SDR UIEA2014040300137Pdu · malfunctionedSTEERABLE PDU AT 5R FAILED DURING NOSE LOADING, CAUSED STRONG ELEC SCENT IN UPPER DECK & FLIGHT DECK AFTER FAILURE, UPON INSPECTION FOUND BREAKER OPEN. NOTIFIED MCC OF ISSUE & SCENT DEFERRED PDU IAW MEL 25-53-01. BREAKER OPENED & RAISED MDDR 4732.SDR UIEA2014032000120Support · corrodedCORROSION ANGLE, STATION 1287 KEEL BEAM LOWER SUPPORT. FABRICATE NEW PART IAW EI NO T2014P53B-758 REV 0. REPLACED NEW PART IAW SRM 51-40-02 REV 69.SDR UIEA2014032000119Support · corrodedCORROSION ANGLE, STATION 1449 KEEL BEAM LOWER SUPPORT. FABRICATE NEW PART IAW EI NO T2014P53B-762 REV 0. REPLACED NEW PART IAW SRM 51-40-02 REV 69.SDR UIEA2014032000118Support · corrodedCORROSION ANGLE, STATION 1427 KEEL BEAM LOWER SUPPORT. FABRICATE NEW PART IAW EI NO T2014P53B-762 REV 0. REPLACED NEW PART IAW SRM 51-40-02 REV 69.SDR UIEA2014032000117Seat Track · crackedCRACK ON THE MAIN DECK CARGO SEAT TRACK BETWEEN STATION 980 & 1000, RBL 75.92. REPAIR SEAT TRACK IAW SRM 53-00-52-2R-13 REV 69.SDR UIEA2014032000116Seat Track · crackedCRACK ON THE MAIN DECK CARGO SEAT TRACK BETWEEN STATION 980 & 1000, RBL 75.92. REPAIR SEAT TRACK IAW SRM 53-00-52-2R-13 REV 69.SDR UIEA2014032000115Plate · corrodedCORROSION PLATE AT RT WING LE LOWER SIDE, OLES 1545.5. REPLACED DAMAGED PART IAW SRM 51-40-02-06-0 REV 68.SDR UIEA2014032000122Support · corrodedCORROSION ANGLE, STATION 1308 & STATION 1314, KEEL BEAM LOWER SUPPORT. TTL = 2 EACH, FABRICATE NEW PART IAW EI NO T2014P53B-758 REV 0. REPLACED NEW PART IAW SRM 51-40-02 REV 69.SDR UIEA2014032000121Support · corrodedCORROSION ANGLE, STATION 1405 KEEL BEAM LOWER SUPPORT. FABRICATE NEW PART IAW EI NO T2014P53B-758 REV 0. REPLACED NEW PART IAW SRM 51-40-02 REV 69.SDR UIEA2014031700110Mount Fitting · crackedNR 2 ENG LT THRUST REVERSER COWL FWD BULKHEAD LOWER THRUST REVERSER ACTUATOR MOUNTING FITTING FOUND CRACKED. CRACK AREA REPAIRED IAW CMM 78-32-02 REPAIR 016.SDR UIEA2014031700109Intercostal · crackedMAIN DECK STATION 1220 LBL 97 TO LBL 127 BELOW FLOOR INTERCOSTAL WEB FOUND CRACK AT LBL 105" APPROX. REPAIRED CARRIED OUT IAW SRM-53-40-51-2R-5 REPAIR 5.SDR UIEA2014031700108Intercostal · crackedMAIN DECK STATION 1220, RBL 97 TO RBL 127 BELOW FLOOR INTERCOSTAL WEB FOUND CRACK AT RBL 105" APPROX. REPAIRED CARRIED OUT IAW SRM-53-40-51-2R-5 REPAIR 5.SDR UIEA2014031700107Intercostal · crackedMAIN DECK RT, STATION 1200 BELOW FLOOR INTERCOSTAL WEB ASSEMBLY RBL 98 TO RBL 128 FOUND CRACK AT RBL 105" APPROX. REPLACED THE CRACKED INTERCOSTAL WEB ASSEMBLY IAW R1-53-41-10480.SDR UIEA2014031700106Intercostal · crackedMAIN DECK RT BS 1180 BELOW FLOOR INTERCOSTAL WEB ASSEMBLY RBL 98 TO 128 FOUND CRACK AT RBL 105" APPROX. REPLACED THE CRACKED INTERCOSTAL WEB ASSEMBLY R1-53-41-10481.SDR UIEA2014031800111Reveal · crackedREVEAL PANEL CRACK AT CABIN BS 2240 STRINGER 25L L5 ENTRY DR FWD LWR CUT OUT. REVEAL CRACK AREA REPAIRED IAW RI NO RI-53-61-10488 REV C.SDR UIEA2014022700086Intercostal · crackedCABIN STATION 1180, LBL 98 - 127 FLOOR INTERCOSTAL WEB FOUND CRACKED. R & R CABIN STATION 1180, LBL 98 - 127 FLOOR INTERCOSTAL WEB IAW R1-53-41-10463.SDR UIEA2014022700087Intercostal · crackedCABIN STATION 1200, RBL 98 - 127 FLOOR INTERCOSTAL WEB FOUND CRACKED. R & R CABIN STATION 1200, RBL 98 - 127 FLOOR INTERCOSTAL WEB IAW R1-53-41-10462.SDR UIEA2014022400081Safety Valve · faultyREF SDR UIEA2014022400080. AT FL 320, SPEED .834 EICAS MESSAGE, GEAR DOOR, RUMBLE WAS FELT. QRH 14.16 COMPLIED WITH. GEAR HANDLE PLACED IN UP POSITION. REPLACED SAFETY VLV IAW AMM 32-33-29-404-006.SDR UIEA2014022400080Actuator · malfunctionedAT FL320 SPEED .834 EICAS MESSAGE, GEAR DOOR, & RUMBLE WAS FELT. QRH 14.16 COMPLIED WITH. GEAR HANDLE PLACED IN UP POSITION. RT BODY GEAR DOOR ACTUATOR REPLACED IAW AMM 32-33-27-404-006.SDR UIEA2014021000046Intercostal · crackedMAIN DECK STATION 1180 RBL 98 - 108 BELOW FLOOR, INTERCOSTAL FOUND CRACK. INTERCOSTAL REPLACED IAW R1-53-41-10445.SDR UIEA2014021000047Intercostal · crackedMAIN DECK STATION 1200, RBL 98 - 108 BELOW FLOOR, INTERCOSTAL FOUND CRACK. INTERCOSTAL REPLACED IAW R1-53-41-10446.SDR UIEA2014021000048Intercostal · crackedMAIN DECK STATION 1200, LBL 98 - 108 BELOW FLOOR INTERCOSTAL FOUND CRACK. INTERCOSTAL REPLACED IAW R1-53-41-10446.SDR UIEA2014021000049Intercostal · crackedMAIN DECK STATION 1180, LBL 98 - 108 BELOW FLOOR, INTERCOSTAL FOUND CRACK. INTERCOSTAL REPLACED IAW R1-53-41-10445.SDR UIEA2014021000050Skin · crackedFX EXTERNAL SKIN STATION 1718, STRINGER 41L FOUND CORROSION CRACK. SKIN REPAIR CARRIED OUT IAW SRM 53-00-01 REPAIR 1.SDR UIEA2014021000051Skin · crackedFX EXTERNAL SKIN STATION 1715, STRINGER 45L FOUND CORROSION CRACK. SKIN REPAIR CARRIED OUT IAW SRM 53-00-01 REPAIR 1.SDR UIEA2014012800040Unknown · smokeDURING REVERSE THRUST ON LANDING, SMOKE IN CREW REST AREA, ADVISORY EICAS MESSAGE APPEARED WITH VISIBLE SMOKE & ODOR IN CREW REST AREA. COMPLIED WITH CONDITIONAL INSPECTION IAW AMM 05-51-56, TASK 05-51-56-200-801, SMOKE OR FUMES IN CABIN. NO DEFECTS NOTED.SDR UIEA2014012400033Intercostal · crackedMAIN DECK STATION 1220 LBL 100 INCHES BELOW FLOOR INTERCOSTAL FOUND CRACK. REPAIRED CARRIED OUT IAW SRM 53-40-51 REPAIR 5.SDR UIEA2014012400034Intercostal · crackedMAIN DECK STATION 1180 RBL 100 INCHES BELOW FLOOR INTERCOSTAL FOUND CRACKED. INTERCOSTAL REPLACED IAW R1-53-41-10436.SDR UIEA2014012400032Intercostal · crackedMAIN DECK STATION 1180 LBL 100 INCHES BELOW FLOOR INTERCOSTAL FOUND CRACKED. INTERCOSTAL REPLACED IAW R1-53-41-10436.SDR UIEA2014012300030Intercostal · crackedMAIN DECK STATION 1200 RBL 105'' BELOW FLOOR INTERCOSTAL FOUND CRACKED. INTERCOSTAL REPLACED IAW R1-53-41-10434.SDR UIEA2014012300029Spar · damagedLEFT W OTBD FORE FLAP FRONT SPAR LOWER FLANGE ONE EACH FASTENER HOLE FOUND ELONGATED APPROXIMATELY 128 INCHES FROM ON BOARD & EDGE. REPAIRED CARRIED OUT IAW R1-57-58-10433.SDR UIEA2014012300026Skin · crackedFX BS 980, STRINGER 38R SKIN, ONE EACH FASTENER HOLE FOUND CRACKED AT 6 O`CLOCK POSITION. SKIN REPAIRED CARRIED OUT IAW SRM 53-20-01 REPAIR 2.SDR UIEA2014012200022Skin · crackedFX BS 980, STRINGER 38L SKIN, ONE EACH FASTENER HOLE FOUND CRACKED. SKIN REPAIRED CARRIED OUT IAW SRM 53-20-01 REPAIR 2.SDR UIEA2014012200020Floorbeam · corrodedMAIN DECK BS 2240, RBL 55-58 FLOOR BEAM FOUND CORROSION. FLOOR BEAM UPPER CHORD REPAIR CARRIED OUT IAW SRM 53-00-51 REPAIR 3.SDR UIEA2014012100016Transmitter · faultyAIR TURN BACK AT 3,000', DURING INITIAL FLAP RETRACTION, FLAPS DRIVE EICAS MESSAGE. DUMPED FUEL TO MAX LANDING WEIGHT & NORMAL TOUCHDOWN. REPLACED LT INBD FLAP POSITION TRANSMITTER & NBSP IAW AMM 27-58-01/401. OPERATIONS CHECKED GOOD IAW AMM 27-58-01 501.SDR UIEA2014010900004Light · inoperativeL1 DOOR OVERHEAD EMERGENCY LIGHT FOUND INOPERATIVE. L1 DOOR OVERHEAD EMERGENCY LIGHT LAMP REPLACED & OPERATIONS TESTED NORMAL IAW AMM 33-51-05.SDR UIEA2014010900005Light · inoperativeNBSP MD OVERHEAD EMERGENCY LIGHT FOUND INOPERATIVE. MD OVERHEAD EMERGENCY LIGHT LAMP REPLACED & OPERATIONS TESTED NORMAL IAW AMM 33-51-07.SDR UIEA2013122200612Structure · damagedDAMAGE WAS FOUND NEAR TAIL JACK AREA AT BS 2594, ABOVE STRINGER 42R. DAMAGE WAS FOUND TO BE BEYOND THE LIMITS OF SRM 53-00-01, FIG 101 ALLOWABLE DAMAGE. EO 4453A930, FAA 8110-320 DEC13 & NBSP PART 1 ALLOWS FOR A TIME LIMITED REPAIR & NBSP IAW & NBSP SRM 53-80SDR UIEA2013121300598Hmu · faultyNUMBER 1 ENG PRECAUTIONARY SHUTDOWN. BY MCC REQUEST PERFORMED WIND WILL INSPECTION IAW MM 72-00-00-206-0059-J00, NO FAULTS NOTED AT THIS TIME. ECM 2013P-148 ASSIGNED WHICH INCLUDED BORE SCOPE INSPECTIONS & HMU REPLACEMENT THESE ITEMS WERE WORKED ON LP 540652SDR UIEA2013121200597Flap · damagedRIGHT OTBD FORE FLAP HAD A BIRD STRIKE. REPLACED RT OTBD FORE FLAP IAW B747-400 AMM 27-51-04 401.SDR UIEA2013121300600Pdu · malfunctionedSMOKE IN MAIN CARGO DECK DURING LOADING. SOURCE OF SMOKE FOUND TO BE FROM PDU 14L. PDU 14L DEACTIVATED & DEFERRED IAW DDG 25-53-01C. PERFORMED INSPECTION IAW 05-51-56, NO FURTHER DISCREPANCIES NOTED.SDR UIEA2013121000591Pdu · malfunctionedSMOKE IN MAIN CARGO DECK DURING LOADING. SOURCE OF SMOKE FOUND TO BE FROM PDU 14L. SEE LP 468640 ITEM 1M FOR DEFERRAL. PERFORMED INCP 05-51-56, SMOKE ON FUMES IN CABIN. NO FURTHER DISCREPANCIES NOTED.SDR UIEA2013121000590Warning System · activatedNUMBER 1 ENG PRECAUTIONARY SHUT DOWN, ENG 1 CONTROL STATUS MESSAGE. WINDMILL INSPECTION COMPLIED WITH, NO DEFECTS NOTED. TROUBLESHOT CONTROL STATUS MESSAGE, NOTHING FOUND. ENG RUN PERFORMED, ENG CONTROL MESSAGE RETURNED, ABNORMAL PARAMETERS FOUND. TROUBLESSDR UIEA2013112200566Hmu · malfunctionedDURING LT TURN INTO PARKING ADDED POWER FOR TURN, NR 4 ENG NO RESPONSE. R & R 4 ENGINE HMU IAW MM 72-21-14. RAN ENGINE AND PERFORMED MM 71-00-00 TEST 3, 12 AND 2 ENGINE RESPONSE NORMAL.SDR UIEA2013111900561Pdu · failedAIR TURN BACK DUE TO FLAPS PRIMARY EICAS MESSAGE AFTER TAKEOFF; APPROXIMATELY AT 10,000 FT, AFTER SELECTING FLAPS "UP". ALT FLAPS DISPLAY HAD AN "X" FOR RIGHT MIDSPAN L/E. R & R R3 L/E DRIVE PDU IAW AMM 27-81-03, ALL OPS NORMAL.SDR UIEA2013111900564Fuel Cell · contaminatedENG 2 FUEL FILTER EICAS MESSAGE APPEARED AND DURING LT TURN INTO PARKING THERE WAS NO REPSONSE FROM ENGINE 4 WHEN POWER DEMANDED. FOUND FUEL CONTAMINATED IN ALL FUEL TANKS. CLEANING OF FUEL TANKS CURRENTLY IN PROGRESS. ALL ENGINE FUEL FILTERS AND APU FUEL FISDR UIEA2013111100557Flap · damagedLEFT OTBD FORE FLAP UPPER SURFACE OF L/E HAS BIRD STRIKE DAMAGE. TAP TEST SHOWS DAMAGE TO BE WITHIN AN AREA OF 18" LONG BY 8" WIDE. APPLIED TIME LIMITED REPAIR IAW EO 4457A472, PART 1.SDR UIEA2013110700555Warning Message · false activationREJECTED TAKEOFF. "AUTH THL DISC" MESSAGE AFTER PUSHING TO/GO, NOTICED NO N1 INDICATION ON FMA, FMC-L FAIL. CHAPTER 5 HIGH ENERGY STOP CONDITION CARRIED OUT IAW MM 5-51-10, NO DEFECTS FOUND.SDR UIEA2013100800512Oven · smokeOVEN STARTED SMOKING DURING USE. DISCONTINUED AND BREAKERS PULLED.SDR UIEA2013093000510Floor Support · crackedFLOOR SUPPORT CRACKED BS 1000, LBL 75.92. REPAIRED CRACK DAMAGE IAW SRM 53-00-52-2R-13, REPAIR 13.
Back to Boeing 747-47UF