SDR WRNA200800007Connector · dirtyAFTER TAKEOFF FROM MIA, NR 1 PACK INOP, UNABLE TO MAINTAIN PRESSURIZATION WITH NR 3 PACK. RETURNED TO FIELD FOR A SAFE LANDING. WHILE TROUBLESHOOTING, FOUND CONNECTOR FOR NR 1 PACK DIRTY, CLEANED AND REINSTALLED CONNECTOR IAW 747 MM 21-51-01 PAGE 401. OPS CSDR WRNA20060031Fire Loop · malfunctionedAFTER LANDING, ON TAXI IN, RECEIVED A FIRE WARNING FOR NR 4 ENGINE, A/C WAS STOPPED, ENGINE WAS SHUT DOWN AND FIRE HANDLE WAS PULLED. INDICATIONS OF FIRE CONTINUED, THE RIGHT ENGINE FIRE BOTTLE SWITCH WAS PUSHED , NO INDICATION OF DISCHARGE, THE LEFT FIRE BOTSDR WRNA200600017Diaphragm · failedAFTER TAKE OFF RUDDER RATIO LIGHT ILLUMINATED ABOVE 210 KNOTS, EXTINGUISHED BELOW 210 KNOTS RETURNED TO FIELD, A SAFE LANDING WAS MADE. FOUND PITOT LEAK IN LOWER RIGHT AUX PITOT SYSTEM CAUSED BY FAILED DIAPHRAGM IN RIGHT STABILIZER MODULE CONTROL PACKAGE, REPSDR WRNA200600018Engine · malfunctionedDURING TAKEOFF, A BALL OF FIRE FROM THE LEFT SIDE WAS REPORTED ACCOMPANIED WITH A LOUD BANG, CREW BELIEVED NR 1 ENGINE HAD FAILED AND ABORT OF TAKEOFF WAS INITIATED. AIRCRAFT SKIDDED APPROX 150 FEET OFF END OF RUNWAY, (RUNWAY CONTAMINATED WITH STANDING WATER)SDR WRNA200600014Static Line · brokenRUDDER RATIO LIGHT CAME ON IN CLIMB, .84M SPEED 300K ALT 32,000. STAYED -ON- CRUISE 39,000 AT 261K, UPPER RUDDER 2 DEGREES LEFT, LOWER RUDDER 0 DEGREES, LIGHT WENT OUT AT 24,000 AT 300K. RETURNED TO MIA AND MADE A SAFE LANDING. RIGGED UPPER AND LOWER RUDDERSDR 200600296Slide · no testUPPER DECK CREW ESCAPE SLIDE RELEASED BUT SLIDE DID NOT DEPLOY DURING MAINTENANCE WHEN TRYING TO SHUT DOOR.SDR 200600293Bulkhead · corrodedBS 1480 FWD BULKHEAD WEB, LBL 36-42, LBL 51.5 AND RBL, 24.75, CORROSION - REPAIR. THIS ECRA PROVIDES INSTRUCTIONS TO REMOVE CORROSION, HFEC INSPECT TO VERIFY ALL DAMAGE IS REMOVED, SPOTFACE THE FASTENER LOCATIONS FOR PROPER SEATING OF THE FASTENERS, AND TO OVSDR 200600294Frame · corrodedBS 2360 BULKHEAD LOWER AFT CHORD CORROSION. THIS PROVIDES INSTRUCTIONS TO REPAIR THE BS 2360 BULKHEAD LOWER AFT CHORD BY REMOVING THE CORROSION, TRIMMING OUT THE TOOLING MARK, HFEC INSPECTING TO CONFIRM CORROSION AND CRACK FREE, INSTALL REPAIR STRAPS TO RESTOSDR WRNA200600005Filter · unknownWHEN LEVELING FL 380, MACH SPD .84, WHILE SLOWLY REDUCING POWER, NR 1 ENGINE AUDIBLY COMPRESSOR STALLED, EPR FLUX ALONG WITH INCREASE IN EGT, AMBER/HIGH EGT LIGHT ILLUMINATED, UPON REDUCING NR 1 ENG TO IDLE, EPR CONTINUED TO FLUX, ACCOMPLISHED ENGINE FAILURE/PSDR WRNA20050029Engine · malfunctionedCLIMBING OUT THRU 16K FT, NR 2 ENGINE SHUTTERED, ACCOMPANIED BY LOUD NOISE. HIGH EGT, EPR AND OIL PRESSURE, TEMP ALL WITHIN LIMITS. SHUT DOWN NR 2 ENGINE. AIRCRAFT RETURNED TO FIELD, LANDING NORMAL.SDR WRNA200500018Line · unserviceableT/O FROM TPE, LANDING GEAR HANDLE WOULD NOT MOVE TO UP POSITION. AIRCRAFT RETURNED TO BASE, LANDING NORMAL. FOUND HYDRAULIC LINE TO TRUCK POSITION ACTUATOR LEAKING (BLOWN). REMOVED AND REPLACED LINE IAW 32-13-05, OP'S CHECK SATISFACTORY, NO LEAKS NOTED. A/SDR WRNA200500016Engine · damagedVERY LOUD RUMBLE ON TAKE OFF. UPON LANDING, NR 2 ENGINE WAS FOUND TO HAVE COILS MISSING FROM LT SIDE. RT SIDE DAMAGED, ALONG WITH VARIOUS OTHER AREAS OF DAMAGE TO DUCT WORK, FIRE SEAL, AND HYD RACEWAY. ALL ITEMS WERE REPAIRED/REPLACED IAW MM 72-11-02,75-24-SDR WRNA200500013Engine · damagedNR1 ENGINE COMPRESSOR STALLED AT FL 11.5, AIRCRAFT RETURNED. LANDING NORMAL. ENGINE BOROSCOPE COMPLIED WITH, NO DISCREPANCIES NOTED. NR 1 ENGINE FAN CASING ACOUSTIC LINERS FROM 1O`CLOCK TO 8 O'CLOCK POSITION DAMAGED. REMOVED AND REPLACED PANELS IAW 72-31-08, SDR WRNA200500012Actuator · unserviceableRUDDER RATIO LIGHT ILLUMINATED WHILE ACCELERATING TO 230KTS IND. AIRCRAFT RETURNED TO AIRFIELD. LANDING NORMAL. REMOVED AND REPLACED LOWER RUDDER LINEAR ACTUATOR IAW 27-21-12. FUNCTIONAL CHECK SATISFACTORY, AIRCRAFT RETURNED TO SERVICE.SDR P5CA0401032Pushrod · shearedMAIN DECK CARGO DOOR FWD HOOK SHAFT PUSH ROD SHEARED ON OPEN SEQUENCE. INSTALLED FWD HOOK SHAFT PUSH ROD, OPS NORMAL IAW 52-32-11.SDR P5CA0401019Duct · leakingBLEED AIR LEAK, APU SUPPLY DUCT AFT OF BULK CARGO COMPARTMENT. ITEM TRANSFERRED TO DMI 32017 AND MEL 49-01-01 PER DDPG.SDR P5CA0401017Pushrod · brokenSIDE CARGO DOOR FAILS TO OPEN. FOUND PUSH ROD BROKEN HOOK ACTUATOR FWD SIDE. REMOVED AND REPLACED ROD AS PER MM 52-32-00, OPS CHECK, OPERATION CHECK NORMAL.SDR P5CA0301016Skin · damagedMAIN DECK CRG DOOR FAILED TO CLOSE - DOOR SKIN DAMAGED. PERFORMED TIME LIMITED REPAIR TO DOOR IAW SL TLS-JFK 03-00243H AND SRM COI WAS ISSED AND DOOR DEFERRED ELECTRICALLY IAW DDPG.SDR P5CA0301010Fcu · failedNR 3 ENG WOULD NOT START, NO FUEL FLOW. CHECKED FUEL CONDITION MOTOR OPS NRML S/OFF VALVE ON FRONT SPAR CHECKED NORMAL. PERFORMED FUEL PUMP PRESS TEST ON FP 12 PORT, CHECKED GOOD. BLED FUEL LINES ON FUEL CONTROL UNIT, ENGINE RAN UP OK 71-00-00.SDR P5CA0301008Valve · failedNR 1 ENG FUEL HEAT FAILED IN OPEN POS WITH ICING LIGHT ON, FUEL TEMP MAX. PER FIM 73-01-00 PG 203 FOUND ZERO VOLTAGE AT SOCKETS BAND ON FUEL HEAT VLV CONNECTOR. REMOVED AND REPLACED FUEL HEAT VLV IAW MM 73-14-01, OPS NORMAL ON ENG RUN.SDR P5CA0301009Rod · defectiveSIDE CARGO DOOR FAILS TO CLOSE. REPLACED INPUT ROD TO FWD HOOK TORQUE TUBE IAW 52-32-11.SDR P5CA0301007Control Unit · malfunctionedAFTER T/O - INBOARD TRAILING EDGE FLAPS HUNG AT 5 DEGREES RETRACTED BY ALTS SYS ON EXTENSION I/B FLAPS HUNG AT 5 DEGREES EXTENDED BY ALT SYS. REPLACED NO COAST DRAG BRAKE PER MM 27-51-42, OP'S CK GOOD.SDR P5CA0300991Engine · failedNR 2 ENGINE FAILED IN FLT LOUD RUMBLE FOLLOWED BY LOSS OF POWER HIGH EGT VIBRATION OIL LOSS. REPLACED NR 2 ENG PER MM 71-00-002.SDR P5CA0300986Indicator · failedON ENGINE START NR 2 INDICATED NO OIL PRESS ON F/E PANEL OR FORWARD PANEL. REPLACED NR 2 ENGINE OIL PRESS INDICATOR SYSTEM CHECKS GOOD IAW MM 79-30-00.SDR P5CA0300977Frame · damagedMAIN DECK CARGO AREA, FUSELAGE FRAME, STA 1700 RT SIDE S-1 TO S-11 FRAME DAMAGE. REMOVED DAMAGED PORTION OF FRAME SECTION. REPAIR ACCOMPLISHED IAW SRM 53-10-04.SDR P5CA0300966Indicator · fluctuatesFIRST OFFICER'S BARBER POLE IN AIRSPEED INDICATOR FLUCTUATES, CAUSING MACH WARNING TO GO OFF. REPLACED A/S INDICATOR.SDR P5CA0300967Csd · malfunctionedON TAXI, NOTED NR 2 & 4 GENERATOR SHOWED NO KW'S AND NO VOLTAGE FREQUENCY. ALSO, NR 3 CSD LIGHT ON FLIGHT ENGINEER'S PANEL - READ ANNUNCIATOR. SERVICED NR 2 & 4 CSD'S. RAN ENGINES AND DISCONNECTED NR 2 & 4 CSD'S. RECONNECTED NR 2 & 4 CSD'S. RE-RACKED GCU SDR P5CA0300959Rib · dentedLT HORIZONTAL STABILIZER RIB CRACKED STABILIZER L/E STA 285 - 4 INCH CRACK. REMOVED LT HORIZONTAL STABILIZER DUE TO FOUND DENTED & REPAIRED RIB (4 INCH CRACK) AT LEADING EDGE STA 285.SDR P5CA0300951Control Quadrant · faultyRUDDER RADIO LIGHT CAME ON WHEN FLAPS MOVING 5 TO 1 AT 220KNTS. REMOVED AND REPLACED RUDDER UPPER CONTROL IAW 27-21-13 LEAK CHECK GOOD.SDR P5CA0300956Skin · crackedRT OUTBOARD MID FLAP COVE PNL DELAMINATED / CRACKED - 24 INCH LONG - WBL 660. REPAIRED DAMAGE AREASDR P5CA0300955Push-Pull Cable · failedNR 4 ENGINE THROTTLE BINDED NR 4 ENG FUEL CONDITION MOTOR POPPED C/B. REPLACED ENGINE PUSH PULL CABLE IAW MM 76-11-07 OPS CK OK. REPAIRED WIRE IAW STANDARD PRACTICES 20-00-00. OPS CK OK IAW AMM 76-11-00SDR P5CA0300953Actuator · defectiveRUDDER RATIO LIGHT CAME ON AFTER FLAPS UP. REPLACED LOWER RUDDER RATIO CHANGER ACTUATOR IAW MM 27-21-12SDR P5CA0300952Actuator · defectiveRUDDER RATIO LIGHT CAME ON AFTER FLAPS UP. REPLACED UPPER RUDDER RATIO CHANGER ACTUATOR AND ADJUSTED UPPER RUDDER IAW MM 27-21-12 AND 27-21-00.SDR P5CA0300939Wire · damagedRT WING LEADING EDGE OVERHEAT LIGHT ON WITH SMALL INCREASE OF PWR. FOUND DAMAGED WIRE AT SWITCH 1046 REPAIRED WIRE PER 20-50-2.SDR P5CA0300940Connector · disconnectedAFT 20 MINUTES INTO CRUISE RT WING L/E OVERHEAT LIGHT ILLUMINATED. REMAINED ON UNTIL BLOCK IN. FOUND NR 3 PYLON DETECTOR S1046 SHORTED. DISCONNECTED S1046. ITEM DEFERRED PER MEL 26-22-03A. SECOND LOOP OPS NRML PER MM 26-15-00SDR P5CA0300938Duct · looseRT WING L/E OVERHEAT LIGHT CAME ON TAXI OUT. REMAINED ON WHEN ISOLATED. FOUND LOOSE DUCT LEADING TO NR 3 LEADING EDGE FLAP MOTOR. TIGHTENED AS REQUIRED SYS LEAK CK GOOD IAW MM 27-81-00 PG 207.SDR P5CA0300933Pump · leakingLOSS HYD FLUID NR 4 SYS. NR 4 EDP REMOVED AND DEACTIVATED INSTALLED DEACTIVATION KIT IAW MEL 29-01-A TRASFERRED TO DMI 31340.SDR P5CA0300924Hydraulic Line · rupturedNR 1 HYDRAULIC SYS QUANITITY AND PRESSURE DROPPED TO ZERO AT STARTUP. SWAPPED PRESSURE LINE FROM NR 2 TO NR 1. CAPPED NR 2 ADP LINE FITTINGS. PERFORMED LEAK CHECKS, OPERATIONAL CHECK PER 29-11-00. SYS OPERATIONAL CHECK AND LEAK CHECK NORMAL.SDR P5CA0300925Compressor · stalledENGINE COMPRESSOR STALL ON DESCENT. REMOVED AND REPLACED NR 3 ENG, REF PAC ENG CHANGE WORK CARDS 7100-002.SDR P5CA03000915Fuel Control · overheatedON DESCENT INTO HKG AT FL 360 NR 3 ENG FUEL TEMP WENT OFF SCALE HOT AND NR 3 ENG STALLED OUT. CORRECTIVE ACTION TAKEN: REPLACED NR 3 ENG FUEL CNTRL IAW AMM 73-21-01 LEAK CK OK PERFORMED TEST NR 9 FUEL CONTROL TRIM OK IAW 71-00-00 PG 580.SDR P5CA03000316Compressor · stalledNR 3 ENG COMPRESSOR STALLED AT FL 330 FUEL TEMP PEGGED AT OFF SCALE HOT AND OIL TEMP WENT TO 150 DRGS. PREFORMED 8TH STAGE BLEED CHECK VALVE. CHECKED P/R LINE ON T12 SENSOR, CHECKED FUEL HEAT VALVE, CHECKED NR 3 MAIN TANK SUMP DRAIN CHECKED FUEL / OIL COOLER SDR P5CA0300914Valve · malfunctionedPRIOR TO DESCENT APPLIED FUEL HEAT TO NR 3 ENG, FUEL HEAT DID COME DOWN AND PEGGED HOT ENG STALL ON DESCENT. PERFORMED A PRECAUTIONARY ENG SHUT DOWN AT 1600 FT ACCORDING TO PROCEDURE.SDR P5CA0300911Engine · power lossNR 3 ENG STALL CONDITION AFTER DESCENT FROM FL 330. PERFORMED FULL NR 3 ENG INSP. SUMPED ALL FUEL TANKS. CHECKED AND INSPECTED EVBC SCREEN. CHECKED FCU LINES FOR SECURITY AND NO LEAKAGE. PERFORMED ENG RUN ALL PARAMETERS IND NORMAL TO, OK TO CONTINUE SRVC. IAWSDR P5CA0300910Filter · contaminatedON DECENT NR 3 ENG HAD STALLED CONDITION. AT FL 290 SHUT DOWN. ON SECOND RESTART WITH FUEL HEAT APPLIED OPERATION NORMAL. CORRECTIVE ACTION TAKEN: REMOVED FUEL FILTER. INSPECTED AND CLEANED WATER FROM FILTER. REINSTALLED FILTER PERFORMED AURAL CK OF FUEL HEATSDR P5CA0300906Cdu · malfunctionedNR 1 INS DISPLAY WENT BLANK AFTER PUSH BACK WARNING LIGHT CAME ON AND ADI TUMBLED. SWAPPED NR 1 CDU AND NR 3 CDU OPERATIONAL CHECK NORMAL PER MM 34-41-02.SDR P5CA0300894Connector · dirtyNR 2 ENG WILL NOT START. NO FUEL FLOW. NR 2 ENG FUEL CONDITION ACTUATOR PLUG CLEANED AND RESECURED. ACTUATOR EXERCISED. ENG START SATIS. SUSPECT WIRING TO FUEL CONDITION ACTUATOR.SDR P5CA0300895Actuator · malfunctionedNR 2 ENGINE FAILED TO START (NO FUEL) AFTER SECOND ATTEMPT. PRESSURE CHECKED FUEL PUMP IAW MM 71-00-00. REMOVED FUEL CONDITION ACTUATOR CHECKED SHAFT. REINSTALLED FUEL CONDITION ACTUATOR ENG RUN/ OPS CKSDR P5CA0300896Coupling · shearedNR N2 INDICATION ON NR 3 ENGINE, DURING START - ENGINE DID NOT START PYLON AND START VALVE LIGHTS SHOW AIR PRESS TO STARTER BUT NO ROTATION. REMOVED AND REPLACED PNUEMATIC STARTER ALSO COUPLING WAS SHEARED.SDR P5CA03000885Warning Light · illuminatedON T/O NR 4 ENG FIRE DET A-LOOP ILLUMINATED FIRE LIGHT. B-LOOP NORMAL. ITEM WAS DEFERRED PER THE DDPG AFTER IT WAS DETERMINED THAT ONE LOOP WAS OPERATIONAL. DEFECTIVE A-LOOP.SDR P5CA0300884Clamp · looseBOTH A&B NR 2 NACELLE TEMP SPIKING RETARDED THROTTLE NACELLE INDICATIONS NORMAL. ON LEAK CK FOUND FAILED DUCT CLAMP BETWEEN HEAT EXCHANGER & ENG DUCT. INSTALLED NEW CLAMP AND ON LEAK CHECK NIL LEAKS NOTED. THREADS STRIPPED ON HOLDING BOLT FOR CLAMP.
Back to Boeing 747-2U3B