SDR DALA1019945525Floor Support · corrodedDURING M-CHECK, FOUND CORROSION ON FLOOR SUPPORT CHANNEL AT BS 377.7, BL0, WL 208. REPAIRED IAW SRM 51-40-05.SDR DALA1019935525Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM STRUCTURE AT BS 365 BL0. REPAIRED IAW SRM 53-00-51, FIG 101.SDR DALA1019535522Skin · dentedDURING M-CHECK FOUND DENT IN LOWER FUSELAGE SKIN BETWEEN BS 660 & BS 680 STRINGER 23L & STRINGER 24L. REPAIRED IAW SRM 53-00-01 FIG 201, SRM 51-42-11.SDR DALA1019265637Video Unit · odorDURING FLIGHT, CREW EXPERIENCED A CARBON-SMOLDER ODOR NEAR ROWS 1 & 2. VIDEO EQUIPMENT WAS SHUTOFF AND ODOR DISSIPATED. MX CHECKED SEVERAL CABIN SYS AND REPLACED THE VIDEO REPRODUCER AND CONTROL UNIT. OPS CHECK WAS GOOD.SDR DALA1019235503Stringer · damagedDURING LINE INSP, FOUND FUSELAGE STRINGER 16L DAMAGED AFT OF BS 620. REPAIRED IAW SRM 53-00-03 FIG 201, ERA 484616-14.SDR DALA1019225503Skin · dentedDURING LINE INSP, FOUND FUSELAGE SKIN DENTED AT BS 620 FWD, OF DOOR L2 AT S16L. REPAIRED IAW ERA 484616-14, REV A.SDR DALA1018305527Light · inoperativeDURING A LINE CHECK, MX FOUND THE DOOR 2R EMERGENCY EXIT LIGHT INOPERATIVE. MX REPLACED THE EXIT LIGHT ASSY. OPS CHECK WAS GOOD.SDR DALA1018135656Light · inoperativeDURING OVERNIGHT LINE CHECK FOUND EXTERIOR EMERGENCY LIGHT INOP AT DOOR 4L. REPLACED LIGHT ASSEMBLY.SDR DALA1018165636Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHTS AT ROWS 26-30 & 39 INOPERATIVE. MAINTENANCE RECHARGED THE BATTERY PACK. OPERATIONAL CHECK WAS GOOD.SDR DALA1018155636Battery Pack · dischargedDURING LINE CHECK MAINTENANCE FOUND 3 AFT GALLEY OVERHEAD EMERGENCY LIGHTS AND 1 AFT CARGO DOOR EMERGENCY LIGHT INOPERATIVE. MAINTENANCE RECHARGED THE BATTERY PACK. OPERATIONAL CHECK WAS GOOD.SDR DALA1017645636Battery Pack · inoperativeDOOR 1R EMERGENCY EXTERIOR LIGHT AND INSIDE EXIT LIGHT NOT ILLUMINATED. MX REPLACED BATTERY AND POWER SUPPLY IAW AMM. OPS TEST OK.SDR DALA1017415652Power Supply · inoperativeDOOR 4R EXTERIOR EMERGENCY LIGHT OUT. MAINTENANCE REPLACED POWER SUPPLY M736 PER AMM 33-51-07-022-017. OPS CHECKED GOOD.SDR DALA1016575527Battery Pack · dischargedEMERGENCY LIGHT MODULES INOPERATIVE AT BOTH AFT DOORS AT LOWER FORWARD CORNER. REPLACED AFT BATTERY PACK. CHECKED GOOD.SDR DALA1016575527QBattery Pack · dischargedEMERGENCY LIGHT MODULES INOPERATIVE AT BOTH AFT DOORS AT LOWER FORWARD CORNER. REPLACED AFT BATTERY PACK. CHECKED GOOD.SDR DALA1015745654Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHTS AT ROWS 20 - 24 INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AT ROW 23. OPERATIONAL CHECK WAS GOOD.SDR DALA1013145639Wire Harness · disconnectedDURING LINE CHECK, MX FOUND EMERGENCY PATH LIGHTS NEAR VCC INOPERATIVE. MX RECONNECTED LIGHT HARNESS. OPS CHECK WAS GOOD.SDR DALA1012795528Skin · damagedDURING LIGHTNING STRIKE INSPECTION, FOUND DAMAGE TO FUSELAGE SKIN AT BS 565 APPROX 1.5 INCHES ABOVE S3L. REPAIRED IAW SRM 53-00-01 FIG 201.SDR DALA1012785528Skin · damagedDURING LIGHTNING STRIKE INSPECTION, FOUND DAMAGE TO FUSELAGE SKIN AT BS 632 APPROX 2 INCHES ABOVE S3L. REPAIRED IAW SRM 53-00-01, FIGURE 201.SDR DALA1012775528Skin · damagedDURING LIGHTNING STRIKE INSP, FOUND DAMAGE TO FUSELAGE SKIN AT BS 593 APPROX 2.5 INCHES ABOVE S3L. REPAIRED IAW SRM 53-00-01, FIG 201.SDR DALA1012245520Battery Pack · inoperativeOVERHEAD EMERGENCY EXIT SIGN FWD OF LAV D INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY AT DOOR 3R IAW AMM. OPS CHECK OK.SDR DALA1012235650Wire · disconnectedEMERGENCY LIGHT AT SEAT 6B WILL NOT ILLUMINATE. FOUND WIRE DISCONNECTED AT CONNECTOR. REPLACED SEAT-MOUNTED LIGHT ASSY. OPS CHECKED OK.SDR DALA1012125635Oven · odorDURING FLIGHT, CREW FOUND FWD GALLEY OVENS EMITTED AN ELECTRICAL FIRE ODOR. CREW PULLED THE OVEN CIRCUIT BREAKERS AND THE ODOR SUBSIDED. MX FOUND THE TRIPLE OVEN WITH A BURNED ODOR AND REPLACED SAME. OPS CHECK WAS GOOD.SDR DALA1011455646Light · inoperativeDURING LINE CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT SEAT 23 ABC INOPERATIVE. MX REPLACED THE LIGHT ASSY. OPS CHECK WAS GOOD.SDR DALA1011445521Wire · chafedDURING CRUISE AND IN SMOOTH AIR, ALL CABIN EMERGENCY LIGHTS FLICKERED ON AND OFF. MX REPAIRED CHAFED WIRING NEAR DOOR 2L. OPS CHECK WAS GOOD.SDR DALA1011435521Power Supply · malfunctionedDURING FLIGHT, F/A'S REPORTED EMERGENCY LIGHTS FWD OF DOOR 3 FLICKERING ON AND OFF. MX COULD NOT DUPLICATE AND CHANGED THE POWER SUPPLY. OPS CHECK WAS GOOD.SDR DALA1011255650Battery Pack · inoperativeDURING LAYOVER CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT ROWS 16-19 INOPERATIVE. MX REPLACED THE BATTERY PACK AND CHARGER. OPS CHECK WAS GOOD. REF ADDITIONAL LOG 0233561.SDR DALA1011225519Acm · odorONE HOUR INTO THE FLIGHT, CREW NOTED BURNING ODOR IN THE COCKPIT. ACFT RETURNED. MX CHECKED MULTIPLE SYSTEMS AND REPLACED THE LT ACM.SDR DALA1010965521Switch · faultyFLIGHT CREW REPORTS THE CABIN EMERGENCY LIGHTS CYCLE ON AND OFF WHEN ARMED. MX REPLACED THE F/A ARMING SWITCH. OPS CHECK WAS GOOD.SDR DALA1010955646Wire · damagedDURING LAYOVER CHECK, MX FOUND EMERGENCY PATH LIGHT AT SEAT 30L INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD.SDR DALA1010515647Wire Harness · damagedDURING LAYOVER CHECK, MX FOUND THE DR1L VCC AREA EMERGENCY PATH LIGHTS INOPERATIVE. MX REPAIRED THE LIGHT HARNESS. OPS CHECK WAS GOOD.SDR DALA1010025502Circuit Breaker · trippedEMERGENCY LIGHTS FROM DOOR 2 AFT ILLUMINATED. FOUND EMERGENCY CHG RT P11-N35 CIRCUIT BREAKER OPEN. RESET CIRCUIT BREAKER AND PERFORMED OPS TEST OF EMERGENCY LIGHTS IAW AMM 33-51-00-50. OK FOR SERVICE.SDR DALA1010035646Battery Pack · inoperativeFOUND LT ROW SEATS 36-40 EMERGENCY ESCAPE PATH LIGHTING AND AISLE OVERHEAD BIN WOULD NOT ILLUMINATE DURING TEST. REPLACED BATTERY AND POWER SUPPLY IAW AMDS 33-51-07-201-925A-A.SDR DALA1010005531Skin · damagedDURING LINE CHECK FOUND DAMAGE TO FUSELAGE SKIN AT BS 1475 S10L. REPAIRED IAW SRM 53-00-01, FIGURE 201 AND ERA 482513-14.SDR DALA109805638Power Supply · inoperativeBUSINESS CLASS EMERGENCY LIGHT AT LEFT OVERHEAD BIN AREA INOPERATIVE. REPLACED POWER SUPPLY ASSEMBLY.SDR DALA109505637Light · disconnectedDURING LAYOVER CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHT AT SEAT 22C INOPERATIVE. MAINTENANCE RECONNECTED THE PATH LIGHT. OPERATIONAL CHECK WAS GOOD.SDR DALA109165523Floor Support · corrodedDURING LINE CHECK FOUND CORROSION ON AFT CARGO DOOR THRESHOLD FLOOR SUPPORT FROM AFT EDGE OF DOOR TO FWD EDGE. REPAIRED IAW SRM 51-40-02, 51-20-01.SDR DALA108955656Lamp · inoperativeEXTERIOR SLIDE LIGHTS AFT OF DOORS 2R AND 4L INOPERATIVE. RELAMPED BOTH LIGHTS. LOG PAGE 7065081 FOR DOOR 4L.SDR DALA108945648Power Supply · inoperativeROW 34 TO 38 EMERGENCY LIGHTS INOPERATIVE. FOUND AFT GALLEY OVERHEAD POWER SUPPLY INOPERATIVE. REPLACED POWER SUPPLY IAW MM.SDR DALA108895521Power Supply · defectiveDURING FLIGHT, EMERGENCY SIGNS AND PATH LIGHTS CAME ON INTERMITTENTLY. MAINTENANCE REPLACED THE POWER SUPPLY. OPERATIONAL CHECK WAS GOOD.SDR DALA108885521Light · inoperativeDURING FLIGHT, EMERGENCY OVERHEAD AND FLOOR LIGHTS COME ON INTERMITTENTLY. MAINTENANCE REPLACED THE EMERGENCY LIGHT SWITCH AT THE FLIGHT ATTENDANT PANEL. OPERATIONAL CHECK WAS GOOD.SDR DALA107845526Battery Pack · inoperativeDOOR 2R OVERHEAD EMERGENCY LIGHT DOES NOT ILLUMINATE. REPLACED EMERGENCY LIGHT BATTERY.SDR DALA107835526Battery Pack · looseDOOR 3R OVERHEAD EMERGENCY LIGHT DOES NOT ILLUMINATE. FOUND SIGN BATTERY PACK LOOSE. TIGHTENED BATTERY. OPS CHECKED GOOD.SDR DALA107825526Power Supply · inoperativeEMERGENCY SEAT LIGHT INOPERATIVE. REPLACED POWER SUPPLY IAW AMM 33-51-07. OPS CHECKED GOOD.SDR DALA107375645Lamp · inoperative2 EXTERIOR EMERGENCY EGRESS LIGHTS INOP AT LT WING (L562, L568). RELAMPED BOTH LIGHTS, CK OK.SDR DALA107125503Power Supply · inoperativeEMERGENCY EGRESS LIGHTING INOP AT CTR AISLE EXIT SIGN BETWEEN DOOR 3R & 3L, AND OUTSIDE DOOR 3L. REPLACED POWER SUPPLY M735, OPS CKS OK.SDR DALA107135521Battery Pack · inoperativeEMERGENCY EGRESS LIGHTING FOUND INOP ON OVERNIGHT AT DOOR 2L, DOOR 3L AND ROWS 30, 31. REPLACED PWR SUPPLY AND BATTERY PACKS M732 AND M735, OPS CHECKS OK.SDR DALA106855652Unknown · odorINFLIGHT, F/AS REPORT "BURNING RUBBER SMELL" BETWEEN ROWS 21 AND 6. F/A PULLED GALLEY 2 CIRCUIT BREAKERS. SMELL SUBSIDED TO A POINT WHERE IT WAS NO LONGER NOTICEABLE THROUGHOUT REMAINDER OF FLIGHT. REPLACED RT RECIRCULATION FAN, LT AND RT FILTERS, AND ALL 4 CSDR DALA106845644Battery Pack · inoperativeEXTERIOR SLIDE EMERGENCY LIGHT AFT OF 4R DOOR INOPERATIVE. REPLACED POWER SUPPLY M736 AND BATTERY PACK. LIGHT OPERATION NORMAL.SDR DALA13070035657Skin · damagedFUSELAGE EXTERIOR EXPIERENCED A LIGHTNING STRIKE, DAMAGE IS OUT OF LIMITS, CONTAINED DAMAGE, PERFORMED HFEC OPEN HOLE AND SURFACE SCAN NO CRACKS INDICATED. ALODINED AND PRIMED AREA. SHOT BLIND RIVET AND RESTORED TOP COAT PAINT IAW SRM 53-00-01, PG 201, FIG SDR DALA105375649Skin · dentedDURING CHECK FOUND LEFT SIDE EXTERIOR FUSELAGE DENTED AT STA 774, STRINGER 16L. CUT OUT AND REPLACED DAMAGED AREA. PER SRM 53-00-01.
Back to Boeing 757-251