Boeing 757-224
Service difficulty reports · 3,821
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025100309578None · noneRIGHT OVERWING SLIDE DEACTIVATED AND PANELS OPENED. IAW AMM - 25-65-00-002-001. RIGHT OVERWING SLIDE REACTIVATED AND CLOSED PANELS. ARMED RT OVER WING SLIDE REF AMM 25-65-00. VERIFIED RH OVER WING SLIDE REACTIVATED AND ARMED PER RII REQUIREMENTSSDR CALA2025100209554Lanyard · loose4L DOOR WILL NOT ARM.. VISUALLY INSPECTED AND FOUND LANDYARD LOOSED. RESECURED LANDYARD AND OPS CHECKD DOOR IN REF AMM 52-13-00. DOOR OK FOR SERVICESDR CALA2025100209548Indicator · out of positionR1 SLIDE ARM LIGHT IS OUT OF PLACE, R1 SLIDE ARM LIGHT ON DEFERAL. DDP COMPLIED WITH. APPROVED AC OK TO CONTINUE ON 2566R KNUCKLE KNOCKER OPS NORMAL. DM ADDED LIGHT (L404) IF NEEDED. REF WDM 25-66-11-1. REPLACED SLIDE LIGHT PER WDM 25-66-11-1. OPS CHECK GOOD.SDR CALA2025100209522Toilet · odorLAVATORY TOILET BOWL SMELLS BAD AT DR-1L FWD CABIN LAV A. REMOVED TOILET SHROUD NO LEAK DETECTED, SERVICED LAV A TWICE, CLEANED TRASH CAN AND CLEANED LAV A .SDR CALA2025100209521None · noneLIQUID OF UNKNOWN ORIGIN ALL ALONG RIGHT SIDE COCKPIT FLOOR. STRONG COFFEE SMELL ALSO. FLIGHT CREW SPILLED COFFEE DURING FLIGHT. SPILLAGE MOSTLY DRY UPON ARRIVAL. INSPECTED E+E NO FLUIDS FOUND.SDR CALA2025100209520Potable Water · odorSTRONG ODOR IN POTABLE WATER AND LAV WATER, PERFORMED POTABLE WATER SYSTEM DISINFECTION IAW JC B757-MP-6700-38-001-00SDR CALA2025100609640Intercostal · crackedWHILE PERFORMI ING REPAIR FOR NRTN 1333882 DISCOVERED CRACK COMMON TO MATING 14 6N5425-37 INTER COSTAL WEB. REMOVE WEB, REMOVE STIFFENERS COMMON TO WEB, FABRICATE WEB LOCATE DRILL TREAT PRIME REINSTALL ESDR REPORTING REMOVED 02 STIFFENERS AND 02 CLIPS FROM INSDR CALA2025100609639Intercostal · gougedMAIN E&E ACCESS DOOR CUTOUT BETWEEN FR460- FR480/S29R INTERCOSTAL I/B SURFACE GOUGED. DIT 95-15. REMOVED AND REPLACED INTERCOSTAL AT MAIN E&E ACCESS DOOR CUT OUT BETWEEN FR460-FR480 S21R.SDR CALA2025100609638Plate · crackedNR 2 ENGINE, UPPER STRUT GAP PANEL LE CRACKED. REMOVED, FABRICATED AND REPLACED GAP PANEL SKIN IAW SRM 51-40-02 AND PER PRODUCTION CONTROL TRAVELER T25/1832479 SDR 200 4.SDR CALA2025100309590Strap · corrodedDURING REMOVAL APU INLET DOOR, FOUND AFT CUTOUT STRAP WITH CORROSION (MARKED IN RED). DOT 34-024. REFERENCE N/R 134237 ESFR ENTRY REMOVED/REPLACED 2 EACH APU CUTOUT STRAPS FILLERS IAW SRM 53-80- 15-2R-1 PARTS FABRICATED IAW SRM 53-80-15-2R-1 TAB 201/202 DETAI SDR CALA2025093009446Warning Message · false activationTE FLAPS DISAGREE CAUTION MSG FSEU 1 LAST LEG HAD FAULT 305 - INTERMITTENT, FSEU 2 HAD FAULT 327. PERFORMED FIM 27-51 TREE 805, BITE TEST GOOD, NO EXISTING FAULTS. MSG CLEARED. CYCLED FLAPS THROUGH FULL TRAVEL MULTIPLE TIMES, FLAPS OPERATED NORMALLY.SDR CALA2025092909379Intercostal · corrodedEA 5311-02748 REV A - STA 1380 FWD FRAME INSP WHILE PERFORMING TASKS IAW EA 5311-02748 REV A STA 1380 FOUND CORROSION COMMON TO INTERCOSTAL WEB BETWEEN STA 1360-1380. REMOVED IAW SRM 51-40-02-06 STA 1366 TO 1380, FOUND TO BE OUT OF LIMITS PER CORROSION EXFOLSDR CALA2025092809342Toilet · odorLAVATORY TOILET BOWL SMELLS BAD AT DR-1L FWD-CAB LAV A CLEANERS AND LAV SERVICE NOTIFIED FOR FLUSH AND CLEANING. TANK DISINFECTANT TABS PLACED INSPECTED LIFEVEST CONTAINER, STOWED LIFE VEST, AND SEALED COMPARTMENT AT NOTED LOCATIONS TANK.SDR CALA2025093009423Proximity Sensor · stickingSLIDE LIGHT OVER 2R ILLUMINATED ON GROUND WILL NOT EXTINGUISH DOOR SLIDE ARMED LIGHT STAYS ILLUMINATED WHEN DOOR IS DISARMED. LIGHT EXTINGUISHES WHE DOOR HANDLE IS MOVED TO THE OPEN POSITION, LIGHT ILLUMINATES WHEN DOOR IS CLOSED AND DISARMED. VERIFIED GIRT SDR CALA2025092409219Doubler · not reportedREPAIR FOUND ON LEFT FUSELAGE APPROX LOCATION OF BS 1787.45 + 27.5 TO BS 1830 LOCATED OVER LT HORIZONTAL STAB ABOUT 10" DOWN FROM VERTICAL STAB.REQUIRES REPLACEMENT DUE TO NO DOCUMENTATION OR DIP INFO FOR REP INSPECTIONS. REMOVED AND REPLACED DOUBLER STA 1787.SDR CALA2025092409216Skin · nickedLEFT FUSELAGE AFT STATIC PORT CABIN PRESSURE HAS EVIDENCE OF SMALL NICKS. REPAIRED PER ECRA 5360-02022.SDR CALA2025092409205Bottle · no discrepancyDOOR 2L SLIDE GAUGE IN THE RED PAST THE GREEN BAND. INSPECTED INFLATION CYLINDER ON DOOR 2L REF AMM 25-66-01-206-024, NEEDLE IS NOT MORE THAN HALF THE WIDTH OFF THE GREEN MARKER, PRESSURE REMAINS STABLE. OK FOR SERVICE.SDR CALA2025092309168Power Supply · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCH PROCEDURE, EMERGENCY LIGHT ABOVE ROW 11 DEF INOPERATIVE. REPLACED THE LAMP AISLE EMERGENCY LIGHT ABOVE SEATS 11 DEF IAW AMM 33-51-05. NO HELP. R & R AISLE EMERGENCY LIGHT HOUSING ASSEMBLY AT SEAT 11 DSDR CALA2025100909831Channel · corrodedAFT CARGO BAY, BS 1300 RT SIDE BRACKET SUPPORT ATTACHED IN THE FRAME FOUND WITH CORROSION. REMOVED AND REPLACED ONE CHANNEL IAW SRM 51-40-02-0G -1, VIA T25/1832218.SDR CALA2025100909830Channel · crackedTWO CRACKS FOUND ON LT WHEEL WELL DOOR SEAL SUPPORT CHANNEL BS 1060, LBL 50. REMOVED AND REPLACED 149N7550-95 VIA T25/831393 IAW SRM 51-40-02 -0G-1 RESTORED SURFACE PROTECTION IAW SRM 51-20-01-0G AND AMM 5 1-21-15.SDR CALA2025092309159Girt Bar · out of adjustR1 DOOR WILL NOT ARM. ADJUSTED GIRT BAR MECHANISM OF THE SLIDE RAFT. ACCOMPLISHED IAW AMM SUB TASK 25-66-10-712-031. CYCLED ARM LEVER DOOR OPENED/CLOSED PROPERLY IS TIME.CHECK GOOD.SDR CALA2025100309600Handle · gougedAFT CARGO DOOR EXTERNAL OPENING HANDLE INNER SURFACE GOUGED. AFT CARGO COMPARTMENT DOOR HANDLE HAD GOUGE THAT EXCEEDED MANUFACTURES LIMITS. REPAIRED PER EC/RA 5320-02296.SDR CALA2025092409239Indication Sys · false indicationLEFT ENGINE HIGH VIBRATION INDICATION. DEGRADED ENGINE, DID NOT SHUTDOWN. CAPT ADVISED: CLIMBING THRU 32K TO 36K AND SLOWING DOWN A BIT THROUGH SOME MODERATE TURBULENCE, LOOKED DOWN AND SAW VIBRATION INDICATON IN THE AMBER FOR N1, N2, AND N3. FELT NOTHING & SDR CALA2025092309156Skin · gougedFWD CARGO DOOR EXTERNAL OPENING HANDLE INNER SURFACE GOUGED. GOUGE OUT OF MANUFACTURES LIMITS, REPAIRED IAW ECRA 5230-02295.SDR CALA2025092509278Pressure Switch · faultedRIGHT HYDRAULIC SYS EICAS & BRAKE SOURCE EICAS ON, WITH NORMAL SYS QTY & PRESSURE. CREW REPORTS BRAKE SOURCE LIGHT INFLIGHT WITH CORRESPONDING RT HYDRAULIC PRESSURE LIGHT. CREW NEVER NOTICED A RT HYD QTY DROP. TURNING OFF RT SIDE ENGINE PUMPS & RE-ENGAGING SDR CALA2025092209115Accelerometer · faultedLEFT ENGINE N3 VIB WENT TO 5.0 /AMBER/ TWICE FL380 .78 REDUCED T HRUST N3 STABLE AT .8 AS PART OF OTHER TROUBLESHOOTING, REPLACEMENT OF THE #1 ENG AVM HAS BEEN CARRIED OUT, REF AMM 77-31-04-404-017, OPERATIONAL CHECK OK.ACCELEROMETER REPLACED, AND OPERATIONAL SDR CALA2025091909063Girt Bar · fodDOOR 1R NOT ARMING, REMOVED DEBRI BETWEEN GIRT BAR AND FLOOR. PERFORMED OPS CK PER AMM 52-11-00, OPS CK GOODSDR CALA2025091809024Skin · dentedFUSELAGE BTWN BS 600 - 620 S16L. EXISTING REPAIR DOUBLER HAS A DENT. COMPLIED WITH UAL ECRA 5330-07610 AND V T MAE EA 757-5330-13-A41 09 REV-.SDR CALA2025091909045Antenna · failedON CLIMBOUT WX RADAR FAIL BOTH SIDES AND WX SYS STATUS MSG OBSERVED. REPLACED LT WX RADAR TRANSCEIVER IAW AMM 34-43-01. OPS CHECK FAILED. PERFORMED WX RADAR OPS AND SYS TEST. TEST FAILED WITH FAULT WXR RT ANT . REQUIRES REPLACEMENT OF WX RADAR ANTENNA. IAW SDR CALA2025091809019Channel · dentedAFT CARGO LT SIDE AT BS 1300 CLOSE TO TRANSITION PANEL SUPPORT BRACKET IN THE FRAME WITH DENT AND CORROSION. PANEL SUPPORT(CHANNEL) WAS REMOVED I.A.W B757-200 SRM 51-40-02, RECEIVED NEW CHANNEL TRAVELER T25/1832217, L OCATED AND DRILLED NEW CHANNEL IAW SRM 51SDR CALA2025091708996Web · damagedNR 1 ENGINE TOP OF PYLON HYDRAULIC LINE BRACKET WORE INTO BOW TIE STRAP ON TOP OF PYLON. REPAIRED UPPER PLYLON WEB REF ECRA 5450-03044.SDR CALA2025091608982Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCH PROCEDURE - L4 EXTERIOR EMERGENCY LIGHT INOP. RELAMPED LIGHT AND OPS CHECK GOOD W/REF AMM 33-51-00.SDR CALA2025091608965None · no discrepancy4R SLIDE PRESSURE IN THE RED. PRESSURE GAGE NEEDLE ON THE SLIDE INFLATION CYLINDER ON DOOR 4R IS IN THE GREEN BAND OR NOT MORE THAN 1/2 THE PRESSURE GAGE NEEDLE WIDTH ABOVE OR BELOW THE GREEN BAND AS PER AMM TASK 25-66-01-206-024. OK TO CONTINUESDR CALA2025091508875Fuse · inoperativeEMERGENCY LIGHTS, OPERATIONAL TEST WITH THE TEST SWITCH PROCEDURE, DOOR 3R EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY FUSE IAW AMM 33-51-07-962-071 OPS CHECKED GOOD. REPLACE LIGHT ASSEMBLY AS REF. AMM 33-51-06-962-049-001.SDR CALA2025091508869Bulb · failedRH EMERGENCY EXIT HATCH . EXIT LIGHT INOP REPLACED RH EMERGENCY EXIT HATCH EXIT LIGHT BULB REF AMM 33-51-00/201 OPS CHECK GOOD.SDR CALA2025091508894Girt Bar · fodDOOR 4R SLIDE LIGHT INOPERATIVE. REMOVED DEBRIS FROM GIRT BAR AREA. SLIDE LIGHT OPS NORMALSDR CALA2025091108786Light · detachedEMER EXIT SIGN MID CABIN IS DETATCHED AND FALLING OFF THE CEILIN G SECURED LIGHT OPS CHECKS GOODSDR CALA2025091108783Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCH PROCEDURE - DOOR 1L EXTERIOR EMERGENCY LIGHT INOP REPLACED THE L1 DOOR EMERGENCY EXTERIOR SLIDE LIGHT REF AMM 33-51-06-962-001-001 OPS CK GOODSDR CALA2025091108781Lamp · inoperativeINOP SLIDE LIGHT IS ON DOOR 3R. REPLACED 3R SLIDE LIGHT OPS CHECK GOOD IAW AMM 33-51-06.SDR CALA2025091108775Support · crackedNLG W/W, LT SIDE, MAIN DOOR CUTOUT HAS A CRACK AROUND A FASTENER, NEAR BS 324. REMOVED SUPPORT MAIN DOOR CUTOUT NLG W/W, LT SI DE IAW SRM 51-40-02-G-0. FABRICATED NEW SUPPORT IAW SRM 51-40-05-0G-0, SRM 51-30-01-0G-0, AND DWG 141N0094. TREATED & PRIMED IAW SDR CALA2025091108774Support · crackedNLG W/W, RH SIDE, MAIN DOOR CUTOUT HAS A CRACK AROUND A FASTENER, NEAR STA 324. REMOVED SUPPORT P/N 141N0094-99 MAIN DOOR CUT OUT, NLG W/W RH SIDE IAW SRM 51-40-02-0G-0. FABRICATED NEW SUPPORT IAW SRM 51-40-05-0G-0, SRM 51-31-01-0G-0 AND DWG 141N0094. TREATEDSDR CALA2025091008728Wire · burnedMAIN EQUIPMENT CENTER AT BS 395 RT UPPER POWER FEEDER IS BURNED. REMOVED AND REPLACED POWER FEEDER WIRE W3412-0003-210 AND W3412- 0010-210 IAW WDM 24-21-21 AND SWPM 20-10-21 21-30-13 AND 20-10-20 T97654 OPS CHECK OK IAW AMM 71-00-00-795-032 -R03.SDR CALA2025091008724Wire Harness · burnedREF EA3611-01469. ENGINE 2 STRUT, UPPER SURFACE, RH SIDE, BY STA PPS 174.30, WIRE BUNDLE HAS CHAFING AND BURN MARKS. ESDR COMPLETED. REMOVED AND REPLACED POWER FEEDER WIRE W3412-0006-110 ON ENG #2 IAW AND M 24-21-21 AND SWPM 20-10-11 AMM 24-11-20-404-01 2 T011SDR CALA2025091108818Slide · dislodgedL4 DOOR SLIDE DROPPED OFF THE DOOR BUT DID NOT DEPLOY. DOOR L4 WAS OPENED FROM INSIDE AFTER THE OPENING FROM THE OUTSIDE WAS NOT SUCCESSFUL. DOOR WAS ARMED AND THE SLIDE GIRT BAR WAS INSTALLED. SLIDE DID NOT DEPLOY DUE TO SLIDE ASSEMBLY FALLING ONTO CATERINGSDR CALA2025090808587Bulkhead Web · gougedAFTER RADOME HOLD SUPPORT BRACKET REMOVED, FOUND A GOUGE A T BULKHEAD FRONT FACE SKIN BS 200 LBL 15. ACCOMPLISHED REPAIR ON FWD BULKHEAD FRONT FACE SKIN WITH NO DEVI ARIOUS PER VT MAE EA 757-5310-13-A4089 REV- AND EC/RA #5310-0868 9. DIP BY PAGES CREATED PERSDR CALA2025090908655Line · tangledCANNOT ARM 1L DOOR L1 STATIC LINE GOT CAUGHT BETWEEN DOOR SILL AND GIRT BAR. UNTANGLED AND RESTOWED STATIC LINE. ARMED LIGHT ILUMINATES, OK TO CONTINUE. REF AMM 25-66-10-402-022. ADD 347373, U345365SDR CALA2025090808588Light · faultedCABIN EMERGENCY LIGHTS INOP FROM ROW 32 TO THE LAST ROW. SWAPPED BATTERIES FROM M736 & M737, NO HELP. REPLACED FUSES ON BATTERY PACK M737 AND REPLACED POWER SUPPLY IAW FIM TASK 33-51 FAULT TREE 802. LIGHTS IN ROWS MENTIONED COME ON INITIALLY WHEN SWITCHED EISDR CALA2025090808582Handle · wornL1 ENTREY DOOR UNABLE TO OPEN DOOR BY THE EXTERIOR HANDLE REMOVED L1 DOOR HANDLE ASSY, REPLACED CAM BASKET AND WORN HANDLE PARTS REF AMM 52-11-13SDR CALA2025090808557Lavatory · leakingBLUE FLUID LEAKING & PUDDLING ON FLOOR AROUND MID LAV. FOUND BLUE FLUID TO BE IN & AROUND TOILET CAVITY, FOUND EVIDENCE OF BLUE FLUID LEAKING IN MULTIPLE SPOTS OF FWD CARGO PIT, STRONG SMELL OF BLUE JUICE, REMOVED MID LAV TOILET SHROUD ALL CARPET IN ENTIRESDR CALA2025090808600Retainer · inoperativeFA REPORTS DOOR 4L SLIDE HOUSING DISLODGED GIRT BAR RETAINING CLIP BENT ON FORWARD PART OF GIRT BAR. DOES NOT ALLOW GIRT BAR TO SECURE PROPERLY. REMOVED AND REPLACED GRIT BAR AT DOOR 4L IAW AMM 25-66-10/201, ESCAPE SLIDE RENDER SAFE CHECKLIST COMPLETED.
Back to Boeing 757-224