Boeing 767-322

Service difficulty reports · 11,764

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '767322'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UALA2012030801520Iru · faultyLEFT IRS FAULT ON ALIGNMENT. REPLACED LEFT IRU PER MM, ACCOMPLISHED TEST 30 PER MM. OPS CHECK GOOD.Mar 7, 2012 · N663UA · Boeing 767322 · Inertial Guidance SystemSDR UALA2012030701486Seal · leakingDURING WALKAROUND, FOUND HYD LEAKING DOWN BOTH SIDES OF TAIL COMPT. CYCLED RUDDER, FOUND UPPR RUDDER PCA LEAKING OUT OF FWD SHAFT SEAL. REMOVED UPPER RUDDER PCA. SHOP REPAIRED ACTUATOR BY REPLACING FWD SHAFT SEALS. WORKING INSTALL.Mar 6, 2012 · N657UA · Boeing 767322 · Rudder ActuatorSDR UALA2012030601427Cable · shortedP62 PIGTAIL SPARKS WHEN DISCONNECTED. COLLARED CB. REPLACED SHORTED PIGTAIL CABLE AND RESET C-B.Mar 6, 2012 · N652UA · Boeing 767322 · Equipment/Furnishings WiringSDR UALA2012030801518Probe · faultedRT ENGINE CONTROL EICAS MESSAGE. TROUBLESHOT PER FIM 73-21-00, FAULTED 2.9 BLEED VALVE THERMOCOUPLE PROBE. REPLACED PROBE PER MM.Mar 5, 2012 · N672UA · Boeing 767322 · Compressor Bleed ValveSDR UALA2012030501412Circuit Card · faultyL ENG HPSOV EICAS MSG DISPLAYED DURING TAXI OUT. WIRED REMOVED FROM CONNECTOR PER MEL. RETURN WIRE W3510-017-18 FROM TERMINAL 2 BACK TO TERMINAL 1 WHEN CLEARING DEFERRED ITEM REF MEL CARD 36060 MAINT STEP B. REPLACED LT ENG BLD CARD, SEE PTT REF 0112012.Mar 4, 2012 · N673UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2012030501409Control Unit · faultyAPU FAULT LIGHT ON START UPON LANDING. REPLACED APU CONTROL UNIT, STARTS & RUNS NORMAL.Mar 4, 2012 · N643UA · Boeing 767322 · APU ControlsSDR UALA2012030501393Light · missingPER INBD FLIGHT CREW AFT EEL LIGHT MISSING FROM 6H. REPLACED LIGHT ASSEMBLY, OPS CHECKS GOOD.Mar 4, 2012 · N669UA · Boeing 767322 · Emergency LightingSDR UALA2012030501395Computer · faultyRIGHT FD FAILED AND NO LAND 3 ASA. RIGHT FCC IAW MM & GROUND TEST PASSED. AC FULL CAT III STATUS.Mar 4, 2012 · N662UA · Boeing 767322 · Autopilot ComputerSDR UALA2012030501327Unknown · malfunctionedAFTER REFUEL OPERATION WAS FINISHED FUEL INDICATED 67,500. LESS THAN 15 MINUTES LATER FUEL INDICATED 65,200. FUELER CYCLED FUEL DOOR AND INDICATION RETURNED TO 67,400. NEED MAINTENANCE TO ACP BITE CHECK OF FUEL QTY PROCESSOR AND CONFIRM FUEL LOAD WITH DRIP SMar 3, 2012 · N669UA · Boeing 767322 · Fuel Quantity IndicatorSDR UALA2012030501344Fan · faultyEICAS MSG: 'L RECIR FAN' DISPLAYED & 'L RECIRC FAN INOP' LIGHT ILLUM, WITH SWITCH 'ON'. SLIGHT ELECT ODOR IN CABIN. SAMC TEXT: CREW WENT TO MAIN CABIN TO INVESTIGATE. UPON RETURN TO FLT DECK THE LEFT RECIRC FAN HAD QUIT WORKING. ODOR CLEARED AFTER FAN WAS Mar 3, 2012 · N662UA · Boeing 767322 · Air Distribution FanSDR UALA2012030201294Engine · surgesNR 1 ENGINE SURGED DURING HIGH POWER RUN. NOTE BLEED SHIFTED AT 79% N2, DUCT PRESSURE 35 PSI QUICKLY DROP TO 26 AND RETURNED BACK TO 36 AT N2 92.7% AT HIGH POWER. THEN ABOUT 20 SECONDS ENG SURGED. WINDS SPEED WAS 0. ACCOMPLISHED ENGINE SURGE INSPECTION ANDMar 2, 2012 · N673UA · Boeing 767322 · Engine (Turbine/Turboprop)SDR UALA2012030201313O-Ring · leakingAFTER 5 MIN IDLE FOUND LEAKAGE AROUND THE OIL TANK CAP AREA. REPLACED OIL TANK CAP O-RING PER A-CK J-C.Mar 2, 2012 · N655UA · Boeing 767322 · Engine Oil Storage (Airframe Furnished)SDR UALA2012030201307Fireseal · missingPANEL 437AR AFT FIRE SEAL MISSING. REPAIRED FIRE SEAL SECTION.Mar 2, 2012 · N655UA · Boeing 767322 · Nacelle/Pylon Miscellaneous StructureSDR UALA2012030201298Oil Filter · faultyON RIGHT ENG START R OIL FILTER EICAS FOR 2 SEC NOW R OIL FILTER STATUS MESSAGE. ACCOMPLISH AMM. REPLACED ENGINE 2 MAIN OIL FILTER.Mar 2, 2012 · N660UA · Boeing 767322 · Turbine Engine Oil SystemSDR UALA2012030101289Wire · pulledLEFT SIDE WINDOW HEAT INOP. FOUND GND WIRE AT LEFT WINDOW 2 CONNECTOR D5872P POS 2 WIRE W624-101O-20 HAD PULLED OUT OF SOCKET, RETERMINATED AND SECURED WIRE. WINDOW HEAT TEST OKAY.Mar 1, 2012 · N648UA · Boeing 767322 · Windshield/Door Rain/Ice RemovalSDR UALA2012030201318Mirror · odorHEAVY SMELL AT 2L LAV LIKE MELTING PLASTIC. INSPECTED LAV NO ELECTRICAL SMELL NOTED, LAV MIRROR JUST REPLACED SUSPECT ODOR FROM NEW MIRROR.Mar 1, 2012 · N664UA · Boeing 767322 · LavatoriesSDR UALA2012030201317Display · faultyUPPER EICAS SCREEN SHOWING INCORRECT COLORS AND STATUS WON'T DIM AFTER SHUTDOWN. REPLACED UPPER EICAS DISPLAY PER AMM. OP CHECK OKAY.Mar 1, 2012 · N651UA · Boeing 767322 · Central DisplaySDR UALA2012030101270Antenna · faultySTATIC NR 1 VHF COMM RADIO MAKING COMM IMPOSSIBLE. FLYING IN PRECIP NR 2 VHF COMM CLEAR. PER LOCAL MANAGEMENT'S DIRECTIVE, REPLACED L VHF ANTENNA PER MM, USING THE ALTERNATE METHOD (NO GEL GASKET USED).Feb 29, 2012 · N677UA · Boeing 767322 · VHF Communications SystemSDR UALA2012022901260Igniter · failedCREW REPORT: NR 1 ENGINE NO LIGHT OFF. START OK SECOND ATTEMPT WITH START SWITCH IN BOTH. MEL COMPLIED WITH BY FLIGHT CREW. REPLACED NR 1 IGNITER PLUG. RAN MOTOR OPS NORMAL.Feb 29, 2012 · N666UA · Boeing 767322 · Spark Plug/IgniterSDR UALA2012030101288Battery · faultyMAIN BATTERY CHARGER STATUS MSG. REPLACED MAIN BATTERY AND BATTERY CHARGER PER MM, OPS CKS GOOD. CLEARED MESSAGE. BATTERY READING 29 VOLTS.Feb 29, 2012 · N646UA · Boeing 767322 · Battery/Charger SystemSDR UALA2012030101271Controller · faultyREF CH2410 PERFORM PNEUMATIC SYSTEM HEALTH CHK. COMPLETED CHECK OF THE PRSOV. PRSOV TESTED OK. ACCOMPLISHED PNEUMATIC HEALTH CK FROM STEP 34 TO END. FOUND PRC OUT OF LIMITS AND SENSE LINE FROM PRECOOLER TO PRC LEAKING. HPPRV CK'D OK.Feb 29, 2012 · N673UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2012022901267Shutoff Valve · faultyCREW REPORT: L ENG HPSOV EICAS. NO L ENG BLEED LIGHT. L ENG BLEED CLOSED PER PROCEDURE. COMPLIED WITH MEL CARD. ACCOMPLISHED BITE FAULT LH HPSOV REPLACED NR 1 ENG HPSOV IAW AMM, TESTS OKAY.Feb 29, 2012 · N677UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2012022801211Pipe · leakingFUEL LEAK FROM NR 2 ENGINE. REPLACED PIPE PER MM. ACCOMPLISHED NONE RII INSPECTION PER MM. ALL CHECKS NORMAL.Feb 28, 2012 · N660UA · Boeing 767322 · Engine Fuel DistributionSDR UALA2012022901251Rotary Actuator · faultyRAMP REPORTED THAT FWD CARGO DOOR MAKING NOISE WHEN CLOSING. RAN FWD CARGO DOOR THRU RECYCLE AND FOUND FWD CARGO DOOR MAKING NOISE IN BOTH DIRECTION. NOISE SEEMS TO BE COMING FROM LIFT ACTUATOR OR DOOR LINKS BEARING CYCLE DOOR CLOSE AND CONFIRMED DOOR CLOSEFeb 28, 2012 · N665UA · Boeing 767322 · Cargo/Baggage DoorsSDR UALA2012022801207Shutoff Valve · faulty20 PSI DUCT SPLIT ON CLIMBOUT. LEFT DUCT 60 PSI, RT DUCT 40 PSI. NO SPLIT AT CRUISE POWER. REPLACED NR 1 ENG PRSOV. OPS GOOD.Feb 28, 2012 · N661UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2012022901268Controller · faultyAPU DID NOT START ON TAXI IN TWO ATTEMPTS. COMPLIED WITH MEL. RPL'D APUC.Feb 28, 2012 · N644UA · Boeing 767322 · APU ControlsSDR UALA2012022801241Light · damagedEEL LIGHT ON SIDE OF SEATS 2B AND 6B ARE DAMAGED. NEEDS NEW LIGHT ASSY. REPLACED 2B, AND 6B EEL LIGHTS AFT POSITION. P/N 7894-1. OPS TEST NORMAL.Feb 28, 2012 · N672UA · Boeing 767322 · Emergency LightingSDR UALA2012022801237Light · inoperativeSEAT MOUNTED EEL LIGHT INOP 3B. ACCOMPLISH NON-RII INSPECTION OF AMIS ITEM 0922011. RPL'D EEL LIGHT AT 3B. OPS CHECK GOOD. ACCOMPLISHED IDT INSPECTION OF EEL LIGHT STRIP INSTALLED AT SEAT 3B.Feb 28, 2012 · N665UA · Boeing 767322 · Emergency LightingSDR UALA2012022801235Shutoff Valve · faultyL ENG BLEED FAILURE, FLIGHT DIVERTED. FOUND PRSOV BAD AND CHECK NEW PRSOV GOOD. OPS CHECKED ENG GOOD.Feb 28, 2012 · N673UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2012022901259Pcu · leakingEVIDENCE OF SKYDROL AS VIEWED FROM GROUND COMING DOWN BOTH SIDES OF TAIL CONE ABOVE APU CONTINUING DOWN FUSELAGE TO BELLY DRIPPING ON GROUND. FOUND UPPER RUD PCU (CTR SYS) LEAKING FROM FWD ROD END, RPLCD UPR RUD PCU WITH BORROWED PCU FROM AA, SNAA10, PN 28290Feb 27, 2012 · N668UA · Boeing 767322 · Rudder Control SystemSDR UALA2012022801203Fitting · leakingFUEL LEAKING FROM LOWER RIGHT AFT SPAR TO FUSELAGE ATTACH FITTING (CENTER TANK). RESEALED FITTING RESEALED LEAKS IN CTR TANK, (SEE SEQ 8012030, 8012031, 8012032, 8012034-6).Feb 27, 2012 · N658UA · Boeing 767322 · Fuel StorageSDR UALA2012022801202Structure · leakingFUEL LEAKING FROM CENTER TANK SEAM ABOVE THE LEFT AC PACK REHEATER (AREA WASHED AWAY). RESEALED SEAM.Feb 27, 2012 · N658UA · Boeing 767322 · Fuel StorageSDR UALA2012022801201Structure · leakingFUEL LEAKING FROM LEFT LOWER AFT SPAR TO FUSELAGE ATTACH FITTING (CENTER TANK). RESEALED FITTING & RESEALED SEAM IN CTR TANK.Feb 27, 2012 · N658UA · Boeing 767322 · Fuel StorageSDR UALA2012022701178Hsi · malfunctionedCAPTAIN'S EHSI WENT INOP, FLIGHT DIVERTED. CREW REPORTS CAPT EHSI IS BLANK, SWITCHING INST SOURCE SELECT SW TO ALT HAS NO EFFECT. REPLACED EHSI, ALL OPS CHECKS SATISFACTORY.Feb 27, 2012 · N654UA · Boeing 767322 · Integrated Flight SystemSDR UALA2012022701186Chiller · faultyLEFT AFT CHILLER BLOWING WARM AIR. REPLACED CHILLER PER AMM, OPS CHECK NORMAL. UNIT OFF MR25349-1500 UNIT ON MR25349-1472.Feb 27, 2012 · N666UA · Boeing 767322 · Buffet/GalleysSDR UALA2012022901269Actuator · faultyRUDDER RATIO OVERHEAD LIGHT ON AND WITH RUDDER RATIO EICAS MESSAGE. CAN BE CLEARED BY CYCLING RUDDER RATIO CB CONDITION CAN BE DUPLICATED WITH BOTH ENGS RUNNING WITH NR 1 EDP SELECTED OFF THEN BACK ON. BOTH LEFT AND RIGHT RRMC SHOW PCA YELLOW FAULT BALLS. RFeb 27, 2012 · N673UA · Boeing 767322 · Rudder ActuatorSDR UALA2012022801217Pressure Switch · faultyFOUND LEFT HYDRAULIC SYSTEM PRESSURE LIGHT AND ASSOCIATED EICAS "L HYD SYS PR" MESSAGE INOP. FOUND ELEC HYD PUMP L CTL S27 PRESSURE SWITCH OPEN. VERIFIED THIS IS ALSO THE PROBLEM WITH RUDDER RATIO. SWITCH NIS DEN PCN (481-0076). REPLACED S27 REF IPC 29-11-Feb 27, 2012 · N673UA · Boeing 767322 · Hydraulic Pressure Relief Valve, MainSDR UALA2012022801204Control Panel · faultyLT OBSERVERS RADIO CONTROL PANEL LIGHT PLATE INOP AND NONE OF THE RADIO SELECT BUTTONS ARE LIT. REPLACED CONTROL PANEL. LIGHTS AND OP CHECKED NORMAL.Feb 26, 2012 · N658UA · Boeing 767322 · Communications SystemSDR UALA2012022801200Structure · leakingFUEL LEAKING FROM CENTER TANK SEAM JUST AFT OF THE RIGHT INBD TANK SUMP (PREVIOUSLY REPAIRED). CLEANED AND RESEALED AREA INSIDE TANK. SEALANT APPLIED 0200 OF FEB 26. OUTSIDE FITTING AND SEAM NEEDS TO BE RESEALED. RESEALED SEAM.Feb 26, 2012 · N658UA · Boeing 767322 · Wing Miscellaneous StructureSDR UALA2012022801199Structure · leakingFUEL LEAKING FROM LEFT LOWER WING ATTACH FITTING SEAM NEAR THE LEFT INBD CENTER TANK SUMP (SEALANT REMOVED). CLEANED AND RESEALED AREA INSIDE TANK. APPLIED SEALANT AT 0200 OF 26 FEB. OUTSIDE FITTING AND SEAM NEEDS TO BE RESEALED. RESEALED SEAM.Feb 26, 2012 · N658UA · Boeing 767322 · Wing Miscellaneous StructureSDR UALA2012022701193Eec · malfunctionedENG EXPERIENCED A 'SILENT SURGE'. PLEASE REPLACE THE EEC MR73412 PCN 480-9191. REF MM 73-21-04 P4XX. PUT EG ALERT TAG ON REMOVED EEC. WRITE RMVL REASON AS "ROUTE TO HS FOR PB SENSORS RPLMNT. REF HS SB EEC131-73-62 DUE SURGE". REPLACED LT ENG EEC PER MM, Feb 26, 2012 · N643UA · Boeing 767322 · Fuel Control/Turbine EnginesSDR UALA2012022701162Receiver · faultyUNABLE RNP EICAS MSG. SWAPPED LEFT AND CENTER MULTI MODE RECEIVER AND REALIGNED IRUS NO MSG PRESENT. LEFT MMR IS MR34301-49 CENTER MMR IS MR34301-57. ACFT REMOVED FROM CAT III STATUS.Feb 26, 2012 · N664UA · Boeing 767322 · Landing and Taxi AidsSDR UALA2012022901266Controller · faultyON DESCENT L ENG HPSOV CAUTION CAME ON, WENT OUT AT 15-16 THOUSAND. LOCKED L ENG HPSOV IN CLOSED POSITION PER MEL. ACP'D AIR SUPPLY CONTROL SYSTEM BITE TEST PER MM, HAD "HPC" AND "HPSOV" FAULT. ACP'D PNEUMATIC HEALTH CK ON HPSOV-HPC AND PRV-PRC PER MM. HPCFeb 26, 2012 · N677UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2012022901242Shutoff Valve · faultyAT FL 360 AND BLOW WITH THROTTLES SET APPROX 50 PCT THE LEFT DUCT PRESS FLUXES FROM 20-40 PSI. RPLC'D HIGH STAGE VALVE & HIGH STAGE CONTROLLER.Feb 26, 2012 · N673UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2012022801210Transceiver · faultyTOO MUCH NOISE ON RADAR WITH GAIN MORE THAN 50 PERCENT. REPLACED WXR TRANSCEIVER PER MM. GROUND CHECK NORMAL.Feb 26, 2012 · N660UA · Boeing 767322 · Weather Radar SystemSDR UALA2012022801206Unknown · malfunctionedRIGHT TO LEFT TANK TRANSFER ACCOMPLISH LEFT TANK TO CENTER TRANSFER PER MM. ACCOMPLISHED CHECK PER MM AND NO FUEL TRANSFER FROM LEFT TANK.Feb 26, 2012 · N661UA · Boeing 767322 · Fuel Transfer ValveSDR UALA2012022701158Tape · burnedPLUMBING INSTALLATION SECT 43 DRAIN HOSE FOR B119 HEATER TAPE BURNED. REPLACED HEATER TAPE, OPS CHECK GOOD.Feb 25, 2012 · N641UA · Boeing 767322 · Water Line Anti-Ice SystemSDR UALA2012022701160Strap · damagedRT FAILSAFE STRAP AT STA 955 FAILED ULTRA-SOUND TEST. ACCOMPLISHED COA 618451 RT STA 955 FLSF STRP RWK (SB 767-53A100 REV 1).Feb 25, 2012 · N642UA · Boeing 767322 · Fuselage Main, FrameSDR UALA2012022701150Cable · smokeFOOD CART CONTROLLER CORD 'N51' STARTED SMOKING. CREW SELECTED SWITCH TO OFF, OPENED CB AND DISCONNECTED CART CORD. SMOKE DISSIPATED. RESET CB &CONNECTED CART RAN FOR 15 MINS, INSPECTED PIGTAIL AND CONNECTORS, NO SIGN OF DAMAGE OR SMOKE-SUSPECT POSS PROBLEMFeb 25, 2012 · N648UA · Boeing 767322 · Equipment/Furnishings WiringSDR UALA2012022701159Channel · corrodedFWD CARGO STA 560, RBL 18 CORROSION ON 'C' CHANNEL. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW 'C' CHANNEL BETWEEN STA 540 - 560, RBL 18.Feb 25, 2012 · N642UA · Boeing 767322 · Fuselage Miscellaneous Structure
Back to Boeing 767-322