Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022101078777None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500B-500A / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV0RQ DUE TO OUT OF LIMITS DAMAGE. MATERIAL REMAINING THICKNESS .029 AND MATERIAL THICKNESS REMOVED .011 IS FOUND TO BE OUT OF LIMITED PER SRM SRSDR SWAA2022101078778None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500A-500 / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV0RQ DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF SIDEPLATE.;[02] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8QSDR SWAA2022101078785None · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION; STA.500I-500H / [01] REMOVED CORROSION PER SRM 51-10-02. REMOVED .013 INCH OF MATERIAL. REMAINING THICKNESS IS .027 INCH AND IS OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE REQUIRES REPLACEMENT.;[02] LOCATED ASDR SWAA2022101078776None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500C-500B / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV0RQ DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF SIDEPLATE.;[02] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8SDR SWAA2022101078786Angle · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION;500H-500G / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV1E2 DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF ANGLE. REFERENCE NON-ROUTINE CARDS TTG8Q00EVOQN AND TTG8Q00EV1EY.;[02]SDR SWAA2022101078787Angle · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION;500G-500F / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV1E2 DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF ANGLE. REFERENCE NON-ROUTINE CARDS TTG8Q00EVOQN AND TTG8Q00EV1EY.;[02]SDR SWAA2022101078788None · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION;500E-500D / [01] REMOVED CORROSION PER SRM 51-10-02. REMOVED .020 INCH OF MATERIAL. REMAINING THICKNESS IS .020 INCH AND IS OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTSDR SWAA2022101078769None · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION;500D-500C / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV1E2 DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF ANGLE. REFERENCE NON-ROUTINE CARDS TTG8Q00EVOQN AND TTG8Q00EV1EY.;[02]SDR SWAA2022101078789None · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION;500B-500A / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV1E2 DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF ANGLE. REFERENCE NON-ROUTINE CARDS TTG8Q00EVOQN AND TTG8Q00EV1EY.;[02]SDR SWAA2022101078770None · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION;STA.500-492.4 / [01] REMOVED CORROSION PER SRM 51-10-02. REMOVED .006 INCH OF MATERIAL AT STATION 500 + 6. REMAINING THICKNESS IS .032 INCH AND IS OUT OF LIMITS PER SRM 53-00-53-1A-2. PART REQUIRES REPLACEMENT.;[02] LOCSDR SWAA2022101078768None · corrodedFWD CARGO; RH TRANS. ANGLE HAS CORROSION;500F-500E / [01] REMOVED CORROSION PER SRM 51-10-02. REMOVED .012 INCH OF MATERIAL. REMAINING THICKNESS IS .028 INCH AND IS OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTSDR SWAA2022101078772None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500H-500G / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV0RQ DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF SIDEPLATE.SDR SWAA2022101078773None · corrodedLH TRANS. ANGLE; HAS CORROSION STA.500G-500F / [01] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8Q00EV0RQ DUE TO OUT OF LIMITS DAMAGE AT OTHER LOCATIONS ALONG LENGTH OF SIDEPLATE.;[02] TRANSITION ANGLE ASSEMBLY TO BE REPLACED ON NON-ROUTINE TTG8SDR SWAA2022100572742Floor Panel · delaminatedCABIN FLOOR PANEL 242DF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572751Floor Panel · delaminatedCABIN FLOOR PANEL 242CF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572752Floor Panel · delaminatedCABIN FLOOR PANEL 242BF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.SDR SWAA2022100572753Floor Panel · delaminatedCABIN FLOOR PANEL 241FF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572754Floor Panel · delaminatedCABIN FLOOR PANEL 241DF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572755Floor Panel · delaminatedCABIN FLOOR PANEL 241CF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572756Floor Panel · delaminatedCABIN FLOOR PANEL 241BF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572757Floor Panel · delaminatedCABIN FLOOR PANEL 241AF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572743Floor Panel · delaminatedCABIN FLOOR PANEL 232SF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572758Floor Panel · delaminatedCABIN FLOOR PANEL 232RF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572744Floor Panel · delaminatedCABIN FLOOR PANEL 231ZF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022100572745Floor Panel · delaminatedCABIN FLOOR PANEL 231YF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.SDR SWAA2022100572747Floor Panel · delaminatedCABIN FLOOR PANEL 231XF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFO;[03] PARTS INFOSDR SWAA2022100572749Floor Panel · delaminatedCABIN FLOOR PANEL 242AF HAS DENTS AND DELAMINATION. / [01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[02] PARTS INFOSDR SWAA2022092074512None · out of positionEMERGENCY LIGHT LENS ABOVE ROW FOUR FELL OFF . REPORTED BY CREW / [01] REPLACED LENS COVER REF AMM 33-51-01SDR SWAA2022092074461None · inoperativeAFT ENTRY DOOR EMERGENCY LIGHT INOP / [01] RELAMPED AFT ENTRY DOOR EXTERIOR EMERGENCY LIGHT REF AMM 33-51-04. OPS CHK GOODSDR SWAA2022092070216None · brokenAFT SERVICE DOOR ASSIST HANDLE IS BROKEN / [01] REMOVED AND REPLACED HANDLE IAW AMM. 52-41-31.SDR SWAA2022101072195None · delaminatedLH O/B AFT FLAP LOWER SURFACE HAS DELAMINATED AREA 21 X 10 AT LOWER I/B CORNER. / [01] OK TO INSTALL L/H O/B AFT FLAP IAW AMM 27-51-22;[02] REMOVED AND REPLACED L/H O/B AFT FLAP PER AMM 27-51-22;[03] INSPECTION C/W CORRECTIVE ACTION STEP 2. L/H O/B AFT FLAP RESDR SWAA2022100672741None · crackedLT WING T/E WIGGLE PLATE CRACKED INBD OF #3 FLAP TRACK [MARKED]. / [01] REMOVED AND REPLACED DAMAGED WIGGLE PLATE PER SRM 51-40-02.;[02] PARTS DATA UPDATE ONLY;[03] RESTORED EXTERIOR PAINT FINISH PER AMM 51-21-99.;[04] C/W INSPECTION.SDR SWAA2022100571987None · corrodedCORROSION ON FLOOR BEAM UPPER CHORD BS 986 LBL45 WL 208 AT NUT PLATE HOLE / [01] VERIFIED APPLICABILITY IAW SRM 53-70-51-1A-1 AND SRM 53-70-51-2R-6 REPAIR 6;[02] REMOVED CORROSION ON FLOOR BEAM UPPER CHORD BS 986 LBL 45 WL 208; IN A 3.2' X 1.1' AREA; ORIGINAL SDR SWAA2022092670148Battery Pack · faultyM2816 EMERGENCY LTS BATTERY PACK NOT SUPPLYING POWER FOR LIGHTS / [01] INSTALLED AND PERFORMED GOOD INSTALLATION TEST AS PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2022092670149Battery Pack · faultyM1675 EMERGENCY LTS BATTERY PACK NOT SUPPLYING POWER FOR LIGHTS / [01] INSTALLED AND PERFORMED GOOD INSTALLATION TEST AS PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2022092670150Battery Pack · faultyM1673 EMERGENCY LTS BATTERY PACK NOT SUPPLYING POWER FOR LIGHTS / [01] INSTALLED NEW BATTERY AND TESTED GOOD AS PER AMM 33-51-06-960-805;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2022092670147Battery Pack · faultyM1672 EMERGENCY LTS BATTERY PACK NOT SUPPLYING POWER FOR LIGHTS / [01] COMPLETED INSTALLATION AND GOOD INSTALL TEST AS PER AMM 33-51-06-960-805;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2022091974465Hook · out of adjustFA REPORTS FWD ENTRY DOOR GIRT BAR STOWAGE HOOK IS LOOSE / [01] ADJUSTED GIRT BAR STOWAGW HOOK IAW S.I.P. <BR>OPS CHECK GOODSDR SWAA2022091974339Battery Pack · inoperativeAFT SERVICE DOOR EMERGENCY LIGHTS INOP / [01] REMOVED AND REPLACED AFT SERVICE DOOR EMERGENCY LIGHT BATTERY PACK IAW FIM 33-50 TASK 801. OPS CHECK GOOD.SDR SWAA2022091974487Battery Pack · inoperativeCEILING EMERGENCY AISLE LIGHTS INOP. AT ROWS 6; 10 AND 14 DEF RT. SIDE. / [01] T/S TO BATTERY PACK (M1676) BATTERY IN FRONT OF ROW 8 DEF BEHIND AIR RETURN GRILLE; NIS TPA; IAW WDM 33-51-12; FIM 33-50 TASK 801. <BR>OK TO CONTINUE PER MEL 33-15-02; SP-1.;[02] R&SDR SWAA2022100671980Support Angle · corrodedCORROSION ON FSD MOPSILL SUPPORT ANGLEBS294+10-BS 312+7 RBL 55 WL 209 / [01] VERIFIED SRM 53-10-15-1A-2 IS APPLICABLE. REMOVED CORROSION ON FSD MOPSILL SUPPORT ANGLE BS294+10-BS 312+7 RBL 55 WL 209 PER SRM 51-10-02. ORIGINAL THICKNESS IS .090'. MAXIMUM MATERIASDR SWAA2022100571977Floor Support · crackedFLOOR SUPPORT CRACKED BS 344+9 LBL 12 WL 208 / [01] REMOVED FLOOR SUPPORT AT BS 344-360 BL0 WL 208 FOR ACCESS AND REMOVED CRACKED FLOOR SUPPORT AT BS 344+9 LBL12 WL 208 PER SRM 51-40-02.;[02] CERTIFIED ACTION 1.;[03] LOCATED AND DRILLED NEW FLOOR SUPPORT AT BSSDR SWAA2022100571978Floor Support · crackedFLOOR SUPPORT CRACKED BS 380+7 LBL 14 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT AT BS 380+7 LBL 14 WL 208 PER SRM 51-40-02.;[02] LOCATED AND DRILLED NEW FLOOR SUPPORT AT BS 380+7 LBL 14 WL 208 PER SRM 51-40-05; DWG#143A5400. REQUEST OK TO INSTALL.;[03] VERIFSDR SWAA2022100571981Floor Support · crackedFLOOR SUPPORT CRACKED BS 277+7 BL0 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT AT BS 277+7 BL0 WL208 PER SRM 51-40-02.;[02] LOCATED AND DRILLED NEW FLOOR SUPPORT AT BS 277+7 BL0 WL 208 PER SRM 51-40-05; DWG#141A5400. REQUEST OK TO INSTALL.;[03] VERIFIED CORRECSDR SWAA2022100571979Floor Support · crackedFLOOR SUPPORT CRACKED BS 312+5 RBL 31 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT AT BS 312+5 RBL 31 WL 208 PER SRM 51-40-02.;[02] REMOVED CRACKED FLOOR SUPPORT AT BS 312+5 RBL 31 WL 208 PER SRM 51-40-02. UPDATED MEASUREMENT TABLE.;[03] LOCATED AND DRILLED NEWSDR SWAA2022100571982None · crackedMOPSILL INNER CHORD CRACKED BS 303.9 LBL 55 WL 209 / [01] UPDATED MEASUREMENTS. REMOVED FWD ENTRY DOOR MOPSILL IAW SRM 51-40-02.;[02] LOCATED AND DRILLED NEW FED MOP SILL IAW SRM 51-40-05-0G-0 AND BOEING DWG 141A8110 APPLIED CHEMICAL CONVERSION COAT AND PRIMEDSDR SWAA2022100571983Floor Support · crackedFLOOR SUPPORT CRACKED BS 312+9 LBL 43 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT BS 312+9 LBL 43 WL 208 PER SRM 51-40-02.;[02] LOCATED AND DRILLED NEW FLOOR SUPPORT PER SRM 51-40-05; DRW # 141A5400. REQUEST OK TO INSTALL.;[03] VERIFIED CORRECTIVE ACTION #2<BRSDR SWAA2022092970488Bracket · crackedR2 GALLEY SERVICE DOOR PANEL 844DZ;SHOWS FWD BRACKET CRACKED AT LWR EDGE.MKD / [01] REMOVED AND REPLACED R2 GALLEY SERVICE DOOR PANEL 844DZ IN REF WITH SRM 51-40-02-0G-0;[02] COORECTION TO STEP 1 REMOVED AND REPLACED R2 GALLEY SERVICE DOOR PANEL 844DZ FWD BRACSDR SWAA2022091974416Megaphone · inoperativeFA REPORTS AFT MEGA PHONE INOP / [01] PERFORMED OPS TEST OF AFT MEGA PHONE PER AMM 25-64-00; OPS TEST GOODSDR SWAA2022091972913None · delaminatedRH O/B AFT FLAP IS DELAMINATED ON BOTTOM I/B CORNER / [01] REMOVED AND REPLACED R/H O/B AFT FLAP PER AMM 27-51-22.
Back to Boeing 737-8H4