SDR SWAA2020080402135Angle · corrodedAFT CARGO PIT; RIGHT HAND Z-ANGLE UPPER SURFACE HAS CORROSION; STA: 727F TO 767; RBL: 22; WL: 154. / REMOVED CORROSION VERIFIED WITH 10X MAGNIFIED GLASS NO DEFECT NOTED IAW SRM 53-00-53-1A-2; VERIFIED MATERIAL LOST OGR .040' REMOVED .010' REMAIN .030' FOUND OUSDR SWAA2020080402134Angle · corrodedAFT CARGO PIT; LEFT HAND Z-ANGLE UPPER SURFACE HAS CORROSION; STA: 727H TO 827; LBL: 22; WL: 154. / ACCOMPLISHED Z-ANGLE REPAIR IN AFT PIT LH SIDE FROM STA 727E + 10' TO STA 847; LBL 22 WL: 154 I.A.W. SRM 53-00-53-2R-5 P/N 146A7502-31SDR SWAA2020072202125Battery · inoperativeFWD GALLEY RIGHT SIDE EMERGENCY FLASHLIGHT WAS INOPERATIVE. R & R THE FLASHLIGHT BATTERY IAW AMM 25-64-00.SDR SWAA2021081301610Angle · corrodedFORWARD CARGO COMPARTMENT BS500I; WL156; RBL24 - LBL24 FLOOR BULKHEAD ANGLE MULTIPLE AREAS OF CORROSION / REMOVED CORROSION ON FORWARD CARGO AFT BULKHEAD ANGLE IAW B737 SRM 51-10-02-0G-0 ORIGINAL MATERIAL WAS .080 MATERIAL REMOVED .020 MATERIAL REMAINING .060 SDR SWAA2021080301605Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL 120CF CORRODED / FABRICATED REPLACEMENT FLOOR PANEL IAW AMM 25-52-01-201-801 AND BOEING DRAWING 453A1610 REV - (120CF)SDR SWAA2021080301604Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL 120AF CORRODED / FABRICATED REPLACEMENT FLOOR PANEL IAW AMM 25-52-01-201-801 AND BOEING DRAWING 453A1610 REV F (120AF)SDR SWAA2021080301606Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL 120DF CORRODED / FWD CARGO FLOOR PANEL 120DF CORRODED. PANEL HAS 60' OF CORROSION ON RH SIDE TOP SURFACE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102 FABRICATED NEW PANEL 120DF P/N 453A1610-20 IAW AMM 25-52-01-201-801 AND BOEING DWG'S SDR SWAA2021060801616Shield · corrodedFORWARD CARGO COMPARTMENT; FLOOR SHIELD; BS492 - BS494; WL156; RBL24; CORRODED / REMOVED CORROSION FROM FWD CARGO AFT SHEILD STA 492 TO 494 RBL 24 IAW B737 SRM 51-10-02-0G-0. VERIFIED W/ 10X GLASS. FOUND IN LIMITS IAW B737 SRM 53-00-53-1A-2. ORIG .032' REMAIN SDR SWAA2020080401611Angle · corrodedFORWARD CARGO COMPARTMENT; Z-ANGLE; BS500I - BS400; WL 156; LBL24; MULTIPLE AREAS OF CORROSION / REMOVED CORROSION AT L/H AS MARKED FROM STA 500A TO 500I IAW SRM 53-00-53-1A-2 AND SRM 51-10-02-0G-0. VERIFIED WITH 10X MAGNIFICATION. ORIGINAL THICKNESS .040'; ATSDR SWAA2020080401573Angle · corrodedFORWARD CARGO COMPARTMENT; Z-ANGLE; BS500I - BS500A; WL156; RBL24; MULTIPLE AREAS OF CORROSION / BLENDED AND EVALUATED CORROSION ON FWD CARGO R/H Z ANGLE FROM STA 500A TO 500I WL 156 RBL 24 IAW B 737 SRM 51-10-02-0G-0 & 53-00-53-1A-2 FOUND OUT OF LIMITS WITH MSDR SWAA2020080301498Floorboard · damagedFWD GALLEY AREA FLOORBOARDS 222 DF DAMAGED.SDR SWAA2020073001497Floorboard · damagedFWD GALLEY AREA FLOORBOARDS 222 AF; 221 AF; 221 BF; 222 BF; 221 CF AND 221 DF WERE DAMAGED.SDR SWAA2020072201515Flashlight · not seatedFLASHLIGHT IN THE AFT GALLEY WAS INOPERATIVE. RESEATED THE AFT FLASHLIGHT IAW SIP.SDR SWAA2020072901590Handle · brokenMEGAPHONE HAS A BROKEN HANDLE. REPLACED THE MEGAPHONE IAW SWA DWG 25600008, REV D A48929.SDR SWAA2020072201572Light · inoperativeAFT SERVICE DOOR EXTERIOR EMERGERNY LIGHT WAS INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-04.SDR SWAA2021080301557Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL 140DF CORRODED / EVALUATED CORROSION ON AFT CARGO BAY FLOOR PANEL 140DF AND FOUND ACCUMULATED LENGTH OF DAMAGE TO BE MORE THAN 20' MAXIMUM ALLOWED - OUT OF LIMITS IAW SRM 53-00-53-1A-1; FABRICATED NEW PANEL 140DF IAW AMM 25-52-01-201-SDR SWAA2021080301555Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL 140EF CORRODED / EVALUATED CORROSION ON AFT CARGO BAY FLOOR PANEL 140EF; LENGTH OF TOTAL ACCUMULATED DAMAGE EXCEEDED 20' MAXIMUM ALLOWEABLE LENGTH - OUT OF LIMITS IAW SRM 53-00-53-1A-1; REPLACED WITH NEW/FABRICATED PANEL 140EF IAW AMMSDR SWAA2021080301556Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL 140BF CORRODED / FOUND CORROSION TO BE MORE THAN 20' IN LENGTH WHICH IS OUT OF LIMITS. FABRICATED NEW PANEL 140BF I/A/W AMM 25-52-01-201; SRM 53-00-53-1A AND DRAWING 453A2610 REV. KSDR SWAA2021080301553Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL 140AF CORRODED / EVALUATED CORROSION ON AFT CARGO PIT FLOOR PANEL 140AF CORROSION EXCEEDED THE 20 INCH ALLOWABLE LIMITS; OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102. FABRICATED NEW FLOOR PANEL IAW AMM 25-52-01-201-801 AND BOEING DRAWISDR SWAA2021080301554Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL 140CF CORRODED / EVALUATED CORROSION ON AFT CARGO PANEL 140CF CORROSION EXCEEDS THE 20 INCH ALLOWABLE LIMITS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102 FABRICATED NEW FLOOR PANEL IAW AMM 25-52-01-201-801 AND BOEING DRAWING 453A2610 SSDR SWAA2021042701569Skin · debondedLH WING #6 SPOILER LOWER SURFACE DENT #8 DISBONDED / REPAIRED #8 DENT WITH DISBOND ON LOWER SKIN OF #6 SPOILER. IAW B737800 SRM 5770010I1; SRM 5770012R2; SRM 5170102R2; SRM 5170102R0; AMM 512199300801.SDR SWAA2020080401580Angle · crackedRIGHT HAND A/C PACK BAY; HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT STATION 663 IS CRACKED 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE. MARKED. / REPAIRED RIGHT HAND A/C PACK BAY; HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANSDR SWAA2020080301581Angle · crackedLEFT HAND PACK BAY; HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT STATION 663 IS CRACKED 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE. MARKED. / REPAIRED LEFT HAND PACK BAY; HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK STA 663 SDR SWAA2021082091082Floor Panel · corrodedFWD PIT FLOOR PNL 120CF HAS CORROSION ON UPPER SURFACE ALONG LH AND RH EDGES / FWD PIT FLOOR PNL 120CF HAS CORROSION ON UPPER SURFACE ALONG LH AND RH EDGES EVALUATED CORROSION FOUND IT EXCEEDS 20' OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102 VERIFIED NEW MATERISDR SWAA2021080301088Doubler · corrodedAFT CARGO COMPARTMENT; FRAME; WL157; LBL21; BS747; CORRODED / AFT CARGO FRAME 747 LBL 21 CORRODED. BLENDED AND REMOVED CORROSION AND CHECKED WITH 10X MAG I/A/W 51-10-02-0G-0 SRM. 'OUT OF LIMITS' THICKNESS IS .063 MAT LOSS .010 REMAINING .053 I/A/W SRM 53-00-07SDR SWAA2021080300846Floor Panel · corrodedFWD PIT FLOOR PNL 120AF HAS CORROSION ON UPPER SURFACE ALONG FWD AND RH EDGES / EVALUATED CORROSION ON UPPER SURFACE ALONG FWD AND RH EDGES OF FWD PIT FLOOR PNL 120AF; TOTAL ACCUMLATED CORROSION DAMAGE FOUND TO EXCEED 20' MAXIMUM LENGTH ALLOWED - OUT OF LIMITSSDR SWAA2021080300845Floor Panel · corrodedFWD PIT FLOOR PANEL 120DF CORRODED IN MANY LOCATIONS ON TOP SIDE OF AFT AND RH EDGES. / EVALUATED FWD PIT FLOOR PANEL 120DF CORROSION EXCEEDED LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW FLOOR PANEL IAW AMM 25-52-01-201-801SDR SWAA2021070700841Support Angle · corrodedFWD PIT STA 500I BULKHEAD PANEL LWR SUPPORT ANGLE UPPER SURFACE CORRODED FROM LBL 20 TO RBL 23 / FWD PIT STA 500I BULKHEAD PANEL LOWER SUPPORT ANGLE UPPER SURFACE CORRODED FROM LBL 20 TO RBL 23 REMOVED AND REPLACED WITH NEW ANGLE P/N 143A9485Y35 IAW SRM 51-40-SDR SWAA2021060800840Shield · corrodedFWD PIT STA 500+6' FLOOR SHIELD UPPER SURFACE CORRODED AT RBL 23 AND WL157. / REMOVED CORROSION FROM PIT STA 500+6' FLOOR SHEILD UPPER SURFACE AT RBL 23 AND WL 157; ORIGINAL THICKNESS .050' REMAINING .045' LOSS .005' NO ALLOWABLE LIMITS ON PART OUT OF LIMITS. SDR SWAA2020080300836Floor Panel · damagedCABIN FLOOR PANEL 241AF FWD R/H CORNER IS MISSING CORE MATERIAL. REPAIRED CABIN FLOOR PANEL 241AF FWD R/H CORNER MISSING CORE IAW B737 SRM 53-00-50-2R-4 REV 69 ABD B737 SRM 53-00-50-2R-0 REV 69. A64736 A94414 A03261SDR SWAA2020080301085Angle · corrodedAFT CARGO COMPARTMENT; Z-ANGLE; WL156; LBL20; BS727E +15' - 727F +15'; CORRODED MULTIPLE LOCATIONS / AFT CARGO Z-ANGLE L/H SIDE STA 727E TO 727F+15' CORRODED BLENDED AND REMOVED CORROSION ON Z-ANGLE AND CHECKED WITH 10X MAG I/A/W SRM 51-10-02-0G-0 THICKNESS ISSDR SWAA2020080300844Angle · corrodedFWD PIT STA 500B TO 500G LEFT Z ANGLE CORRODED AT LBL 23 AND WL157 / REMOVED CORROSION AND EVALUATED MATERIAL LOSS ON FWD CARGO LH Z ANGLE FROM STA 500B TO 500G ORIGINAL 'T' .040' LOSS .010' REMAINING 'T' .030' FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 REPAIRESDR SWAA2020080300843Channel · corrodedFWD PIT STA 500A TO STA 500I RIGHT Z ANGLE UPPER SURFACE CORRODED AT RBL 23 AND WL157 / REMOVED CORROSION FROM FWD CARGO BAY RH ZEE ANGLE STA 500A TO STA 500I RBL 23 WL157 IAW SRM 51-10-02-0G-0 AND USED 10X MAG GLASS NO DEFECTS NOTED EVALUATED MATERIAL LOSS TOSDR SWAA2020072001103Floor Panel · damagedCENTER ISLE, POPPING SOUND BY ROW 16, PERFORMED A PERMANENT REPAIR BY REPLACING THE FLOOR PANEL OR RECTIFY IAW AMM 53-21-00/401.SDR SWAA2021082500327Angle · corrodedFWD CARGO LEFT TRANSITION ANGLE HAS LIGHT CORROSION FROM BS 500C-500I IN AND AROUND SEVERAL W/P HOLES / BLENDED LIGHT CORROSION IAW SRM 51-10-02; DAMAGE REMOVAL FROM STA 500G TO 500I WAS WITHIN LIMITS IAW SRM 53-00-53-1A-2. TREATED IAW SRM 51-20-01 & PRIMED IASDR SWAA2021052600325Gusset · crackedFWD CARGO GUSSET CRACKED BS 500 I STR 19R / REMOVED AND REPLACED DAMAGED GUSSET PER SRM 51-40-02.SAM 326 ATTACHMENT: A1184153SDR SWAA2020080300368Angle · crackedRH A/C PACK BAY. HORIZONTAL ANGLE COMMON TO LOWER CENTER FUEL TANK AT STATION 663 IS CRACKED 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE. / REPIARED R/H STA 663 HORIZONTIAL ATTACH ANGLE 3RD FASTENER O/B OF KEEL BEAM VERTICAL ANGLE IAW SRM 57-10-10-2R-5 RSDR SWAA2020073099920Floorbeam · corrodedAFT GALLEY FLOORBEAM STA 947.5 LBL 6 AND LBL 14 HAS CORROSION ON INSIDE AND AROUND AFT SCREW HOLES. REMOVED CORROSION AND REPAIRED IAW EA 20-153-01120 PART 1 AND 2K, AND SRM 53-70-51-2R-8.SDR SWAA2020072000238Battery Pack · inoperativeAFT O/B EMERGENCY FLASHLIGHT INOP / REPLACED EMERGENCY FLASHLIGHT BATTERY IN AFT GALLEY PER MM 25-64-00.SDR SWAA2020072000035Barrier · crackedRIGHT MLG WHEEL WELL; AFT SPAR VAPOR BARRIER CRACKED FROM RBL 31.83 TO RBL 34.83.5' DIAGONAL CRACK (10' FROM BOTTOM OF VAPOR BARRIER)PERFORMED INTERIM REPAIR IAW SRM 57-10-10. DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FRESDR SWAA2020072000034Barrier · crackedRIGHT MLG WHEEL WELL; AFT SPAR VAPOR BARRIER CRACKED FROM RBL 29 TO RBL 31.83 1.75' DIAGONAL CRACK ( 14' FROM BOTTOM OF VAPOR BARRIER)PERFORMED INTERIM REPAIR IAW SRM 57-10-10. DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FRSDR SWAA2021062499808Scuff Plate · crackedFWD CARGO DOOR CUTOUT; FWD CORNER SCUFF PLATE CRACKED / REMOVED AND REPLACED FORWARD CORNER SCUFF PLATE AT FORWARD CARGO I/A/W SRM51-40-02 AND AMM 53-11-02SDR SWAA2020073099787Angle · corrodedAFT GALLEY ZEE ANGLE BETWEEN FLOORBEAM 986.5 THRU BS 1016, RBL 30. GALLEY SUPPORT WAS CORRODED. REMOVED AND REPLACED THE ANGLE IAW SRM 51-40-02.SDR SWAA2020073099813Floor Support · corrodedINTERCOSTAL HAS CORROSION LBL 12, BS 294.5 - 312. REMOVED AND REPLACED THE INTERCOSTAL IAW SRM 51-40-02.SDR SWAA2020071599826Light · inoperativeONE EXTERIOR EMERGENCY LIGHT AT AFT SERVICE DOOR INOP. (EXTERIOR EMER LIGHT SYS) RELAMP PER AMM 33-51-04. OPS CHECK GOOD.SDR SWAA2020071500057Light · inoperativeEMERGENCY LIGHT C/B POPPED ON P6-11 A9. RESET BREAKER IAW AMM 20-60-01 AND PERFORMED OPS TEST IAW AMM 33-51-15 FOUND ON LIGHT INOP SEE LOGPAGE 1328992 FOR MEL.SDR SWAA2020071499581Flashlight · inoperativeFWD CABIN EMERGENCY FLASHLIGHTS INOP. R/R BOTH FWD CABIN FLASHLIGHTS IIAW AMM 25-64-00.SDR SWAA2020071499668Girt Bar · out of positionON FWD ENTRY DOOR, GIRT BARS ARE DIFFICULT TO LATCH AND STOW. (BOTH TO ENGAGE AND RELEASE TO STOW) REPOSITION GIRT BAR IAW AMM 25-66-01; CKD OK.SDR SWAA2020071499823Slide · out of positionAFT SERVICE DOOR ESCAPE SLIDE APPEARS DAMAGED. REPOSITIONED SLIDE IN COMPARTMENT PER MT 725-61-06.SDR SWAA2021071598952Support Angle · elongatedFORWARD CARGO COMPARTMENT; AFT BULKHEAD SUPPORT ANGLE AT STA. 500I; RBL 25; WL. 158; INBOARD FLOOR ATTACH HOLE IS ELONGATED WITH SHORT EDGE MARGIN. REFRENCE AAR EA 200436 REV. P1 STEP. 6 (VISUAL INSP. AREA). / FWD CARGO AFT BULKHEAD R/H SIDE SUPPORT ANGLE BEAM
Back to Boeing 737-8H4