Boeing 767-306
Service difficulty reports · 2,510
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020122102600Aap · unknownAIRCRAFT PACKS EXCESSIVELY LOUD, W/BOTH PACKS ON THEY HAVE A LOUD WHISTLE. DURING DEPARTURE EVEN WITH VOLUME ALL THE WAY UP. ATC COULD BARELY BE UNDERSTOOD AND PILOTS HAD TO YELL AT EACH OTHER. CONT-WHISTLE WHENT AWAY AS WE CLIMBED THROUGH FL250, WHICH DROPSDR UIEA2020122102601Warning Message · false activationON DESCENT, "LT ENGINE BLEED OFF" EICAS. RAN QRH AND TURNED WING ANTI-ICE LT PACK OFF. PERFORMED ENGINE RUN OF LT ENGINE, FOUND ENGINE TO OPERATE NORMAL AT THIS TIME, IAW 767 M/M 71-00-00.SDR UIEA2020122102604Panel · openON POST FLIGHT INSPECTION, PANEL WAS FOUND OPEN. PERFORMED PNEUMATIC LEAK TEST, IAW BOEING 767 AMM 71-00-00. NO LEAK DETECTED. CLOSED PANEL, IAW BOEING 767 AMM 78-31-14.SDR UIEA2020122102599Charger · unknownAPU BATT CHARGER STATUS MESSAGE. R & R APU BATT CHARGER, PER AMM 24-31-05. OPERATIONS NORMAL AT THIS TIME, REF LP 1352703 ITEM 7 FOR APU COLD SOAK DMI.SDR UIEA2020122102603Status Message · false activationCARGO A/C TEMP STATUS MESSAGE. PERFORMED AUX ZONE TEMP CNT BITE, NO FAULT FOUND. CLEARED STATUS MESSAGE IAW 21-61-12.SDR UIEA2020121702592Status Message · false activationCARGO A/C TEMP STATUS. PERFORMED OPERATIONS CHECK, PER AMM 26-23-00. OPERATIONS CHECK GOOD.SDR UIEA2020121302550Status Message · false activationRT ENGINE SPEED CARD STATUS MESSAGE AFTER ENGINE START. PERFORMED FIM 73-21 F/T 871, SYSTEM IS OK. NO FURTHER FAULTS NOTED.SDR P5CA2020121400394Duct · damagedDURING APU MAINTENANCE FOUND APU SURGE VALVE DUCT DAMAGED. TRANSFERRED TO MDDR 139394, IAW DDG 49-11-01A, CAT C, DUE 22DEC20. REMOVED AND REPLACED APU SURGE BLEED DUCT, IAW AMM 20-11-00. APU OPERATIONS CHECK GOOD, NO DEFECTS NOTED AT THIS TIME, IAW AMM 49-1SDR UIEA2020120702535Status Message · false activationWXR STATUS MESSAGE. PERFORMED BITE, IAW FIM 34-43 SHEET 1 BLOCK 2. NO FAULTS NOTED.SDR UIEA2020120202504Circuit Card · malfunctionedAFTER ENGINE STARTED, RECEIVED PROBE HEAT EICAS CAUTION MESSAGE. MULTIPLE DISCREET LIGHTS, "CAPT PITOT", "R AUX PITOT" "L AOA". REMOVED AND REPLACED RT N2 SPEED CARD, IAW AMM 73-21-54. RAN BOTH ENGINES, IAW 71-00-00, NO FAULTS MESSAGE NOTED. OPERATIONS NORSDR UIEA2020120202502Accelerometer · malfunctionedDURING CLIMBOUT LPT VIB WAS ERRATIC, POINTER MOVED BETWEEN 0 AND 5.0 FOR APPROX ONE MINUTE. NO VIBRATION WAS FELT IN FLIGHT DECK VIBRATION IN CRUISE FAN 0.6 N2 0.9. ACCOMPLISHED ENGINE RUN OF BOTH ENGINES AND NO VIBRATIONS NOTED, REF AMM 71-00-00. OKAY FOR SDR UIEA2020120102500Condenser · inoperativeRT PACK INOPERABLE (AIR CONDITIONING PACKS - 200/300 (NOTIFY DISPATCH). ER RESTRICTED R-60. TRANSFERRED TO MDDR 138732, IAW MEL 21-51-01-01, CAT C. REMOVED AND REPLACED RT PACK CONDENSER, IAW AMM 21-51-10. OPERATIONS AND LEAK CHECK GOOD. NO FAULTS AT THISSDR UIEA2020112902469Status Message · false indicationMAIN CARGO LOOP 1 STAUS MESSAGE. TRANSFERRED TO MDDR 138670, PER MEL 26-16-02-01. DUE DATE 09 DEC 2020. T/S PER FIM 26-14-FT809. NO FAULTS NOTED AT THIS TIME. THIS CLEARS MDDR 138670.SDR UIEA2020113002475Fault Message · false activationAPU FAULT AFTER LANDING. REPEAT WRITE UP. PERFORMED BITE TEST OF APU ECU 49-11 FT 987, NO FAULTS NOTED. APU START TEST 49-11-00-201 NORMAL AT THIS TIME.SDR UIEA2020113002474Engine · power lossBELOW 5000 ON ARRIVAL AMBER IDLE DISAGREE MESSAGE DISRUPTED LT ENGINE WAS 28% WHEN RT ENGINE WAS 40%. PERFORMED LT & RT ENGINE PIMU BITE PROCEDURE 71-01-01 FT 810. NO FAULTS ON EITHER PIMU BITE. NO IDLE DISAGREE MESSAGE DISPLAYED NO FAULTS AT THIS TIME.SDR UIEA2020113002484Warning Message · intermittentINTERMITTENT EICAS LT ENGINE BLEED OFF IN DECENT. PERFORMED T/S, IAW FIM 3-10 F/T838 AND PERFORMED IDLE POWER ENGINE RUN, IAW AMM 71-00-00. OPERATIONS CHECK GOOD AT THIS TIME.SDR UIEA2020112002430Indication Sys · failedITEM 1-FUEL CONFIG EICAS. TOTALIZER VS. CALCULATED=3.1 THOUSAND POUNDS. TOTALIZER 3.1 THOUSAND LESS THAN CALCULATED INDICATION=SUSPECTED FUEL LEAK. PERFORMED BITE TEST ON FQIS, FOUND LM DENS CONTAM OR RESISTOR G AND LM COMPENSATOR CONTAMINATED G. STUCK LMSDR UIEA2020111902425Fire Detector · malfunctionedITEM 02-RT ENGINE FIRE LP 2 STATUS MESSAGE. R & R UPPER AFT ENGINE FIREWALL DETECTOR LOOP 2, IAW AMM 26-11-02. FAULT NO LONGER IN VIEW. PERFORMED ENGINE RUN RIGHT ENGINE, IAW AMM 72-00-00, NO DEFECTS NOTED.SDR UIEA2020111602398A/C Pack · noisyINFLIGHT (BOTH ENGINES ON) AND BOTH PACKS OPERATING, UNUSUALLY LOUD MAKING INTERCOM AND ATC EXTREMELY DIFFICULT, NOISE REDUCTION SIGNIFICANTLY REDUCED WHEN 1 PACK SELECTED OFF. SQUEALS NOTED W/ BOTH PACKS. PERFORMED ENGINE RUN, PACK OPERATION TO DETERMINE NOSDR UIEA2020111602401O-Ring · leakingDUE TO SUSPECTED FUEL LEAK PERFORMED GVI OF WINGS AND LT & RT ENGINE. FOUND LEAK ON RT ENGINE FUEL FILTER DP SWITCH. REMOVED AND REPLACED FUEL FILTER DP SWITCH O-RING, IAW 73-34-01. PERFORMED DRY MOTOR, IAW AMM 71-00-00, NO LEAKS NOTED. OPERATIONS CHECK NOSDR UIEA2020111602400Controller · malfunctionedCARGO A/C CONT EICAS MSG ON FINAL. COMPLIED WITH QRH. REMOVED AND REPLACED PACK FLOW AND CARGO A/C CONTROLLER, IAW AMM 21-51-24. OPERATIONS CHECK GOOD. NO FAULTS AT THIS TIME.SDR UIEA2020111602399A/C Pack · noisyOPERATING LEFT PACK UNUSUALLY LOUD WITH NORMAL DUCT PRESSURES OBSERVED. LOUD SQUEELING INTERMITTENT, COMMUNICATIONS BETWEEN PILOTS AND ATC AFFECTED, SELECTED LEFT PACK OFF. PERFORMED LT PACK INSPECTION, IAW AMM 21-51-00. NO LEAKS OR DEFECTS NOTED. PERFORMESDR UIEA2020111602403Unknown · noiseIMMEDIATELY AFTER TAKEOFF A DEAFENING ROAR MADE COMMUNICATIONS BETWEEN PILOTS AND BETWEEN PILOTS AND ATC ALMOST IMPOSSIBLE. UNABLE TO DETERMINE WHERE THE NOISE CAME FROM. ONCE THE CABIN DIFF PRESSURE REACHED 6.0 THE NOISE SLOWLY ABATED. GENERAL VISUAL OF AISDR UIEA2020111402391Stowage Box · inoperative1ST OBS SEAT MASK O2 INOPERABLE. TRANSFERRED TO MDDR 137721, PER MEL 25-11-02-01C CAT A, DUE 14 NOV 20. REMOVED AND REPLACED STOWAGE, PER AMM35-11-51. OPERATIONS CHECK GOOD. NO LEAKS NOTED THIS CLEARS MDDR 137721. PLACARD REMOVED.SDR UIEA2020111202384Warning Message · false activationFWD EQUIPMENT VALVE ON EICAS AFTER LANDING, COMPLETED QRH CHECKLIST. PERFORMED FIM TASK 21-58 FT 985, NO MESSAGE OR OTHER FAULTS AT THIS TIME.SDR UIEA2020110902367None · noneINFO ONLY: RT ENGINE NO START FIRST ATTEMPT ON SINGLE IGNITOR. START OK ON BOTH. PERFORMED RT ENGINE IGNITION SYSTEM AUDIBLE TEST, IAW AMM 74-00-00. OPERATIONS CHECK GOOD, IGNITORS OPERATE NORMAL.SDR UIEA2020110602359Warning Message · false activation"APU FAULT" EICAS UPON ATTEMPTING APU START ON GROUND. PERFORMED ECU BITE, IAW B767 FIM 49-11 FT 987. NO FAULTS THEN PERFORMED APU START, IAW B767 AMM 49-11-00, NO FAULTS. APU OPERATIONS NORMAL, APU STARTED FIRST ATTEMPT.SDR P5CA2020110900376Shutoff Valve · warning messageLT ENGINE HPSOV STATUS MESSAGE. T/S IN REF TO FIM 36-10/833, LT HPSOV THUMB TEST OK VALVE SWITCHES WRANG. CHECKED FOUND 28V AT HPC-OK. CLEANED AND RE-CONNECTED PLUG AT HPC, LT SYSTEM PNEU OPERATIONS CHECKS, OK DURING ENGINE RUN, PER AMM 36-11-00.SDR UIEA2020110402345Apu · sparksDURING GROUND OPERATIONS MAINTENANCE WITNESSED SPARKS COMING OUT OF APU TAIL PIPE. MAINTENANCE SHUT DOWN APU AND PLACED ON DEFERRAL 49-11-01, MDDR 137202, CAT C. RAN APU IAW BITE TEST, PER FIM 49-11 FT 987, NO FAULTS NOTED. RAN BOTH PACKS, PER AMM 21-00-00.SDR UIEA2020110502355Module · inoperativeEICAS MESSAGE: LT ENGINE BLEED OFF AND LT ENGINE BLEED OFF LIGHT ILLUMINATED. FOUND LT ENGINE BLEED CNT POPPED AND HP CONT FAULT ON AIR SUPPLY MODULE BITE. RESET MODULE AND BREAKER PERFORMED IDLE ENGINE RUN, NO FAULTS NOTED, IAW AMM 36-23-01 AND 71-00-00.SDR P5CA2020110300370Module · failedLEFT ENGINE FUEL VALVE LIGHT INOPERABLE. TRANSFERRED TO MDDR 137160, IAW MEL 73-21-03-01, CAT: C EXP: 13NOV20 MX PROCEDURE COMPLIED WITH. MZ AT 1424 05NOV20. REMOVED AND REPLACED ANNUNCIATOR LIGHT MODULE, PER AMM 33-16-02. CHECKS OK. THIS CLEARS MDDR 1371SDR UIEA2020102802329Relay · malfunctionedRT CENTER FUEL PUMP EICAS AFTER PUSHBACK. TRANSFERRED TO MDDR 136873, IAW DDG 28-22-02A. CAT C DUE 07NOV20. VERIFIED RT BOOST PUMP INSTALLED IS 5006286F. PER FIM 28-22 FI 805 RT CENTER FUEL PUMP CB C370 IN CLOSED POSITION. VERIFIED RT GFI RELAY K10696 NOTSDR UIEA2020102702316Lock Bolt · out of positionLT ENGINE BLEED OFF EICAS MESSAGE. COMPLETED QRH CHECK LIST. ICING ENGINE EICAS MESSAGE, RAN QRH CHECK LIST. FOUND PRV LOCKOUT BOLT TO BE OUT OF POSITION. RE-INSTALLED AND TORQUED. RAN ENGINE AND PERFORMED OPERATIONS CHECK. OPERATIONS CHECK GOOD. BLEED SDR UIEA2020102402299Skin · crackedUPPER FUSELAGE AT APPROXIMATELY STA 654 TO STA 720 STR 10R TO 10L HAS EVIDENCE OF MULTIPLE SMOKED RIVETS. UPON REMOVAL OF 130 EA FASTENERS FOUND 2 EA. FASENTER HOLES CRACKED AT CROWN STA 654+22 STR 1L AND STR 1R. REAMED 2 EA CRACKED HOLES TO .214 WITH NDT VSDR UIEA2020102402300Oxygen Bottle · corrodedLAVATORY OXYGEN BOTTLE IS CORRODED. REMOVED AND REPLACED LAV OXYGEN BOTTLE, IAW B767 AMM 35-31-01-400-801-001.SDR UIEA2020102502303Igniter · malfunctionedSTATUS MESSAGE: LT ENGINE IGNITOR 1. NO LIGHT OFF OF FIRST ATTEMPT, LEFT ENGINE NORMAL START 2ND ATTEMPT W/ENGINE START BOTH. PERFORMED AUDIBLE TEST OF LT ENGINE IGNITER 1. NO FAULTS NOTED, STATUS MESSAGE CLEARED, NO FAULTS NOTED AT THIS TIME. PERFORMED AUSDR UIEA2020102402293Ecu · malfunctionedRT ENGINE CONTROL EICAS MESSAGE AFTER ENGINE START. REMOVED AND REPLACED ECU. OPERATIONS CHECKS NORMAL, IAW AMM 73-21-15. PERFORMED ENGINE RUN-UP, OPERATIONS CHECKS NORMAL. NO FAULTS NOTED, IAW AMM 71-00-00.SDR UIEA2020102202285Oxygen Mask · no testF/O MASK FAILED THE PREFLIGHT TEST. SWAPPED F/O'S CREW O2 MASK WITH RT SUPER NUMERARY OBSERVER POSITION. PLACED ON MEL 35-11-02-03A. TRANSFERED TO MDDR 136525. T.J. 12:25 22OCT20. R & R RT SUPERNUMERARY OXYGEN MASK, IAW AMM 35-11-51. OPERATIONS CHECK GOOSDR UIEA2020101502259Warning Message · false activationCENTER RT FUEL PUMP EICAS MESSAGE CENTER TANK FUEL PUMPS, ONE INOPERATIVE, CENTER TANK FUEL USED. NOTIFY DISPATCH. TRANSFERRED TO MDDR 136097, IAW MEL 28-22-02A, CAT C 10/17/2020. REVERSED DDG, PERFORM FIM 28-22 TASK 805, NO FAULTS NOTED AND SYSTEM TESTED GSDR UIEA2020101602263Packing · leakingDURING WALK AROUND FOUND NR 1 ENGINE FUEL LEAK. FOUND FUEL OIL COOLER LINE BROKEN. R & R LINE, IAW AMM 24-11-10. LEAK CHECK PENDING. PERFORMED ENGINE WET MOTOR AND ENGINE RUN UP, NO LEAKS NOTED. OPERATIONS CHECK NORMAL, IAW 71-00-00 REF LEAK CHECK ONLY. SDR P5CA2020101500360Pin · missingF/O OXYGEN MASK PIN IS MISSING. RE-SECURED F/O O2 MASK, IAW B767-300 AMM 35-11-51.SDR UIEA2020101302235Bleed Valve · unknownDUCT PRESSURE 2500 PSI WITH APU ON AND APU BLEED VALVE OPEN. PERFORMED OPERATIONS CHECK OF PNEUMATIC SYSTEM, IAW AMM 36-00-00. OPERATIONS CHECKS GOOD, SYSTEM IS OK.SDR UIEA2020101002208Gasket · leakingNR 2 ENGINE SHOWS SIGN OF OIL LEAK. REMOVED AND REPLACED FUEL TO/OIL HEAT EXCHANGE TUBE GASKET, IAW B767 AMM 79-21-01.SDR UIEA2020100752173O-Ring · damaged#2 ENGINE HAS OIL LEAK FROM HORIZONTAL DRIVE SHAFT. OIL LEAK IS WITH IN ALLOWABLE LIMITS. REF AMM TASK: 72-63-02-226-001-H00. ITEM TRANSFERRED TO NON-MEL NR 135433 FOR TRACKING PURPOSES AND PLANNED FURTHER ACTION. CVG STA, 13OCT20 LP 1250999, ITEM M8: SEE NRSDR UIEA2020100232136Valve · malfunctionedFWD EQUIP VALVE EICAS. TRANSFERRED TO DMI NR 135231, IAW MEL 21-58-07-02-01 CAT "C" DUE DATE 10OCT20. PLACARD INSTALLED. DEACTIVATED USING PROCEDURE NR 1. DISPATCH SP 00.13Z 30SEP20, CVG. VERIFIED VALVE TO BE FAULTING. REMOVED & REPLACED FWD EQUIPMENT VASDR UIEA2020093002142Lanyard · detachedPORTABLE ELT SAFETY CORD DAMAGED. RE-ATACHED LANYARD AS NECESSARY, IAW AMM 25-63-03.SDR P5CA2020093000324Warning Light · false indicationLEFT AFT FUEL PUMP ILLUMINATED ON EICAS THEN EXTINGUISHED WHILE IN CRUISE. PERFORMED OPERATIONAL CHECK OF THE LEFT AFT FUEL PUMP, IAW AMM 28-22-00. OPERATIONAL NORMAL, NO DEFECTS NOTED AT THIS TIME.SDR UIEA2020093002135Relay · failedRT ENG ANTI-ICE DISCRETE LIGHT DOES NOT ILLUMINATE "VALVE" WHILE IN TRANSIT. "TAI" DOES ILLUMINATE ON EICAS. TRANSFER TO MDDR 135223, CAT C, PER DDG 30-21-02-01A DUE 09OCT20. MX ACTION COMPLIED WITH, PLACARD INSTALLED. 2219Z SP. REMOVED AND REPLACED RELAYSDR UIEA2020100292131Warning Message · false activationFWD EQUIPMENT VALVE EICAS, QRH COMPLETED. RAN FIM 21-48 TASK, NO FAULTS NOTED AT THIS TIME.SDR UIEA2020100292132Duct · damagedAPU SURGE DUCT HAS HOLE IN IT. REMOVED AND REPLACED APU DUCT, IAW B767 AMM 20-11-01. PERFORMED OPERATIONS CHECK, IAW AMM 49-11-00. OPERATIONS CHECK GOOD.
Back to Boeing 767-306