Boeing 757-232
Service difficulty reports · 15,843
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015102206364Floor Panel · punctured.07500" PUNCTURE IN FWD CARGO COMPARTMENT FLOOR AT FS 800 AND 20" RT OF CENTER. REMOVED FLOOR PANEL ADJACENT TO DAMAGE INSIDE PANEL. ACCOMPLISHED REPAIR IAW ERA 540647-14 MUST BE WITHIN NEXT L-CHECK LIMIT. ACCOMPLISHED INTERIM REPAIR IAW ERA 540647-14. PLESDR DALA2015110506747Gimbal Joint · corrodedNR 8 BALL SCREW GIMBAL MOUNTS CORRODED INTERNALLY, MARKED. REPLACED NR 8 BALL SCREW ASSY IAW AMM 27-51-21.SDR DALA2015100105899Floorbeam · corrodedAFT CARGO BS 1640 FLOORBEAM HAS SOME CORROSION AROUND NUT PLATES. REPAIRED IAW SRM 53-00-51, REPAIR 9.SDR DALA2015100105897Structure · crackedWHILE PERFORMING WC 5750-01176-1201, SLAT INSPECTION, FOUND A CRACK IN THE FIXED L/E UNDER SLAT NR 4. PERFORMED OPTION A TIME LIMITED REPAIR.SDR DALA2015093005885Light · inoperativeEMERGENCY LIGHTS INOPERATIVE ROWS 38-45 DEF. REPLACED IAW AMM 33-51. ALL OPS OK.SDR DALA2015093005887Drive Shaft · corrodedDRIVE SHAFT FOR NR 5 FLAP DRIVE TRANSMISSION IS CORRODED. REPLACED DRIVE SHAFT REF MM 27-51-34.SDR DALA2015093005886Ball Screw · corrodedNR 5 BALLSCREW ASSY, AFT UNIVERAL JOINT ARM CORRODED INTERNALLY. REPLACED JOINT MM 27-51-11.SDR DALA2015092905877Engine · failedAIR RETURN, DUE TO LT ENGINE SHUTDOWN. CREW REPORTED LOUD BANG FOLLOWED BY SMOKE IN THE COCKPIT AND OIL PRESSURE AND QUANTITY DROPPED TO ZERO. MAINTENANCE REPORTS CORE COWLS WET WITH OIL AND ZERO QUANTITY ON EICAS. ENGINE CHANGED AND DUCT BURNOUT PERFORMED.SDR DALA2015092905859Ballscrew · corrodedNR 6 BALLSCREW ASSY, FWD MOUNT AREA OF JACKSCREW CORRODED INTERNALLY AND BALLSCREW GIMBAL MOUNTS ARE CORRODED INTERNALLY. REPLACED JACKSCREW REF MM 27-51 AND REF NR.SDR DALA2015092905858Ballscrew · corrodedNR 6 BALLSCREW ASSY, AFT UNIVERAL JOINT ARM CORRODED INTERNALLY AND BALLSCREW GIMBAL MOUNTS ARE CORRODED INTERNALLY. REPLACED UNIVERSAL JOINT IAW MM 27-51-11.SDR DALA2015092905857Fuse · failedFIRST CLASS SEAT EMERGENCY LIGHTS INOPERATIVE. FOUND BAD FUSE IN POWER SUPPLY. REPLACED FUSE.SDR DALA2015092605856Skin · dentedSKIN DENTED AT BS 1490 STRINGER 25L. REPAIR IAW SRM.SDR DALA2015092805861Line · rupturedRETURNED TO DEPARTURE DUE TO LT HYDRAULIC SYSTEM QTY AND PRESSURE LOSS. FOUND RUPTURED FLEX LINE AT TOP OF THE LT MLG ACTUATOR. REPLACED THE ENGINE DRIVEN PUMP DUE TO METAL IN THE CASE DRAIN FILTERS. SERVICED HYDRAULICS AND RAN ENGINES, LEAK CHECK AND OPS CSDR DALA2015092505825Skin · damagedFUSELAGE SKIN BS 760-778, BS 9L DAMAGED. REPAIRED IAW ER/A 385646-14, REV C.SDR DALA2015092505824Skin · damagedFUSELAGE SKIN BS 760-778, STR 9L DAMAGED. REPAIRE.SDR DALA2015092305806Power Supply · inoperativeFOUND F/C SEAT MOUNTED EMERGENCY LIGHTS NOT TESTING. T/S REF WDM 33-51. FOUND EMERGENCY FLOOR LIGHT POWER PACK, M9101, BAD. R & R PWR PACK, M9101 AND BATTERY REF AMM 33-51. OPS CKS GOOD.SDR DALA2015092305801Connector · disconnectedEMERGENCY LIGHT ROW 20 INOPERATIVE, FOUND CONNECTOR DISCONNECTED UNDER SEAT. SECURED CONNECTOR. OPS CHK GOOD, IAW AMM 33-51.SDR DALA2015092105757Lens · brokenSEAT 19D, ACARS RED TRACK LIGHT BROKEN, INTERIOR. INSTALLED RED LENS. LIGHT CHECKED GOOD IAW AMM 33-31.SDR DALA2015101306104Skin · damagedLIGHTNING STRIKE AT BS 402, 5" BELOW STR 11R. DRILLED DAMAGED RIVET AND INSTALLED BLIND FASTNER IAW R1 AND 539190-14. NEEDS REPEAT INSP AT 500 CYCLE INTERVALS AND SOLI FASTENER INSTALLED NO LATER THAN 3000 CYCLES/24 MONTHS. ERA 539314-14, SECT IV 1 TIME INSSDR DALA2015091505655Support · damagedER/A 471162-14, REV C, LT WING, INBD FLAP, INBD CARRIAGE, AFT ROLLER SUPPORT, ELONGATED HOLES, SECTION II INSPECTIONS.SDR DALA2015090905561Sign · detachedTHE L2 DOOR EMERGENCY EXIT SIGN ABOVE THE DOOR CAME OFF. INSTALLED NEW EXIT SIGN AT L2 DOOR, NOW SECURE. OK FOR SERVICE IAW AMM 33-51.SDR DALA2015090805488Sensor · malfunctionedREPORT OF LT PNEUMATIC BLEED LIGHT WITH PRE-COOLER OUT TEMP AT 510 DEGREES. TROUBLESHOT IAW FIM 36-10-00-815-011. R & R FAN AIR TEMP SENSOR AND LT PRSOV IAW AMM 36-11. ENGINE RUN REQUIRED FOR OPS CK. PNEUMATIC HEALTH CHECK GOOD. AFTER ENGINE RUN HP NOT OPSDR DALA2015090805489Switch · stiffON FIRST FLIGHT, THE OVERHEAD PANEL EMERGENCY LIGHTS SWITCH WAS HARD TO OPERATE. REPLACED OVERHEAD PANEL IAW AMM 33-51. OPS CKS GOOD.SDR DALA2015090705491Smoke Detector · false activationFIRST CLASS LAVATORY SMOKE ALARM SOUNDED DURING APPROACH. HOT WATER HEATER FELT WARM TO TOUCH. A LIGHT SMOKEY HAZE WAS NOTICED IN CEILING AREA WHEN F/A OPENED THE LAVATORY DOOR. PAX E CIG MAY HAVE BEEN USED IN THE LAVATORY, HOWEVER NOT CONFIRMED. CHECKED LASDR DALA2015090305490Slide · damagedR3 JUMPSEAT HIT R3 DOOR AND DAMAGED SLIDE PACK. THE 4 RT DOOR BUSSEL HAS A PUNCTURE IN THE UPPER FWD CORNER. DAMAGE IS NEGLIGIBLE IAW SRM 51-00. REPAIR IS PERMANENT IAW SRM 51-10.SDR DALA2015091705704Web · corrodedL-2 DOOR, LWR WEB IS CORRODED. ADDITIONAL INFORMATION 001-0090:2040-0056-2L/001 00208 THIS DOOR DAMAGE WAS REPAIRED IN SHOP 383 ON S/O KI1414, AND ERA 539186- 14, REV 0.SDR DALA2015083105345Light · damagedON WAKEUP, FOUND PAX SEAT ROW 27DEF EMERGENCY EXIT LIGHT DAMAGED. REPLACED THE LIGHT ASSY. OK FOR SERVICE, IAW AMM 33-51.SDR DALA1703480668Structure · crackedSTA 140 BULKHEAD OUTER RING CHORD CRACK STR 20L & 20R. REPAIRED IAW ERA 522134-14.SDR DALA2015083105344Connector · unsecureSEAT 19 DEF EMERGENCY LIGHT INOPERATIVE. FOUND CONNECTOR LOOSE, SECURED THE CONNECTOR, OPS CHECKED NORMAL.SDR DALA2015082605233Switch · failedEMERGENCY LIGHTS CAME ON STEADY DURING FLIGHT. CYCLING EMERGENCY LIGHTS, SWITCHED TO OFF AND ARMED, LIGHTS EXTINGUISHED. FOUND RT NLG CONTROL PANEL SWITCH PIN 2 GROUNDING, REPLACED THE SWITCH, OPS NORMAL IAW AMM 33-51.SDR DALA2015082405206Connector · damagedSEAT 23 D, E, F EMERGENCY LIGHT INOPERATIVE. R & R LIGHT PIGTAIL ASSY. OPS CHECKED GOOD.SDR DALA2015082105121Power Supply · inoperativeDURING SERVICE CK FOUND EMERGENCY BULLNOSE AND EXIT SIGNS IN FIRST CLASS SECTION RT SIDE INOPERATIVE. REPLACED POWER SUPPLY IAW AMM 33-51-07, OPS CHECKED GOOD.SDR DALA2015082105120Wire · failedEMERGENCY LIGHT INOPERATIVE AT SEAT 30R. FOUND WIRE SECTION BAD AT SEAT 30R. REPLACED THE WIRED IAW SWPM. CHECKED GOOD. OK FOR SERVICE.SDR DALA2015082105118Wire · broken43D EMERGENCY LIGHT INOPERATIVE. FOUND BROKEN WIRE FROM OTBD HARNESS CONNECTOR. REPAIRED IAW SWPM 20-30-12, OPS CHECKED OK.SDR FDEA201508192644Skin · dentedLEFT WING INBD FLAP, LOWER SURFACE HAS A DENT WS 204. OUND TO BE OUT OF LIMITS IAW SRM 57-53-01-1A FIG 101. REPAIRED IAW SRM 51-70-10-2R PARA 20. PRIMED & TOP COATED IAW SRM 51-70-10-2R PARA 20 & AMM 51-21-10-7.SDR DALA2015081805126Girt Bar · unsecureAFT DOOR SLIDE, GIRT BAR HANGING DOWN. SECURED THE GIRT BAR TO CORNER. SLIDE GIRT BAR OPS CHECKED NORMAL IAW AMM 5211.SDR DALA2015082005123Bearing · inoperativeDIVERTED DUE TO ELECTRICAL ODOR COMING FROM THE MID GALLEY AREA. FOUND RT RECIRCULATION FAN INOPERATIVE DUE TO BEARING FAILURE. REMOVED FAN IAW AMM 21-25. INSTALLED A NEW RECIRCULATION FAN AND VIBRATION MONITOR. OPS CHECKED GOOD.SDR DALA2015081905028Generator · failedACFT 680, ON TAKEOFF ROLL, RT GENERATOR FAILED AGAIN ON APPLICATION OF TAKEOFF POWER. REJECTED TAKEOFF AT 10 KNOTS. RETURNED TO GATE. T/S RIGHT IDG. REPLACED IAW LOGPAGE 7191082.SDR DALA2015081905027Idg · failedACFT 680, ON TAKEOFF ROLL, NR 2 IDG DROPPED OFF LINE. ABORTED TAKEOFF. PERFORMED BITE OF BPCU IAW FIM 24-20-00-810-802. FAULTS RIGHT IDG. REPLACED RT IDG IAW AMM 24-11-01. TESTS GOOD AND NO LEAKS IAW AMM 71-00 AND 24-11.SDR DALA2015081805025Fan · failedNOTICED A SLIGHT ODOR OF ELECTRICAL SMOKE OR POSSIBLE PLASTIC BURNING IN OVEN. CALLED F/A & WHO SAID OVENS WERE OFF BUT THEY NOTICED THE ODOR IN THE CABIN. ODOR DISSIPATED IN A COUPLE OF MINUTES. NO VISIBLE SMOKE. NOTHING INOPERATIVE IN CABIN OR FLIGHT DECSDR DALA2015081705026Lock · missingDOOR 4R GIRT BAR FELL OUT. FOUND FWD POSITION GIRT BAR LOCK MISSING AT 4R DOOR. INSPECTED SLIDE PACK AND GIRT BAR ASSY NO DAMAGE NOTED. INSTALLED SERVICEABLE GIRT BAR LOCK AT FWD POSITION. 4R DOOR SLIDE ARMING AND DISARMING OK IAW AMM 25-66-07.SDR DALA2015081605020Fuse · failedEMERGENCY ESCAPE LIGHTING ON SEAT 38 TO 45 INOPERATIVE. TROUBLESHOT IAW WIRING DIAGRAM 33-51-16 FOUND BAD FUSE, M11649 BATTERY CHARGER, R & R FUSE AND OPS CHECKED GOOD IAW AMM 33-51-07.SDR DALA2015081304961Wire · damagedEMERGENCY LIGHT INOPERATIVE AT SEAT 43FED. REPAIRED WIRE AND OPS CHECKED GOOD REF SWPM 20-64-17.SDR DALA2015081104896Socket · dirtyEMERGENCY LIGHT INOPERATIVE 2R DOOR OUTSIDE. CLEANED SOCKET.SDR DALA2015081104889Terminal · dirtyEMERGENCY LIGHT INOPERATIVE 1 RT DOOR OUTSIDE. CLEANED WIRE TERMINALS AT SOCKET.SDR DALA2015080604898Seal · crackedNR 1 PYLON AFT FIRE SEAL CRACKED. REMOVED AND DRILLED NEW FIRE SEAL IAW DWG. BEGAN INSTALLING NEW FIRE SEAL IAW DWG VERTICAL FASTENERS NEED INSTALLED, COMPLETED INSTALLATION IAW DWG.SDR DALA2015080504793Wire · brokenINSEAT EMERGENCY LIGHT AT 1DC INOPERATIVE. FOUND BROKEN WIRES. R & R LIGHT ASSY IAW AMM 33-51-04. OPS CHECKED GOOD.SDR DALA2015080204784Structure · damagedNR 10 SLAT LOWER AFT EDGE SEAL IS DAMAGED AT THE INBD END EDGE. COMPOSITE FIBERS EXPOSED. RESTORED SURFACE FINISH IAW SRM 57-43-01.SDR DALA2015073104760Lamp · inoperativeDURING SERVICE CHECK, FOUND NUMEROUS EMERGENCY LIGHTS INOPERATIVE IN CABIN. REPLACED THE LAMPED AND REPAIRED THE EMERGENCY LIGHT IAW SWPM 20-30-00. OPS CHECKED GOOD, OK FOR SERVICE.SDR IXXA20150723083Battery Pack · inoperativeDURING THE COURSE OF DAILY CHECK, EMERGENCY EXIT LIGHTING FOUND TO BE INOPERATIVE. R & R BATTERY POWER SUPPLY IAW AMM 33-51-07. OPERATIONAL CHECKED SATISFACTORY. ACFT RELEASED TO SERVICE.
Back to Boeing 757-232