SDR 2007UALA01466Bottle · reads lowEMERGENCY ESCAPE LIGHT REMAINED EXTINGUISHED DURING SLIDE SQUIB TEST 2 ON SIDE 5 (05=L, 06=R). [SUP 06-06-07] FOUND LEFT OVERWING EVAC SLIDE BOTTLE PRESS LOW. ACCOMPLISHED A ONE TIME RECHARGE. SQUIB TEST OK. CYLINDER REPLACED AT FIRST MAINT STATION WHERE PSDR 2007UALA01454Structure · crackedMED 2R FRAME IS DAMAGED. [SUP 06-06-07] HFEC INSP FOUND CRACK AT FWD FRAME UPPER HINGE CUT OUT. INSTALLED A DOUBLER REPAIR PER UA APPROVED SPECIFICATION.SDR 2007UALA01448Engine · damagedRTFL DUE TO BIRDSTRIKE TO NR 2 ENGINE. NR 2 ENG, WHILE PERFORMING FIM MULTIPLE METAL PIECES FOUND IN THE 10TH STAGE BLEED DUCT AND IN THE PRE COOLER.SDR 2007UALA01467Girt Bar · stiffDOOR 3R DOOR ARM DISARM SWITCH VERY STIFF AND DIFFICULT TO USE. [SUP 06-06-07] REMOVED SLIDE LUBED MECHANISM TO ALLEVIATE THE STIFFNESS CONDITION.SDR 2007UALA01446Engine · making metalDIVERTED DUE TO RIGHT ENGINE OIL FILTER PRESSURE INDICATOR. AMBER ALERT DECLARED. NR 2 ENG MAIN OIL FILTER HAS LARGE QTY OF FERROUS FLAKES. [SUP 06-06-07] ALSO CHECKED NR 123 AND NR 5 BEARING C-D'S AND FOUND EXCESSIVE MATERIAL. FILTER AND C'D'S REINSTALLESDR 2007UALA01445Bottle · no testRIGHT EMERGENCY ESCAPE TEST 2 FAILED. ACCOMPLISHED 1 TIME RECHARGE OF SERVICE BOTTLE. BOTTLE REPLACED AT THE FIRST MAINT OPPORTUNITY.SDR 2007UALA01444Control Module · out of rigEXECUTED A GO AROUND DUE TO VERBAL TOO LOW/TERRAIN AND LANDING GEAR WARNING MESSAGES. ACCOMPLISHED TROUBLESHOOTING. NO FAULTS FOUND. FOUND GEAR HANDLE BINDING IN DOWN POSITION WHEN PULLING HANDLE OUT OF DETENT. BINDING IS WORSE WITH HYDRAULICS ON. REPLACESDR 2007UALA01439Light · inoperativeEMERGENCY AISLE LIGHTS INOP & LOOSE IN MOUNTING AT ROWS 13 & 32. [SUP 06-06-07] REPLACED THE HOUSINGS AND TESTED SATISFACTORILY.SDR 2007UALA01419Bulb · faultyNUMBER 1 SQUIB TEST FAILURE FOR LEFT EMERGENCY ESCAPE SLIDE. CLEANED AND RELAMPED BULB. [SUP 06-06-07] CLEANED AND RELAMPED BULB. ACCOMPLISHED SQUIB TEST SEVERAL TIMES ON P61 PANEL. TESTED OK.SDR 2007UALA01427Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT AT DOOR 1 LEFT IS INOP. [SUP 06-06-07] RELAMPED.SDR 2007UALA01426Connector · dirtyLEFT OFF WING SLIDE BOTTLE SQUIB, TEST LIGHT ON P-61 PNL STAYS ON. CLEANED CONNECTOR AND OPS CHECK GOOD.SDR 2007UALA01425Battery · inoperativeEMERGENCY SLIDE LIGHT ON EXTERIOR OF AFT CARGO DOOR, EMERGENCY AISLE LIGHT IN STOW BIN BULLNOSE AT LEFT ROW 26 & EMERGENCY OVERHEAD EXIT SIGN AT ROW 15-16 ARE INOPERATIVE. REPLACED BATTERY PACK FOR POWER SUPPLIES.SDR 2007UALA01414Connector · looseRTFL DUE TO LEFT AFT FUEL BOOST PUMP INOPERATIVE. [SUP 06-06-07] LEFT AFT FUEL PUMP ANNUNCIATED EICAS & LOW PRESS ON IN SWITCH. FOUND NR 1 ENG DRIVEN HYD PUMP CONNECTOR LOOSE. SECURED NR 1 ENGINE EDP DEPRESSURIZATION SOLENOID AS REQUIRED.SDR 2007UALA01408Pulley · crackedCABIN CROWN AREA, 2 EACH ELEVATOR CONTROL CABLE PULLEYS ARE CRACKED AT STA 340 BETWEEN STR 2L AND STR 3L. [SUP 06-06-07] REMOVED AND REPLACED PULLEYS AT STA 340 AND VERIFIED CABLE TENSION. ACCOMPLISHED FUNCTIONAL CHECK.SDR 2007UALA01399Actuator · malfunctionedRUDDER TRIM FAILED TO TRIM IN LEFT DIRECTION. [SUP 06-06-07] DURING DESCENT STARTED TO WORK ERRATICALLY IN ONE DIRECTION. BY THE TIME IT ARRIVED AT GATE, IT OPERATED NORMALLY. REPLACED RUDDER TRIM ACTUATOR. ACCOMPLISHED INSPECTION OF RUDDER TRIM ACTUATORSDR 2007UALA01396Floor Support · corrodedAFT PIT FLOOR PNL SUPPORT STR AT LBL 3 HAS CORROSION IN STA 1330 AREA. [SUP 06-06-07] FABRICATED REPAIR REPAIR VII. ORIGINAL MATERIAL 0.063, REMAINING AFTER CLEAN UP 0.044. INSTALLED REPAIR PER UA ENGINEERING SPECIFICATIONS.SDR 2007UALA01395Warning System · activatedRECEIVED FLAPS DISAGREE INDICATION ON APPROACH. [SUP 06-06-07] FLAPS FAILED TO MOVE. TRAILING EDGE LIGHT ILLUMINATED. EICAS MESSAGE 'TE FLAP DISAGREE' DISPLAYED. FLAPS OPERATE NORMALLY ON ALTERNATE SYSTEM. CONDUCTED OPERATION CHECKS OF THE FLAP AND LEADINSDR 2007UALA01393Pump · malfunctionedLANDED UNDER AMBER ALERT DUE TO LOSS OF LEFT ENGINE HYDRAULIC PUMP. [SUP 06-01-07] LT HYD SYSTEM FAILED. REPLACED NR 1 ENGINE DRIVEN HYD PUMP. ALSO REPLACED LT EDP PRESSURE AND CASE DRAIN FILTER.SDR 2007UALA01387Lever · stiffDOOR 1L DOES NOT ARM, LEVER IS STIFF. [SUP 06-06-07] GIRT BAR LIFT SPRING WAS JAMMED REPLACED LEFT DOOR GIRT BAR AND BAR LOCK AND REPLACED LEFT DOOR ASSIST BOTTLE.SDR 2007UALA01383Floorbeam · corrodedRIGHT MAIN CABIN FLOOR STRUCTURE, EVIDENCE OF CORROSION BETWEEN FLOOR WEB AND SUPPORT ANGLE, BS 1681, RBL 34. MAJOR REPAIR ACCOMPLISHED: REMOVED ENTIRE LENGTH OF DAMAGED FLOORBEAM T-CAP. FABRICATED & INSTALLED REPLACEMENT CHORD.SDR 2007UALA01379Inverter · inoperativeF-C EMERGENCY ESCAPE PATH LIGHTING INOP. REPLACED POWER INVERTER. OPS CHECK NORMAL.SDR 2007UALA01376Structure · crackedCABIN DOOR 2 RIGHT CUTOUT FOR UPPER HINGE HAS 0.25 INCH CRACK. [SUP 06-06-07] INSTALLED A DOUBLER REPAIR ON THE AFFECTED AREA WITH BOEING APPROVED UA ENGINEERING SPECIFICATION.SDR 2007UALA01372Light · inoperativeR-1 EXTERIOR EMERGENCY LIGHT IS INOP. [SUP 05-16-07] RELAMPED.SDR 2007UALA01368Skin · crackedLOWER FUSELAGE SKIN DENTED AT BS 480 AT STR 22R. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED AREA. FABRICATED & INSTALLED FILLER & INTERNAL DOUBLER REPAIR.SDR 2007UALA01374Light · inoperativeEEL STRIP IN FRONT OF FWD AFT LAV INOPERATIVE. [SUP 05-08-07] REPLACED EEL STRIP. OPS CHK OK.SDR 2007UALA01373Switch · damagedEMERGENCY LIGHTS TEST SW S10295 BY L-4 DOOR HAS BROKEN TERMINALS. [SUP 06-06-07] REPLACED SWITCH.SDR 2007UALA01367Door Frame · crackedNR 2 LEFT DOOR FWD FRAME CUTOUT FOR UPPER HINGE CRACKED. [SUP 06-06-07] INSTALLED A DOUBLER REPAIR ON THE AFFECTED AREA WITH BOEING APPROVED UA ENGINEERING SPECIFICATION.SDR 2007UALA01358Pilot Valve · failedRTFL DUE TO SMOKE IN COCKPIT. [SUP 06-06-07] FOLLOWED SOP AND SHUTDOWN UTILITY BUSSES, ODOR AND SMOKE DISSIPATED SLIGHTLY. INSPECTION OF NR 1 ENG FOUND EVIDENCE OF OIL COMING OUT OF 2.8 COMPRESSOR BLEEDS AT 6 O'CLOCK & OUT OF 8TH STG BLEED PNEUMATIC DUCTS. SDR 2007UALA01348Door Frame · crackedR-2 DOOR FRAME IS CRACKED AT UPPER HINGE CUTOUT, .25 INCH LONG, FOUND AT THE 7 O'CLOCK POSITION. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED AREA. FABRICATED & INSTALLED A CRES DOUBLER.SDR 2007UALA01322Cooling Fan · cloggedFLIGHT DIVERTED DUE TO EQUIPMENT COOLING FAULT INDICATION. EQUIPMENT COOLING FAULT ON TAXI, ONCE CHECKLIST C-W AND ALTERNATE SELECTED EICAS CLEARED. NO CB'S FOUND POPPED ON FLIGHT DECK. COMPLIED WITH MEL CARD. REPLACED COOLING FAN FILTER.SDR 2007UALA01347Wire · damagedEEL BASE WIRE AT STA 1600 DAMAGED. REPLACED DAMAGED WIRE.SDR 2007UALA01346Light · brokenEEL LIGHT BAR BROKEN STA 740. REPLACED LIGHT BAR.SDR 2007UALA01342Indicator · sticksCREW REPORTS DOOR 4L WILL NOT ARM AT DEPARTURE. [SUP 06-06-07] DOOR FOUND TO ARM AND DISARM NORMAL. LUBE INDICATOR ARM POP OUT WAS STICKING AND APPEARED TO HAVE CAUSED THE PROBLEM WITH ARMING.SDR 2007UALA01345Frame · dentedFWD PIT, LEFT SIDE, STA 580 BETWEEN STR 24L AND 25L, MAIN FRAME IS DENTED 3 PLACES, WITH ONE INTO FRAME UPPER RADIUS BEND. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE. COLD WORK HOLES & INSTALLED DOUBLER REPAIR.SDR 2007UALA01344Frame · dentedFWD PIT, LEFT SIDE STA 660 BETWEEN STR 25 AND 26L, MAIN FRAME HAS DENT INTO RADIUS UPPER BEND. MAJOR REPAIR ACCOMPLISHED: TRIMMED OUT DAMAGE. COLD WORKED HOLES & INSTALLED J-ANGLE REPAIR.SDR 2007UALA01343Structure · crackedDOOR 2L HAS HALF INCH CRACK AT UPPER HINGE CUTOUT. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. INSTALLED CRES DOUBLER REPAIR.SDR 2007UALA01341Skin · damagedFUSELAGE DAMAGE TO AFT CARGO PIT DOOR THRESHOLD AND SURROUNDING STRUCTURE. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED SKIN. MFG & INSTALLED FILLER AND DOUBLER REPAIR. INSTALLED NEW CENTER THRESHOLD PLATE AND NEW FWD CORNER PLATE. SEALED ALL EDGES.SDR 2007UALA01359Skin · crackedNR 2 PYLON INBOARD SKIN IS CRACKED AT THE MOST FWD ACCESS HOLE, 2:00 O'CLOCK POSITION. [SUP 06-06-07] ACCOMPLISHED REPAIR WITH UA ENGINEERING SPECIFICATION.SDR 2007UALA01305Frame · dentedAFT PIT STA 1540 LT AT STR 25L, FRAME IS DENTED ON INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED: TRIMMED OUT DAMAGE. INSURANCE CUT & INSTALLED "J" ANGLE REPAIR.SDR 2007UALA01294Ring · missingDOOR 1L MISSING D RING. [06-14-07] FOUND LANYARD MISSING INSTALLED SERVICABLE LANYARD. INSTALLED. ()INSPECTED DOOR 3L AND D-RING IS INSTALLED. REPLACED LANYARD AT DOOR 1L.SDR 2007UALA01282Latch · faultyAFT OVERHEAD RAFT STOWAGE COMPARTMENT WILL NOT OPEN. [SUP 05-16-07] ADJUSTED LATCH. OP CHECKS OK.SDR 2007UALA01281Cable · frozenRT OVERWING SLIDE, MANUAL BACKUP CABLE IS FROZEN. [SUP 06-06-07] REPLACED CABLE, AND THE NON-FUNCTIONAL CABLE HAS BEEN THE ROOT CAUSE OF THE PROBLEM.SDR 2007UALA01266Stringer · crackedMAIN CABIN STR 15L CRACKED STA 680. [SUP 05-04-07] MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED STRINGER. FABRICATED & INSTALLED NEW CHORD.SDR 2007UALA01257Wire Harness · defectiveEEL FLOOR LIGHTS INOP FROM SEAT 24 TO 32. REPLACED CABLE ASSY. OPS CHECKED GOOD.SDR 2007UALA01253Lanyard · unsecureDOOR 4R WILL NOT ARM. [06-14-07] SECURED SLIDE LANYARD: OPS CHK GOOD.AND ARMS NORMALSDR 2007UALA01243Seal · leakingLOST BETWEEN 8-10 QTS OF OIL AT THE BEGINNING OF THE FLIGHT & BETWEEN 4-5 QTS THE LAST TWO HOURS OF THE FLIGHT. FOUND NR 2 ENG DEOILER OIL SEAL LEAKING. REPLACED DEOILER SEAL.SDR 2007UALA01258Slide · activatedRAMP PERSONNEL FOUND DOOR 1L SLIDE OFF DOOR AND ON FLOOR. [06-14-07] REASSEMBLED AND REATTACHED SLIDE TO DOOR 1L PER UA ENGINEERING SPECIFICATIONS.SDR 2007UALA01252Unknown · odorELECTRICAL BURNING ODOR IN COCKPIT & CABIN, DISSIPATED QUICKLY, TURNED OFF RIGHT RECIRCULATION FAN. [06-14-07] CONDUCTED TROUBLESHOOTING TO IDENTIFY WHETHER SOURCE OF ODOR COULD BE FWD E&E COMP OR PNEUMATICS. RAN PACKS SEVERAL HRS ALSO RT FAN UNABLE SDR 2007UALA01242Light · inoperative13C FLOOR STRIP LOOSE. EEL LIGHT INOP AT 13D. REPLACED EEL LAMP AND AND REUSED THE JUMPER AND STRIP, OPS CHECKED OK.SDR 2007UALA01239Wedge · delaminatedINBD SLAT WEDGE DELAMINATED T/E WEDGE DELAMINATED. T/E WEDGE REPLACED WITH NEW.
Back to Boeing 757-222