER SRM. 51-10-02 MATERIAL REMOVED 0.006 FOUND OUT OF LIMITS PER SRM.53-00-53-1A;[02] REMOVED CORROSION RH FLOOR SUPPOSDR SWAA2022101082737None · corrodedAFT CARGO R/H TRANSITION ANGLE STA. 727I- 747 HAS LIGHT SURFACE CORROSION AROUND SCREW HOLES. / [01] REMOVED LIGHT SURFACE CORROSION ON FASTENER HOLES AT TRANS ANGLE ATTACH FOUND TO BE BEYOND ACCEPTABLE LIMITS. MATERIAL REMOVED .006 AND REMAINING THICKNESS .03SDR SWAA2022100539489Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M1672 INOP. / [01] REMOVED BATTERY PACK M1672 IAW AMM 33-51-06-960-805.;[02] INSTALLED THE BATTERY PACK M1672 IAW AMM 33-51-06-960-805.;[03] VERIFIED CORRECTIVE ACTION ITEM 2.;[04] COMPLETED STEP1.;[05] ***EDIT STEP 1 STATUS TO PARSDR SWAA2022100578738Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M1672 INOP. / [01] REMOVED BATTERY PACK M1672 IAW AMM 33-51-06-960-805.;[02] INSTALLED THE BATTERY PACK M1672 IAW AMM 33-51-06-960-805.;[03] VERIFIED CORRECTIVE ACTION ITEM 2.SDR SWAA2022092682638None · crackedP-3 CONNECTOR I/B OF L/H WINGLET HAS CRACKED BACK SHELL / [01] REMOVED AND REPLACED LEFT WINGLET CONNECTOR P3 BACKSHELL PER SWPM 20-25-12 AND CMM 57-31-00. FUNCTIONAL TEST TO BE PERFORMED ON CCN TTG8R008D23C;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2022092082453None · inoperativeFWD SERVICE DOOR HAS TWO EGRESS LAMPS INOP. / [01] RELAMPED FWD SERVICE DOOR LIGHTS; SATISFACTORY OP CK REF AMM 33-51-01.SDR SWAA2022092082859Slide · out of positionWHILE OPENING THE FRONT ENTRY DOOR THE SLIDE DROPPED OUT OF THE CONTAINER / [01] R&R'D FDW ENTRY DOOR EMERGENCY SLIDE PER MT#725-61-06-FESDR SWAA2022101278775None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500D-500C / [01] REMOVED CORROSION PER SRM 51-10-02. REMOVED .011 INCH OF MATERIAL. REMAINING THICKNESS IS .029 INCH AND IS OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE REQUIRES REPLACEMENT.SDR SWAA2022101139724None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500D-500C / [01] REMOVED CORROSION PER SRM 51-10-02. REMOVED .011 INCH OF MATERIAL. REMAINING THICKNESS IS .029 INCH AND IS OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE REQUIRES REPLACEMENT.;[02] SIDEPLATE WAS REMOVESDR SWAA2022101078774None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500E-500D / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV0RQ DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF SIDEPLATE.;[02] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8
Back to Boeing 737-8H4