Boeing 737-924ER
Service difficulty reports · 3,682
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016111800924Skin · crackedLEFT HORIZONTAL STAB HAS A CRACK AT STA 184.70. REPAIR IN REF SRM 55-10-01 REPAIR 11 , INITIATED A DIP TO PERFORM AN INPECTION PER SRM 55-10-01 REPAIR 11 , STEP 5 PAGE 218 , TABLE 204.SDR CALA2016111800923Battery Pack · inoperativeAFT RT EXIT EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-06.SDR CALA2016111400919Light · inoperativeLEFT AFT OVERWING EMERGENCY LIGHT INOP. RELAMPED PER AMM TASK 33-51-04-960-801.SDR CALA2016111400918Slide · unserviceableEMERGENCY EXIT SLIDE AT DOOR 2R IS COMING OUT OF ITS PACKING. REMOVED, REPLACED AND RESTOWED R-2 DOOR SLIDE PER AMM TASK 25-66-01-000-400-803 AND 25-66-000-802-400-801.SDR CALA2016111400917Battery · dischargedEMERGENCY FLASHLIGHT AT 1L IS INOP. REPLACED FLASHLIGHT BATTERY OPS CHECKS GOOD.SDR CALA2016110700865Warning System · false activationSPEED BRAKE DO NOT ARM LIGHT CAME ON DURING TAKEOFF, REJECTED AT 130 KTS. ACCOMPLISHED FIM TASK 27-62-00-810-802 AND SMD NR 2 BITE TEST NO CURRENT FAULTS, 11 LEGS AGO HAD MAINT MESSAGE 27-62002 (INTERNAL AUTOSTOW) INTERMITTENT FAULT. ACCOMPLISHED FIM TASK 27SDR CALA2016110400859Life Raft · low pressureFIRST CLASS AFT LIFE RAFT LOW. REMOVED AND REPLACED LIFE RAFT IAW MM 25-64-00.SDR CALA2016110400852Light · inoperativeR-2 DOOR EXTERIOR EMERGENCY LIGHT FAILED OPS CHECK. REMOVED AND REPLACED THE EMERGENCY EXIT SLIDE LIGHT (L733) BULB AT STATION 1000-WL242-RBL 60, IAW AMM 33-51-04 AND WDM 33-51-14. OPS CHECKED GOOD.SDR CALA2016103100844Battery Pack · dischargedEMERGENCY EXIT SEAT TRACK LIGHTS INOP AT ROWS 8 THROUGH 14 AND 22 THROUGH 34 REPLACED EMER PWR BATTERY PACKS AT M1670,M2503 & M2626,REF AMM 33-51-06-960-805. OPS CK NORMAL.SDR CALA2016103100843Bulb · inoperativeRED EMERGENCY EXIT SEAT TRACK LIGHT MISSING AT 15C. REPLACED RED LENS AND BULBS AT 15C. OPS CHECKED NORMAL.SDR CALA2016103100842Bulb · inoperativeEMERGENCY LIGHT AT LOWER RIGHT OF FWD CLOSET DOOR IS BROKEN. R & R LOWER RIGHT EMERGENCY LIGHT BULB,OPS NORMAL.SDR CALA2016103100837Bulb · inoperativeL2 EMERGENCY EXIT LIGHT IS INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT SLIDE LIGHT BULB IAW AMM33-51-04. OPS CHECKED OK.SDR CALA2016103100835Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M1674 WILL NOT HOLD A CHARGE. REMOVED AND REPLACED BATTERY PACK AT M1674 IAW AMM 33-51 -06 OPS CHECKED GOOD IAW AMM 33-51-00SDR CALA2016102800816Lens · missingLENS COVER MISSING FROM EXIT PATH LIGHTING BY DOOR 712 ON F/C CLOSET. INSTALLED LENS, ON PROXIMITY LIGHT, TEST OK AMM 33-51-00-710-801, CMM 25-20-23,33-51-02. OKSDR CALA2016102400813Lens · missingEMERGENCY LIGHT OUT AT 1B. FOUND FWD CLOSET AFT EMERGENCY LIGHT LENS MISSING, LIGHT OPS NORMAL. REPLACED LENS.SDR CALA2016102400812Slide · detachedR2 DOOR SLIDE IS HANGING DOWN. REPLACED THE SLIDE PACK IAW AMM 25-66-01SDR CALA2016102400804Skin · gougedAT BS 380 BETWEEN STRINGERS 7 AND 8L, THERE IS A GOUGE IN THE SKIN IAW ECRA 5331-02120 . THE SKIN WAS REPAIRED IAW SRM 53-00-01 REP 3 TABLE 204SDR CALA2016102400803Skin · crackedRIGHT HORIZONTAL STAB LOWER IN SPAR SKIN HAS A CRACK INDICATION AT HSS 157.10, ABOUT 9.5" AND 16.5" FROM AFT SPAR. THE SKIN WAS REPAIRED IAW SRM 55-10-01 REP 11.SDR CALA2016102100798Skin · crackedREF EA 5510-01843 REV E, RIGHT HORIZONTAL STABILIZER LOWER SKIN CRACK LOCATION FOUND AT STA 101.90 AT 19"AND 28" FROM FWD SPAR. RT STAB LOWER INSPAR SKIN HAS BEEN REPAIRED IAW SRM 55-10-01 REP 11 1. COMMON DOUBLER INSTALLED OVER BOTH AREAS.SDR CALA2016101900792Selector Valve · unserviceableLDG GEAR DID NOT RETRACT ON DEPT REF LOG 4812443. JACKED AC PER TASK 07-11-01-580-815. ACCOMPLISHED 10 GEAR SWINGS. NO FAULTS OR HYDRAULIC LEAKS. REPLACED LANDING GEAR SELECTOR VALVE.SDR CALA2016101900786Battery Pack · dischargedFIRST CLASS EMERGENCY LIGHTS INOP. REMOVED AND REPLACED RIGHT FWD EMERGENCY LIGHT BATTERY PACK IAW MM 33-51-06 OP CHECKED GOOD.SDR CALA2016101700761Engine · vibrationDURING INITIAL CLIMB STRONG VIBRATION, NR 1 ENGINE STRONG VIBRATION NR 1 ENG SURGED/TORCHED STRONG BURNING SMELL. LANDED OVERWEIGHT 165,000 ACCOMPLISHED NR 1 ENG BORESCOPE PER AMM 72-00-00-200-804-FOO, NO LIMITING DEFECTS FOUND. ACP'D OVERWEIGHT LANDING INSPSDR CALA2016101700760Oven · contaminatedSTRONG ACRID SMELL COMING FROM OVEN 423. REMOVED BURNT PAPER FROM OVEN 423 REF MM05 -51-26. INSPECTED OVEN 423, NO DEFECTS FOUND. OPS CKED OVEN FOR ABOUT 90 MIN AND COMPARED IT WITH OTHER OVENS, NO DEFECTS NOTED. OVEN 423 CKED NORMAL.SDR CALA2016101700773Light · inoperativeLEFT HAND SIDE AFT LOWER EMERGENCY SLIDE LIGHT INOP. REMOVED AND REPLACED LAMP AT LEFT HAND SIDE AFT LOWER EMERGENCY SLIDE LIGHT IAW AMM 33-57-04 AND OPS CHECK GOOD.SDR CALA2016101700759Actuator · failedHORIZONTAL STAB ACTUATOR FAILED WITH DISCOLORED WATER FROM BALL NUT. REMOVED AND REPLACED HSTA IAW AMM 27-41-81-400-801 AND EA 2740-01227 OPS 3 OPS 4.SDR CALA2016100300713Slide · unserviceableDOOR 1R SLIDE SLIGHTLY DEPLOYED WITH GIRT BAR ATTACHED. REPLACED SLIDE REF TASK 25-66-01-400-804SDR CALA2016092900706Charger · inoperativeEMERGENCY EXIT LIGHTS INOP ROWS 20 AND 21 R+R M1694 BATTERY AND CHARGER. OPS CHECK GOOD.SDR CALA2016092900702Overheat Loop · failedRIGHT WING TO BODY OVERHEAT LIGHT INFLIGHT DID NOT EXTINGUISH. TROUBLESHOT IAW FIM 28-18-00-810-802. FOUND LOOP FAILED M1764 PER STEPS H (4) (D) 3. REPLACED M1763 AND M1764 IAW AMM 26-18-02. TESTED OKSDR CALA2016092600687Wire Harness · damagedBROKEN EMERGENCY LIGHT WIRE HARNESS FROM WALL AT ROW 27 ABC. REMOVED AND REPLACED THE WIRE HARNESS IAW SWPM 20-60-02, OPS CHECKED GOOD IAW AMM 33-51-00.SDR CALA2016092200672Light · malfunctionedOVERHEAD LIGHTS IN CENTER SECTION OF CABIN FLICKERING. NEAR EMERGENCY EXIT. LED SEGMENTS OVER SEATS 15ABC AND 14 DEF ARE INOPERATIVE. THE REST OF EACH LIGHT BAR LED SEGMENTS ARE ON. OPS SEVERAL TIMES CABIN LIGHTS COULD NOT DUPLICATE PROBLEM.SDR CALA2016091500655Light · malfunctionedEMERGENCY LIGHTS AT SEATS 28 THRU 34 ABC AND OVERHEAD EMERGENCY LIGHTS STAY ON ALL THE TIME. COCKPIT SWITCH POS. AND / OR POWER CONFIG. OF ACFT HAVE NO EFFECT. ALL OTHER EMERGENCY LIGHTS INOP ALL THE TIME, IN ALL MODES. BATTERY PACK & POWER SUPPLY TEST IAW ASDR CALA2016090900643Lamp · inoperativeRT WING FWD EMERGENCY EXIT OVERWING SLIDE LAMP WILL NOT ILLUMINATE AND LENS IS CRACKED. REPLACED RT OVERWING SLIDE FWD LAMP AND LENS. OP CHK GOOD REF AMM 33-51-04.SDR CALA2016090600634Lens · out of positionEMERGENCY LIGHTS AT SEAT 20C HAS BEEN PUSHED INTO FLOOR AND NOT VISIBLE. R & R THE RED LENS. OPS CHECKED GOOD.SDR CALA2016090600621Lamp · inoperativeEMERGENCY LIGHT AT SEAT ROW 20 ABC INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-11 OPS CHECKED GOOD.SDR CALA2016090100615Skin · crackedLEFT HORIZONTAL STABILIZER LOWER SURFACE HAS THREE CRACKS AT HSS 129.50. FOUND FOURTH CRACK ON LOWER SKIN JUST FORWARD OF REAR BETWEEN HSS 129.50 AND 120.30. REPAIRED IAW SRM 55-10-01 REPAIR 11.SDR CALA2016082500584Actuator · inoperativeIAW CREW VERBAL, CREW COULD NOT PRESSURIZE AND RETURNED TO DEPARTURE. PRESSURIZED OK OFF APU. PACK/ZONE TEMP CONTROLLER BITE SHOWS SRADA EXHAUST FAULT. R & R RAM AIR EXHAUST ACTUATOR. BITE TEST PASSES AND OPS CHECKED RT PACK NORMAL. REF AMM 21-51-27. EVASDR CALA2016082500583Flap · malfunctionedHUNG FLAPS AND RETURNED TO DEPARTURE. CHECKED FSEU FAULTS. T/E FLAP LOAD RELIEF GROUND TEST PASS. VISUAL FLAP INSPS SATISFACTORY. FLAPS FUNCTION CHECK SATISFACTORY. OK TO CONTINUE.SDR CALA2016082400578Power Supply · inoperativeEMERGENCY EXIT LIGHTS INOPERATIVE ROWS 21-26 ABC. REPLACED THE BATTERY PACK ON POWER SUPPLY IAW MM33-51-06-960- 805, OPS CHECKED GOOD.SDR CALA2016081800546Lamp · inoperativeFOUND DURING 2SVC, LEFT OVERWING EMERGENCY LIGHTS AND INSIDE CABIN FROM 22C TO 27C EMERGENCY LIGHTS INOPERATIVE. REPLACED THE OVERWING LAMPS IAW MM 33-51-04-960-801. ALL EMERGENCY LIGHTS OPS CHECK GOOD.SDR CALA2016080900513Warning Light · false activationREJECTED TAKEOFF AT 40KTS DUE TO AMBER SPEED BRAKE DO NOT ARM LIGHT ILLUMINATING, ILLUMINATED AGAIN DURINGRETURN TO GATE. PERFORMED LOW SPEED ABORT INSPECTION 05-51-07-210-801.NO FAULTS NOTED.SDR CALA2016080100486Flap System · malfunctionedLE FLAP TRANSIT ON WHEN FLAP 1 SELECTED IN FLT. PERFORMED FSEU BITE CHECK, NO EXITSTING FAULT. NO LE FLAP FAULT HISTORY, BUT TE FLAP SNSR L 27-52259 ON LEG 0 ONLY. PERFORMED FIM TASK 27-51 TASK 813. OPS CHECKED LE & TE FLAPS FOR 3 CYCLES, CHECKED NORMAL, SDR CALA2016080100480Oven · contaminatedFWD GALLEY OVEN 204 STARTED TO SMOKE WHEN TURNED ON. FLIGHT ATTENDANT SAID THERE IS SOMETHING STUCK IN HEATING ELEMENT. SOURCE IDENTIFIED AS FOOD IN OVEN 204. COMPLIED WITH AMM 05-51-26 AND REPLACED OVEN 204 WITH NO OTHER DISCREPANCIES NOTED AT THIS TIME.SDR CALA2016080100477Oven · smokeDURING TAKEOFF ROLL, PLASTIC OR ELECTRICAL ODOR IN FLT DECK AND SMOKE AND ODOR IN CABIN. RETURNED TO DEPARTURE AND LANDED. FOUND OVEN IN FWD GALLEY WITH STRONG BURN ODOR. REMOVED AND REPLACED THE OVEN IAW AMM 25-34-00. REPLACED RECIRCULATION AIR FILTERS ISDR CALA2016072800464Housing · looseEMERGENCY LIGHT AT SEAT 26C FOUND LOOSE. SECURED LIGHT IN PLACE. REPLACED LIGHT HOUSINGSDR CALA2016072800463Battery Pack · dischargedEMERGENCY LIGHTS INOPERATIVE, AFT RIGHT SERVICE DOOR. R & R THE BATTERY PACK. LIGHTS CHECKED NORMAL.SDR CALA2016070100401Indicator · inoperativeON APPROACH TO DEN SLEECTED FLAPS 1. TRAILING EDGE SPLIT BETWEE N 0-1. PERFORMED CHECKLIST. FLAPS LOCKED 0-1. V REF 179 TARGET 184. FOUND L IND NEEDLE WITH LARGE LAG FROM R NEEDLE. FSEU CODE: 27- 52259. REPLACED FLAP INDICATOR PER AMM 27-50-02-400-801. FSEU F SDR Z6WR20160621001Panel · delaminatedUPON REMOVAL OF THE 315A2130 BLANKET INSTALLATION, VISUAL AND ULTRASONIC INSPECTION OF THE 315A2101-177 BONDED PANEL ASSEMBLY, CMM 78-31-26, FIG 6, ITEM 40A, REVEALED 6 AREAS OF THERMAL DEGRADATION RESULTING IN DELAMINATION C/T THE-177 BONDED PANEL ASSEMBLY. SDR CALA2016052600329Light · inoperativeEXTERNAL EMER LIGHT AFT OF L2 DOOR INOPERATIVE. R & R THE EXTERNAL EMER LIGHT BULB AFT OF THE L2 DOOR & OPERATIONS CHECKED GOOD IAW AMM 33-51-04. PN 767 IDT.SDR CALA2016051600298Clamp · looseON TAKEOFF AT 25KTS WW FIRE LIGHT & BELL INDICATION. REJECT TAKEOFF RUN FOUND CLAMP LOOSE ON PNEUMATIC DUCT IN THE NR 2 PACK BAY, SECURED & RAN ENG HIGH POWER. OPERATIONS CHECKED GOOD WITH NO LEAKS.SDR CALA2016050600287Unknown · odorON TAKEOFF ROLL & CONTINUING THRU INITIAL CLIMB OUT, A STRONG ODOR, SIMILAR TO THE HOT GALLEY OVEN, WENT THRU THE AIR DUCTS FROM COCKPIT TO REAR GALLEY, BY APPROX 10,000 FT. IT DISSIPATED FROM ACFT WITHIN 10 TO 15 MINS, ALL ACFT SYS PERFORMED NORMAL. PERFORM
Back to Boeing 737-924ER