SDR CALA2014011490148Oil System · leakingNR 2 ENG OIL QTY DECREASING & PRESS DECREASING, ENG AT IDLE. IAW PTT SEQ 8902006, ENG EXTERNAL LEAKS CORRECTED, ENG OPERATIONS CHECK WILL BE ACCOMPLISHED ON SMC005.SDR CALA2014011390131Battery Pack · defectiveEMERGENCY EXIT LIGHTS INTERMITTENT ABOVE 1R. ACCOMPLISHED CALL OUT, ALL CONNECTORS CHECKED GOOD TO POWER SUPPLY IAW WDM33-51-12 PG10B. REPLACED POWER SUPPLY BATTERY PACK M730 IAW AMM33-51-07 PG201, OPERATIONS CHECKED NORMAL.SDR CALA2014011390128Feeder Cable · defectiveEMERGENCY EXIT LIGHT STRIP IN FRONT OF FIRST CLASS CLOSET & THE STRIP JUST AFT OF IT IS INOPERATIVE, COVER MISSING & TRACK LOOSE. REPLACED MOST FWD FEEDER CABLE & LIGHT STRIP, OPERATIONS CHECKED GOOD.SDR CALA2014011390132Skin · damagedEXTERNAL FUSELAGE SKIN CREASED BETWEEN BS 1380 TO 1400 & STRINGER 27R - 28R. REMOVED DAMAGED SKIN & FABRICATED A REPAIR DOUBLER, STRUCTURAL FILLER & FILLER & INSTALLED BETWEEN BS 1380 TO 1390 & AFT CARGO DOOR FWD LOWER CORNER OF CUT-OUT. IAW UAL ECRA 5360-01SDR CALA2014011390130Battery Pack · dischargedEMERGENCY EXIT LIGHTS ON FIRST CLASS COCKPIT DOOR 1R ON WHILE EMERGENCY LIGHTS ARMED. REPLACED M730 BATTERY PACK, OPERATIONS CHECKED OK.SDR CALA2014011390129Cooling Fan · faultyAFTER ENG START & PACKS ON, STRONG ELEC SMELL IN COCKPIT, RETURN TO GATE. REPLACED NR 1 EQUIP COOLING FAN IAW MM21-58-06 & REPLACED FILTER IAW MM21-58-07. OPERATIONS CHECKED GOOD BP SN IS 1810 & ME IS 19-2158-9-0001.SDR CALA2014011390127Warning Message · false activationSPOILER EICAS MESSAGE IN FLIGHT. ACCOMPLISHED FIM 27-61-00-101, FIG 103, 27-09-00-101, FIG 105A. NO EXISTING FAULTS FOUND ON ALL SCM'S. SCM 1R SHOWED INTERMITTENT PCA 2 FAULT IN CRUISE IN LAST LEG FAULT HISTORY. ACCOMPLISHED SPOILER SPEED BRAKE CONTROL SYSTSDR FDEA201401070061Floorbeam · corrodedBS 377.7, LBL 62 - 64 FLOORBEAM UPPER TEE FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02 REV 110. FOUND OUT OF LIMITS IAW SRM 53-00-51 FIG 101 REV 110. FLOORBEAM TEE REMOVED RBL 70 - LBL 70 IAW SRM 51-40-02 REV 111. NEW TEE FABRICATED IAW DWG 141N5123 SDR FDEA201401070062Floorbeam · chafedBS 560 LBL 14 - RBL 10 FLOORBEAM UPPER FLANGE FOUND CHAFED. REPAIRED IAW EA 757-5335-08-E2522 REV. REPAIR CLASSIFIED AS MINOR.SDR CALA2014010990108Sealant · missingPAX ENTRY SERVICE DOORS LT CTR, NOISE FROM AIR LEAK. FOUND AREAS AROUND THE DOOR HINGE COVERS MISSING SEALANT. RESEALED AREAS MISSING SEALANT NO NOISE HEARD WHEN PRESSURIZED AIRCRAFT.SDR CALA2014010790065Unknown · faultyMAIN FUEL TANK QTY DIFFERENCE OF 1600 LBS AFTER 2.5 HRS, LEFT SIDE HIGH. ALSO NOTED AIRCRAFT HEALTH MANAGEMENT SHOW FUEL FLOW HIGHER BY APPROXIMATELY 300 + ILB AT TAKEOFF & CLIMB & 100+ ILB IN FLT.SDR CALA2014010790063Status Message · activatedLT ENG FIRE LP 2 STATUS MESSAGE ON LOWER EICAS.SDR CALA2014010990105Pressure Switch · faultyLT ENG HYD PUMP PRESS LIGHT NOT ON WITH PUMP OFF. R & R LT ENG HYD PUMP PRESS IAW AMM 29-11-17-401, OPERATIONS CHECKED GOOD.SDR CALA2014010790061Unknown · malfunctionedFALSE TCAS RA ON FINAL APPROACH, MADE MANDATORY MANEUVER CAME AROUND SECOND ARR HAPPENED AGAIN.SDR CALA2014010790060Status Message · activatedRT ENG PRI CONT STATUS MESSAGE DISPLAYED AFTER ENG START. MESSAGE READ RT ENG PRI CONT & P T 2 EECSDR CALA2014010990106Valve · failedNR 1 ENG RFCC FAILED DURING TEST AMM 36-11-1 8 PG 406 STEP 6D 1 IAW SEQ 0352154. LT ENG BLEED AIR LIGHT FAILED TO STAY ON. R & R VLV IAW AMM 36-11-18, PART OFF 107494-4, SN OFF 1034, PN ON 10749 4-3 & SN ON 1007, REQUIRES OPERATIONS CHECK IAW 36-11-18, PG 40SDR FDEA201401030010Skin · damagedFUSELAGE SKIN NICKED & SCRATCHED BETWEEN STRINGERS 26L & 26R BS 1600 - 1620. REPAIRED IAW EA F-5330-T0305865 PART 1. REPAIR IS MINOR.SDR FDEA201401030009Skin · damagedFUSELAGE SKIN NICKED & SCRATCHED BETWEEN STRINGERS 26L & 26R BS 680 - 700. NICKS AND SCRATCHES REMOVED IAW SRM 51-10-02 REV 110. FOUND WITHIN LIMIT IAW SRM 53-00-01 FIG 101 DETAIL II REV 111. REPAIR CLASSIFIED MINOR AS PER GMM 6-2-100.SDR FDEA201401030008Skin · damagedFUSELAGE SKIN NICKED & SCRATCHED BETWEEN STRINGER 26L & 26R BS 440 - 460. REPAIRED IAW EA F-5330-T0306587 PART 1. REPAIR IS MINOR.SDR CALA2014010790057Duct · crackedDURING INSPECTION OF 2.5 BLEED ACT, FOUND CRACKED 2.5 BLEED PORT AT 7 O`CLOCK POSITION, UPPER LT HAND CORNER ABOUT 1.5 INCH CRACK.SDR CALA2014010790064Fan · faultyEQUIPMENT COOLING FAN GOING OFF. REPLACED LT RECIRCULATION FAN & RELAY K415 ON P70, OPERATIONS CHECKED NORMAL.SDR CALA2014010390048Antenna · faultyATC FAULT LIGHT ON, FOUND LT ATC TRANSPONDER FAILING UPPER & LOWER ANT & RT TRANSPONDER FAILING LOWER ANT.SDR CALA2014010790062Light · inoperativeEMERGENCY EXIT LIGHT STRIP IN FRONT OF AFT LAVATORY INOPERATIVE, ONE STRIP ONLY. ONE LIGHT STRIP ONLY IN FRONT OF AFT LAVATORY INOPERATIVE REST ILLUMINATE OKAY. REPLACED LIGHT ASSEMBLY, CHECKED OK.SDR CALA2014010290017Relay · failedLT ENG PROBE HEAT STATUS MESSAGE. REPLACED K10308. IDLE RUN BOTH ENGS FOR 10 MINUTES. NO STATUS MESSAGES DISPLAYED.SDR CALA2014010290016Fseu · malfunctionedFLAP SLAT SENSOR CB POPPED. REPLACED FSEU 1 IAW AMM 2 7-51-01. ALL TESTS PASSED.SDR CALA2014010290015Relay · faultyLT ENG PROBE HEAT STATUS MESSAGE. IAW FIM 30-34-00 & WDM 30-34-11 PG 2. REPLACED RELAY K10337 LT ENG OUT RELAY, MESSAGE CLEAR, OPERATIONS CHECKED NORMAL.SDR CALA2013123194072Sensor · faultyFWD CABIN COLDER THAN SELECTED WITH SWITCH ON & TEMP CONTROL IN AUTO. REPLACED COMP OUTLET SENSOR NR 2 ON PACK 2. OPERATIONS CHECKED OK. ALSO CLEANED COCKPIT TEMP SENSOR, FWD & AFT. RAN PACK & HAD CONTROL THRU OUT CABIN. DEF TEMP CONTROL.SDR CALA2014010290014Bolt · looseOIL LEAKING FROM NR 1 ENG FAN COWL. SECURED BOLT ON NR 1 ENG IDG, BOLTS TWO EACH ARE LOCATED AT 4 O'CLOCK POSITION. ACCOMPLISHED ENG RUN, NO LEAKS NOTED. SERVICED NR 1 ENG IDG.SDR CALA2014010290013Door Frame · damagedDOOR LEAK AT 2L, FOUND DOOR FRAME VERY ROUGH AT SEAL INTERFACE. FOUND LARGE GAPS IN SEAL AT LOWER GATE AREA. SMOOTHED & CONTOURED FRAME AREA, FILLED GAPS IN SEAL AT LOWER GATE.SDR CALA2013123194073Cover · missing4L CABIN ENTRY DOOR FWD GIRT BAR SWITCH SENSOR COVER MISSING. ACP INTERIM SWITCH COVER IAW ECRA 2566-01098.SDR CALA2013123094053Strap · unsecureDOOR 1R WILL NOT ARM FOUND STRAP LOOSE FROM SLIDE PACK JAMMING IT. STOWED LOOSE STRAP PROPERLY, PUT SLIDE COVER ON SECURELY, DOOR 1R ARMED NORMAL.SDR CALA2013123094052Seal · leakingDOOR 2L SEAL LEAKS UP TO ABOUT 10,000 FEET. SMOOTHED OUT PREVIOUS REM APPLICATION, PRESSURIZED CABIN IAW AMM NO AIR LEAKAGE DETECTED AROUND DR 2L.SDR CALA2013123094038Attach Bolt · looseFOUND FWD ATTACH BOLT LEAKING. NR 7 FLAP TRACK CLEANED & RESEALED ALL FOUR FWD ATTACH BOLTS AT NR 7 FLAP TRACK.SDR CALA2013123094015Frame · corrodedCORROSION ON FRAME AT STATION 1460 & STRINGER 27L. CORROSION OUT OF LIMITS. REPLACED FRAME IAW SRM 51-40-02 PARA 4 & 7 FIG 3, 6, 8 & 12 & DRAWING 146N1029 SHEET 3.SDR CALA2013123094014Door Frame · corrodedCORROSION AT AFT CARGO LOWER DOOR SILL FRAME. REPAIR DOUBLER BS 1435 IAW ECRA5360-013 57.SDR CALA2013123094040Compressor Blade · nickedNR 2 ENG FAN BLADE HAS LARGE NICK NEEDS TO BE PROPERLY DRESSED. BLENDED BLADES IAW AMM 72-31-02.SDR CALA2013123094013Skin · dentedFUSELAGE EXTERIOR SKIN DENTED AT STATION 570 - 580 & STRINGER 28R. REPAIR IAW ECRA 5331-01799.SDR CALA2013123094012Frame · corrodedCORROSION FOUND IN AFT PIT AT FRAME RBL 25 WL 147 & BS 1480R. R & R FRAME IN AFT PIT AT BS 1480, RBL 25 & WL 147 IAW SRM 51-40-02 FIG 8 & 12.SDR CALA2013123094010Light · inoperativeEMERGENCY EXIT LIGHT STRIP IN FRONT OF AFT LAVATORY INOPERATIVE. ONLY ONE LIGHT STRIP IN FRONT OF AFT LAVATORY INOPERATIVE, REST ILLUMINATE OK PARTS 560-0806 36262-4.SDR CALA2013123094008Feeder Cable · faultyEMERGENCY EXIT LIGHT FROM SEAT 37 - 40 & BY FWD AFT LAVATORY DOES NOT WORK. REPLACED FEEDER CABLE & LIGHT STRIP EMERGENCY EXIT LIGHT FROM SEAT 37-40 WORKS. THE STRIP BY THE AFT FWD LAVATORY DOES NOT WORK. DEFERRAL FOR LAST LIGHT ASSEMBLY MADE IAW MEL3351C.SDR CALA2013123094027Status Message · activatedPWR XFER UNIT STATUS MESSAGE. COMPLIED WITH MEL 3161B. PLEASE FOLLOW FIM 29-22-00, FIG 104 FOR TROUBLE SHOOTING PURPOSE.SDR CALA2013123094011Stringer · corrodedSTRINGER 29R AT STATION 1685 IS CORRODED IN INTERIOR CHANNEL, BS 1685, RBL 5 & STRINGER 29R. REPLACED STRINGER 29R IAW SRM 53-00-03 FIG 201 REPAIR MCN 34941.SDR CALA2013122793977Starter · faultyAPU INOPERATIVE 2 ATTEMPTS. SHOWS STARTER ON BITE CHECK. INSPECTED STARTER & FOUND BURNED OUT NEEDS MR49408. REPLACED APU STARTER MOTOR IAW AMM-49-41-01, OPERATIONS CHECKED OK.SDR CALA2013122793988Hydraulic Line · leakingON PUSHBACK DISCOVERED HYD LEAK RT AILERON. SECURED HYD RETURN HYD ACTUATOR SPOILER LINESDR CALA2013122793980Pump · faultyLT HYD ELEC PUMP LOW PRESS LIGHT ON WITH ITS CB POPPED. REPLACED LT ELEC IAW AMM 29-11-01. PRESS & CASE RETURN FILTER IAW AMM 29-11-18. OPERATIONS & PRESS CHECKED GOOD. SERVICED RESERVOIR TO FULL. REPLACED LT ACMP ELCU M10 001, RESET CB. OPERATION CHECK LSDR CALA2013122793979Processor · faultyFUEL QTY CHANNEL STATUS MESSAGE ON EICAS. REPLACED FUEL QTY PROCESSOR CHECKED GOOD.SDR CALA2013122793976Controller · faultyLT SIDE WINDOW EICAS CAME ON AGAIN. R & R LT WINDOW HEAT CONTROLLER, OPERATIONS CHECKED GOOD.SDR CALA2013122793975Fairing · damagedLT WING AILERON OTBD ACTUATOR FAIRING 56 1EB DAMAGED. ACCOMPLISHED INTERIM REPAIR TO THE LT AILERON OTBD FWD FAIRING IAW ITEM 100 IPC 57-51-1 1-001. SEAL HAS BEEN REMOVED IAW CDL ITEM DF469 CREATED. OPERATION CHECK OF AILERON ACCOMPLISHED IAW AMM 27-11-00-2SDR CALA2013122793978Hydraulic Line · looseFLUID LEAK UNDER RT WING NEAR FLAP TRACK OTBD OF ENG. FOUND NR 9 SPOILER LINE LOOSE. SECURED LINE THEN PRESSURIZED & LEAK STOPPED.SDR CALA2013122693938Skin · damagedEXTERNAL FUSELAGE SKIN EXTERNAL SURFACE HAS LIGHTNING STRIKE AT STATION 745 BETWEEN STRINGER 23R & 24R. REPAIRED IAW SRM 53-00-01 ALLOWABLE DAMAGE 1, DETAIL 1.
Back to Boeing 757-222