Boeing 757-2S7
Service difficulty reports · 1,282
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572S7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572S7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA200301501Battery · dischargedDURING INSPECTION FOUND THE L-1 DOOR EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE L-1 DOOR EMERGENCY EXIT LIGHT BATTERY POWER SUPPLY (M731), OPERATIONAL CHECK WAS GOOD.SDR AWXA200301490Housing · damagedDURING INSPECTION FOUND THE EMERGENCY ESCAPE PATH LIGHTS SEAT ROWS 1-8 INOPERATIVE. MAINTENANCE REMOVED AND REPLACED BULLNOSE LIGHT HOUSING BETWEEN SEAT ROWS 6-8, OPERATIONAL CHECK WAS GOOD.SDR AWXA200301479Light · inoperativePHX - EEL - DURING INSPECTION THE EMERGENCY ESCAPE PATH LIGHT AT SEAT ROW 11 LT WAS FOUND INOPERATIVE. MAINTENANCE REMOVED AND REPLACED EMERGENCY ESCAPE PATH LIGHT ASSEMBLY AT SEAT ROW 11 LT, OPERATIONAL CHECK WAS GOOD.SDR AWXA200301461Panel · looseON TAKEOFF ROLL AT LAS EN ROUTE FOR JFK THE TOWER ADVISED FLIGHT CREW A PANEL WAS OPEN, TAKEOFF WAS REJECTED AT LOW SPEED. TAXIED BACK TO RAMP AND MAINTENANCE SECURED THE FORWARD GROUND POWER PANEL. TAXIED BACK TO RUNWAY, DEPARTED WITHOUT FURTHER EVENT.SDR AWXA200301393Light · intermittentPHX - EEL - DURING INSPECTION FOUND AN INTERMITTENT EMERGENCY ESCAPE PATH LIGHT AT SEAT ROW 23 LT. MAINTENANCE REMOVED AND REPLACED EMERGENCY ESCAPE PATH LIGHT ASSEMBLY AT SEAT ROW 23 LT, OPERATIONAL CHECK WAS GOOD.SDR AWXA200301375Indicator · failedSJD - ABORTED TAKEOFF - FLT 0052 - ON TAKEOFF AT SJD EN ROUTE FOR PHX THE CAPTAINS AIRSPEED INDICATOR FAILED, REJECTED TAKEOFF AT 85 KTS. MAINTENANCE PERFORMED BACKFLOW OF STATIC DRAIN LINES, NO MOISTURE NOTED, PERFORMED AIR DATA COMPUTER BITE TEST, SYSTEM OPSDR AWXA200301345Battery · dischargedPHX - EMERGENCY EQUIPMENT - FLIGHT CREW REPORTED THE EMERGENCY FLASHLIGHT AT L-2 DOOR WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED BATTERIES IN THE L-2 DOOR EMERGENCY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.SDR AWXA200301405Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM AT NUT PLATES BETWEEN BS 1500 TO BS 1510, LBL 14. MAINTENANCE REMOVED CORRODED FLOORBEAM CAP BETWEEN BS 1500 TO BS 1510, LBL 14; FABRICATED A NEW REPLACESDR AWXA200301401Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND AT NUT PLATES ON AFT CARGO COMPARTMENT FLOORBEAM FROM BS 1503 TO BS 1513, RBL 9. MAINTENANCE REMOVED CORRODED SECTION OF FLOORBEAM FROM BS 1503 TO BS 1513, RBL 9; FABRICATED 2 EACH FILLERSSDR AWXA200301362Support Angle · corrodedDURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON AFT SHEAR DECK LOWER SUPPORT ANGLE BS 1701-1720, LBL 45. MAINTENANCE REMOVED DAMAGED AFT SHEAR DECK LOWER SUPPORT ANGLE FROM BS 1701 TO BS 1720, LBL 45; FABRICATED A NEW REPLACEMENT ANGLE PER DWG 146N5323SDR AWXA200301359Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AT NUT PLATES ON AFT CARGO COMPARTMENT FLOORBEAM BS 1502-1517, RBL 2. MAINTENANCE REMOVED DAMAGED SECTION OF CARGO FLOORBEAM FROM BS 1502 TO BS 1517, RBL 2; FABRICATED A REPAIR ANGLE & FSDR AWXA200301357Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AT NUT PLATES ON AFT CARGO COMPARTMENT FLOORBEAM BS 1503-1540, LBL 2. MAINTENANCE REMOVED DAMAGED SECTION OF CARGO FLOORBEAM FROM BS 1503 TO BS 1540, LBL 2; FABRICATED A REPLACEMENT FLOOSDR AWXA200301356Floorbeam · crackedLCQ - MAJOR REPAIR - DURING C-09 CHECK A .5625 INCH CRACK WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM BS 1600, LBL 2. MAINTENANCE REMOVED DAMAGED SECTION OF CARGO FLOORBEAM FROM BS 1545 TO BS 1640, LBL 2; FABRICATED A REPAIR CHANNEL; INSTALLED REPAIR PART IASDR AWXA200301355Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AT NUT PLATES ON LOWER SIDE OF AFT CARGO COMPARTMENT FLOORBEAM BS 1500 TO BS 1540, LBL 9. MAINTENANCE REMOVED DAMAGED SECTION OF CARGO FLOORBEAM FROM BS 1500 TO BS 1540, LBL 9; FABRICATESDR AWXA200301354Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND AROUND NUT PLATES HOLES OF AFT CARGO COMPARTMENT FLOORBEAM BS 1624 TO BS 1638, RBL 14. MAINTENANCE REMOVED CORRODED SECTION OF FLOORBEAM UPPER CAP AT BS 1624 TO BS 1638, RBL 14; FABRICATEDSDR AWXA200301352Web · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FORMER WEB AT LOWER PORTION OF WEB WHERE ATTACHED TO SKIN BS 1500 TO BS 1520. MAINTENANCE REMOVED DAMAGED FORMER WEB FROM BS 1500 TO BS 1520; FABRICATED A NEW RESDR AWXA200301404Support Bracket · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM SUPPORT BRACKET BS 1310, RBL 14. MAINTENANCE REMOVED CORRODED FLOORBEAM SUPPORT BRACKET BS 1310, RBL 14; FABRICATED A NEW REPLACEMENT BRACKET; INSTALLESDR AWXA200301403Support Bracket · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM SUPPORT BRACKET BS 1310, LBL 14. MAINTENANCE REMOVED CORRODED FLOORBEAM SUPPORT BRACKET BS 1310, LBL 14; FABRICATED A NEW REPLACEMENT BRACKET; INSTALLED SDR AWXA200301402Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON LOWER SURFACE OF AFT CARGO COMPARTMENT FLOORBEAM BS 1474, RBL 9. MAINTENANCE REMOVED CORRODED SECTION OF FLOORBEAM FROM BS 1474, RBL 9; FABRICATED REPAIR ANGLES; INSTALLED REPAIR PARTS SDR AWXA200301361Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND AT NUT PLATES ON AFT CARGO COMPARTMENT FLOORBEAM BS 1320, LBL 2. MAINTENANCE REMOVED DAMAGED SECTION OF CARGO FLOORBEAM FROM BS 1215 TO BS 1320, LBL 2; FABRICATED A REPLACEMENT FLOORBEAM ASDR AWXA200301360Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM BS 1460-1480, RBL 18. MAINTENANCE REMOVED DAMAGED T-ANGLE AND ATTACH BRACKETS FROM BS 1460-1480, RBL 18; FABRICATED A NEW REPLACEMENT ANGLE AND ATTACH SDR AWXA200301358Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND AT NUT PLATES ON AFT CARGO COMPARTMENT FLOORBEAM BS 1470, LBL 2. MAINTENANCE REMOVED DAMAGED SECTION OF CARGO FLOORBEAM BS 1470, LBL 2; FABRICATED A REPAIR ANGLE & FILLER; INSTALLED REPAIRSDR AWXA200301353Web · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FORMER WEB BS 1420, LBL 2. MAINTENANCE REMOVED DAMAGED FORMER WEB FROM BS 1420, LBL 2; FABRICATED A NEW REPLACEMENT WEB; INSTALLED REPAIR PART IAW B757-200 SRM 51-SDR AWXA200301351Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON NUT PLATES LOWER SIDE OF AFT CARGO COMPARTMENT FLOORBEAM BS 1304 TO BS 1312, LBL 2. MAINTENANCE REMOVED DAMAGED FLOORBEAM FROM BS 1215 TO BS 1320, LBL 2; FABRICATED A NEW REPLACEMENT FLSDR AWXA200301349Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON NUT PLATES LOWER SIDE OF AFT CARGO COMPARTMENT FLOORBEAM BS 1470, RBL 20. MAINTENANCE REMOVED DAMAGED FLOORBEAM FROM BS 1440 TO BS 1500, RBL 20; FABRICATED A NEW REPLACEMENT FLOORBEAM; SDR AWXA200301295Floorbeam · corrodedDURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM AT BS 1470, RBL 2. MAINTENANCE REMOVED DAMAGED AREA OF FLOORBEAM BETWEEN BS 1450 AND BS 1480, RBL 2; FABRICATED 4 EACH REPAIR ANGLES AND 2 EACH CHANNELS; INSTALLED REPAIR PARSDR AWXA200301294Floorbeam · corrodedDURING C-09 CHECK EXFOLIATION CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM AT BS 1320 AND BS 1330, RBL 2. MAINTENANCE REMOVED DAMAGED AREA OF FLOORBEAM BETWEEN BS 1235 AND BS 1340, RBL 2; FABRICATED A NEW REPLACEMENT SECTION OF FLOORBEAM AND REPAIR SDR AWXA200301293Floorbeam · corrodedDURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM AT BS 1330, RBL 14. MAINTENANCE REMOVED DAMAGED AREA OF FLOORBEAM AT BS 1330, RBL 14; FABRICATED REPAIR ANGLES AND A FILLER; INSTALLED REPAIR PARTS IAW B757-200 SRM 51-70-1SDR AWXA200301292Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON AFT CARGO COMPARTMENT FLOORBEAM AT BS 1362, RBL 14. MAINTENANCE REMOVED DAMAGED AREA OF FLOORBEAM BETWEEN BS 1343 AND BS 1365, RBL 14; FABRICATED 4 EACH REPAIR ANGLES & 2 EACH CHANNELSDR AWXA200301178Support Angle · crackedLCQ - MINOR REPAIR - DURING C-09 CHECK A .625 INCH CRACK WAS FOUND ON NR 1 ENGINE PYLON FORWARD OUTBOARD SUPPORT ANGLE. MAINTENANCE REMOVED CRACKED FORWARD OUTBOARD SUPPORT ANGLE; FABRICATED A NEW REPLACEMENT SUPPORT ANGLE PER DWG 311N5002; INSTALLED REPAIR PSDR AWXA200301181Pan · crackedDURING C-09 CHECK 3 EACH CRACKS WERE FOUND AT MOUNT HOLES ON EXTERNAL POWER PANEL PAN ASSEMBLY BS 419. MAINTENANCE PERFORMED HFEC INSPECTION TO VERIFY CRACK ENDS; STOP DRILLED CRACKS; RE-ACCOMPLISHED HFEC INSPECTION TO VERIFY CRACKS CONTAINED; PERFORMED WELD SDR AWXA200301177Floor Support · crackedDURING C-09 CHECK 3 EACH CRACKS WERE FOUND AT FASTENER HOLES ON CABIN FLOOR SUPPORT ANGLE BETWEEN BS 1200 TO BS 1210, BL 0. MAINTENANCE REMOVED CRACKED FLOOR SUPPORT ANGLE AT BS 1200 TO BS 1210, BL 0; FABRICATED A NEW REPLACEMENT ANGLE; INSTALLED REPAIR PART SDR AWXA200301195Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL K-3 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 146N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301194Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL T-3 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 146N5750, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301193Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL M-5 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 144N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301192Stringer · corrodedDURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AROUND NUT PLATE HOLES ON FLOOR STRINGER IN AFT CARGO COMPARTMENT BS 1280 TO BS 1360, LBL 18 TO RBL 20. MAINTENANCE CUTOUT CORRODED AREAS OF FLOOR STRINGER BS 1280 TO BS 1360, LBL 18 TO RBL 20; FABRICATED RESDR AWXA200301191Stringer · corrodedDURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AROUND NUT PLATE HOLES ON FLOOR STRINGER IN AFT CARGO COMPARTMENT BS 1500 TO BS 1560, LBL 18 TO RBL 18. MAINTENANCE CUTOUT CORRODED AREAS OF FLOOR STRINGER BS 1500 TO BS 1560, LBL 18 TO RBL 18; FABRICATED RESDR AWXA200301190Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL K-4 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 144N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301189Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL N-2 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 146N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301188Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL N-5 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL PER DWG 146N5330, AND INSTALLED INSERTS IAW AWA ER 19-5322-03267-SS1.SDR AWXA200301187Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL M-2 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL PER DWG 144N5330, AND INSTALLED INSERTS IAW AWA ER 19-5322-03267-SS1.SDR AWXA200301186Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL K-2 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL PER DWG 144N5330, AND INSTALLED INSERTS IAW AWA ER 19-5322-03267-SS1.SDR AWXA200301185Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL L-1 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL PER DWG 144N5330, AND INSTALLED INSERTS IAW AWA ER 19-5322-03267-SS1.SDR AWXA200301184Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL K-1 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL PER DWG 144N5330, AND INSTALLED INSERTS IAW AWA ER 19-5322-03267-SS1.SDR AWXA200301183Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL S-6 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL PER DWG 146N5750, AND INSTALLED INSERTS IAW AWA ER 19-5322-03267-SS1.SDR AWXA200301182Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL P-6 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL PER DWG 146N5750, AND INSTALLED INSERTS IAW AWA ER 19-5322-03267-SS1.SDR AWXA200301180Support Angle · crackedLCQ - MAJOR REPAIR - DURING C-09 CHECK A .75 INCH CRACK WAS FOUND ON SUPPORT BRACKET UNDER RT WING TO BODY FAIRING AT BS 1300, STR 21 RT. MAINTENANCE CUT OUT DAMAGE ON SUPPORT BRACKET UNDER RT WING TO BODY FAIRING AT BS 1300, STR 21 RT; PERFORMED HFEC INSPECTSDR AWXA200301179Support Angle · crackedLCQ - MAJOR REPAIR - DURING C-09 CHECK A 1.25 INCH CRACK WAS FOUND ON SUPPORT BRACKET UNDER RT WING TO BODY FAIRING AT BS 1300, STR 25 RT. MAINTENANCE CUT OUT DAMAGE ON SUPPORT BRACKET UNDER RT WING TO BODY FAIRING AT BS 1300, STR 25 RT; PERFORMED HFEC INSPECSDR AWXA200300766Actuator · defectiveDURING EMERGENCY DESCENT AFTER MANUAL DEPLOYMENT OF OXYGEN MASKS, SEVERAL MASKS FAILED TO DEPLOY. FLIGHT ATTENDANT MANUALLY DEPLOYED MASKS AT SEAT ROW 2, 4 & 12 AND LAVATORIES A & C. MAINTENANCE REPLACED SOLENOIDS (ACTUATORS) AT SEAT ROWS 2, 4 & 12 AND LAVATSDR AWXA200300765Duct · blownON CLIMBOUT AT FL 190 HEARD A LOUD BANG AND FELT AIRCRAFT SHUDDER. CHECKED PRESSURIZATION AND FOUND OUTFLOW VALVE WAS IN FULL CLOSED POSITION, CABIN PRESSURE WAS CLIMBING. MANUALLY DEPLOYED OXYGEN MASKS & MADE EMERGENCY DESCENT. DECLARED EMERGENCY & TURNED
Back to Boeing 757-2S7