Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09556512Floorbeam · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1200, LBL 60-RBL 60 FLOORBEAM HAS CORROSION AT SEVERAL PLACES ON UPPER SURFACE. REMOVED CORROSION FROM NUT PLATE HOLES ON FLOORBEAM MEASURED ALL BLENDED AREAS SUBMITTED AND RECEIVED ENGINEERING, FABRICATED CLIPS, STIFFENESDR IPXA09556508Floorbeam · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1100 RBL 5, FLOORBEAM IS CORRODED. REMOVED CORROSION, BLENDED TO A RATIO OF 10 TO 1. FLAP PEENED BLENDED AREA. FABRICATED REPAIR ANGLE. ALODINED AND PRIMED REPAIR AREA AND REPAIR ANGLE. INSTALLED REPAIR ANGLE.SDR IPXA09556504Seat Track · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1180-1200 LBL 25 SEAT TRACK HAS CORROSION ON UPPER SURFACE. REMOVED AND REPLACED BS 1180-1200 LBL 25 PER SRM 51-40-02-06.SDR IPXA09556499Skin · gougedINSPECTION TYPE:C2, 1 INCH GOUGE IN FUSELAGE SKIN BS 479 STR 14L. BLENDED, HFED REPAIRED IAW ATS ER 09-3155.SDR IPXA09556491Seat Track · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1180-1200, LBL 25 SEAT TRACK HAS CORROSION ON UPPER SURFACE. REMOVED AND REPLACED SEAT TRACK BS 1180-1200, LBL 25 PER SRM 51-40-02-06.SDR IPXA09556490Floor Support · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1013-1040 LBL 45 LONGITUDINAL FLOOR SUPPORT HAS CORROSION ON UPPER SURFACE. REPAIRED PER ATS ENGINEERING 09-3129 DATED 25JUNE09.SDR IPXA09556489Seat Track · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1075-1100, LBL 45 SEAT TRACK HAS CORROSION ON UPPER SURFACE. SEAT TRACK REPLACED PER SRM 51-40-02.SDR IPXA09556488Floor Support · corrodedINSPECTION TYPE:C2 FLOOR SUPPORT CORRODED BS 1040-1075 LBL 45, WL 208. REMOVED, FABRICATED AND INSTALLED PER SRM 51-40-02-0G.SDR IPXA09556487Seat Track · corrodedINSPECTION TYPE:C2 SEAT TRACK CORRODED BS 1180-1200 RBL 45, WL 208. REMOVED AND REPLACED SEAT TRACK PER SRM 51-40-02.SDR IPXA09556486Seat Track · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1198 RBL 25 SEAT TRACK HAS CORROSION ON UPPER SURFACE. SEAT TRACK WAS REPLACED PER SRM 51-40-02.SDR IPXA09556485Seat Track · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1180-1200 LBL 45 HAS CORROSION ON UPPER SURFACE. REMOVED AND REPLACED SEAT TRACK IAW SRM 51-40-2.SDR IPXA09556484Stop Fitting · gougedINSPECTION TYPE:C2 MAIN CARGO DOOR UPPER AFT STOP PIN FITTING IS GOUGED. BLENDED PER SRM ADDENDUM B757-5310-15194-C.SDR IPXA09556483Stop Fitting · gougedINSPECTION TYPE:C2 MAIN CARGO DOOR UPPER FWD STOP PIN FITTING IS GOUGED. BLENDED PER SRM ADDENDUM B757-5310-15194-C.SDR IPXA09556292Switch · inoperativeINSPECTION TYPE:N/A ATB - L NAV WOULD NOT ENGAGE - WHEN PRESSING L NAV SYSTEM LIGHTS ON PANEL WOULD SHORT OUT. V NAV WOULD NOT ENGAGE. FLT LEVEL CHANGE WOULD NOT ENGAGE. DEFERRED PER MEL 22-11-4-11. M402419 ASSIGNED. ***SDR FILED OPEN***SDR IPXA09556290Floor Panel · defectiveINSPECTION TYPE:C2 FABRICATE NEW FLOOR PANEL FROM BS 1020 TO BS 1055 BL 0 TO RBL 25. EXISTING FLOOR PANEL DOES NOT LINE UP WITH NEW FLOOR SUPPORT AT BS 1055. FABRICATED NEW FLOOR PANEL IAW SRM ADDENDUM B757-5320-9692-G.SDR IPXA09556291Floor Panel · defectiveINSPECTION TYPE:C2 FABRICATE NEW FLOOR PANEL FROM BS 1040-1060 LBL 0 - RBL 25. EXISTING FLOOR PANEL DOES NOT LINE UP WITH NEW FLOOR SUPPORT AT BS 1060. FABRICATED NEW FLOOR PANEL IAW SRM ADDENDUM B757-5320-9692-G.SDR IPXA09556253Window · stuckINSPECTION TYPE:N/A R2 WINDOW WILL NOT OPEN. REWORKED R/O'S WINDOW FWD STRIKER BRACKET PER EO B757-5610-5738.SDR IPXA09556327Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL STA 1060 TO 1100 RBL 25 TO 45 HAS A BROKEN EDGE FASTENER HOLE. FAB FLOOR PANEL FROM STA 1060-1100 RBL 25-45 ON MAE TR T9/795466 PER IPXA EO B757-5320-9692-G APPX A & APPX B (FOR FABRICATION STEPS) MATL A402H BATCH 1333430.SDR IPXA09556326Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL STA 1100 TO 1200 RBL 45 TO 55 HAS BROKEN EDGE FASTENER HOLE. FAB FLOOR PANEL FROM STA 1100-1200 RBL 45 TO 55 ON MAE TR T9/795463 PER IPXA EO B757-5320-9692-G APPX A & APPX B (FOR FABRICATION STEPS) MATL A402H BATCH 1333430.SDR IPXA09556325Floor Panel · crackedINSPECTION TYPE:C MCD FLOOR PANEL STA 1100 TO 1200 RBL 25 TO 45 IS CRACKED AT MID SECTION ON FAB FLOOR PANEL FROM STA 1100-1200 RBL 25-45 ON MAE TR T9/795465 PER IPXA EO B757-5320-9692-G APPX A & APPX B (FOR FABRICATION STEPS) MATL A402H BATCH 1333430.SDR IPXA09556324Floor Panel · puncturedINSPECTION TYPE:C MCD FLOOR PANEL STA 1100 TO 1200 LBL 45 TO 55 HAS UPPER SKIN DAMAGED. FAB FLOOR PANEL FROM STA 1100-1200 LBL 45-55 ON MAE TR T9/795464 PER IPXA EO B757-5320-9692-G APPX A AND APPX B (FOR FABRICATION STEPS).SDR IPXA09556323Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL STA 1100 TO 1200 LBL 45 TO 55 HAS UPPER SKIN DAMAGED. FAB FLOOR PANEL FROM STA 1100 TO 1200 LBL 45-55 ON MAE TR T9/795464 PER EO B757-5320-9692 APPX A AND APPX B (FOR FABRICATION STEPS).SDR IPXA09556226Intercostal · corrodedINSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL AT BS 1055 RBL 27-43 WL 208. BLENDED CORROSION AND TOOLING MARKS FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED PER SRM 51-40-05 AND OHM 20-50-01.SDR IPXA09556225Intercostal · corrodedINSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL AT BS 1020 RBL 2-22 WL 208. BLENDED CORROSION AND TOOLING MARKS FOUND REWORKED AREAS TO BE OUT OF LIMITS, REPLACED INTERCOSTAL PER SRM 51-40-05 AND OHM 20-50-01.SDR IPXA09556199Throttle · out of adjustRIGHT ENGINE WOULD NOT GO TO REQUESTED TAKEOFF THRUST. RETURNED TO BFM. ADJUSTED NR 2 ENGINE THROTTLE IAW MM 76-11-03 AND COMPLIED WITH TAKEOFF POWER TEST 13 IAW MM 71-00-00-3. OPS CHECK GOOD, 1.73 EPR OBTAINED.SDR IPXA09556344Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1320 ABOVE S-26R. DENT FOUND OUT OF LIMITS IAW SRM 53-00-07-1A1, FIG 101. CUT OUT DAMAGE AREA IAW SRM 57-00-07-2R5. HFEC CUT OUT AND EXISTING OPEN HOLES IAW NDT 51-00-01PT6/-16PT6, NO CRACKS NOTEDSDR IPXA09556343Floor Panel · corrodedINSPECTION TYPE:C2 FWD CARGO BAY NR 3 FLOOR PANEL IS CORRODED ON THE TOP. FABRICATED FWD CARGO BAY NR 3 FLOOR PANEL AND INSTALLED IAW SRM 51-40-02-0G, SRM 53-30-53-0I.SDR IPXA09556342Floorbeam · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1029 RBL 45 LONGITUDINAL FLOORBEAM HAS CORROSION O/B FLANGE. REPAIRED PER ER 09-3034 DATED 06/12/09.SDR IPXA09556341Floorbeam · corrodedINSPECTION TYPE:C2 FLOORBEAM BS 1016 BL 0 CORRODED ON UPPER FLANGE. REPAIRED PER ATS ER 09-3033.SDR IPXA09556337Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1100-1200, RBL 45-60, FLOOR PANEL HAS BROKEN/MISSING INSERTS. FABRICATED NEW FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA09556336Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1100-1200, RBL 25-45 FLOOR PANEL HAS BROKEN/MISSING INSERTS. FABRICATED NEW FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA09556335Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO DECK BS 1100-1200 BL 0 - RBL 25, FLOOR PANEL HAS BROKEN/MISSING INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA09556334Floor Support · corrodedINSPECTION TYPE:C2 BS 1055 LBL 25-45 FLOOR PANEL HAS CORROSION. FABRICATED PANEL SUPPORT IAW SRM 51-40-05-0G, 51-40-02-0G, 51-20-01- 0G.SDR IPXA09556333Floor Support · puncturedINSPECTION TYPE:C2 BS 1020 BL 0-LBL 25 FLOOR PANEL SUPPORTS PUNCTURED. FABRICATED NEW PANEL SUPPORT IAW SRM 51-40-05-OG, 51-40-02-0G, 51-40-01-0B.SDR IPXA09556249Floorbeam · corrodedINSPECTION TYPE:C2 BS 1040-1080 BL 0 LONGITUDINAL FLOORBEAM HAS SEVERAL SPOTS OF CORROSION. REMOVED AND REPLACED BS 1040-1080 BL 0 FLOORBEAM IAW SRM 51-40-05-0G, SRM 51-40-08-0G AND SRM 51-40-02-0G.SDR IPXA09556232Floor Panel · brokenINSPECTION TYPE-C2 MAIN CARGO DECK BS 900-10200 LBL 45-60 FLOOR PANEL HAS BROKEN / MISSING INSERTS. REPLACED PANEL IAW SRM ADDENDUM B757-5320-9692-G2.SDR IPXA09556231Floor Panel · brokenINSPECTION TYPE-C2 MAIN CARGO DECK BS 1060-1100 BL 0 LBL 25 FLOOR PANEL HAS BROKEN/ MISSING INSERTS. REPLACED PANEL IAW SRM ADDENDUM B757-5320-9692-G2.SDR IPXA09556419Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1280 BETWEEN STRINGERS S-25R AND S-26R. DENT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG 101. CUT OUT DAMAGE AREA IAW EA757-5362-27-A1875. HFEC AT CUT OUT + OPEN HOLES IAW NTM51-00-19PT6/-SDR IPXA09556418Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1300 AT STRINGER S-26R. DENT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGE PER EA757-5362-27-A1878. HFEC AT CUT OUT + OPEN HOLES IAW NDT51-00-19PT6/-16PT6, NO CRACKS FOUNDSDR IPXA09556416Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1260 BETWEEN STRINGERS S-26L AND S-27L. DENT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGED AREA IAW EA757-5362-27-A1877. HFEC INSPECT AT CUT OUT AND HOLES IAW NDT 51-00-SDR IPXA09556396Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1220 AT STRINGER S-26R. DENT WAS FOUND TO BE OUT OF LIMITS IAW SRM 51-00-07, FIG 101. CUT OUT DAMAGED AREA IAW EA 757-5362-27-A1874. HFEC INSPECT AT CUTOUT + HOLES IAW NTM51-00-19PT6/-16PT6, NO CRSDR IPXA09556395Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1620, ABOVE STRINGER S-26R. DENT FOUND TO BE OUT OF LIMIT IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGE AREA IAW SRM 51-00-07-2R5. HFEC INSPECT AT CUTOUT + HOLES IAW NDT 51-00-01PT6/-16PT6, NO CRACKS FSDR IPXA09556392Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1500 ABOVE STRINGER S-25L. DENT FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGE IAW SRM 53-00-07-2R5. HFEC AT CUT OUT + HOLES IAW NDT51-00-01 PT6/-16PT6, NO CRACKS FOUND. FAB RSDR IPXA09556391Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1540 ON STRINGER S-25L. DENT FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGE IAW SRM 53-00-07-2R5. HFEC AT CUT OUT + HOLES IAW NTM51-00-19 PT6/-16PT6, NO CRACKS FOUND. FAB REPASDR IPXA09556390Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME 1600 BETWEEN STRINGERS S-25L AND S-26L. DENT FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGE IAW SRM 53-00-07-2R5. HFEC AT CUT OUT + HOLES IAW NDT51-00-01 PT6/-16PT6, NO CRACKS FOUNSDR IPXA09556389Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1580 ABOVE S-26L. DENT FOUND TO BE OUT OF LIMITS IAW 53-00-07 FIG 101. CUT OUT DAMAGED AREA IAW 53-00-07-2R5. HFEC CUT OUT AND EXISTING HOLES IAW NDT 51-00 -01PT6/-16PT6, NO CRACKS FOUND. FAB REPSDR IPXA09556388Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1500 BETWEEN STRINGERS S-25R AND S-26R. DENT FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGE AREA IAW SRM 53-00-07-2R5. HFEC AT CUT OUT + HOLES IAW NTM 51- 00-19PT6/-16PT6, NO CSDR IPXA09556387Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT STA 1440 AT STRINGER S-23L. DENT FOUND OUT OF LIMITS SRM 53-00-07 FIG 101. CUT OUT DAMAGE AREA IAW SRM 53-00-07-2R5, FIG 201. HFEC CUT OUT AND EXISTING OPEN HOLES IAW NTM51-00-19PT6/-16PT6, NO CRACKS FOUND. FSDR IPXA09556372Frame · dentedINSPECTION TYPE:C DENT ON AFT CARGO COMPARTMENT AT FRAME STA 1520, S-25L AND BELOW S-26L. DENT FOUND OUT OF LIMIT IAW SRM 53-00-07, FIG 101. CUT OUT DENT IAW EA757-5362-27-A18879. HFEC AT THREE EACH CUT OUT AND EXIST OPEN HOLES PER NTD51-00-19PT6/-16PT6, NOSDR IPXA09556371Frame · dentedINSPECTION TYPE:C TWO EACH DENTS AT BULK CARGO COMPT AT FRAME STA 1480, ABOVE AND BELOW STRINGER S-26L. DENTS WERE FOUND OUT OF LIMITS IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGED AREA IAW SRM 53-00-07-2R5 FIG 201. HFEC CUT OUT AND EXISTING HOLES IAW NTM51-00-
Back to Boeing 757-24APF