Boeing 757-33N
Service difficulty reports · 1,195
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75733N' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75733N' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AMTA200700262Anti-Ice Valve · unserviceableEICAS MSG LT ENG ANTI-ICE DISPLAYED AND ENGINE ANTI-ICE VALVE LIGHT. REMAINED ILLUMINATED WITH SWITCH ON. REMOVED AND REPLACED LT ENG ANTI-ICE VALVE IAW AMM 30-21-03-4. OPS CHECK NORMAL. (K)SDR AMTA200700261Transceiver · unknownLT HF RADIO RECEPTION INOPERATIVE AT ALL CREW STATIONS. COULD NOT DUPLICATE ON GROUND IAW MM 23-11-00. SWAPPED HF TRANCEIVER LT SN: 01412 WITH R/T TRANCEIVER SN: 01427 FOR FURTHER T/S. CONTACTED SFO AT FREQ. 5574. TRANS. 4 X 4. OK FOR SERVICE. (K)SDR AMTA200700259Sensor · out of adjustGIRT BAR ENGAGEMENT LIGHT EXTINGUISHES WITH EVACUATION SLIDE ARMING LEVER IN ARMED POS, AT ENTRY 1L. PERFORMED FIM 25-66-00. ADJUSTED CLEARANCE BETWEEN THE GIRT BAR SLIDER AND THE SENSOR IAW MM 25-66-11. CLEANED AND LUBRICATED GIRT BAR. OPS CHECKED GOOD. (SDR AMTA200700234Generator · unserviceableON ENG STARTUP (LEFT) GENERATOR DRIVE LIGHT COMES ON. REMOVED AND REPLACED NR 1 IDG IAW M-SHEET M57-24-01 AND AMM 24-11-01-4. OPS CHECK GOOD NO LEAKS NOTED. (K)SDR AMTA200700233Heater · inoperativeRT FWD WINDOW HEAT INOPERATIVE LIGHT ILLUMINATES INTERMITTENTLY AFTER LANDING. COULD NOT DUPLICATE WINDOW HEAT INOPERATIVE ON GROUND, NO EICAS MSG APPEARED, PERFORMED WINDOW HEAT BITE IAW FIM 30-41-00, RECYCLE POWER SEVERAL TIMES, OPS NORMAL. (K)SDR AMTA200700206Warning System · malfunctionedEICAS MESSAGE L ENG BLEED, OFF LIGHT ILLUMINATED. RAN LT ENGINE, OPS CHECKED LT ENGINE BLEED REF MM 36-11-00. NO DEFECTS NOTED, BLEED OPERATION NORMAL. (K)SDR AMTA200700204Anti-Ice Valve · faultyEICAS MSG R ENG ANTI-ICE DISPLAYED AND ENG ANTI-ICE VALVE LIGHT REMAINED ILLUM W/SW. ON R ENG ANTI-ICE CB WAS TRIPPED. RESET CB W/SW OFF. EICAS MSG AND VALVE LIGHT EXTINGUISHED. R ENG A/I WORKED NORMAL ON REPLACED ENGINE ANTI-ICE VALVE RAN ENGINE ANTI-ICE VSDR AMTA200700196Anti-Ice Valve · malfunctionedRT ENG ANTI-ICE VALVE SLOW TO OPEN. VALVE OPENED WHEN SWITCH RECYCLED. REPLACED RT ENGINE INLET THERMAL ANTI-ICE VALVE IAW MM 30-21-03. OPS CHECK NORMAL. (K)SDR AMTA200700188Oil Cooler · unknownAPU AUTO SHUTDOWN. RESTART UNSUCCESSFUL. (K) REMOVED AND REPLACED OIL COOLER. LEAK CHECK GOOD. APU CHECKS GOOD. (K)SDR AMTA200700186Coupler · damagedLT HF TRANSMISSION AND RECEPTION WEAK AND INTERMITTENT. REMOVED AND REPLACED LEFT HF COUPLER IAW MM 23-11-01-4, OPS CHECKS GOOD AT THIS TIME, TRANS AND RECEPTION LOUD AND CLEAR. (K)SDR AMTA200700150Warning System · malfunctionedAFTER BLOCK OUT APU GEN OFF LIGHT ILLUMINATED, RESENT TURNED OFF GEN LIGHT AND APU DOOR EICAS MSG APPEARED. RESET CB APU BATT BUS. PERFORMED APU BITE IAW FIM 49-11-00, FIG 103, NO FAULTS. RAN APU NO DEFECTS FOUND. APU DOOR CLOSES ON SHUTDOWN. (K)SDR AMTA200700145Starter · faultyAPU FAILED TO START 10 PERCENT RPM, 756 ECU FAULT (ABORTED START). APU COPARTMENT FULL OF ELECTRICAL SMOKE. REMOVED AND REPLACED APU STARTER IAW AMM 49-41-01, OPS CHECK NORMAL. (K)SDR AMTA200700144Hf Comm · malfunctionedLT HF WILL NOT TUNE OR TRANSMITT. RECEPTION NORMAL. PERFORMED STATIS BITE CHECK OF LT HF TXCR IAW FIM 23-11-00. NO FAULTS NOTED PERFORMED A STATIS COMMS CHECK OF LT HF SYSTEM. OPS CHECK GOOD. (K)SDR AMTA200700134Apu · malfunctionedAPU INOPERATIVE. PERFORMED BITE ON ECU, FOUND 2 ABORTED STARTS AND 1 DOOR SYSTEM FAULT. RAN APU SEVERAL TIMES APU RAN FINE NO FAULTS. (K)SDR AMTA200700135Coupler · unserviceableLT TRANSMISSION INTERMITTENT AT ALL CREW STATIONS. REMOVED AND REPLACED LT HF COUPLER IAW MM. INSTALLATION TEST NORMAL. (K)SDR AMTA200700064Bypass Valve · unserviceableAPU CONTINUALLY SHUTS DOWN. AFTER REMOVAL AND REPLACEMENT OF COOLER BYPASS VALVE, INSPECTED ALL CHIP DETECTORS AND FILTER BYPASS PINS. ALL CKD GOOD. RAN APU UNLOADED FOR 20 MIN. NO FAULTS. RAN APU 45 MIN UNDER ELEC AND PNEUMATIC LOAD. OPS CK GOOD. (K)SDR AMTA200700112Apu · shutdownAPU AUTO SHUTDOWN. OIL QTY, EICAS MSG (APU OIL QTY). REMOVED AND REPLACED APU IAW M57-49-02. OPS AND LEAK CHECKED GOOD. (K)SDR AMTA200700101Bottle · unserviceableRT EMERGENCY ESCAPE TEST LT IS ILLUMINATING (DIM) AT ALL TIMES. REPLACED RT EMER ESCAPE BOTTLE IAW AMM 25-65-02. CHECKS NORMAL. (K)SDR AMTA200700063Apu · unserviceableAPU OIL QTY WENT TO .50 AFTER 47 MIN INTO FLIGHT 27 MIN. ABOVE 20K CRUISE AT 35K. MANUALY SHUT APU DOWN. REMOVED AND REPLACED APU USING M57-49-02. OPS CHECK OK. (K)SDR AMTA200700061Apu · shutdownAPU HAD AUTO SHUTDOWN, FAULT LIGHT ILLUM, AND EICAS MSG, APU FAULT DISPLAYED. INTEROGATED APU (-19) AND CLEARED FAULTS. NO FAULTS DISPLAYED. (K)SDR AMTA200700056Generator · unserviceableON TAXI OUT LT GENERATOR DRIVE LIGHT ILLUMINATED. REMOVED AND REPLACED LT IDG IAW M57-24-01. SYSTEM CHECKS GOOD. (K)SDR AMTA200700057Generator · failedHMG WILL NOT PROVIDE ELECTRICAL POWER WHEN OPERATED. REMOVED AND REPLACED HMG IAW MM 24-25-02-4. HMG OPS GOOD. (K)SDR AMTA200700054Probe · unknownEICAS MSG LT ENG PROBE HEAT DISPLAYED. PERFORMED FIM 30-40-00 FIG 103, MSG CLEARED. (K)SDR AMTA200700053Valve · unserviceableLEVELED OFF AT CRUISE 20 MIN AFTER DEPARTURE, APU LEVELED OFF AT CRUISE 20 MIN AFTER DEPARTURE, APU OIL QTY SHOWED FULL. 30 MINUTES LATER OIL QTY SHOWED 50. REMOVED AND REPLACED GEARBOX PRESSURE REG VALVE IAW AMM 49-27-12-4. RAN APU 1 HR, APU OPS CHS NORMALSDR AMTA200700052Terminal · looseLT TURB OH DET 2 STATUS MSG DISPLAYED. DURING T/S FOUND LOOSE GROUND AND LOOSE TERMINAL CONNECTION FOR NR 2 TURBINE OVHT SWITCH, TIGHTENED CONNECTIONS. SYSTEM TESTED GOOD IAW AMM. (K)SDR AMTA200700051Unknown · unknownAPU AUTO SHUTDOWN DUE TO LOW OIL QTY APPROX 2 HOURS IN TO FLIGHT. INSPECTED APU OIL FILLER CAP, ALL LINES AND TAIL PIPE FOR SIGNS OF LEAK AND NO LEAKS WERE FOUND. RAN APU FOR 4 HOURS AND NO LEAKS WERE NOTED. PERFORMED BITE AND NO FAULTS FOUND. (M)SDR AMTA200700046Generator · unserviceableLT GEN DRIVE LGT DID NOT ILLUMINATE WITH ENGINE SHUTDOWN. REMOVED AND REPLACED LT ENG. IDG IAW M57-24-01. OPS CHECK AND LEAK CHECK GOOD. (K)SDR AMTA200700038Coupler · defectiveL HF INOPERATIVE, AT ALL CREW STATIONS. DOES NOT TUNE PROPERLY WHEN TRANSMIT BUTTON IS PUSHED, RADIO TRIES TO TUNE FOR ABOUT 20 SECONDS EACH TIME BUTTON IS PUSHED. REPLACED HF NR 1 SYSTEM COUPLER IAW AMM 23-11-01-4 PERFORMED SATISFACTORY INSTALLATION TEST. SDR AMTA200700019Anti-Ice Valve · malfunctionedEICAS MSG L ENG ANTI-ICE DISPLAYED AND ENG ANTI-ICE VALVE LIGHT REMAINED ILLUMINATED WITH SWITCH ON. REMOVED AND REPLACED LEFT ENGINE INLET TAI VALVE PER MM 30-21-03-4, OPS CHECKED NORMAL. (M)SDR AMTA200700012Ecu · failedAPU AUTO SHUTDOWN, SHOW REV FLOW LAST 3 SHUTDOWNS AND CODES 36 AND 43. REMOVED AND REPLACED APU ECU REF MM. OPS AND BITE CHECK GOOD. APU RUN NORMAL. (K)SDR AMTA200700004Proximity Switch · unknownSLIDE LIGHT OFF WITH BAR ENGAGED. REPLACED NR 4 LT DOOR AFT GIRT BAR PROX SWITCH IAW AMM 25-66-11-2. SLIDE LIGHT OPS CHECK NORMAL. (K)SDR AMTA200700001Actuator · unserviceableON LANDING ROLL OUT, LOST RT HYD SYSTEM. RT ENGINE IB THRUST REVERSER ACTUATOR LEAKING. REPLACED ACTUATOR, RESERVICED HYDRAULICS. OP NORMAL, NO LEAKS. (K)SDR AMTA200600746Engine · leakingPERFORMED RTO AT 90 KTS DUE MODERATE SMOKE IN COCKPIT. CHANGED LT ENG DUE TO OIL SEEP IN COLD STREAM. (K)SDR AMTA200600724Display · unknownWXR FAIL DISPLAYED ON HSI AND WXR TEST DISPLAYS WXR FAIL ANT. PERFORMED OPERATIONAL CHECK ON WXR RADAR SYSTEM CHECK GOOD IAW MM 34-43-00. (K)SDR AMTA200600677Idg · malfunctionedEICAS MESSAGE (L GEN DRIVE) DISPLAYED. GEN DRIVE LIGHT ILLUMINATED. GEN DRIVE DISCONNECTED. REPLACED NR 1 ENG IDG IAW W/C M57-24-01. (K)SDR AMTA200600636Sensor · faultyAPU AUTO SHUTDOWN WITH FAULT LIGHT ILLUMINATED IAW FIM 49-11-00 FIGURE 108, INSTALLED REPLACEMENT. LOAD COMPRESSOR INLET TEMP SENSOR IAW AMM 49-61-03, OPERATIONAL CHECK NORMAL. (K)SDR AMTA200600632Circuit Card · unserviceableSWAPPED LT AND RT AFOLTS CARDS, PROBLEM FOLLOWED CARD, RETURNED CARDS TO ORIGINAL POSITION. REPLACED RT ENG AFOLTS CARD (M10274) IAW AMM 26-10-01, BOTH ENG AFOLTS TEST NORMAL. (K)SDR AMTA200600631Wire · brokenEICAS MSG RT ENG OH LP 1 DISPLAYED DURING CRUISE. REPAIRED BROKEN WIRES AT RIGHT NACELLE OVERHEAT DETECTOR IAW MM 20-00-14. (M)SDR AMTA200600620Circuit Card · malfunctionedDURING CRUISE, INTERMITTENT STATUS MESSAGE DISPLAYED R ENG OH LP 1. REMOVED AND REPLACED AFOLTS CIRCUIT CARD M10274 PER MM 26-10-01-4. OPS CHECK GOOD PER MM 26-10-00-6. (M)SDR AMTA200600613Warning Light · illuminatedPRIOR TO TAXI AUTO SPD BRAKE LIGHT ILLUMINATED 27-62-10. REMOVED AND REPLACED AUTO SPEED BRAKE ACTUATOR IAW AMM 27-62-02. OPERATIONAL CHECKS GOOD. (M)SDR AMTA200600597Engine · malfunctionedON TAKEOFF EGT RAPIDLY ROSE BEYOND 855C HAD TO REDUCE POWER TO STAY WITHIN LIMITS ON CLIMB-OUT. CLIMB 2 SELECTED EGT 810C, N3 997 PERCENT COULD NOT HOLD MAX CONTINUOUS OR CLIMB POWER. (M)SDR AMTA200600572Overheat Loop · malfunctionedRIGHT ENGINE OVERHEAT LP1 STATUS MESSAGE ILLUMINATED ON CLIMB-OUT AND OUT ON DESCENT. REMOVED AND REPLACED RT ENGINE OVERHEAT LOOP ASSEMBLY AS REQUIRED. OPS CHECK NORMAL PER AMM 26-11-00. (M)SDR AMTA200600560Circuit Card · damagedRIGHT ENGINE OH LP1 DISPLAYED. SWAPPED FOR T/S RT ENGINE LOOP DET CARDS. RT ENGINE NR 1 LOOP CARD NOW P/N 6445-01, S/N 20757. RT ENGINE NR 2 LOOP CARD NOW P/N 6445-01, S/N 20730. BOTH RT ENGINE FIRE LOOPS. OPS CHECK NORMAL. (M)SDR AMTA200600555Indicator · poppedRIGHT ENGINE IDG FILTER BYPASS INDICATOR POPPED. REMOVED IDG SCAVENGE FILTER, NO MATERIAL FOUND IN FILTER OR IDG OIL. REPLACED FILTER IAW AMM 24-11-02. RESERVICED IDG OIL IAW AMM 12-13-03. REPLACED DIFF PRESS IAW AMM 24-11-01. OPS CHECK NORMAL. (M)SDR AMTA200600551Transceiver · unserviceableLEFT HF RADIO INOPERATIVE. REMOVED AND REPLACED LEFT HF RT IAW AMM. (K)SDR AMTA200600550Coupler · damagedRIGHT HF, DOES TRANSMIT, VERY WEAK AND GARBLED ON RECEIVING. REMOVED AND REPLACED RIGHT COUPLER IAW MM 23-11-01. OPS CHECK GOOD. (M)SDR AMTA200600549Transceiver · inoperativeFOUND LEFT HF, CANNOT TRANSIMIT OR RECEIVE. REMOVED AND REPLACED LEFT COUPLER IAW MM 23-11-01. OPS CHECK GOOD. (M)SDR AMTA200600536Shutoff Valve · malfunctionedFLT 7012 - "PACK OFF" LIGHT REMAINED ILLUMINATED FOR AROUND 1 MINUTE AFTER RIGHT PACK WAS ON:RUNNING. REMOVED AND REPLACED FLOW CONTROL AND SHUTOFF VALVE IAW AMM 21-51-01-2. OPS CHECK NORMAL, NO LEAKS NOTED. (M)SDR AMTA200600530Light · inoperativeR1 DOOR INTERIOR EGRESS EXIT LIGHT INOPERATIVE FWD OF DOOR. REPLACED LIGHT ASSY IAW AMM. (K)SDR AMTA200600524Starter · unserviceableAPU WILL NOT START, HANGS AT 22 PERCENT, EGT 700 DEG. REMOVED AND REPLACED APU STARTER IAW MM. PU OPS CHECK GOOD. (K)
Back to Boeing 757-33N