Boeing 767-306
Service difficulty reports · 2,510
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2021072601629Clamp · unsecureL BLD DUCT LEAK EICAS PRIOR TO START UP(<P>FOUND 3 LEAKS. ADJUSTED CLAMPS AND RE-TIGHTENED. NO FAULTS FOUND AT THIS TIME. IAW B767 AMM 20-11-00. LEAK CHECK GOOD</P>)SDR UIEA2021072301619Radar · malfunctionedR RADAR DOES NOT PAINT GROUND OR WEATHER RETURNS(<P>PERFORMED WEATHER RADAR SYSTEM OPERATIONAL TEST IAW B767 AMM 34-43-00-715-001-001. OPS CHECK NORMAL AT THIS TIME. </P>)SDR UIEA2021072001598Bleed Valve · faultedNO APU DUCT PRESSURE(<P>TRANSFERRED TO DMI # 150428 IAW MEL 49-11-01-01 CAT C. MCC NOTIFIED. PLACARDS INTALLED. DP 1425Z.</P> / <P>22JUL21 - LP 1370369 - ITEM# 5 - CVG - REMOVED AND REPLACED APU BLEED VLV. IAW B767 AMM 36-11-10. OPS CHECK OK. THIS CLEARS MDDRSDR UIEA2021071901587Apu · unknownAPU INOP ( AUXILIARY POWER UNIT (APU), ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60 )(<P>TRANSFERRED TO MDDR 150385 IAW MEL 49-11-01A, CAT C.</P> / <P>LP 1486189: PERFORMED FIM. 49-11 FT 988. NO DEFECTS NOFECTS NOTED. APU OPS CHECK GOOD. THIS CLEARS DMI 150SDR UIEA2021071601562Pump · inoperativeRH CENTER FUEL PUMP INOP(<P>TRANSFERRED TO MDDR <SPAN>150252</SPAN><SPAN> IAW MEL 28-22-02A, CAT C.</SPAN></P> / <P>LOG PAGE 1453782 ITEM 4 - REMOVED AND REPLACED CENTER RT FUEL PUMP IAW 28-22-05. OPERATIONAL TEST GOOD NO FAULTS - AMM 28-22-05. THIS CLEARS MDDSDR UIEA2021071601576Control Panel · failedTCAS/ ATC CONTROL PANEL FAILED, RELEASED SMOKE FROM DISPLAY. REF L/P 1390638/ M8 SMOKE OR FUMES IN THE CABIN, INSP. REQUIRED.(<P>REMOVED AND REPLACED TCAS/ATC CONTROL PANEL. OPS CHECK PASS. NO FAULTS AT THIS TIME IAW B767-300 AMM 34-53-02.</P> / <P>LP 1390638/SDR UIEA2021071501549Pressure Switch · faultedR ENG TAI VALVE STATUS MESSAGE(<P>TRANSFERRED TO MDDR 150187 IAW MEL 30-21-01-04-02, CAT C.</P> / <P>LP 1453769: REMOVED AND REPLACED ENG. INLET TAI PRESSURE SWITCH IAW AMM 30-21-01. OPERATIONAL CHECK OK. NO EICAS MSG. A/C OK TO RELEASE. THIS CLEARS MDDR 15018SDR UIEA2021071501552Module · faultedR ENG BLEED VALVE WOULD NOT OPEN, EVEN AT 75% N2(<P>REMOVED AND REPLACED ENG PRESSURE REGULATING VALVE IAW AMM 36-11-18. S/N OFF - NSN P/N OFF-792755-15 - VALVE.</P> / <P>14JUL21 - 1390662 - ITEM# 5 - CVG - REMOVED AND REPLACED AIR SUPPLY BITE MODULE IAW AMM 3SDR P5CA2021071400264Warning Message · false activationON DEPT AND IN FLT R BLEED OFF EICAS MSG INTERMITTANT FOR PROLONGED PERIODS. COMPLETED W/ QRH. REPEAT WRITE UP. SEE LP 1461467(<P>REF MEL 21-51-01-01 OPERATION STEP 5, FAULT MSG NML. NO MX ACTION REQUIRED.</P>)SDR P5CA2021071200260Acm · faultedR/H PACK INOP MIX MANIFOLD FAULT(<P>DEFERRED R/H PACK IAW MEL 21-51-01-01. CAT C, DMI # 150027, MAINTENANCE FUNCTION C/W, DUE DATE 22 JUL 21. MCC NOTIFIED. PLACARDS INSTALLED.</P> / <P>LP 1362144: REMOVED AND REPLACED ACM PER B767 AMM 21-51-03-004-001 21-51-03SDR UIEA2021071401547Window · unknownON TAKEOFF CLIMB FIRST OFFICERS R2 WINDOW OPENED. RETURNED BACK TO RFD FOR A NORMAL LANDING(<P>CHECKED R2 WINDOW, RIGGING, TRACK AND LATCH WORKING PROPERLY. VISUALLY INSP INSIDE AND OUTSIDE NO ABNORMAL SIGN IAW AMM 56-11-02. WINDOW CLOSED AND LATCHED</P>)SDR UIEA2021071201532Oxygen Bottle · leakingPAX O2 REGULATOR LEAKING(<P><SPAN>REMOVED O2 BOTTLE AND INSTALLED OVERHAULED UNIT IAW AMM 35-11-03. LEAK CHECK PER AMM 35-11-00</SPAN></P>)SDR UIEA2021071001508Indication Sys · false indicationINDICATION ON RIGHT ENG FAN VIBRATION FLUCTUATING BETWEEN 1.0 < 3.5 ON CLIMB OUT FOR A FEW MINS. NO ABNORMAL VIBRATION NOTED/ FELT.(<P>TRANSFERRED TO MDDR 149953 PER MEL 77-31-01-01, CAT "C", DUE DATE: 20JUL21. DISP: LC @ 17:25Z.</P> / <P>CVG MX, 13JUL, LP 145SDR UIEA2021071201538Warning Message · false activationEICAS MESSAGE L ENG PRV CLEARED AT 1500FT, STATUS MSG L ENG PRV(<P>T/S PER FIM 36-10 FT 847. NO FAULTS NOTED.</P>)SDR UIEA2021071501551Warning Message · false activationWXR SYS STATUS MESSAGE IN FLIGHT(<P>PERFORMED WEATHER RADAR OPERATIONAL CHECK PER AMM 34-43-00. NO FAULTS NOTED.</P>)SDR UIEA2021070801487Valve · inoperativeAPU BLEED NOT SUPPLYING DUCT PRESSURE AND BLEED VALVE NOT INDICATING OPEN.FOUND GROUNDED SHIELD AT ECU, REPAIRED WIRING. REMOVED AND REPLACED APU BLEED AIR VALVE IAW AMM 36-11-00. OPS CK GOOD.SDR UIEA2021070801494Display · failedCAPTAINS ADI DISPLAY FLICKERED ON OFF. SMELL OF ELECTRIC BURNING. ALSO HEARD RELAY CLICKING NOISE. TURNED BRIGHTNESS DOWN, NO FURTHER PROBLEMS. PERFORMED SMOKE OR FUMES IN CABIN INSP. IAW AMM 05-51-56. NO SIGNS OF SMOKE OR OIL CONTAMINATION NOTED OPS NORMAL. SDR UIEA2021070801486Warning Message · false activationAPU BLEED VALVE EICAS ON BLOCK IN.(<P>CYCLED APU BLEED VALVE PER AMM 36-11-10. OPS CHECK GOOD AT THIS TIME.</P>)SDR P5CA2021070700256Warning Light · false activationFWD CGO BACKUP EICAS MSG ON AIPT, RAN QRH MEASSAGE AND NO ASSOCIATED "FAULT" LIGHT ON OVERHEAD PANEL CLEARED ON ITS OWN.(<P>NO FAULT PRESENT AT THIS TIME FIM 21-61 TREE 922. NO FURTHER ISSUE. OPS CKS OK ON GROUND.</P>)SDR UIEA2021070601473Valve · failedAPU PNEUMATICS INOP(<P>TRANSFERRED TO MDDR 149618 IAW MEL 49-11-01-01, CAT C.</P> / <P>LP 1361901 - ON A/C ARRIVAL WE ACTIVATED PNEUMATICS ON APU, WE HAD 30 PSI OF DUCT PRESSURE WITH PACKS OFF, WITH BOTH PACKS RUNNING WE HAVE 20-25 PSI OF DUCT PRESSURE, RAN ASDR UIEA2021070801489Circuit Breaker · trippedPRIOR TO TAKE OFF WXRDR F23 AND F21 CIRCUIT BRAKERS POPPED. THUNDERSTORMS IN VICINITY AT DEPARTURE AIRPORT.(<P>PERFORMED OPS CK WXR RADAR PER AMM 34-43-00. OPS CHECK GOOD @ THIS TIME. NO DEFECTS NOTED.</P>)SDR P5CA2021070600255Warning Message · false activationL FWD WINDOW EICAS MESSAGE, CYCLED SWITCH AND EICAS MESSAGE REMAINED.(<P>PERFORMED OPS CHECK FOR L FWD WINDOW HEAT EICAS MSG IAW AMM 30-41-00. OPS CHECK GOOD.</P>)SDR P5CA2021070200252Oil System · lowAPU FAULT UPON START ON TAXI IN. APU WOULD NOT START.(<P>OIL QTY LOW. SERVICED APU OIL TO FULL IAW AMM 12-13-04-613-06. APU OPS NORMAL.</P>)SDR P5CA2021070200253Warning Message · false activationFWD CGO BACKUP ADVISORY MESSAGE ON DEPARTURE. QRH COMPLETE. MESSAGE CLEARED ON IT'S OWN(<P>PERFORMED FIM 21-61 TREE 922 AND OPS CHECK IAW AMM 21-22-00. NO FAULTS RECORDED AT THIS TIME. </P>)SDR UIEA2021070101458Module · faultedAPU BLEED INOP ( AUXILIARY POWER UNIT, PNEUMATIC FUNCTION )(<P>TRANSFERRED TO MDDR 149488, DUE 10JUL21, CAT C, IAW ATLAS DDG 49-11-01-01. MX ACTION COMPLIED WITH.</P> / <P><SPAN>LP 1363567: REPLACED FLOW SENSING MODULE. PERFORMED ENGINE RUN. OPS CHECK GOOD IAWSDR UIEA2021070101448Status Message · false activationITEM #1 STATUS MESSAGE WXR SYS DISPLAYED IN FLIGHT.(<P>PERF FIM 34-43 FT 805, NO FAULTS NOTED. PERF OPS TEST IAW AMM 34-43-00, OPS TEST GOOD, NO DEFECTS OR STATUS MSGS NOTED AT THIS TIME.</P>)SDR UIEA2021070101460Warning Message · false indicationSTATUS MESSAGE WXR SYS DISPLAYED IN FLIGHT.(<P>PERF FIM 34-43 FT 805, NO FAULTS NOTED. FERF OPS TEST IAW AMM 34-43-00. OPS TEST GOOD. NO FEFECTS OR STATUS MSGS NOTED AT THIS TIME</P>)SDR UIEA2021062901438Start Valve · failedLEFT ENG START VALVE FAILED TO OPEN.(<P>.ITEM TRANSFERRED TO MDDR 149390 PER MEL 80-00-02-01 CAT C DUE DATE 09JUL21. DC @ 07:09Z.</P> / <P>01JUL21 - 1480181 - ITEM# 3 - ONT - R/R # 1 ENG START VALVE IAW AMM 80-11-00. OPS CHECK GOOF, LEAK CHECK GOOD. THIS CLEARSDR UIEA2021062801426Warning Message · false activation"FWD EQUIP VAL" ILLUMINATED DURING APPROACH, EXTINGUISHED AFTER TOUCH DOWN.(<P>PERF OPS CHECK FWD EQP COOLING PER AMM 21-58-00. ALL MODES OPERATE NORMAL, NO FAULTS NOTED.</P>)SDR UIEA2021062301407A/C Pack · malfunctionedUNABLE TO CONTROL FLT DK TEMP IN AUTO OR MANUAL TEMP CONTROL GAGE SAID FULL COLD BUT TEMP RISING. SAME CONDITION IN STBY MODE. ABLE TO CONTROL TEMP BY SHUTTING OFF (C) PACK(<P>REPACKED AND PERF BITE OF TEMP CONTROLLER IAW AMM 21-51-00. NO FAULTS NOTED. TESTED SDR UIEA2021062101390Computer · malfunctionedAUTOPILOT (C) FAILED AT FL380. UNABLE TO RE-ENGAGE THE C OR R AUTOPILOT FROM FL 370 AND THE HALFWAY POINT OF THE FLIGHT UNTIL LANDING. HAND FLEW THE REMAINDER OF THE FLIGHT AT 280. RVSM RESTRICTED(<P><SPAN>PERFORMED TEST 40 AND FOUND NO INFO CENTER C-CH DETENTSDR UIEA2021062201402Start Valve · faultedEICAS MESSAGE L START VALVE CUTOUT(<P>REMOVED AND REPLACED ENGINE #1 START VALVE IAW B767 AMM 80-11-02. OPS CHECK NORMAL AT THIS TIME. NO MESSAGES PRESENT AT THIS TIME. </P>)SDR UIEA2021062101398Warning Message · false activationR PACK TEMP ADVISORY MESSAGE IN DESCENT PROX 10000 FT. CAME ON TWICE- EXTINGUISHING BOTH TIMES(<P>PACK RESET & BIT CHECK IAW FIM TASK 21-51- TF 844, OPS CHECK GOOD & BITE CHECK GOOD, NO ACTIVE MESSAGES</P>)SDR UIEA2021062101389Relay · faultedENG #1 START SELECTOR WILL NOT STAY IN GND DURING ENGINE START.(<P>TRANSFERRED TO FLIGHT CREW DEFERRAL MEL #148761, DDG 80-11-02, CAT "C", 27JUN21 TJ M1755Z.</P> / <P>ONT - 23JUN21- LP 1478315 ITEM 10 - REF LP 1478314 ITEM M9, RELAY (K1173) REMOVED AND REPLACESDR UIEA2021062101391Relay · faultedENG #1 START VALVE INOP(<P>TRANSFERRED TO FLIGHT CREW DEFERRAL MEL # 148762, DDG 80-00-02-01 CAT "C", 27JUN21 TJ 1801Z. REMOVED AND REPLACED ENG START RELAY K1173 PER WDM 80-11-11. PERF ENG RUN PER AMM 71-00-00 FOR L ENG. START STAYS ON GND AND 50% CLICKS BASDR UIEA2021061601355Battery · faultedEMERGENCY LIGHTS ILLUMINATE AND CYCLE IN FLIGHT(<P>REMOVED AND REPLACED EMERGENCY LIGHT BATTERY AND CHARGER IAW B767 AMM 33-51-07. OPS CHECK GOOD AT THIS TIME.</P>)SDR UIEA2021061601363Warning Message · false activationSTATUS MSG R ENG SPEED CARD(<P>PERF FIM 73-21 FT 871. CLEARED MSG. TEST CHANNEL 1 AND 2. MSG DISPLAYS. SYSTEM TEST OK</P>)SDR UIEA2021061501354Igniter · faultedRT ENG IGNITOR 2 EICAS MSG ( IGNITION SYSTEMS, ER OPERATIONS ALLOWED )(<P><SPAN>TRANSFERRED TO MEL 74-00-01A, MDDR 148600.</SPAN></P> / <P>ONT-15 JUN - LP 1386635 - ITEM 6 - REMOVED AND REPLACED RIGHT HAND ENGINE IGNITOR PLUG IAW AMM 74-21-02. OPS CHECKS GOOD.SDR UIEA2021061401351Bulb · inoperativeEXIT OVERHEAD & ENTRY LIGHTS BLINK INTERMITTENTLY AT LOWER ALTITUDES.(<P>ON CHECK FOUND EMERGENCY CEILING LIGHT BULB INOP. REMOVED AND REPLACED CELING EMERGENCY LIGHT BULB PER B767-300 AMM 33-51-11. OPS CHECK EMERGENCY LIGHTS PER B767-300 TASK 33-51-00-715-227SDR UIEA2021061301341Oxygen Mask · no testCAPTAIN 02 MASK HARNESS DOES NOT INFLATE DURING TEST(<P>REMOVED AND REPLACED CAPTAIN 02 MASK IAW AMM 35-11-51. OPS CHECK GOOD.</P>)SDR UIEA2021061301340Warning Message · false activationIN DESCENT THROUGH FL350 STATUS MSG: R ENG SPEED CARD. PERFORMED T/S IAW FIM 73-21 FAULT TREE 871 AND FIM 31-41-00/101. NO FAULTS NOTED, SYSTEM IS OK.SDR UIEA2021061001313Warning Message · false activationLEFT PRV EICAS MSG.(<P>PERFORMED BITE TEST. TESTED NORMAL REF AMM 36-23-00. </P>)SDR UIEA2021061401348Warning Message · false activationSTATUS MSG AFT EQ EXH FAN 2(<P>PERFORMED OPS CHECK IAW AMM 21-58-00, OPS CHECK GOOD. FIM TASK 21-58 TASK 805 STATES SHORT TEMPORARY INTERRUPTIONS LIKE THE ONE THAT OCCUR DURING A POWER TRANSFER (GROUND-APU-ENGINE APU-GROUND) CAN CAUSE THE EICAS MESSAGE.</P>)SDR UIEA2021060901302Warning Message · false indicationEICAS MSG "FWD EQPT VAL" PRIOR TO BLOCK OUT(<P>EQUIP COOL AUTO MODE DEFERRED IAW MEL 21-51-01-01, MDDR # 148275, CAT C, EXP 19 JUN 21.</P><P>LOG PAGE 1453746: PERFORMED SYSTEM OPERATIONAL CHECK IAW 21-58-00, NO DEFECTS NOTED. THIS CLEARS MDDR 148275.<BR /></P>SDR UIEA2021060901303Connector · damagedAPU AUTO SHUTDOWN APPROX 30 MIN AFTER START, APU FAULT MESSAGE. TROUBLESHOT PER B767 FIM 49-11 TREE 909 GEN FILTER MSG ON ECU - APU INOP - ITEM PLACED ON DMI 148253 IAW MEL 49-11-01A, CAT C, DUE 19 JUN21. C/W AP-20109, PERFORMED AMM 49-20-00 GVI TASK NO FAULSDR UIEA2021060601275Pin · recessedAPU AUTO SHUT DOWN.(<P>PERFORMED APU CONTROL UNIT BITE TEST., FAULT CODE GEN FILTER ON BITE, REQUIRES FURTHER T/S. LOG 1485729 ITEM #9: FOUND CONNECTOR P20 PIN 2 RECESSED, PERFORMED FIM 49-11 F/T 998 FOR APU AUTO SHUT DOWN, FOUND RECESSED PIN ON CONNECTOR P20 SDR UIEA2021060701281Sensor · faultedAPU INOP(<P>TRANSFERRED TO MDDR # 148142 IAW MEL 49-11-01A CAT C DUE 16 JUN 21</P><P>CVG- 07 JUN- LP 1122138- ITEM 4- FOUND MINI FLAG 14, PT SENSOR ON BITE, CLEARED ECU, PERF OPS CHECK IAW AMM 49-11-00, OPS CK GOOD, NO FURTHER DEFECTS NOTED, CLEARED DMI 148142SDR UIEA2021060701284Circuit Card · faultedL ENG ANALOG N2 STATUS MESSAGE 2+10 IN FLIGHT(<P>PERFORMED FIM 73-21 FT901 RESISTANCE CHECK GOOD B/W PINS 3&4 ON N2 SPEED SENSOR.PERFORMED ENG RUN IAW AMM 71-00-00 MSG REMAINED.REMOVED AND REPLACED L ENG N2 SPEED CARD IAW WDM 77-12-12.AFTER MULTIPLE ENG RUNS SSDR UIEA2021060701283Circuit Card · faultedR ENG ANALOG N2 STATUS MESSAGE 0+30 IN FLIGHT(<P>PREFORMED FIM 73-21 FT 901 RESISTANCE BETWEEN PIN 3 AND 4 ON N2 SPEED SENSOR RESISTANCE CHECK GOOD, PERFORMED ENGINE RUN IAW AMM 71-00-00 STATUS MESSAGE REMAINED. REMOVED AD REPLACED RIGHT ENGINE N2 ENGINE SPEEDSDR P5CA2021053100206Smoke Detector · malfunctionedFWD CARGO DET 2 STATUS MSG APU POWER. NO MSG PRESENT ON EXT POWER(<P>DEFERRED TO MDDR# 147806.</P><P>31MAY21 - LOG# 783943 - ITEM 5 - CVG - REMOVED AND REPLACED CARGO SMOKE DETECTOR M325 IAW AMM 26-16-01. OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. THIS CLE
Back to Boeing 767-306