Boeing 737-990ER
Service difficulty reports · 10,341
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737990ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737990ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2015012810470Warning Light · false activationBLUE APU " MAINT" LIGHT ON WITH APU START ON GROUND. ACFT GROUNDED. APU OIL QTY SHOWS FULL ACCOMPLISHED APU BITE IAW FIM 49-60, TASK 801 CURRENT STATUS SHOWS MSG 49-11019, DC POWER LOSS SHUTDOWN ACCOMPLISHED FIM 49-10, TASK 801 APU START & SHUTDOWN NORMAL WISDR ASAA2015012810464Warning Light · illuminatedTR UNIT LIGHT ILLUMINATED AFTER POWER TRANSFER FROM APU GENERATOR TO ENGINE GERNERATORS. ACFT GROUNDED. CYCLED POWER ON AND OFF SEVERAL TIMES, AND TRANSFERRED POWER BETWEEN APU AND GROUND WITH NO DISCREPANCIES NOTED. ACCOMPLISHED FIM 24-31, TASK 826 WITH NO SDR ASAA2015012710454Hf Comm · malfunctionedHF-2 SHOWS FAILED WHEN SELECTED. ACFT GROUNDED. ACCOMPLISHED FIM 23-11, TASK 802. HF 2 OPERATION RESTORED. GROUND VERIFICATION TEST NORMAL REF FIM 23-11, TASK 801. NO PREVIOUS HISTORY.SDR ASAA2015012710453Satcom · malfunctionedDURING CRUISE, NOTICED NO SATCOM ON MCDU MENU PAGE. ACFT GROUNDED. PERFORMED SATCOM ADJUSTMENT TEST IAW AMM 23-15-00. SYSTEM RESTORED. NO HISTORY PAST 30 DAYS. GROUND VERIFICATION CHECKED NORMAL. OK FOR CONTINUED SERVICE.SDR ASAA2015012610440Warning System · false activationACFT WAS ALIGNED WITH THE LT EDGE OF THE RUNWAY DURING AUTOLAND AT APPROXIMATELY 100 FT. RECEIVED APPROACH WARNING AT 50 FT. ACFT GROUNDED. TROUBLESHOT IAW FIM REF 22-11, TASK 825. PERFORMED LAND VERIFY TEST IAW AMM TASK 22-11-00-700-801. TEST PASSED NO FASDR ASAA2015012610438Warning Light · false activationON RECALL, LEFT PACK LIGHT ILLUMINATED - IT RESET WITH PUSHING THE MASTER CAUTION. ACFT GROUNDED. UNABLE TO DUPLICATE DEFECT. BITE OF PACK ZONE TEMP CONTROLLERS IAW MM 21-61-00-700-806-002 SHOWED NO FAULTS AND VERIFY TESTS PASSED. OPERATED LT PACK AT VARIOUSSDR ASAA2015012610437Warning Light · false activationRIGHT RAM DOOR ILLUMINATED DURING CRUISE FLIGHT. ACFT GROUNDED. PERFORMED A GVI RAM INLET, NORMAL NO FOD IN INLET. ACCOMPLISHED FIM TASK 21-51, TASK 803 BOTH INLET OPERATES NORMAL. NO HISTORY IN LAST 30 DAYS.SDR ASAA2015012510411Control Module · failedAIR TEMP SELECTOR ON OVERHEAD PANEL IN FWD SUPPLY DUCT POSITION INDICATES 0-100 AT TIME, ALSO INDICATES A HIGH TEMP. F/A INDICATE CABIN TEMP IS OK. ACFT GROUNDED. VERIFIED DISCREPANCY. R & R TEMPERATURE CONTROL MODULE REF MM 21-61-15. OPS CKS NORMAL REF MSDR ASAA2015012410398Fmc · malfunctionedWEIGHT & BALANCE NUMBERS FROM ACARS NOT INTERFACING CORRECTLY WITH FMC ON TRIM & POWER SETTINGS. ACFT GROUNDED. VERIFIED FAULT. OPEN 4 C/B'S, 2 FOR RT FMC & 2 FOR ACARS CMU AND CLOSED SAME 4 C/B'S. VERIFIED WEIGHT & BALANCE NUMBERS'S & TRIM & POWER SETTINGSDR ASAA2015012410394Cover · missingEMERGENCY EXIT LIGHT COVER MISSING AT ROW 17, LT SIDE. ACFT GROUNDED. R & R EMERGENCY EXIT LIGHT ASSY L1507 EMERGENCY LIGHTS, OPS NORMAL IAW 33-51-00.SDR ASAA2015012410387Valve · failedCONTOL CABIN ZONE TEMP ILLUMINATES ON MC RECALL, RESETS WITH MASTER CAUTION. CONTROLLABLE WITH CONTROL CABIN TEMP SELECTOR. ACFT GROUNDED. PERFORMED PACK ZONE TEMP. CONTROLLER BITE TEST IAW AMM 21-61-00. FOUND FAULT ON CONTROL CABIN TRIM AIR MODULATING VALSDR ASAA2015012210404Start Valve · failedSTART VALVE NR 1 STAYED OPEN AFTER START. ACFT GROUNDED. R & R NR 1 ENG START VALVE IAW AMM 80-11-03. NR 1 ENG START VALVE TESTS GOOD. ETOPS GROUND VERIFICATION SUCCESSFUL.SDR ASAA2015012210397Radar · malfunctionedRADAR IN AUTO MODE DID NOT PAINT KNOWN WEATHER. MANUAL MODE DISPLAYED SAME ALTITUDE WEATHER ON 80 MILE SCALE WITH 3 DEG NOSE DOWN. ACFT GROUNDED. ACCOMPLISHED WEATHER RADAR SYSTEM BITE REF 34-43, TASK 801. WEATHER SYSTEM OPS TEST REF AMM 34-43-00-710-802-001SDR ASAA2015012110346Fmc · failedDUAL FMC FAILED IN CRUISE. ACFT GROUNDED. ACCOMPLISHED RT FMC BITE REF FIM 34-61, TASK 801. FOUND FAULT LOGGED IN FLIGHT LEG 4 ONLY, NO CURRENT FAULTS. GROUND VERIFICATION TEST PASSED, REF MM 34-61-00.SDR ASAA2015012010320Controller · malfunctionedON RECALL, FWD CABIN ZONE TEMP LIGHT ILLUMINATED TEMP SHOWS 52 DEG C WAS UNABLE TO CONTROL THE TEMPERATURE OR GET LIGHT TO GO OUT WITH CHECKLIST. ACFT GROUNDED. PERFORMED BITE TEST OF BOTH CABIN/ ZONE TEMP CONTROLLERS NR 2 CONTROLLER SHOWED ZONE FAULT. RESETSDR ASAA2015011910293Valve · malfunctionedFWD CABIN ZONE TEMP LIGHT ON RECALL, GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. RT PACK/ZONE TEMP CONTROLLER, M1443, SHOWS NUMEROUS FWD CABIN ZONE TRIM AIR VALVE, V144, FAULT. REPLACED FWD CABIN ZONE TCV REF AMM TASK 21-61-21, LEAK CK AND GROUND FUNCTSDR ASAA2015011810279Window · failedDURING TAXI OUT, CAPTAIN`S SIDE WINDOW OVERHEAT LIGHT ILLUMINATED. PERFORMED QRH PROCEDURE AND LIGHT CAME BACK ON. ACFT GROUNDED. ACCOMPLISHED WHCU BITE FOR CAPT SIDE WINDOW, SEVERAL WINDOW SENSOR FAULTS. IAW FIM 30-41, TASK 801. LT SIDE WINDOW WILL NOT SDR ASAA2015011810274Knob · looseCONDITION AIR TEMP SELECTOR ON OVERHEAD PANEL IS NOT WORKING. ACFT GROUNDED. FOUND AIR TEMP SELECTOR ASSY MOUNTING HARDWARE WASHER/NUT VERY LOOSE CAUSING AIR TEMP SELECTOR ASSY TO ROTATE WHEN KNOB TURNED. TIGHTENED MOUNTING HARDWARE, AIR TEMP SELECTOR PROPESDR ASAA2015011710281Blower · failedWEATHER RADAR RT BLOWER INOPERATIVE. ACFT GROUNDED. REPLACED BLOWER MOTOR REF MM 34-43-51 AND REINSTALLED R/T. OPS NORMAL.SDR ASAA2015011410264Filter · dirtyF/A REPORTED HOT IN CABIN ROW 6 TO ROW 15. REST OF CABIN COMFORTABLE BOTH FORE AND AFT. BITE CHECKED BOTH ZONE TEMP CONTROLLERS REF FIM 21-62, TASK 801. NO FAULTS. FOUND FWD CABIN TEMP SENSOR FILTER CLOGGED. CLEANED IAW MM 21-61-06. VERIFIED FWD CABIN DUSDR ASAA2015011410263Filter · dirtyEXCESSIVE HEAT IN CABIN AT ROWS 7-9 OBSERVED BY MULTIPLE PASSENGERS AND F/A. THE TEMPERATURE IN THE REST OF THE CABIN WAS NORMAL. THE SUPPLY DUCT AIR TEMPERATURE FOR BOTH FWD AND AFT WAS 20 DEGREES C. PASSENGER CABIN AIR TEMP BOTH FWD AND AFT WAS 21 DEGREESSDR ASAA2015011310262Warning Message · false activationFMC DISAGREE ON GROUND. ACFT GROUNDED. CHECKLIST ACCOMPLISHED. OPS NORMAL.SDR ASAA2015011310261Warning Message · false activationFMC DISAGREE DURING TAXI . ACFT GROUNDED. QRC FOLLOWED. OPS RESTORED NORMAL.SDR ASAA2015011310260Cover · dislodgedEXIT LIGHT COVER FWD GALLEY CAME OFF. ACFT GROUNDED. REINSTALLED FWD GALLEY EXIT LIGHT COVER.SDR ASAA2015011310258Autoland Sys · malfunctionedLOW WEATHER/AUTOLAND HOUSING PERFORMANCE NOTED BELOW. ACFT TOUCHED DOWN LEFT OF CENTER LINE. RT MAIN ON RWY CENTERLINE. ACFT GROUNDED. ACCOMPLISHED FIM 22-11 TASK 825. OPS TEST GOOD. DFCS FAULT REVIEW & HGS FAULT REVIEW. SHOWS NO FAULTS. NO HISTORY LAST SDR ASAA2015011210240Roller · looseF/O R2 WINDOW DIFFICULT TO CLOSE. ACFT GROUNDED. FOUND FORWARD LOWER ROLLER ON R2 WINDOW TO BE LOOSE, FALLING OFF. REINSTALLED NEW FWD GLIDE BEARING BOLT REF AMM 56-12-11-820-801 WITH OPS/FORCE CHECK GOOD.SDR ASAA2015011210237Warning Message · false activationFMC DISAGREE ILLUMINATED DURING TAXI OUT. ACFT GROUNDED. RAN QRH RESOLVED ISSUE.SDR ASAA2015011210236Warning Message · false activationFMC DISAGREE ON BOTH ND AFTER LANDING. ACFT GROUNDED. PERFORMED FIM TASK 34-61, TASK 835, NO DEFECTS NOTED ACFT OK FOR SERVICE.SDR ASAA2015011110226Keyboard · intermittentF/O MCDU LINE SELECT KEY L-1 INTERMITTENT. ACFT GROUNDED. R & R FMCS CDU KEY BOARD, OPS CK NORMAL REF MM 34-61-01.SDR ASAA2015011010192Circuit Breaker · trippedCIRCUIT BREAKER AUTOTHROTTLE DC-1 ON P18-1 E, IS TRIPPED ON PRE-FLIGHT INSPECTION. ACFT GROUNDED. FLIGHT LEG NR 1 SHOWS 8 FAULTS FOR 28V INVALID AT LANDING, ELEV 385, SUSPECT SEATBELT. IAW MM 20-60-01, RESET AT DC-1 CIRCUIT BREAKER, PERFORMED REQUIRED LWMP SDR ASAA2015010910200Warning Message · false activationFMC DISAGREE DURING TAXI OUT. ACFT GROUNDED. QRH PROCEDURE PERFORMED. OPS NORMAL. OK TO SERVICE.SDR ASAA2015010910199Terminal · failedRT SIDE OVERHEAT LIGHT ILLUMINATED ON COCKPIT WINDSHIELD. ACFT GROUNDED. FOUND ON RT SIDE SLIDE WINDOW, HEAT CONTROL UNIT SENSOR FAULT. SWITCHING TO SPARE SENSOR IAW WD 30-41-11. NO HELP, DUE TO TERMINAL C FAILING. CHECKED WINDOW TAP FOR H-15 ON TB5014. ISDR ASAA2015010910190Warning Light · false activationCAPTAIN'S PFD HAS AN AMBER "FD" INDICATION. ALSO, THE MCP CAPT SIDE F/D ON SWITCH/LIGHT WILL NOT INDICATE ON WHEN SELECTED FIRST. ALSO, AUTOPILOT A WILL NOT ENGAGE. ACFT GROUNDED. DUE TO FAULTY GATE POWER FCC-A FAULTED. TRANSFERRED TO APU POWER. FCC-A RETUSDR ASAA2015010810195Satcom · malfunctionedSAT PROMPT MISSING ON MENU ON GROUND. ACFT GROUNDED. PERFORMED QRH PROCEDURE. PROMPT REAPPEARED ON MCDU.SDR ASAA2015010810193Servo · failedAUTOTHROTTLE INOPERATIVE. ACFT GROUNDED. CURRENT STATUS TEST GOOD BUT SERVO MOTOR TEST FAILS ASM 2. WILL NOT MOVE. FLIGHT FAULT REVIEW SHOWED SEVERAL ASM 2 FAILURES IN FLIGHT. CONFIRMED ASM 2 BAD. REPLACED ASM 2. OPS NORMAL REF MM 22-31-91.SDR ASAA2015010810187Autoland Sys · malfunctionedAUTOLAND UNSATISFACTORY, AIRCRAFT DRIFTED TO THE RT AT APPROXIMATELY 100' FOLLOWED BY APPROACH WARNING. ACFT GROUNDED. FLIGHT FAULT REVIEW SHOWS NO FAULTS LOGGED. ACCOMPLISHED LAND VERIFY IAW FIM TASK 22-11, TASK 825. NO FAULTS. NO HISTORY LAST 10 DAYS. SDR ASAA2015010610164Warning Light · illuminatedZONE TEMP LIGHT ILLUMINATED ON RECALL, FWD CABINE. ACFT GROUNDED. NR 2 TEMP CONTROLLER LOGGED ZONE TEMP VALVE. RAN BOTH TEMP CONTROLLERS BITE TEST IAW MM TASK 21-61-00-700-806-002 AND CLEARED FAULT. RAN PACKS AND CABIN TEMP RESPONDED ACCORDING TO SELECTIONSDR ASAA2015010610163Warning Message · illuminatedCONT CABIN ZONE TEMP LIGHT COMES ON WITH RECALL AND EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 2 TEMP CONTROLLER LOGGED FLT DECK TRIM AIR FAULT LAST FLT. NO HISTORY LAST 30 DAYS. PERFORMED FIM 21-62 TASK 842 & FAULT CLEARED. GROUND VERIFICATSDR ASAA2015010610161Actuator · failedFWD CABIN ZONE, TEMP LIGHT ILLUMINATES ON MASTER CAUTION RECALL ONLY-RESETS WITH MASTER CAUTION. ACFT GROUNDED. RIGHT RAM AIR DEFLECTOR DOOR STICKS IN THE GROUND POSITION FOUND DURING T/S. PERFORMED FIM 21-62 TASK 843, NR 2 CONTROLLER LOGGED FWD ZONE TEMP VSDR ASAA2015010510155Warning Message · false activationON THE GROUND, AFTER ENGINE START RECEIVED A FMC DISAGREE MESSAGE. ACFT GROUNDED. PERFORMED QRH FMC DISAGREE PROCEDURE. NORMAL OPS RESTORED.SDR ASAA2015010410148Transmitter · failedAFTER LANDING NR 1 ENGINE OIL FILTER BYPASS LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED BITE CHECK, NOTED MSG 79-31121 OIL FILTER SIGNAL DISAGREE NR 1 ENGINE. REF TASK 79-05, TASK 817. PERFORMED TASK 79-21, TASK 806, H, 1-10 NO DEFECTS NOTED. PERFORMED FIMSDR ASAA2015010410146Fmc · malfunctionedDURING CRUISE, LT FMC FAILED. CHECK LIST COMPLETED. FMC SWITCH PLACED TO BOTH ON RT NORMAL, OPS RESTORED ON SINGLE FMC. ACFT GROUNDED. NO HISTORY LAST 30 DAYS. PERFORMED FIM 34-61 TASK 836 & NORMAL OPS RESTORED, DUAL FMC. GROUND FUNCTIONAL TESTS PASSED IAW SDR ASAA2015010410144Smoke Detector · dirtyAFT CARGO FIRE LIGHT FAULT DETECT IN NORMAL MODE LIGHT IS INTERMITTENT. ACFT GROUNDED. CLEANED ALL 3 AFT CARGO COMPARTMENT LOOP A SMOKE DETECTORS IAW MM 26-16-01. DURING CLEAN, FOUND DETECTOR A1, M2242, WITH DAMAGED COMPONENTS ON CIRCUIT BOARD. R & R M2242SDR ASAA2015010410143Autoland Sys · malfunctionedPRACTICE AUTOLAND COMPLETED. ACFT TOUCHED DOWN OUTSIDE 35 FT CENTERLINE LIMIT SO DEEMED NOT SUCCESSFUL. ACFT GROUNDED. PERFORMED FIM 22-11, TASK 825, NO FAULTS AND LAND VERIFY NR 49 BITE TEST GOOD.SDR ASAA2015010410141Warning Light · illuminatedPACK LIGHT ILLUMINATED ON RECALL, DURING AFTER START CHECKLIST, EXTINGUISHED W/MASTER CAUTION RESET. ACFT GROUNDED. LT PACK LIGHT AND SYS OPERATED NORMALLY DURING FLIGHT. NR 1 TEMP CONTROLLER BITE AND OPS NORMAL IAW FIM 21-62, TASK 801. NO HISTORY, GROUND VSDR ASAA2015010310123Controller · unsecureRIGHT "RAM DOOR FULL OPEN" LIGHT ILLUMINATED AT CRUISE. ACFT GROUNDED. FOUND MULTIPLE FAULTS & NOTICED THE ZONE 2 TEMP CONTROLLER WAS UNSEATED, OUT OF PLACE BY .2500. SEATED ZONE 2 TEMP CONTROLLER & SECURED WITH LOCK KNOBS. ZONE TEMP CONTROLLER INTERROGATSDR ASAA2015010310126Charger · malfunctionedELECTRIC LIGHT ILLUMINATED ON OVERHEAD PANEL. ACFT GROUNDED. REPLACED AUXILLARY BATTERY CHARGER, OPS TEST NORMAL, IAW MM 24-31-31.SDR ASAA2015010310135Warning Message · false activationFMC DISAGREE ON TAXI OUT. ACFT GROUNDED. ACCOMPLISHED QRH PROCEDURES WHICH FIXED PROBLEM.SDR ASAA2015010210129Charger · malfunctionedELECTRIC LIGHT ILLUMINATED ON APU START TIME FOR MORNING LAUNCH FAULT WAS AUX BATTERY CHARGER INOPERATIVE AND WAS RESET. ACFT GROUNDED. FAULT RESET NORMAL. OPS NORMAL IAW MM 24-31-31-710-801. CHECKED WIRE FROM D652 PIN 8 AT ELECT METERS P5-13 TO D10342 AUX SDR ASAA2015010110133Fmc · malfunctionedVTK AND MAP FLAGS APPEARED ON LT ND. RAN QRH PROCEDURE. SINGLE FMC OPERATIONS RESTORED WHEN FMC SELECT SWITCH POSITIONED TO BOTH ON RT. ACFT GROUNDED. CONFIRMED NR 1 FMC, LT, INOPERATIVE. CDU SCREENS BLANK W/ L FMC OVERHEAD SW SELECTED AND FMC, INOPERATIVE
Back to Boeing 737-990ER