Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA03530Lock · wornDOOR 1R SLIDE LIGHT WILL NOT COME ON. FOUND LOCK ASSY WORN. REPLACED AFT GIRT BAR LOCK ASSY. AND ADJUST RECEIVER, SUSPECT WORN. LOCK, CHECKED SEVERAL TIMES AND LIGHT COMES ON.SDR 2008UALA03518Slide · out of toleranceSLIDE PRESSURE AT DOOR 4L OUT OF GREEN BAND. REPLACED SLIDE ASSY, OPS CHECKED GOOD.SDR 2008UALA03501Girt Bar · obstructedTHE 2L WILL NOT ARM. DEBRIS UNDER GIRT BAR. CLEANED DEBRIS FROM UNDER GIRT BAR. DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA03492Bearing · corrodedTHE 3R DOOR HARD TO ARM & DISARM. INTERNAL BEARING RUSTED AND SIEZED. REPLACED BEARING. DOOR OPS NORMALLY.SDR 2008UALA03529Lamp · weakDOOR "ARMED" LIGHT NOT BRIGHT ENOUGH AT DOOR 2R. FOUND A WEAK LAMP. REPLACED LIGHT ASSY PER WDM 25-66-11 AND CLEANED PROX SWITCHES AND OPS CK GOOD.SDR 2008UALA03528Spring · brokenDOOR 2R EVAC SLIDE ARM-DISARM LEVER COVER DOOR HAS BROKEN RETURN SPRING. REPLACED ARM DISARM DOOR COVER.SDR 2008UALA03527Bulb · inoperativeLEFT AFT OVERWING EXIT EMERGENCY LIGHT FWD AND ABOVE HATCH INOP WHEN LIGHTS SELECTED ON. RELAMPED BULB, OPS CHECKED GOOD.SDR 2008UALA03495Pcu · defectiveWHILE TROUBLESHOOTING DF053 WITH A RT ELEVATOR PCU MESSAGE, GOT LT PCU MESSAGE ON EICAS. TROUBLESHOT MESSAGE DOWN TO LT ELEVATOR RT PCU BAD. REPLACED PCU, OPS CHECKED GOOD.SDR 2008UALA03489Structure · damagedDOOR 2L NEEDS REPAIR DOUBLER AT UPPER HINGE CUTOUT. ACCOMPLISHED MAJOR REPAIR AT GSO. ACP HFEC NO DEFECT FOUND. INSTALLED REPAIR DOUBLER IAW MM 52-11-87.SDR 2008UALA03488Structure · crackedDOOR 2R NEEDS REPAIR DOUBLER AT UPPER HINGE CUTOUT. ACCOMPLISHED MAJOR REPAIR AT GSO. ACP HFEC FOUND CRACK IN LW RT INBOARD CORNER REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR IAW MM.SDR 2008UALA03481Cylinder · corrodedGLAND NUT AND CARRIER CORRODED, REMOVED INNER CYL FOUND. EXTENSIVE CORROSION ON INNER SURFACE OF OUTER CYL. REPLACED LT MAIN LANDING GEAR, GEAR SENT TO SHOP FOR OVERHAUL.SDR 2008UALA03469Girt Bar · obstructedDOOR 4R ARMING LEVER OUT OF ADJUSTMENT. FOUND A PIECE OF SAFETY WIRE AT THE GIRT BAR MECHANISM PUSHROD, CAUSING ROD TO BIND. REPOSITIONED WIRE, AFTER RE-INSTALL, OPS CHECK OF DOOR EMERGENCY MECHANISM, NORMAL NO BINDING.SDR 2008UALA03478Sensor · faultyAPU FAILED 3 START ATTEMPTS AT FL360. APU 60189 HAS EXHIBITED STARTING ISSUES SINCE LATE MAY. PRIOR TO THIS EVENT ECU MR49613-127 WAS REPLACED WITH MR49613-40 ON 6/8/08. THE -127 UNIT TESTED WITH NO FAULT FOUND. INLET PRESSURE SENSOR MR49533-225 WAS REPLACSDR 2008UALA03462Battery · failedAIRCRAFT WILL NOT ACCEPT POWER. MAIN BATTERY FAILURE. REPLACED MAIN AIRCRAFT BATTERY, CHECKS GOOD.SDR 2008UALA03450Light · unsecureTHE 13C EXIT PATH LIGHTING IS WARPED. SECURED EEL STRIP TO FLOOR, OPS OK.SDR 2008UALA03449Heat Exchanger · damagedSERVICED IDG WITH 46 PUMPS OF OIL CONSUMPTION IN 9 HOURS. FUEL/OIL HEAT EXCHANGER BREAKING DOWN CAUSING AN OIL STARVE IN THE IDG. REPLACED IDG.SDR 2008UALA03442Skin · dentedDENT TO LOWER FUSELAGE AT STA 1720 JUST BELOW EMPENNAGE ACCESS DOOR. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE. INSTALLED DOUBLER REPAIR.SDR 2008UALA03441Frame · dentedFWD CARGO PIT STA 620 STR 24L FRAME HAS DENT. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR 2008UALA03440Frame · dentedAFT PIT FRAME AT FS 1360 STR 26L HAS 1EA DENT. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR 2008UALA03433Light · damagedESCAPE LIGHTING ON FLOOR BETWEEN ROWS 12 & 13 IS NEEDING REPAIR. REPAIRED LENS STRIP.SDR 2008UALA03432Ground Wire · damagedRUDDER TRIM FAILED TO TRIM IN EITHER DIRECTION. WIRING SHORT AT S3 SWITCH. REPAIRED GROUND TO S3 SWITCH ON M74 PANEL, SYSTEM CHECKED OK.SDR 2008UALA03412Slide · out of positionFOUND DOOR 1L SLIDE ON FLOOR. RESECURED SLIDE.SDR 2008UALA03395Light · inoperativeDOOR 4R EMERGENCY LIGHT INOP, EXTERIOR. LAMP INOP. RELAMPED EMERGENCY LIGHT, OPS CHECKED GOOD.SDR 2008UALA03387Connector · looseEEL'S RIGHT SIDE BY DOOR 1R, OVER DOOR 1R AND CTR, EXIT BETWEEN 1ST CLASS AND ECONOMY, EEL ABOVE SEAT 14C ARE INOP. LOOSE CONNECTOR. SECURED CONNECTOR FOR POWER SUPPLY FOR EMERGENCY EXIT SIGNS AT DOOR 1R AND CTR AND TEST, FOUND GOOD.SDR 2008UALA03398Girt Bar · faultyDOOR 3R NOT ARMING. REMOVED SLIDE AT DOOR 3R, LUBED ARMED, DISARMED BEARINGS AND OPS CHECKED SLIDE OPERATION.SDR 2008UALA03397Oil Cooler · leakingRIGHT IDG DRIVE LIGHT CAME ON JUST AFTER T/O. FUEL OIL COOLER FAILURE CAUSING LOW OIL QTY IN IDG. IDG SHUTDOWN. REPLACED NR 2 ENG FUEL/OIL COOLER AND REPLACED BYPASS VALVE ON COOLER. ALL LEAK CHECKS PERFORMED.SDR 2008UALA03396Connector · dirtyEICAS MSG - LEFT ENGINE FIRE LOOP 1. DIRTY CONNECTION. CLEANED ALL FIRE LOOP CONNECTORS ON NUMBER 1 ENG, SYS OPS CHECKED OK.SDR 2008UALA03399Cover · brokenEMERGENCY LIGHT STRIP ROW 34 NEEDS REPAIR. REPLACED BROKEN STRIP COVER. EMERGENCY LIGHT CHECKS OK.SDR 2008UALA03390Frame · dentedAFT PIT FRAME STA 1480 STR 26L HAD DENT. ACCOMPLISHED MAJOR REPAIR AT GSO. REPAIRED IAW SRM 53-00-07 REPAIR 5. THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES SUPPLEMENTAL INSP STARTING AT 50,000 TOTAL FLT CYCLES PER SRM 53-00-07 REPAIR 5 TBL II AND 12,000FC SDR 2008UALA03389Frame · dentedAFT PIT FS 1520 STR 26L HAS DENT IN FRAME. ACCOMPLISHED MAJOR REPAIR AT GSO. REPAIRED IAW SRM 53-00-07 REPAIR 5. THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES SUPPLEMENTAL INSP STARTING AT 50,000 TOTAL FLT CYCLES PER SRM 53-00-07 RPR 5 TBL II AND 12,000FC TSDR 2008UALA03388Frame · dentedAFT PIT FRAME AT BS 1320 BETWEEN STR 25R-26R INBOARD FLANGE IS DENTED. ACCOMPLISHED MAJOR REPAIR AT GSO. REPAIRED IAW SRM 53-00-07 RPR 5. THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES SUPPLEMENTAL INSP STARTING AT 50,000 TOTAL FLT CYCLES PER SRM 53-00-07 RESDR 2008UALA03386Smoke Detector · inoperativeK-LAV SMOKE DETECTOR IS INOPERATIVE. SMOKE DETECTOR IS INOP. REPLACED K LAV SMOKE DETECTOR. OPS CHECKED NORMAL.SDR 2008UALA03385Skin · dentedDENT AT APPROX STA 630 LT APPROX 2' BELOW WINDOW. ACCOMPLISHED A MAJOR REPAIR AT DEN. THIS IS A CAT B RPR AND REQUIRES SUPPLEMENTAL INSP TO BEGIN AT 37500FC. 5 CF ITEMS BEING CREATED TO ACP THIS TASK PER EVA 71659 CREATED CF9049, CF9050, CF9051, CF9052 AND CSDR 2008UALA03384Light · inoperativeEXTERNAL FWD OVERWING EMERGENCY EXIT LIGHT INOP RT. LAMP INOP. RELAMPED EXIT LIGHT ASSY, OPS CHECKED NORMAL.SDR 2008UALA03355Controller · faultyCABIN ALTITUDE CONTROL PANEL WHEN SELECTED TO MANUAL "AUTO OFF" LIGHT DOES NOT COME ON. CONTROLLER IS FAULTY. REPLACED CABIN PRESSURE SELECTOR AND AUTOMATIC PRESSURE CONTROLLER 2. OPS CHECK OK.SDR 2008UALA03342Idg · failedRIGHT GENERATOR DISCONNECTED. RTFL. IDG FAILURE (LOW OIL) - TEARDOWN INCONCLUSIVE. REPLACED IDG.SDR 2008UALA03356Hose · damagedOXYGEN MASK HOSE DEFECTIVE AT 2 (1=CAPT, 2=1ST OF, 3= 1ST OBS). CREW COMMENTS: HOSE IS BROKEN. BROKEN MASK HOSE (UNKNOWN DAMAGE). REPLACED HOSE ASSY, OPS CHECKED GOOD.SDR 2008UALA03353Transmitter · out of adjustFLAP SLAT ELEC MESSAGE ON TAXI OUT. OUT OF ADJUSTMENT (TRANSMITTER). ADJUSTED RIGHT L/E SLAT POSITION TRANSMITTER - REPLACED LEFT L/E SLAT POSITION TRANSMITTER PER MM 27-88-01-401. ADJUSTED RIGHT L/E SLAT POSITION TRANSMITTER - ELECTRICAL ANGLE FOR FLAP LEVSDR 2008UALA03352Girt Bar · obstructedTHE 1R DOOR WILL NOT ARM. DEBRIS UNDER GIRT BAR. CLEANED DEBRIS UNDER GIRT BAR. DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA03349Connector · defectiveLOCK MISSING FOR S LAV SMOKE DETECTOR CONNECTOR (P15). REPLACED P15 CONNECTOR ON S LAV SMOKE DETECTOR, OPS CHECKS GOOD.SDR 2008UALA03348Light · inoperativeEMERGENCY EXIT IDENTIFIER LIGHTS AT 15F AND 16A INOP. LIGHT ASSY HAS A SHORT INTERNAL. REPLACED 16A EMERGENCY EXIT IDENTIFIER LIGHT ASSY & CLEANED 15F CONNECTOR. OPS CHECK OK.SDR 2008UALA03329Sensor · failedPER CREW LEFT ENG BLEED LIGHT CAME ON. RTFL. FAN AIR TEMP SENSOR FAILURE. REPLACED FAN AIR TEMP SENSOR AND FAN AIR OVERTEMP SWITCH. ACCOMPLISHED A HIGH POWER RUN, ALL SYSTEMS NORMAL.SDR 2008UALA03335Spring · brokenNR 1 DOOR SLIDE ARM LEVER COVER SPRING BROKEN. DOES NOT STOW CORRECTLY. REPLACED COVER, FUNCTIONS CORRECTLY.SDR 2008UALA03334Acm · faultyAFTER TURNING ON APU & PACKS SMOKE IN CABIN SET OFF SMOKE ALARMS. ACM FAILURE, POSSIBLE BEARING FROZEN. REPLACED ACM, OPS CHECK GOOD.SDR 2008UALA03333Light · inoperativeDOOR 4R EXT EMERGENCY LIGHT INOP. BULB INOP. RELAMPED DOOR 4R EXT EMERGENCY LIGHT, OPS CHECK OK.SDR 2008UALA03332Light · inoperativeDOOR 2R EXT EMERGENCY LIGHT INOP. BULB INOP. RELAMPED DOOR 2R EXT EMERGENCY LIGHT, OPS CHECK OK.SDR 2008UALA03331Light · inoperativeDOOR 4L EXT EMERGENCY LIGHT INOP. BULB INOP. RELAMPED DOOR 4L EXT EMERGENCY LIGHT, OPS CHECK OK.SDR 2008UALA03330Girt Bar · out of adjustDOOR 3R WILL NOT ARM. GIRT BAR SETTING OUT OF ADJUSTMENT. ADJUSTED GIRT BAR SETTING, ARMS/DISARMS NORMALLY.SDR 2008UALA03319Wire Harness · shortedRECEIVED "L ENG SECONDARY CONTROL" EICAS STATUS MSG. WIRING HARNESS D42048 HAS SHORTED. REPAIRED HARNESS D42048, ALL CONT CHECKS ARE GOOD, ITEM HAS NOT REPEATED.SDR 2008UALA03318Wire · shortedFIRST OBSERVER'S MASK P/A DOES NOT TRANSMIT. WIRE SHORT. REPLACED FIRST OBSERVERS O2 MASK STOWAGE BOX, OPS CHECK GOOD.
Back to Boeing 757-222