Boeing 757-223
Service difficulty reports · 8,750
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA961012Stub Frame · gougedAFW - FOUND NR 1 ENTRY DOOR HAS GOUGE BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-875. (M)SDR AALA961011Deck Plate · corrodedAFW - FOUND DECK PLATE CORROSION BEYOND SRM LIMITS. REPAIR PER MRB 757-871. (M)SDR AALA961010Door Sill · corrodedAFW - FOUND CORRODED LOWER SILL BEYOND SRM LIMITS. REPAIRED PER MRB 757-865. (M)SDR AALA961009Frame · crackedAFW - FOUND FUSELAGE FRAME CRACKED AT 524R. REPAIRED PER MRB 757-872. (M)SDR AALA961008Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 377 CORROSION BEYOND SRM LIMITS. REPAIR PER MRB 757-867. (M)SDR AALA961007Floor Beam · corrodedAFW - FOUND FLOOR BEAM CORROSION BLENDED BEYOND SRM LIMITS. REPAIR PER MRB 757-868. (M)SDR AALA960954Engine · flamed outLGA - FLT 732 - DURING DESCENT INTO LGA AT APPROXIMATELY 7000 FEET WITH POWER LEVERS AT IDLE, RIGHT ENGINE FLAMED OUT. ATTEMPTED RE-START SUCCESSFUL AND AIRCRAFT LANDED LGA WITHOUT INCIDENT. REPLACED RT ENGINE BVCU, TPU, IPG SOLENOID AND PLA TRANSDUCER. ACCOSDR AALA960903Deck Plate · corrodedAFW - FOUND DECK PLATE HAS CORROSION REMOVED IN VARIOUS LOCATIONS, CORROSION REMOVED IS BEYOND SRM LIMITS. PER MRB 757-855. (M)SDR AALA960902Sill · corrodedAFW - FOUND UPPER CHORD ON LOWER MAIN SILL, NR 2 CARGO DOOR CUTOUT HAS CORROSION REMOVED BEYOND LIMITS. PER MRB 757-862. (M)SDR AALA960901Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-860. (M)SDR AALA960900Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 324 HAS CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-861. (M)SDR AALA960899Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 365 RBL 61 HAD CORROSION BLENDED BEYOND SRM LIMITS. PER MRB 757-856. (M)SDR AALA960898Floor Beam · gougedAFW - FOUND FLOOR BEAM AT STATION 1600 LBL 13 HAD A GOUGE BLENDED BEYOND SRM LIMITS. PER MRB 757-857. (M)SDR AALA960856Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT SIDE MARKER LIGHT AT DOOR 2R INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT SIDE MARKER LIGHT AT DOOR 2R. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960868Pan · gougedAFW - FOUND L-4 DOOR PAN HAS GOUGE BLENDED BEYOND SRM LIMITS. PER MRB 757-844. (M)SDR AALA960867Floor Beam · corrodedAFW - FOUND FLOOR BEAM, AT STATION 365, HAS CORROSION REMOVED ON UPPER SURFACE, MATERIAL REMAINING IS BEYOND SRM LIMITS. PER MRB 757-845. (M)SDR AALA960866Floor Beam · corrodedAFW - FOUND ON UPPER SURFACE OF FLOOR BEAM, AT STATION 377, HAD CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-846. (M)SDR AALA960865Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 1640 HAD CORROSION REMOVED BEYOND SRM LIMITS AT LBL 37, 39, 40, 50 AND 55. PER MRB 757-848. (M)SDR AALA960864Deck Plate · corrodedAFW - FOUND DECK PLATE HAS CORROSION REMOVED IN VARIOUS LOCATION AREAS ARE BEYOND SRM LIMITS. PER MRB 757-849. (M)SDR AALA960840Fuel Governor · defectiveSJU - FLT 1470 - ON DESCENT TO SJU, THE NR 2 ENGINE WOULD NOT ADVANCE FROM IDLE POSITION. LANDED SJU WITHOUT INCIDENT. REPLACED NR 2 ENGINE FUEL GOVERNOR AND THROTTLE ANGLE TRANSDUCER. RAN ALL NECESSARY RUN-UP CHECKS. SYSTEM GROUND CHECKED, NORMAL OPERATIOSDR AALA960829Wire · failedMIA - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING IN FIRST CLASS SECTION TO COACH CLASS INOPERATIVE. REPAIRED WIRE SPLICE CONNECTOR AT COACH CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960821Air Distr · odorSFO - FLT 1376 - AFTER T/O SFO DURING INITIAL CLIMB-OUT, ELECTRICAL ODOR NOTED IN CABIN AND COCKPIT. A/C RETURNED TO SFO AND LANDED W/O INCIDENT. CHECKED OPERATION OF ALL PACKS AND CABIN/COCKPIT LIGHTING WITH NO DEFECTS FOUND. ACCOMP FUNCTIONAL CHECK FLT ANSDR AALA960810Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 345 HAS CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS, PER MRB 757-836. (M)SDR AALA960809Support · corrodedAFW - FLOOR PANEL SUPPORT AT STATION 345 AND BL 0 HAS CORROSION REMOVED ON UPPER SURFACE, MATERIAL REMAINING IS BEYOND SRM LIMITS, PER MRB 757-837. (M)SDR AALA960808Pan · gougedAFW - FOUND L-4 DOOR HANDLE PAN HAS A SMALL GOUGE, AFTER BLENDING AREA IS BEYOND SRM LIMITS, PER MRB 757-838. (M)SDR AALA960807Deck Plate · corrodedAFW - FOUND DECK PLATE HAS CORROSION REMOVAL ON UPPER SURFACE AT VARIOUS LOCATIONS. MATERIAL REMOVED IS BEYOND SRM LIMITS, PER MRB 757-839. (M)SDR AALA960806Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 365 HAS CORROSION REMOVED BEYOND SRM LIMITS, PER MRB 757-840. (M)SDR AALA960805Intercostal · corrodedAFW - FOUND INTERCOSTAL AT STATION 405 AND RBL 58 HAS CORROSION ON UPPER SURFACE, MATERIAL REMOVED IS BEYOND SRM LIMITS, PER MRB 757-841. (M)SDR AALA960804Pan · gougedAFW - FOUND R-4 DOOR HANDLE PAN HAS GOUGE BLENDED, AREA BLEND IS BEYOND SRM LIMITS, PER MRB 757-842. (M)SDR AALA960765Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS FROM PAX SEAT ROW 18F AND AFT INOPERATIVE. RESEATED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY PAX SEAT ROW 18F. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960750Deck Plate · corrodedAFW - FOUND DECK PLATE HAS SEVERAL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS, PER MRB 757-824. (M)SDR AALA960749Floor Beam · cutAFW - WHILE CUTTING THE TOP CAP OFF FLOOR BEAM 1640 FOR SRM REPAIR, EO WAS LOST ON THE 5 MOST OUTBOARD RIGHT FASTENERS AT FRAME, PER MRB 757-827. (M)SDR AALA960748Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 324 HAS CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMOVED IS BEYOND SRM LIMITS, PER MRB 757-819. (M)SDR AALA960747Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 345 HAS CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS, PER MRB 757-820. (M)SDR AALA960746Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 365 HAS CORROSION ON UPPER SURFACE BLENDED BEYOND SRM LIMITS, PER MRB 757-821. (M)SDR AALA960745Sill · corrodedAFW - FOUND LOWER MAIN SILL, UPPER CHORD, NR 2 CARGO DOOR CUTOUT HAS CORROSION REMOVED ON UPPER AND LOWER SURFACES. CORROSION REMOVED IS BEYOND SRM LIMITS, PER MRB 757-831. (M)SDR AALA960744Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVED BEYOND SRM LIMITS, PER MRB 757-826. (M)SDR AALA960743Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 377 HAD 6 AREAS OF CORROSION BLENDED BEYOND SRM LIMITS, PER MRB 757-822. (M)SDR AALA960713Connector · looseDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 6 THROUGH 17 INOPERATIVE. REINSTALLED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY PAX SEAT ROW 6. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960645Bleed Valve · defectiveLAX - FLT 421 - EN ROUTE DFW/SNA AT START OF DESCENT FROM FL 390 WITH ENG ANTI-ICE ON, POWER WAS REDUCED AND LT ENG EXPERIENCED FLAMEOUT. ACCOMP ENG SHUTDOWN AND ATTEMPTED RESTART WITH NO SUCCESS. A/C DIVERTED TO LAX AND LANDED W/O INCIDENT. REPLACED LT ENGSDR AALA960634Skin · puncturedAFW - FOUND LEFT MAIN LANDING GEAR DOOR OUTER SURFACE HAS PUNCTURE IN CRITICAL AREA. PER MRB 757-828. (M)SDR AALA960617Door Pan · gougedAFW - FOUND L-4 DOOR HANDLE PAN HAD GOUGE BLENDED BEYOND SRM LIMITS. PER MRB 757-818. (M)SDR AALA960608Wire · defectiveDFW - DURING OVERNIGHT CHECK, SHORT SECTION OF EMERGENCY FLOOR LIGHT AT MID-CABIN FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT FLAT CONDUCTOR WIRE AT MID-CABIN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA960641Surround Struct · corrodedAFW - FOUND AFT CARGO DOOR SURROUND STRUCTURE UPPER CHORD HAS CORROSION BLENDED OFF BEYOND SRM LIMITS. PER MRB 757-783. (M)SDR AALA960640Pan · gougedAFW - FOUND R-4 DOOR HAS A SMALL GOUGE AFTER BLENDING. BLENDED AREA IS BEYOND SRM LIMITS. PER MRB 757-775. (M)SDR AALA960639Pan · gougedAFW - FOUND L-4 DOOR HANDLE PAN HAS A GOUGE BLENDED BEYOND SRM LIMITS. PER MRB 757-781. (M)SDR AALA960638Floor Beam · misdrilledAFW - FLOOR BEAM AT STATION 345 LBL HAS A MISDRILLED HOLE. PER MRB 757-788. (M)SDR AALA960637Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION REMOVAL ON UPPER SURFACE MATERIAL REMAINING AT VARIOUS LOCATIONS ARE BEYOND SRM LIMITS. PER MRB 757-779. (M)SDR AALA960636Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVED AT VARIOUS LOCATIONS MATERIAL REMOVED IS BEYOND SRM LIMITS. MRB 757-778. (M)SDR AALA960635Floor Beam · corrodedAFW - FLOOR BEAM AT STATION 324 RBL 42 AND RBL 62 HAS CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-777. (M)
Back to Boeing 757-223