Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA1566411Floor Panel · damagedINSPECTION TYPE:C3, BS 900-1020, RBL 01-25, WL208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566410Floor Panel · damagedINSPECTION TYPE:C3, BS 900-1020, RBL 25-45 WL 208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-520-9692-G.SDR IPXA1566401Floorboard · damagedINSPECTION TYPE:C3, BS 900-1020, LBL 0-25, WL 208, FLOORBOARD HAS EDGE DAMAGE FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1566400Floor Panel · damagedINSPECTION TYPE:C3, BS 900-1020. LBL 24-44, WL 208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA1566399Floorboard · damagedINSPECTION TYPE:C3, BS-1020-1060, LBL 0-25, WL 208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT PANEL IAW EO NR B757-5320-9692-G.SDR IPXA11566982Frame · gougedINSPECTION TYPE:C3, MAIN DECK CARGO DOOR-4 EA GOUGES IN FRAME-STA 487-3, 4, 5.5 AND 8.5 INCHES UP FROM BOTTOM. R & R FRAME DOUBLER IAW SRM 51-40-02.SDR IPXA11566807Frame · gougedINSPECTION TYPE:C3, MAIN CARGO DOOR-INTERIOR STRUCTURE-GOUGED IN FRAME-STA 540-5 INCHES UP FROM BOTTOM. REPAIRED IAW ENGINEERING REPAIR NR 11-02746.SDR IPXA11566747Frame · gougedINSPECTION TYPE:C3, MAIN CARGO DOOR-INTERIOR STRUCTURE-GOUGED IN FRAME-STA 560-5 INCHES UP FROM BOTTOM. REPAIRED IAW ENGINEERING REPAIR 11-02732SDR IPXA11566727Floor Support · corrodedINSPECTION TYPE:C3, CORROSION ON 4 EA NUTPLATES ON LWR SURFACE OF FLOOR SUPPORT RBL 13.5, BS 312-322, WL 207.5. REPLACED IAW SRM 51-10-02-0G.SDR IPXA1566662Door Frame · gougedINSPECTION TYPE:C, MAIN DECK CARGO DOOR - INTERIOR STRUCTURE - GOUGE IN FRAME - STA 612 - 4" UP FROM BOTTOM. REPLACED FRAME ANGLE IAW SRM 51-40-02 AND DWG 69-24182.SDR IPXA11566466Floorboard · gougedINSPECTION TYPE:C3, MCD INTERIOR STRUCTURE, WEB HAS GOUGE 5" UP FROM BOTTOM EDGE. FABRICATED NEW FLOORBOARD IAW DWG 65-49309 AND SRM 50-10-02-0G, 51-40-02-0G, 51-40-05-0G.SDR IPXA11566919Shear Web · corrodedINSPECTION TYPE:C3, CORROSION ON UPPER SURFACE OF SHEAR WEB AT 9PLACES, BS 324-333, LBL 47.5 TO LBL 61.5, WL 208. REPAIR IAW EO B757-5310-42904-A DATED 01-JUN-2011 AND ATS ER 11-02729 DATED 31-MAY-2011.SDR IPXA1566691Floor Support · corrodedINSPECTION TYPE:C3, CORROSION ON UPPER SURFACE OF FLOOR SUPPORT BS 297-310, LBL 59.5, WL 208. REPLACED PART IAW SRM 51-40-2.SDR IPXA1566690Floor Support · corrodedINSPECTION TYPE:C3, CORROSION ON UPPER SURFACE OF FLOOR SUPPORT BS 312-322, LBL 59.5, WL 208. REPLACED PART IAW SRM 51-40-02.SDR IPXA11566608Support Angle · gougedINSP TYPE:C3, CREW ENTRY DOOR LWR SILL SUPPORT ANGLE HORIZ FLANGE UPPER SURFACE HAS 2 GOUGES, BS 298 AND BS 323 WL 215 LBL 63 (MARKED). REPLACED INNER CHORD ANGLE BS 298-323, WL 215, LBL 63, IAW SRM 53-10-15-1A 1, SRM 53-10-15-0I-1, SRM 51-40-02-0G, SRM 51-40SDR IPXA11566550Sill · gougedINSPECTION TYPE:C3, CREW ENTRY DOOR LWR SILL UPPER SURFACE HAS SEVERAL GOUGES, BS 298-323, WL 215, LBL 64. R & R IAW SRM 51-40-02-0G; SRM 53-10-15-1A1; SRM 53-10-15-OI 1 SRM 51-40-05-0G; DWG 141N8326; SRM 51-20-01-0G; SRM 51-20-05-0G.SDR IPXA11566535Floor Panel · delaminatedINSPECTION TYPE:C3, COCKPIT FLOOR PANEL BS 297-333, RBL 10 TO RBL 60 HAS DELAMINATION ON LOWER SURFACE AT POTTED INSERT. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566836Floor Skin · corrodedINSPECTION TYPE:C3, CORROSION ON COCKPIT FLOOR UPPER SURFACE AT CAPT'S INBD AFT SEAT TRACK AT 2 PLACES, BS 254-27. (MARKED) REPAIR DOUBLER IAW ATS ER11-02718, AND EO B757-5310-42849-A.SDR IPXA11566835Floor Skin · corrodedINSPECTION TYPE:C3, CORROSION ON COCKPIT FLOOR UPPER SURFACE AT CAPT'S INBD FWD SEAT TRACK AT 3 PLACES, BS244-257. (MARKED) REPAIR DOUBLER IAW ER 11-02718, AND EO B757-5310-42849-A.SDR IPXA11566534Strap · corrodedINSPECTION TYPE:C3, CORROSION ON COCKPIT FLOOR STRAP UPPER SURFACE BS 293, RBL 2, WL 200. R & R STRAP IAW SRM 51-40-02.SDR IPXA11566510Strap · corrodedINSPECTION TYPE:C3, CORROSION ON COCKPIT FLOOR STRAP. FABRICATED AND REPLACED COCKPIT FLOOR STRAP IAW SRM.SDR IPXA11566508Strap · corrodedINSPECTION TYPE:C3, CORROSION ON COCKPIT FLOOR STRAP. FABRICATED AND REPLACED COCKPIT FLOOR STRAP IAW SRM.SDR IPXA1566274Actuator · inoperativeGEAR LEVER WOULD NOT MOVE TO UP POS IN FLIGHT.WAS FREE TO MOVE TO UP P OS WHEN LOCK OVRD PUSHED. T/S PER FIM 32-30-00. FOUND LUG ON THE END OF TRUCK POSITIONER ACTUATOR BROKEN. (LT GEAR) R&R LEFT MLG TRUCK POSITIONER ACTUATOR IAW MM 32-32-15-4.SDR IPXA1566645Frame · dentedINSPECTION TYPE:C1, AFT CARGO COMPARTMENT STA 1240 BETWEEN STR 23L AND 24L FRAME IS DENTED ON INBD FLANGE. CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR ANGLE AND STRINGER CLIP IAW SRM 53-00-07-2R 5, DETAIL III, EA 11044 IR.SDR IPXA11566549Floorboard · damagedINSPECTION TYPE:C1, DAMAGE ON UPPER SURFACE OF MAIN DECK FLOORBOARD 251XRF. FABRICATED REPLACEMENT FLOORBOARD NR 251XRF IAW B757-5320-9692-G.SDR IPXA11566267Static Inverter · inoperativeSTANDBY ATTITUDE, GYRO FLAG INTERMITTENTLY IN VIEW. FLIGHT DIVERTED, ENROUTE. R & R STATIC INVERTER IAW 34-24-02-4. R & R STANDBY ATTITUDE IND IAW 34-24-01-4. OPS CKS GOOD.SDR IPXA11566580Shear Web · corrodedINSPECTION TYPE:C1, CABIN FLOOR SHEAR WEB AT BODY STA 1700+3 AND LBL 41, WEB IS CORRODED. REMOVED CORROSION, ORIGINAL THICKNESS .071, LOSS OF .010 WITH .061 MATERIAL LOSS IS OUT OF LIMITS IAW SRM 53-00-51-1A1. ACCOMPLISHED EA 1104 54/ EO B757-5310-42643-A FORSDR IPXA1566653Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO PIT FRAME AT STA BS 840, BELOW STRINGER 24L FREE FLANGE IS DENTED. REPAIRED FRAME AT BS 840 STR 24L IAW EA 110439.SDR IPXA1566652Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO COMPARTMENT FRAME AT STA 870, AT STR 24L, INBD FREE FLANGE IS DENTED. CUT OUT DAMAGE. FABRICATED REPAIR J, SHEAR TIE AND STRINGER CLIP INSTALLED IAW SRM 53-00-07-2R 5 DETAIL III AND EA 110438.SDR IPXA1566651Frame · dentedINSPECTION TYPE:C1, AFT CARGO COMPARTMENT STA 1260, STR 26L FRAME IS DENTED ON INBD FLANGE. CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR ANGLE, SHEAR TIE AND STRINGER CLIP IAW SRM 53-00-07-2R 5 DETAIL III AND EA 110443 IR.SDR IPXA1566649Frame · dentedINSPECTION TYPE:C1, AFT CARGO COMPARTMENT STA 1260 JUST BELOW STR 25R, FRAME IS DENTED ON INBD FLANGE CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07-2R-5 AND EA11044 IR.SDR IPXA1566647Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO PIT FRAME AT BS 660 BETWEEN STRINGER 24R AND 25R, IS DENTED ON INBD FREE FLANGE CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR ANGLES SHEER TIE AND STRINGER CLIPS IAW SRM 53-00-07-2R 5 DETAIL III AND EA 110434 IRSDR IPXA1566353Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO PIT FRAME AT BS 720 BELOW STRINGER 23L, IS DENTED. REMOVED DAMAGED SECTION OF FRAME AT STA 720, STR 23L. FABRICATED REPAIR PARTS FROM 7075-T6.071. INSTALLED REPAIR IAW SRM 53-00-07-2R5, DETAIL 1.SDR IPXA11566221Power Supply · inoperativeINSPECTION TYPE: PS EMERGENCY LIGHTS INOP -GOES DIM/OFF AFTER 3 SECONDS. REPLACED POWER SUPPLY IAW AMM 33-51-07-2.SDR IPXA11566211Lamp · inoperativeEIGHT LAMPS INOP IN EMERGENCY LIGHT ASSY. RELAMPED EIGHT LAMPS IN EMERGENCY EXIT SIGN IAW AMM 33 51 01 2.SDR IPXA11566210Battery Pack · dischargedEMERGENCY LIGHTS INOP BATTERY DEAD (SWITCH FAILED IN "ON" POSITION). R & R BATTERY PACK MM 33-51-07-2. OPS CK GOOD.SDR IPXA11566133Line · splitLOST LT HYD SYS PSI. T/S SYS FOUND LT MLG DOWN LOCK ACTUATOR RETURN LINE SPLIT. R & R LINE W/REF TO IPC 32-32-51-15 AND AMM 32-11-12-4.SDR IPXA1567767Floor Panel · damagedINSPECTION TYPE:C-1 MANI CARGO COMPARTMENT FLOOR PANEL 241XMF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566589Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO DECK STA 1541, RBL 47, SMALL AREAS OF CORROSION AROUND SEAT TRACK FASTENER. REPAIRED MAIN CARGO DECK SEAT TRACK STA 1541, RBL 47 IAW SRM 53-00-52-2 R, REPAIR 5.SDR IPXA1566443Seat Track · corrodedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR STRUCTURE STA 1540, RBL 47 SEAT TRACK HAS SMALL AREA OF CORROSION AT FASTENER HOLE. REPAIRED MAIN CARGO COMPARTMENT SEAT TRACK STA 1540, RBL 47 IAW SRM 53- 00-52-2R 5.SDR IPXA1566286Skin · delaminatedINSPECTION TYPE:C4, APU BAY INNER SKIN HAS DELAMINATED AREA APROX 5" AFT OF FRAME AT STA 1918.90 AND APROX 15" UP FROM RT APU DOOR HINGE. REPAIRED SKIN IAW EA 110406IR.SDR IPXA11566585Frame · dentedINSPECTION TYPE:C3, AFT PIT STA 1300 AT S-21R FRAME IS DENTED. REPAIRED AFT PIT FRAME STA 1300-S-21R IAW EA 110395.SDR IPXA11566553Floor Panel · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOOR PANEL 232BF HAS INSERTS PULLED OUT AND EDGE DAMAGE. FABRICATED NEW MAIN CARGO COMPARTMENT FLOOR PANEL.SDR IPXA11566117Skin · corrodedCORROSION FOUND AT APPROX STA 1918, RT SIDE ABOUT 3 IN FWD OF ELEVATOR TARGET SCALE. ADDITIONAL DAMAGE FOUND AT STA 1920 RT SIDE. INSPECTED DAMAGED AREA AND FABRICATED INTERIM DOUBLER AND FILLER IAW EO B757-530-42292-A AND SRM 51-70-18-0. INSTALLED INTERIM DSDR IPXA1566614Frame · dentedINSPECTION TYPE:C3, AFT PIT STA 1620 FRAME IS DENTED ABOVE STR 26R. REPAIRED FRAME STA 1620 ABOVE STR 26R IAW SRM 53-00-07-2R-5 AND EA 110 397.SDR IPXA11566598Frame · dentedINSPECTION TYPE:C3, AFT PIT STA 1580 FRAME IS DENTED BETWEEN STR 21R AND 22R. REMOVED DAMAGE AND REPAIRED FRAME SECTION IAW EA 110396.SDR IPXA11566586Frame · damagedINSPECTION TYPE:C3, AFT PIT STA 1380 LOWER FRAME DOUBLER UPPER SURFACE HAS TOOLING DAMAGE. REPLACED AFT PIT STA 1380 FRAME SECTION IAW SRM 51-40-02, DWG 146N1010 , DWG 146N8511 AND DWG 65-88700.SDR IPXA1566612Floor Panel · corrodedINSPECTION TYPE:C3, CONTROL CABIN FLOOR AROUND F/O INBD FWD SEAT TRACK, FLOOR IS CORRODED IN SEVERAL PLACES, MARKED. BLENDED AREAS AND ACCOMPLISHED REPAIR IAW EA 110389 IR.SDR IPXA11566584Seat Track · corrodedINSPECTION TYPE:C3, CONTROL CABIN FLOOR AROUND F/O INBD AFT SEAT TRACK, FLOOR IS CORRODED IN SEVERAL PLACES, MARKED. BLENDED AREAS AND ACCOMPLISHED REPAIR IAW EA 110389 IR.SDR IPXA11566583Seat Track · corrodedINSPECTION TYPE:C3, CONTROL CABIN FLOOR AROUND F/O INBD FWD SEAT TRACK, FLOOR IS CORRODED IN SEVERAL PLACES, MARKED BLENDED AREAS AND ACCOMPLISHED REPAIR IAW EA110389 IR.
Back to Boeing 757-24APF