Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA01824Frame · dentedFWD PIT AT STA 580 BETWEEN STR 23L AND 24L , FRAME INBOARD FLANGE DENTED. CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR.SDR 2008UALA01814Smoke Goggles · damagedCAPT SMOKE GOGGLE DAMAGED. REPLACED SMOKE GOOGLE.SDR 2008UALA01782Actuator · weakGEAR SELECTED DOWN "DOORS" LIGHT AND "GEAR DOORS" EICAS. DURING TAXI IN TO GATE RT MLG DOOR WAS NOT CLOSED, DOOR WAS HANGING OPEN. FOUND ACTUATOR (DOOR) WEAK- POSSIBLE WATER CONTAMINATION. REPLACED RIGHT MLG DOOR ACT, PERFORMED SEVERAL DOOR/GEAR SWINGS, ALSDR 2008UALA01781Seal · leakingNR 2 ENGINE HIGH OIL CONSUMPTION EXCEEDS LIMIT. FOUND STARTER DRIVE SHAFT SEAL FAILED. REPLACED STARTER DRIVE SEAL, LEAK CHECKED GOOD.SDR 2008UALA01775Oxygen Mask · crackedCAPTAIN'S OXYGEN MASK CRACKED. REPLACED MASK, OPS CHECKED NORMAL.
SDR 2008UALA01813Seal · leakingCHECK FOR O2 LEAK LOST 100 PSI DURING 4 HOUR FLIGHT. FOUND LEAKING SEAL WITHIN CAPT O2 BOX. REMOVED AND REPLACED CAPT O2 BOX, NO LEAKS NOTED AFTER.SDR 2008UALA01789Actuator · faultyLOWER EICAS R ENG PRI CONT WARNING ILLUM. FOUND NR 2 ENG SVA FAILURE. REPLACED NR 2 ENG SVASDR 2008UALA01780Filter · cloggedEQUIPMENT COOLING HORN AT DEPARTURE. FOUND EQ COOLING FAN FILTER CLOGGED. REPLACED FILTER, OPS CHECKED GOOD.SDR 2008UALA01774Generator · failedEICAS MSG APU GEN OFF DISPLAYED AND APU GEN OFF LIGHT ILLUM WITH APU RUNNING. APU FIELD OFF LIGHT ON. APU GEN FIELD WOULD NOT RESET, RESET THEN RETRIPPED. FOUND APU GENERATOR FAILED. REPLACED APU GEN, OPS CHECK GOOD.SDR 2008UALA01772Lanyard · out of positionCANNOT GET DOOR 1R TO ARM. FOUND LANYARD HANGING DOWN, CAUSING INTERFERENCE. RESTOWED LANYARD, OPS CHECKED GOOD.
SDR 2008UALA01757Girt Bar · dirtyFOUND DOOR 1R GIRT BAR IS FAULTY. FOUND DIRT ACCUMULATING UNDER GIRT BAR. CLEANED GIRT BAR TRACKS, DOOR OPERATES, ARMS/DISRAMS NORMALLY.SDR 2008UALA01743Warning System · activatedON APPROACH FLT EXPERIENCED A YELLOW GEAR DOOR WHEN LANDING GEAR WAS LOWERED. WHEELS SHOWED 3 GREEN. ALSO, A YELLOW AUTO SPEEDBRAKE LIGHT WHEN ATTEMPTED TO ARM. FLT EXECUTED A GO AROUND AND CONTACTED DISPATCH. ACCOMPLISHED BITE OF PSEU NO FAULTS NOTED. OPERSDR 2008UALA01755Fuse · blown1L DOOR EXT EMERGENCY SLIDE LIGHT INOP STA 385 AND AISLE EXIT SIGN FWD SIDE, FWD OF S LAV INOP STA 535. SUPPLEMENTAL DATA UPDATE, REMOVED AND REPLACED BLOWN FUSE ON EMERGENCY LIGHTS POWER SUPPLY M731. OP CHK'D GOOD.SDR 2008UALA01756Lamp · inoperativeFOUND EMERGENCY LIGHTS AT DOOR 4R AND FWD LEFT OVERWING INOP. RELAMPED BULBS AND OPS CHECKED GOOD.SDR 2008UALA01741Frame · dentedFOUND FWD PIT FRAME DENTED 2 PLACES AT STA 540 STR 25L. REPAIRED PER REO G 12281 R EV B AND EVA 71348.
SDR 2008UALA01740Frame · dentedFOUND FWD PIT FRAME DENTED AT STA 560 STR 25L. REPAIRED PER REO G 12282 R EV D AND EVA 71349.SDR 2008UALA01720Sensor · faultyFOUND DOOR 2R SLIDE LIGHT INDICATOR INOP. FOUND A WEAK PROX SENSOR. REPLACED PROX SENSOR 585-3162 AT DOOR 2R AT AFT POSITION.SDR 2008UALA01714Frame · dentedFWD PIT AT STA 600 AT STR 24L, FRAME INBOARD FLANGE DENTED. CUT OUT DAMAGE FABRICATED AND INSTALLED REPAIR IAW SRM. THIS IS A CAT B ZONE 2 RPR WHICH REQUIRES SUPPLEMENTAL VISUAL AND NDT INSPECTIONS TO BEGIN WHEN ACFT REACHES 45,636C AND 11,000C THEREAFTER. SDR 2008UALA01713Frame · dentedAFT PIT FRAME INBOARD FLANGE IS DENTED AT STA 1500 AND STR 26L. CUT OUT DAMAGE FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07 RPR 5. THIS IS A CAT B ZONE 1 RPR WHICH REQU IRES SUPPLEMENTAL VISUAL AND NDT INSPECTIONS TO BEGIN WHEN ACFT REACHES 50,000C AND 12SDR 2008UALA01712Skin · burnedBURN IN SKIN STA 430 BETWEEN STR 22R AND 23R.SDR 2008UALA01711Girt Bar · bentDOOR 1L DOES NOT DISARM. FOUND GIRT BAR ASSY BENT/DAMAGED. REPLACED GIRT BAR ASSY AND DOOR ARMS/DISARMS NORMALLY.
SDR 2008UALA01702Door · out of rigDOOR 2 LEFT UNABLE TO ARM, FOUND DOOR OUT OF RIG. FOUND UPPER AND LOWER JAMB NUTS ON TORQ TUBE LOOSE. ON INSP FOUND TANG WASHER INSTALLED INCORRECTLY. LOWER GATE IS STRIKING DOOR THRESHOLD UPON DOOR CLOSURE. BY- 124277 :LOWER JAM NUT LOCK WASHER IS INSTALLEDSDR 2008UALA01698Lamp · inoperativeDOOR 2L ARM LIGHT NOT ILLUMINATED WITH DOOR ARMED. CYCLED ARMING LEVER, NO HELP. FOUND LAMP IS OUT IN INDICATOR. RELAMPED DOOR ARM SWITCH AT DOOR 2L AND RESET GIRT BAR, OVERHEAD CB OPS CHECKED NORMAL.
SDR 2008UALA01693Structure · corrodedMAIN CABIN T-CAP PREVIOUS REPAIR CORRODED AT BS 324 AND RBL 35. REMOVED DAMAGED AREA, FABRICATED RPR MATERIAL AND INSTALLED IAW SRM 51-40-02 AND MM 53-00- 98SDR 2008UALA01692Frame · dentedFOUND FWD PIT FRAME DENTED STA 640 STR 25L. REMOVED DAMAGE FABRICATED REPAIR AND INSTALLED IAW SRM 53-00-07 RPR 5 THIS IS A CAT B REPAIR IN ZONE 1 AND REQUIRES SUPPLEMENTAL VISUAL AND NDT INSPECTIONS TO BEGIN 29,294C AFTER RPR INSTALLED, AND REPET ATIVE INSPSSDR 2008UALA01691Frame · dentedFOUND FWD PIT FRAME DENTED STA 600 STR 25L. REMOVED DAMAGE FABRICATED REPAIR AND INSTALLED IAW SRM 53-00-07 RPR 5 ON NR 22857 BY MECH 111857 AND INSP BY QC 071. PER SRM 53-00-07 RPR 5 TABLE II THIS IS A CAT B REPAIR IN ZONE 2 AND
REQUIRES SUPPLEMENTAL VSDR 2008UALA01687Oxygen Mask · no testF/O OXYGEN MASK WILL NOT TEST. CAUSE, UNKNOWN. REPLACED STOW BOX ASSY, OPS CHECKED OK.SDR 2008UALA01685Wire · damagedEEL STRIP INOP IN FRONT OF MID AFT LAV. CAUSE, DAMAGED WIRING FROM UNKNOWN SOURCE. SPLICED WIRE ON EEL STRIP. OPS CHECKED OK.SDR 2008UALA01669Light · unsecureEXIT PATH LIGHTING NOT SECURED TO FLOOR AT ROW 13 ABC. CAUSE, UNKNOWN. SECURED EEL LIGHT TO FLOOR TRACK.SDR 2008UALA01667Frame · dentedAFT PIT FS 1400 FRAME DENTED STR 26L. CAUSE, UNKNOWN. AFT PIT FS 1400 FRAME DENTED STR 26L. REMOVED DAMAGED SECTION OF FRAME INBOARD FLANGE. FABRICATED -5 'J' DOUBLER AND STRINGER CLIPS AND INSTALLED PER REPAIR 5. THIS IS A CAT B REPAIR IN ZONE 2 AND REQUSDR 2008UALA01666Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT DOOR 4R. CAUSE, LAMP INOP. RELAMPED ASSY, OPS CHECKED OK.SDR 2008UALA01686Oxygen System · reads lowCREW O2 READING 1200 (LOW). CAUSE, UNKNOWN. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA01652Feeder Cable · shortedMID CABIN FLOOR EMERGENCY ESCAPE PATH LIGHTS INOP AT SEAT ROW 9ABC-13ABC. SUPPLEMENTAL DATA UPDATE CAUSE, JUMPER CABLE AT ROW 13ABC SHORTED. REPLACED JUMPER CABLE ASSY FOR ROW 13 ABC. OPS CHECKED OK.SDR 2008UALA01653Oxygen Mask · misinstalledCAPT'S RESET-TEST LEVER ON O2 MASK DOOR IS INOP. SUPPLEMENTAL DATA UPDATE CAUSE, MASK NOT STOWED PROPERLY. REINSTALLED MASK ASSY IN POSITION.SDR 2008UALA01625Torque Tube · gougedDOOR R1 HAS GOUGE ON INNER DOUBLER AT UPPER HINGE TORQUE TUBE. SUPPLEMENTAL DATA UPDATE, MAJOR REPAIR, REPAIR ACCOMPLISHED AT GSO.SDR 2008UALA01620Wire · brokenDOOR 1R EMERGENCY LIGHT INOP. SUPPLEMENTAL DATA UPDATE CAUSE, FOUND BROKEN WIRE AT LIGHT L30. REPAIRED WIRE AT L30 AND REPLACED POWER SUPPLY M730. OPS CHECKED NORMALLY.SDR 2008UALA01651Lamp · inoperativeDOOR 1L EMERGENCY LIGHT INOPERATIVE. SUPPLEMENTAL DATA UPDATE, CAUSE LAMP IS INOP. RELAMPED ASSY, OPS CHECKED OK.SDR 2008UALA01618Sensor · failedGIRT-BAR ARM LT C/B TRIPPING, UNABLE TO ISOLATE FAULT. FOUND PROX SWITCH SW10216 FAILED. REPLACED PROX SWITCH SW10216.GIRT BAR LIGHT WORKS OK.SDR 2008UALA01668Wire · shortedNR 2 RT EXIT SIGN SLIDE LIGHT INOP. CAUSE, SHORT IN WIRING AT LIGHT SIGN ASSY AND POSSIBLE FAULTY PROX SENSOR ASSOCIATED WITH SYSTEM. REMOVED AND REPLACED DOOR SLIDE LT ASSY, AND DOOR GIRT BAR PROX SENSORS, OPS CHECK GOOD.SDR 2008UALA01613Button · missingOVERHEAD PANEL EVAC HORN SHUTOFF BUTTON MISSING. REPLACED EMER EVAC PANEL.SDR 2008UALA01612Lamp · inoperativeDOOR 4R OUTSIDE EMERGENCY LIGHT INOP. RELAMPED EMER LIGHT AT 4R, OPS CHECKED NORMALLY.SDR 2008UALA01611Knob · missingEMERGENCY EVACUATION PANEL HAS MISSING HORN SHUTOFF KNOB MISSING IN FLIGHT DECK COMPARTMENT. REPLACED EES PANEL, OPS CHECKED NORMAL.SDR 2008UALA01607Pin · crackedNR 1 PYLON, LT MIDSPAR FUSE PIN HAS CRACK INDICATIONS IN INSIDE DIAMETER. MAJOR REPAIR ACCOMPLISHED: MIDSPAR FUSE PIN IS REPLACED WITH NEW PIN (P/N 311N5500-1).SDR 2008UALA01605Skin · dentedLEFT EXTERNAL FUSELAGE STA 600-640, STR 15L - 17L, 3 EA DENTS, 2 EA OF WHICH ARE ON EXISTING DOUBLER. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED SKIN & INSTALLED DOUBLER REPAIR.SDR 2008UALA01593Proximity Switch · failedNO SLIDE ARMED LIGHT 2L. FOUND PROXIMITY SWITCH FAILED. REPLACED PROX SWITCH "A" S10218, OPS CHECKED GOOD.SDR 2008UALA01582Lamp · inoperativeEXTERIOR EMERGENCY LIGHTS INOP AT DOOR 4L AND 4R. FOUND LAMP INOPERATIVE. REPLACED LAMP, CHECKED OK.SDR 2008UALA01581Frame · damagedFWD PIT FRAME REPAIR AT STA 800, STR 28L TO STR 28R HAS DAMAGE. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA01580Frame · damagedFWD PIT REPAIR ON FRAME STA 780 STR 28L AND STR 28R HAS DAMAGE. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA01579Frame · damagedFWD PIT FRAME AT STA 760 STR 28L TO STR 28R HAS DAMAGE. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA01577Frame · damagedFWD PIT FRAME REPAIR AT STA 740 STR 28L TO STR 28R. ACCOMPLISHED MAJOR REPAIR.
Back to Boeing 757-222