Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012122807436Door Seal · obstructedDOOR 1L HAS SILICONE AND TRIM ENCROACHING INTO DOOR SEAL AREA AT FORWARD FRAME. REMOVED MATERIAL AND CLEANED SEAL AREA.SDR UALA2012122807435Door Seal · obstructedDOOR 4R HAS SEALANT ENCROACHING INTO SEAL MATING AREA AT FWD FRAME. REMOVED MATERIAL AND CLEANED SEAL BEARING AREA.SDR UALA2012122807434Door Seal · obstructedDOOR 4L HAS SEALANT ENCROACHING INTO SEAL MATING AREA AT FWD FRAME. REMOVED AND CLEANED SEAL AREA.SDR UALA2012122807433Door Seal · obstructedDOOR 2R HAS SEALANT ENCROACHING INTO SEALING AREA AT FWD FRAME. REMOVED AND CLEANED SEAL BEARING AREA.SDR UALA2012122807432Door Seal · obstructedDOOR 2L HAS SEALANT ENCROACHING INTO SEAL MATING AREA AT FWD FRAME. REMOVED SEALANT AND MATERIAL FROM SEAL AREA.SDR UALA2012122707422Adc · faultyAIRSPEED INDICATOR DISAGREE, FLIGHT DIVERTED. TRIPPED ON LEFT STAB TRIM & ELEV LIMIT MODULE. REPLACED LEFT ADC AND RESET LEFT SAM.SDR UALA2012122707404Apu · failedCABIN FILLED WITH SMOKE WHILE BROADING PASSENGERS. APU CONFIRMED FAILURE. APU PNEUMATIC DUCT FROM APU FWD BULKHEAD TO STA 1743 NEEDS CLEANING DUE TO OIL INSIDE OF DUCT CAUSED BY APU MALFUNCTION. FOUND KEVLAR, MATERIAL (FOD) IN INLET OF OLD APU INLET SCREEN,SDR UALA2012122707428Lanyard · obstructedSLIDE ARMED LIGHT 4R DOES NOT ILLUMINATE WITH DOOR CLOSED AND ARMED. REMOVED SLIDE LANYARD FROM GIRT BAR NOT ALLOWING GIRT TO ARM TO PROX SENSOR, OPS CHECK ARMED DISARMED SLIDE LIGHT ON AND OFF NORMALLY, VERIFIED GIRT BAR POSITIONS AT ARM AND DISARMED, OP CHESDR UALA2012122707429Valve · faultyRIGHT DUCT PRESSURE MINIMAL AT IDLE. RIGHT PACK OFF DUE TO LOW FLOW (CHRONIC) FOUND HS PILOT OVERPRESSURE INDICATOR EXTENDED ON NR 2 ENGINE. T-S REF FIM 36-10-00 PG 155, FIG 111, BLOCKS 1, 21, 42. ACP'D PNEUMATIC HEALTH CHECK ON HPSOV AND HS PILOT, BOTH FAISDR UALA2012122707430Seal · defectiveHIGH PITCH SQUEAL PILOTS WINDOW OCCURED 1 1-2HOUR INTO FLIGHT. MAINT TEXT: REMOVED AND REPLACED SEAL WAITING FOR SEALANT TO CURE. PRESSURIZED HULL TO 4DELTA -P NO LEAKS.SDR UALA2012122707420Girt Bar · obstructedDOOR 4L WILL NOT ARM. REMOVED ICE FROM GIRT BAR AND UPPER DOOR HINGE & APPLIED ICE RELEASE.SDR UALA2012122707416Light · inoperativeRIGHT OVERWING ESCAPE HATCH, AFT HATCH EEL'S INOP. RELAMPED BOTH HATCH EEL RIGHT OVERWING HATCH. P-N 1317.SDR UALA2012122407373Doubler · crackedFOUND DURING ACK,SMC7-MED2L UPPER HINGE LINK STRIKING DOUBLER ON DOOR FRAME HINGE CUTOUT. PART OF THE UPPER HINGE LINK MECHANISM IS STRIKING THE DOUBLER ON THE FWD INSIDE PORTION OF DOOR 2L MARKED WITH AMM, CAUSING A CRACK ABOUT 7-32NDS INTO THE EDGE. DOUBLSDR UALA2012122407372Floor Panel · damagedCARGO PIT FLOOR PANEL CRACKED. DAMAGED AREA NOT ABLE TO RPR. NEED NEW FLOOR PANEL 170-3422. INSTALLED PANEL PER AMM.SDR UALA2012122407371Bottle · low pressureDOOR 2R PAX DOOR EMERGENCY POWER RESERVOIR PRESSURE BELOW LIMITS PER JOB CARD 5-5650-A STEP 7(C). REMOVED AND REPLACED DOOR 2R EMERGENCY PWR RESERVOIR BOTTLE ASSY IAW AMM.SDR UALA2012122407389Acm · faultyWHILE GATE ON APU PNEUMATICS, CCKPI TEMP RAN WAY HOT. UNABLE TO COOL CCKPT W- ENGINE ON PACK. REPLACED LEFT ACM PER MM, OPS CHECKS GOOD.SDR UALA2012122407374Pcu · leakingLEFT OUTBD ELEVATOR PCA LEAKING AT 90 DROPS PER MINUTE AFTER PRESSURIZING RIGHT HYDRAULICS. REMOVED OLD AND INSTALLED NEW UNIT PER 27 31 05. INSTALLATION TORQUE AND PART VERIFICATION COVERED UNDER PTT 8302020.SDR UALA2012122407400Hinge · damagedREPORTED EXTERNAL POWER ACCESS DOOR NOT FAIRED. REMOVED DOOR REF CDL -52L. NEEDS NEW HINGES AND LATCHES ACCOMPLISHED ADJUSTMENT AND RIG OF DOOR AND DOOR HINGE. FIT AND FARE ARCHIVED.SDR UALA2012122107335Light · inoperativeFWD AFT LAV EEL LIGHT INOP. ACCOMPLISH NON-RII INSPECTION OF AMIS ITEM 5522012 :RELAMPED EEL LIGHT AT FWD AFT LAV (PCN 560-3325), OPS CHECK GOOD. INSPECTION COMPLETED. OPS CHECKED GOOD.SDR UALA2012122407377Light · inoperativeDOOR 4L OUTSIDE EMERGENCY LIGHT IS INOP. RELAMPED, OPS OK.SDR UALA2012122107364Oxygen Mask · leakingOXYGEN MASK DEFECTIVE AT2.(1=CAPT,2=1ST OFF,3=1ST OBS) CREW COMMENTS: F/O OXYGEN MASK HARNESS BLOWN, LEAKS. REPLACED F/O OXYGEN MASK.SDR UALA2012122107363Bottle · low pressureAFT O2 BOTTLE WAS USED PRESSURE IS LOW. PRESSURE IS LOW. REMOVED BOTTLE AND INSTALLED STICKER TO BRACKET.SDR UALA2012122107362Threshold · damagedRAMP REPORTED THRESHOLD DAMAGE ON INBD EDGE OF AFT CARGO PIT THRESHOLD PLATE. SUPPLEMENTAL DATA UPDATE, WELDED THRESHOLD.SDR UALA2012122107340Repair · crackedPASSENGER ENTRY-SERVICE DOORS R FWD NOISE FROM AIR LEAK. CREW COMMENTS: HIGH PITCHED SQUEAL IN CLIMB HISSING NOISE IN CRUISE DOOR 1R. FOUND UPPER REN REPAIR CRACK OUT, REPAIRED AND REPRESSURIZE TO 3.5, NO SQUEALING.SDR UALA2012122107330Fitting · out of adjustDOOR 1L HARD TO ARM-DISARM WEDGE DOES NOT POP OUT ADJUSTED AFT GIRT BAR FITTING, WEDGE AND ARM-DISARM OPS CHECKED NORMAL. WITNESSED SLIDE BOTTLE PIN REMOVAL AND STORAGE. WITNESSED DOOR ASSIST BOTTLE PIN REMOVAL. REF AMM 52-11-25 AND RII LST CHAPTER 25 GROUPSDR UALA2012122107320Light · inoperativeDOOR 4R EXTERIOR EMERGENCY LIGHT INOP. REPLACED EMERGENCY EXIT DOOR LIGHT LAMP AT DOOR-4R POSITION, OPS CHECKED NORMAL.SDR UALA2012122107319Light · inoperativeEEL AT RIGHT OVERWING EXIT INOP, FWD HATCH, AFT HATCH LIGHT, AFT HATCH BOTH HATCH LIGHTS. RELAMPED RIGHT OVERWING HATCH LIGHTS OPS CHECKED GOOD PER AMM. (P/N 1317).SDR UALA2012122107318Light · inoperativeEEL INOP IN BULLNOSE PAX SEAT 40D. RELAMPED EEL LIGHT AT 40D, OPS CHECKED GOOD PER AMM 33-51-00, PG 501. P-N 1317.SDR UALA2012122107345Module · faultyRIGHT FLT CONTROL CUTOFF WONT STAY IN. REPLACED RIGHT FLIGHT CONTROL SWITCH MODULE ON P-61 PNL. SWITCH OP'S CHECK GOOD.SDR UALA2012121907293Roller · missingDOOR 1 LEFT ENTRY DOOR UPPER AFT RIGHT ROLLER MISSING. INSTALLED NEW ROLLER DOOR 1L UPPER AFT POS.SDR UALA2012121907292Audio Panel · faultyPA VERY SCRATCHY WHEN TRANSMITTING FROM F/O AUDIO PANEL. REPLACED AUDIO SELECTOR PANEL, OPS CHECK OK.SDR UALA2012122107311Light · inoperativeEMERGENCY LIGHT AT L60 AT DOOR 3R IS INOP, NEED SLIGHT ASSY 564-0419. EMERGENCY LIGHT ASSY AT DOOR 3R PER IPC, OPS CHECK GOOD.SDR UALA2012122107312Socket · faultyEMERGENCY EGRESS LIGHT L563 INOP LOCATED AT AFT RIGHT OVERWING. NEED LIGHT ASSY 564-0044. REPLACED SOCKET ASSY, OPS CHECK GOOD.SDR UALA2012121907287Motor · faultyFIRST OFFICER WINDSHIELD WIPER ONLY MOVES ALONG TOP HALF OF TRAVEL. REPLACED MOTOR PER MM AND WIPER ARM, OPS CHECKED NORMAL.SDR UALA2012121907309Mount · wornSEATS 39 DEF LOOSE FROM FLOOR MOUNTS. THE SEAT RAIL IS WORN AT THE SEAT ATTACHMENT, THE SEAT ASSY HAS BEEN FITTED WITH NEW MOUNTING HARDWARE AND RELOCATED ONE INCREMENT FWD IN THE RAIL PER ECRA 2521-02284. REPAIR OR RE-EVALUATE WITHIN 10 DAYS. ENGINEERING ISDR UALA2012121907282Torque Tube · damagedMED 1L GUST LOCK COLLAR ASSY BROKEN. SPV - FOUND BODY TORQUE TUBE DAMAGED ALONG WITH GUST LOCK. REMOVING DOOR FOR ACCESS TO TUBE. NEED TO REPLACE UPPER HALF, PART HERE IN THE MORNING, H5586 FROM BOEING.SDR UALA2012121907289Light · inoperativeSTAR DEPARTURE CHECK REVEALS OVERWING SLIDE LIGHTS AT 2R, 3R, AND OVERWING AFT ARE INOP ON LIGHT TEST. RELAMPED DOOR 2R EXT EMERGENCY LIGHT, CHECK OK. DOOR 3R HAS POWER & GRD. RELAMPED, NO HELP. NEEDS REFLECTOR SOCKET, OVERWING RT AFT EMERGENCY LIGHT HAS 6SDR UALA2012121907281Light · damagedPER INBOUND FLT CREW NOTE, CABIN FLOOR EEL LIGHT STRIP CAME LOOSE AND CAP IS BROKEN AT SEAT ROW 8. REPAIRED EEL LIGHT STRIP.SDR UALA2012121907288Plate · looseUNBEARABLE OCARINA-LIKE HOWLING NOISE IN VICINITY OF F/O'S FWD INSTRUMENT PANEL & ABV 2.6 FOUND WIPER MOTOR ACCESS PLATE LOOSE. SECURED SCREWS ON PLATE REF AMM. SEALANT CHECKS OK. PRESSURED AC, NO NOISE OR LEAKS NOTED AFTER TIGHTENING PLATE.SDR UALA2012121707261Arm · faultyF/O,S WINDSCREEN WIPER HAS METAL PIECE STICKING UP. REPLACED ARM ASSY PER MM. ADJUSTED AND OPERATIONAL CHECKS GOOD.SDR UALA2012121707262Fastener · missingSCREW MISSING FM PANEL OUTBOARD OF MAIN LANDING GEAR INBD OF CANOE. WASHER IS THERE; SCREW GONE. INSTALLED FASTENER.SDR UALA2012121707258Switch · sticksSWAPPED L ASP WITH 1ST OBSERVERS ASP DUE TO CAPT PTT SWITCH STICKING. REPLACED 1ST OBSERVERS ASP, OPS CHECK GOOD.SDR UALA2012121407251Light · inoperativeEEL LIGHT STRIP AT FWD COAT CLOSET INOP. PERFORM TS ON EEL LIGHT STRIP AT FWD COAT CLOSET OPEN. REPLACE EEL LIGHT STRIP IAW B757 A MM 33-51-11. PERFORM OPS CHECK OF EEL LIGHT STRIP AT FWD COAT CLOSET, OPS CHECK FOUND NORMAL IAW AMM B757 33-51-00.SDR UALA2012121407252Skin · damagedTHE FUSE SKIN REPAIR INSTALLED PER ECRA 5361-01031 BETWEEN BS 1384 - 1401, AND STR 28L -29R RECEIVED FIRST AND SECOND STAGE APPROVAL. MAJOR REPAIR ACCOMPLISHED: DOUBLER INSTALLED OVER EXISTING HOLE AT STA 1393, STR 30.SDR UALA2012121407239Light · inoperativeEEL AT AFT LAV IS IN-OP. REPLACED EEL STRIP.SDR UALA2012121407235Bracket · corrodedEXFOLIATION-CORROSION UNDERNEATH STIFFENING BRACKET. INSIDE APU INLET PLENUM ABOVE AFT CTR SUPPORT CASTING FOR ENGINE MOUNT (POPPED RIVET HEAD "MARKED"). CLEANED CORROSION AND REPAIRED STIFFENING BRACKET REF SRM.SDR UALA2012121407236Oven · contaminatedBURNED PLASTIC SMELL IS EMANATING FROM FORWARD GALLEY OVENS. REMOVED BURNT PLASTIC MATERIAL FROM OVEN, RAN OVEN 12 MINS, OPS CHECK NORMAL.SDR UALA2012121407246Support Beam · corrodedSTA 1661 TO 1681 BL 0 SUPPORT P/N 146N5650-1 CORRODED. REMOVED AND REPLACED SUPPORT BEAM IAW SRM.SDR UALA2012121407227Floorbeam · corrodedAFT CABIN STA 1640 FLOORBEAM UPPER CAP CORRODED RBL 58 .22 TO BL 0. UPPER CHORD REPAIR ACCOMPLISHED PER ECRA 5310-05634.SDR UALA2012121407241Unknown · leakingBLUE WATER LEAKING FROM WEEP HOLE UNDER AFT PIT. AFT PIT PANELS WAS OPENED BY PREVIOUS SHIFT, DID NOT FIND ANY SOLID EVIDENCE OF BLUE WATER LEAK (WITH THE DUMP VALVES OPENED, HAD LAV SERVICE PERSON CYCLE THRU 30-40 GALS THRU FILL LINE. NO LEAKAGE NOTED. LAV
Back to Boeing 757-222