Boeing 757-224

Service difficulty reports · 3,824

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '757224'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR CALA2017071402231Sensor · dirtyR1 DOOR SLIDE INDICATOR SHOWS ARMED EVEN THOUGH THE DOOR IS DISARMED.. CLEANED THE SENSORS AND VERIFIED CORRECT GAP. SLIDE LIGHT AND ARMING OPERATES NORMAL IAW AMM 25-66-11, AND FIM 25-66-00.Jul 14, 2017 · N13110 · Boeing 757224 · Emergency EquipmentSDR CALA2017071402218Liner · failedGALLEY GALLEY G4A OVEN SMOKING. LINER FAILURE ON OVEN. R & R THE OVEN. OPS CHECKED GOOD.Jul 14, 2017 · N17133 · Boeing 757224 · Cabin Equipment/FurnishingsSDR CALA2017071402217Acm · odorAT BEGINNING DESCENT FL3 30- WHEN THROTTLES WENT TO IDLE, HAD AN ODOR. R & R THE RT AIR CYCLE MACHINE IAW AMM 21-51-03-404-018. OPS AND LEAK CHECKED NORMAL.Jul 14, 2017 · N14121 · Boeing 757224 · Cabin Cooling SystemSDR CALA2017071402194Floorbeam · corrodedCORROSION ON MAIN CABIN TOP OF FLOORBEAM TEE CAP AT MULTIPLE LOCATIONS, BS 720 BETWEEN BL 0 - RBL 45. REMOVED AND REPLACED THE TEE IAW SRM 51-40-02 PAR 4, 7, AND FABRICATED A NEW TEE IAW DWG 95-030, REV A.Jul 12, 2017 · N19117 · Boeing 757224 · Fuselage Main, Floor BeamSDR CALA2017071402193Floor Support · corrodedCORROSION AROUND FASTENER HOLES ON THE MAIN CABIN FLOOR SUPPORT BETWEEN BS 1660 TO 1675. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT IAW SRM 51-40-02 7D(6), AND SRM 51-40- 02 (4).Jul 12, 2017 · N19117 · Boeing 757224 · Fuselage Miscellaneous StructureSDR CALA2017071402192Floor Support · corrodedCORROSION ON THE MAIN CABIN FLOOR SUPPORT BETWEEN BS1665 TO 1675, LBL.56. THE FLOOR SUPPORT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DET 3. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, PAR 4, AND 7.Jul 12, 2017 · N19117 · Boeing 757224 · Fuselage Miscellaneous StructureSDR CALA2017071002160Cover · detachedEMERGENCY EXIT LIGHT COVER AT THE L2 DOOR IS DETACHED. ATTACHED THE COVER IAW AMM 33-51-00.Jul 10, 2017 · N14121 · Boeing 757224 · Emergency LightingSDR CALA2017071002159Cover · looseEMERGENCY EXIT SIGN NEXT TO SEAT 21A WILL NOT STAY ATTACHED TO THE WALL. R & R THE EMERGENCY EXIT SIGN COVER.Jul 10, 2017 · N14120 · Boeing 757224 · Emergency LightingSDR CALA2017071002158Lamp · inoperativeRIGHT OVERWING EMERGENCY LIGHT ABOVE HATCH HAS 9 BULBS BURNED OUT. REPLACED THE LAMPS, OK TO CONTINUE.Jul 10, 2017 · N12116 · Boeing 757224 · Emergency LightingSDR CALA2017071002157Girt Bar · damagedFOUND R4 DOOR GIRT BAR DAMAGED DURING SLIDE REPLACEMENT. REMOVED AND REPLACED THE GIRT BAR IAW AMM 52-11-25. OPS CHECKED GOOD.Jul 10, 2017 · N14115 · Boeing 757224 · Emergency EquipmentSDR CALA2017071002125Channel · crackedCHANNEL CRACKED ON TOP AROUND BOTH NUTPLATES AT BS 350, RBL 24. REMOVED & REPLACED THE CHANNEL.Jul 10, 2017 · N19117 · Boeing 757224 · Fuselage Miscellaneous StructureSDR CALA2017071002124Floor Support · corrodedCORROSION ON THE MAIN CABIN FLOOR SUPPORT BETWEEN BS 702 & 720, RBL 64.5 UPPER SURFACE. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, PAR 4, FIG 8.Jul 10, 2017 · N19117 · Boeing 757224 · Fuselage Miscellaneous StructureSDR CALA2017071002139Oven · overheatedOVEN 413 AFT GALLEY OVERHEATED AFTER 15 MINUTES, SETOFF SMOKE ALARM IN LAVATORY. R & R THE OVEN. OPS CHECKED GOOD.Jul 10, 2017 · N19141 · Boeing 757224 · Buffet/GalleysSDR CALA2017071002138Filter · odorDURING TAKEOFF, SMELLED FUMES FOR 5 MINUTES. FLIGHT CREW INDICATED NO FUMES. IAW AMM 05-51- 58-910-801C1 REMOVED AND REPLACED BOTH LEFT AND RIGHT HEPA RECIRCULATION FILTERS IAW AMM 21-25-02. NO OTHER DEFECTS FOUND. OK TO CONTINUE.Jul 10, 2017 · N33132 · Boeing 757224 · Air Distribution SystemSDR CALA2017071002137Unknown · odorA NOTICEABLE OIL LIKE ODOR DURING DESCEND WITH NO VISUAL SIGNS OF ANY SMOKE. ENGINE OIL TANKS FOUND FULL, NO HYDRAULIC LEAKS NOTED ON ENGINE. RAN APU AND PACKS, NO ODORS NOTICED. ALL INTERIOR LIGHTING ON, NO ODORS OBSERVED.Jul 10, 2017 · N14121 · Boeing 757224 · Air Distribution SystemSDR CALA2017071002132Unknown · odorFUMES IMMEDIATELY AFTER TAKE OFF, NOTICED IN COCKPIT AND MID CABIN. CHEMICAL ODOR.CLEARED 10 MINUTES LATER. FINISHED INSPECTION AND OPERATIONAL CHECKS. NO DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICEJul 10, 2017 · N33132 · Boeing 757224 · Air Distribution SystemSDR CALA2017071002131Unknown · odorFLIGHT ATTENDANTS REPORTED A BAD ODOR DURING DESCENT. HEAVY FUMES AFFECTING PAX AND CREW. TROUBLESHOT IAW FIM 71-05-00-815-828-R00. BORESCOPED THE NR 1 ENGINE, FOUND NO EVIDENCE OF OIL. RAN THE NR 1 & 2 ENGINES AT DIFFERENT POWER SETTINGS WITH BLEEDS OF EJul 10, 2017 · N14121 · Boeing 757224 · Air Distribution SystemSDR CALA2017071002122Pressure Deck · corrodedDOUBLER ON UPPER SURFACE OF AFT PRESSURE DECK HAS CORROSION ON UPPER SURFACE BS 1680, BL 0. REMOVED, FABRICATED, LOCATED, DRILLED & INSTALLED THE DOUBLER ON AFT PRESSURE DECK IAW SRM 51-40-02, PARA 4, FIG 328, & 53-60-51, REPAIR 2.Jul 9, 2017 · N19117 · Boeing 757224 · Fuselage Main, BulkheadSDR CALA2017070902117Filter · odorSTRONG ODOR AFTER APPLYING POWER FOR TAKEOFF. ODOR CONTINUED THROUGH 15000 FT. REMOVED AND REPLACED THE RECIRCULATION FILTERS IAW AMM 21-25-02. OPS TESTED IAW AMM 21-25-00. CHECKED NORMAL.Jul 9, 2017 · N14121 · Boeing 757224 · Air Distribution SystemSDR CALA2017070802113Oven · smokeGALLEY OVEN 411 INOPERATIVE, SMOKE WHEN USED. R & R THE AFT GALLEY OVEN IAW AMM 25-34-00, OPS CHECKED OK.Jul 8, 2017 · N17122 · Boeing 757224 · Buffet/GalleysSDR CALA2017070302090Apu · leakingDIRTY SOCK ODOR DURING TAKEOFF FOR 30 SECONDS, ACCOMPLISH FIM TASK 21-00-01, PAGE BLOCK 301. EXAMINED THE COOLING PACKS FOR OIL CONTAMINATION. FIM TASK 21-00-01 PAGE BLOCK301 CARRIED OUT .OIL FOUND POOLING IN APU SERVICE BAY, BAY CLEANED AND LEAK CHECK CARRJul 3, 2017 · N14107 · Boeing 757224 · APU Oil SystemSDR CALA2017070302094Guard · faultyEMERGENCY LIGHT SWITCH ON OVERHEAD PANEL DOES NOT MOVE TO ARMED POSITION WHEN GUARD IS CLOSED. REPLACED THE SWITCH GUARDJul 3, 2017 · N57111 · Boeing 757224 · Emergency LightingSDR CALA2017070102067Unknown · odorSTRONG ODOR IN FIRST CLASS CABIN, COMING FROM VENTS. ESPECIALLY BAD ROWS 2-4. NO EVIDENCE OF ODOR DETECTED COMING FROM THE VENTS ONCE ACFT LANDED. Jul 1, 2017 · N14121 · Boeing 757224 · Air Distribution SystemSDR CALA2017063002033Lamp · inoperativeEXTERIOR EMERGENCY LIGHT LEFT AND RIGHT SIDES AFT SECTION PARTIALLY INOPERATIVE. REPLACED THE LAMPS AND OPS CHECKED NORMAL IAW AMM 33-51-01, AND 33-51-00.Jun 30, 2017 · N34137 · Boeing 757224 · Emergency LightingSDR CALA2017063002032Bulb · inoperativeRIGHT INTERIOR OVERWING EMERGENCY FWD & AFT EXIT SIGNS HAVE MULTIPLE BULBS OUT. REPLACED THE BULBS. OPS CHECKED GOOD.Jun 30, 2017 · N19136 · Boeing 757224 · Emergency LightingSDR CALA2017063002031Smoke Goggles · wornFIRST OBSERVER`S SMOKE GOGGLES STRAP ELASTICITY IS WORN OUT. UNABLE TO TIGHTEN FURTHER. REPLACED THE SMOKE GOGGLES.Jun 30, 2017 · N14115 · Boeing 757224 · Emergency EquipmentSDR CALA2017063002034Bulb · inoperativeAFT LEFT OVERWIMG EMERGENCY LIGHT INOPERATIVE. REPLACED THE BULB. OPS CHECKED GOOD.Jun 30, 2017 · N17139 · Boeing 757224 · Emergency LightingSDR CALA2017063002035Bulb · inoperativeEMERGENCY EXIT LIGHT OVER SEAT 1E INOPERATIVE. REPLACED THE BULB. OPS CHECKED GOOD.Jun 30, 2017 · N17139 · Boeing 757224 · Emergency LightingSDR CALA2017063002022Relay · failedAT FL370. HAD ELECTRICAL SURGE WITH A SLIGHT ACRID ODOR ALONG WITH SIMUL EICAS R RECIRCULATION FAN RT FWD WINDOW. FOUND UTILITY BUSS RELAY K120 WITH BURN DAMAGE BEHIND P37 CB PANEL. FOUND WIRES W1270-0084-18, W1272-0076-12, W1272-0065-12 WITH BLACKENED INSULAJun 30, 2017 · N34131 · Boeing 757224 · Electrical Power System WiringSDR CALA2017063002007Oven · odorAFT GALLEY OVEN 411 HAD BURNING ELECTRICAL ODOR AFTER TURNING ON. REMOVED AND REPLACED OVEN AT 411,OPS CHECK O.K.Jun 30, 2017 · N48127 · Boeing 757224 · Buffet/GalleysSDR CALA2017062601996Girt Bar · dirtyDOOR 4R SLIDE ARMED LIGHT WILL NOT ILLUMINATE. CLEAN GIRT BAR AND AREA. CHK OPS FOR ARM AND DISARM PER AMM 25 -66-001. OPS CHK NORMAL.Jun 26, 2017 · N19136 · Boeing 757224 · Emergency EquipmentSDR CALA2017062501978Oven · odorGALLEYS GALLEY G4A OVEN AUTO STOPS DURING COOKING, FAULT 6 DISPLAYED, FAINT ELECTRICAL ODOR. FOUND NR 1 OVEN INOPERATIVE. REMOVED AND REPLACED THE OVEN, OPS CHECKED GOOD IAW AMM 25-34-00Jun 25, 2017 · N18119 · Boeing 757224 · Buffet/GalleysSDR CALA2017062301955Proximity Sensor · failedL4 DOOR SLIDE ARM LIGHT INOPERATIVE. FOUND THE GIRT BAR PROXIMITY SWITCH BAD. REPLACED THE PROXIMITY SWITCH IAW AMM 25-66-11. OPS CHECKED GOOD.Jun 23, 2017 · N34131 · Boeing 757224 · Emergency EquipmentSDR CALA2017062301954Cover · missingEXIT ROW SEAT 21F EXIT SIGN COVER IS MISSING. INSTALLED THE COVER AS REQUIRED.Jun 23, 2017 · N17126 · Boeing 757224 · Emergency LightingSDR CALA2017062301953Cover · detachedEMERGENCY EXIT SIGN COVER AT ROW 21 ABC FELL OFF AND WAS LAYING IN SEAT. I NSTALLED THE COVER. NO FURTHER ISSUESJun 23, 2017 · N14120 · Boeing 757224 · Emergency LightingSDR CALA2017062301938Floorbeam · corrodedFLOORBEAM TOP SURFACE CORRODED, BS 720, RBL 25-45. ACCOMPLISHED A FLOORBEAM REPAIR IAW EC/RA 5310-05536, TABLE II, PG 3.Jun 23, 2017 · N34137 · Boeing 757224 · Fuselage Main, Floor BeamSDR CALA2017062301936Support Fitting · corrodedFWD CARGO DOOR CUTOUT SUPPORT FITTING HAS CORROSION AT FWD LOWER CORNER. REMOVED AND REPLACED THE SUPPORT FITTING IAW SRM 51-40-02.Jun 23, 2017 · N34137 · Boeing 757224 · Fuselage Miscellaneous StructureSDR CALA2017062301926Web · corrodedCORROSION FOUND ON AFT WET AREA WEB BS 1706, LBL 5. REMOVED CORROSION IAW AMM 51-00-53, FOUND AREA OUT OF LIMITS AND FOUND A HOLE CRACKED, OVERSIZE HOLE IAW EC/RA 53330/04259, STEP 3, II. FABRICATED A DOUBLER REPAIR, LOCATED, DRILLED, TREATED AND PRIMED AJun 21, 2017 · N34137 · Boeing 757224 · Fuselage Miscellaneous StructureSDR CALA2017062301925Support Fitting · corrodedFWD CARGO DOOR CUT OUT SUPPORT FITTING HAS CORROSION AT FWD LOWER CORNER. REMOVED AND REPLACED THE SUPPORT FITTING IAW SRM 51-40-02.Jun 21, 2017 · N34137 · Boeing 757224 · Fuselage Miscellaneous StructureSDR CALA2017061901907Flashlight · not seated1R EMERGENCY FLASHLIGHT INOP. RESEATED EMER FLASHLIGHT AT FWD FLT ATTENDANT STATION, FWD GALLEY, OPS CHK GOOD REF AMM 25-64-00.Jun 19, 2017 · N33132 · Boeing 757224 · Emergency EquipmentSDR CALA2017061901905Light · dirtyDOOR 1R SLIDE ARMED LIGHT BULB INOP. REMOVED IT AND CLEANED IT, CHECKED GOOD. A/C OK TO CONT.Jun 19, 2017 · N57111 · Boeing 757224 · Door Warning SystemSDR CALA2017061901897Switch · stuckINFLIGHT, BOTH LEFT AND RIGHT COMMS FAILED TO TRANSMIT, COULD RECEIVE. EMERGENCY DECLARED. R & R THE FIRST OFFICER'S PTT YOKE SWITCH WHICH WAS FOUND STUCK AND CAPTAIN'S AUDIO PANEL, ALSO R & R THE AUDIO ACCESORY UNIT, ALL OPS CHECKED GOOD IAW AMM 23-12-02, AJun 19, 2017 · N67134 · Boeing 757224 · Communications SystemSDR CALA2017061901884Skin · crackedR4 DOOR INNER SKIN (FWD CENTER) CRACKED. REPAIRED IAW A RES 2012319-55 WITHOUT DEVIATIONS AND EC/RA 5210-02896.Jun 18, 2017 · N34137 · Boeing 757224 · Service DoorsSDR CALA2017061701863Girt Bar · disengagedR4 DOOR HARD TO ARM AND DISARM AND ARM LIGHT NOT ILLUMINATING. PERFORMED ESCAPED SLIDE RENDER SAFE CHECKLIST AND FOUND GIRT BAR NOT FULLY ENGAGED. CYCLED THE GIRT BAR SEVERAL TIMES AND THE R4 DOOR ARMS AND DISARMS PROPERLY WITH INDICATION NORMAL.Jun 17, 2017 · N19136 · Boeing 757224 · Emergency EquipmentSDR CALA2017061701862Lanyard · loose1R DOOR WILL NOT ARM PERFORMED RENDER SAFE 46-0035 AND FOUND SLIDE LANYARD UNDER GIRT BAR. STOWED LANYARD IAW AMM 25-66-10-202-039 DOOR AN SLIDE OPS CHECKED GOOD.Jun 17, 2017 · N34131 · Boeing 757224 · Escape SlideSDR CALA2017061701861Pseu · failedEICAS MESSAGE FOR THE RT FWD EMERGENCY DOORS CAME ON DURING CLIMB. NO PRESENT MESSAGE NOTED. OPENED PANEL, NO FAULTS FOUND. RIGGED PREVIOUSLY ACCOMPLISHED. PSEU CODE 014 LATCHED, CANNOT CLEAR. SUSPECT BAD PSEU (M162). REPLACED PSEU IAW AMM 32-09-04-401. OPJun 17, 2017 · N17128 · Boeing 757224 · Door Warning SystemSDR CALA2017061701860Target · dirtyEICAS MESSAGE FOR RT FWD EMERGENCY DOOR ILLUMINATED IN FLIGHT. ACCOMPLISHED TASK 52-71-00-825-219, TARGETS WITHIN LIMITS. CLEAN TARGETS NO MESSAGESJun 17, 2017 · N17128 · Boeing 757224 · Door Warning SystemSDR CALA2017061701859Switch · dirtyR1 DOOR ARM LIGHT NOT ILLUMINATING WITH DOOR CLOSED. CLEANED SLIDE SWITCH IAW SWP 20-60-01. OPS CHECKED GOOD.Jun 17, 2017 · N18119 · Boeing 757224 · Escape SlideSDR CALA2017061601830Clamp · looseAT FL390, THE RT ENGINE OVERHEAT EICAS INDICATOR ILLUMINATED. EMERGENCY DECLARED. FOUND THE NR 2 ENGINE UPPER FIRE COMBUSTION & TURBINE CASE SENSOR MID CLAMP LOOSE IAW FIM TASK 26-11-00-815-803. SECURED THE CLAMP IAW EIPC 26-11-01 ITEM 430. WRENCH CHECKED Jun 16, 2017 · N12114 · Boeing 757224 · Engine Bleed Air SystemSDR CALA2017061601829Solenoid · faultyENGINE SPEED PARAMETERS EXCEEDED FOR LEFT ENGINE DURING TAKEOFF ROLL. PERFORMED BORO INSPECTION OF THE NR 1 ENGINE IP COMPRESSOR IAW MM 72-00-00-206-147-R02, AND IP TURBINE INSPECTION IAW 72-00-00-206-173-R02. NO DEFECTS NOTED. REMOVED AND REPLACED LEFT AND RJun 16, 2017 · N17104 · Boeing 757224 · Engine Bleed Air System
Back to Boeing 757-224