Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011112106385Light · misinstalledAFT RT GALLEY EEL INSTALLED INCORRECTLY. REPLACED AND OPS CHECKED THE AFT RT GALLEY EEL PER DRAWING 15F7209 AND MM. OPS CHECKED GOOD.SDR UALA2011112106384Light · misinstalledG2 LAV EEL INSTALLED INCORRECTLY. REPLACED AND OPS CHECKED THE G2 LAV EEL PER DRAWING 15F7209 AND MM. OPS CHECKED GOOD.SDR UALA2011112106383Light · misinstalledAFT GALLEY EEL INSTALLED INCORRECTLY. REPLACED AND OPS CHECKED THE AFT GALLEY EEL PER DRAWING 15F7209 AND MM. OPS CHECKED GOOD.SDR UALA2011112106382Light · misinstalledEEL INSTALLED INPROPERLY AT GALLEY 1. REPLACED AND OPS CHECKED THE EEL IN THE AFT GALLEY PER DRAWING 15F7209 AND MM. OPS CHECKED GOOD.SDR UALA2011112106377Light · damagedEEL LIGHTS TORN OFF SEATS 2H AND 4H. REPLACED LIGHT ASSYS, OPS GOOD.SDR UALA2011112106376Light · brokenFWD EEL LIGHT BROKEN AT SEAT 4B. REPLACED FWD EEL LIGHT AT SEAT 4B, OPS CHECK GOOD.SDR UALA2011112106371Light · inoperativeEEL LIGHT AT SEATS 35AB. REPLACED EEL LIGHT STRIP, OP CHECKS OKAY.SDR UALA2011112106370Light · inoperativeAISLE EMERGENCY LIGHT AT APPROX SEATS 2AB INOPERATIVE. RELAMPED, OP CHECKS OKAY.SDR UALA2011112106369Light · inoperativeAISLE EMERGENCY LIGHT AT APPROX SEATS 15HJ INOPERATIVE. RELAMPED, OP CHECKS NORMAL.SDR UALA2011112106368Light · missingONE EA EEL LIGHT MISSING AT SEATS 5HJ. REPLACED LIGHT ASSY CHECKED, OKAY.SDR UALA2011112106364Light · inoperativeTWO EA AISLE LIGHTS INOP IN FWD GALLEY AREA. SHOULD READ 2 EA AISLE EMERGENCY LIGHTS INOPERATIVE. RELAMPED, OPS CHECK OKAY.SDR UALA2011112106347Rod · wornNR 2 ENGINE PYLON STRUT PLENUM SUPPORT RODS ARE WORN OUT. REPLACED RODS.SDR UALA2011111806339Fitting · leakingNR 1 ENG HAS HEAVY COAKING AT 12'O'CLOCK. REMOVED 2 EA DRAIN LINES FROM PYLON AND HYD LINE CLUSTER NO BLOCKAGE NOTED. REMOVED PYLON ACCESS PNL 416BR & FOUND NO EVIDENCE OF LEAKAGE. REINSTALLED PNL. REMOVED NR 1 ENG PYLON JUNCTION BOX INSULATION AND COVER FSDR UALA2011112106405Pressure Switch · faultyLOW PRESS LT ON RT FWD FUEL PUMP NOT ON WITH SWITCH IN OFF POSITION. LT TESTS GOOD ON IND LT. REPLACED AFT RT FUEL PRESSURE SWITCH PER MM.SDR UALA2011112106346Duct · splitRIGHT WING OUTBD DUCT GOING TO ANTI-ICE VALVE ABOVE NR 2 PYLON IS SPLITTING OUTBD OF CLAMP (MKD WITH TAPE). REMOVED DUCT AND SENT TO WELDING SHOP. REPLACED DUCT.SDR UALA2011112106345B-Nut · leakingNR 2 PYLON, EVIDENCE OF HYDRAULIC LEAK, INBD SIDE. FOUND HYD PRESS LINE ABOVE NR 2 PYLON AT BULKHEAD FITTING LEAKING MARKED WITH TAPE. SECURED LOOSE 'B' NUT ON HYDRAULIC LINE. RAN HYDRAULICS AND MOTORED ENGINE, NO LEAKS FOUND.SDR UALA2011112106406Actuator · faultyAPU FAULT LIGHT ON W-APU RUNNING. REPLACED APU FUEL VLV ACTUATOR PER AMM. OPERATIONAL CHECK AND FAULT LIGHT INDICATIONS NOW NORMAL.SDR UALA2011111806335Wire · unsecureSEAT 5H HAS WIRES DANGLING FROM EMER EXIT LIGHTS. SECURED WIRE, LIGHT INOP. SECURED WIRING, OP CHECKS OKAY.SDR UALA2011112106341Eec · faultyWHILE ACCOMPLISHING PIMU BITE CHECK FOUND NR 2 ENG EEC CH A FAULT CAT 2 MESSAGE EEC CH A TCA SOL W-A FAIL. TROUBLESHOT REF FIM 71 PIMU MESSAGE INDEX PG64K,PG64L, MESSAGE 354-22 & REF WDM 71-51-14. COMPLETED TO ITEM G INDICATES NEED EEC. REF PTT # 6562008 FOSDR UALA2011111806322Light · looseEMERGENCY EXIT LIGHTS LOOSE BY SEAT 3B. SECURED LIGHT STRIP AT 3B.SDR UALA2011111706313Light · inoperativeLEFT OVERWING SLIDE EMERGENCY LIGHT AFT OF FLAPS (2ND TO LAST) INOPERATIVE. RELAMPED PER MM, OP CHECKS NORMAL.SDR UALA2011111706312Light · inoperativeEEL LIGHT AT SEATS 35KJ INOPERATIVE. RELAMPED, OP CHECKS NORMAL PER MM.SDR UALA2011111706319Light · inoperativeEMERGENCY EXIT LIGHTING INOP AT SEATS 1JH THRU 5JH. FOUND FLOOR STRIP L901 JUST AFT OF DOOR 1R DEFECTIVE. NEEDS NEW STRIP. NO PCN AVAIL. ONLY ONE FLOOR STRIP IS INOP. ALL REMAINING EMERGENCY LIGHTS OP NORMAL. ORDERED LIGHT ASSEMBLY 7976-3 LIGHT ASSY 38"SDR UALA2011111606282Shutoff Valve · faultyLEFT ENG PRV EICAS MSG ON DURING ENG START. MSG COMES ON AT 8-10% N2. CYCLED SWITCH, AND AIR SUPPLY CB S11 ON P11, RESTART ENGINE SAME FAULT. REPLACED NR 1 ENG PRV PER AMM DUE TO FOUND PRV FAIL IN MID POSITION - UNABLE TO MOVE MANUALLY WITH WRENCH. CHECKS SDR UALA2011111706295Truss · misrepairedTRUSS AT STA 343 -368 RBL 88.5 HAS IMPROPER EDGE DISTANCE. MAJOR REPAIR ACCOMPLISHED. REMOVED TRUSS AT STA 343- 368 RBL 88.5 IAW B767 SRM. FABRICATED NEW TRUSS IAW BOEING DRAWING 141T5331 FROM .90 7075-0. HEAT TREATED TO T6 IAW B767 SRM. TREATED, PRIMED ASDR UALA2011111706294Seat Track · wornSEAT TRACK LOCKING TABS WORN AT STA 1077 RBL 11. REMOVED SEAT TRACK DUE TO OUT OF LIMITS IAW B767 SRM. FROM STA 1060 TO 1117 RBL 11 FABRICATED NEW SEAT TRACK IAW BOEING DRAWING DWG 146T5210. ANODIZED, TREATED AND PRIMED NEW SEAT TRACK AND REPAIR PARTS IAW BSDR UALA2011111706293Seat Track · wornSEAT TRACK LOCKING TAB WORN AT STA 1109 AT LBL 11. REMOVED OUT OF LIMITS SEAT TRACK AT STA 1109 LBL 11 IAW B767 SRM. FABRICATED NEW SEAT TRACK ON TRAVLER 3364N00702. ANODIZED SEAT TRACK ON TRAVLER 3364N00837. INSTALLED SEAT TRACK IAW B767 SRM. PART MARKEDSDR UALA2011111706292Cable · chafedNR 1 PYLON ELECTRIC- HYDRAULIC PUMP GROUND CABLE GDO3512S IS CHAFED 75 PERCENT THROUGH FROM CONTACT WITH STRUCTURE. REPLACED HYD PUMP GROUND CABLE GDO3512S IAW B767 SWPM 20-60-02. OPS CHECKS GOOD IAW B767 AMM 29-11-00. ROUTED PROPERLY TO PREVENT FUTURE CHAFSDR UALA2011111706291Crease Beam · corrodedCORROSION ON CREASE BEAM INNER CHORD AT DOOR 1 RIGHT FROM STA 282 - 290 RBL 80. MAJOR REPAIR ACCOMPLISHED. RMV'D & RPL CREASE BEAM AND WEB AT DOOR 1R AT STA 246-STA 297 RBL 80 IAW B767 SRM. TREATED AND PRIMED IAW B767 MM. INSP Q845 PART MARKED CREASE BEAM SDR UALA2011111606271Door · out of rigRIGHT MAIN GEAR TRUNNION DOOR NEEDS TO BE RIG AND ROD ENDS SECURED AND SAFETIED. INSTALLED AND RIGGED RT MLG TRUNNION DOOR.SDR UALA2011111506253Floorbeam · corrodedAFT CARGO COMP BS 1197.88 FLOORBEAM IS CORRODED AT RBL 40. (N-R 3363N00414). MAJOR REPAIR ACCOMPLISHED. RMV'D CORROSION & FOUND BLEND OUT OF SRM LIMITS. RMV'D FLOORBEAM UPPER CHORD LBL40 TO RBL 40. FABRICATED & INSTALLED NEW FLOORBEAM UPPER CHORD.SDR UALA2011111506252Floorbeam · corrodedCORROSION UNDER FASTENER HOLES AFT CARGO FLOORBEAM AT STA 1197.132, LBL 6.5 - 10. MAJOR REPAIR ACCOMPLISHED. FOUND CORROSION TO BE OUT OF LIMITS AFTER BLENDING. REMOVED FLOORBEAM CHORD IAW B767 SRM. FABRICATED NEW FLOORBEAM CHORD FROM BAC 1506-3123 7075-T6SDR UALA2011111506251Frame · corrodedCORROSION ON FRAME CAP AT STA 325 - RBL 57. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME CAP AT STA 325 RBL 57 IAW B767-300 SRM.SDR UALA2011111606281Control Panel · faultyHEADING SELECT 1ST DIGITS SOMETIMES STICK (WILL NOT MOVE). REPLACED MODE CONTROL PANEL PER MM.SDR UALA2011111406224Line · crackedAPU OIL CONSUMPTION ABOVE LIMIT. WHILE PREPPING FOR APU CHANGE FOUND FLOW SENSING MODULE LOOSE AND MISSING. MOUNT HARDWARE FOUND IN CONTACT WITH SCAVANGE LINE BELOW SHOP. TESTED LINE. FOUND CRACKED AND LEAKING. REPLACED LINE AND INSTALLED MOUNT HARDWARE.SDR UALA2011111406221Wire Harness · damagedFWD EMERGENCY LIGHT STRIP ON SEAT 1H INOPERATIVE. LIGHT STRIP CONNECTOR DAMAGED. CAPPED AND STOWED WIRES AND SECURED. REPLACED LIGHT HARNESS ASSY LIGHT TEST GOOD.SDR UALA2011111506262Module · faultyFLAT-SLAT EICAS STATUS MSG. DUE TO UNABLE TO CLEAR 'SLAT ISLN VLV' MAINT MSG. REPLACED FLAP-SLAT SHUTOFF VALVE MODULE PER AMM. MSGS CLEARED AND ALL NORMAL.SDR UALA2011111506243Terminal Block · looseAT CABIN STA 654, RIGHT WING ILLUMINATION LIGHT HAS LOOSE TERMINAL BLOCK AND SHOWS SIGNS OF ARCING. RMV'D & RPLC'D RT WING ILLUMINATION LIGHT TERMINAL BLOCK IAW CMM EL-60-33-44-09 AND B767 AMM 33-41-00. OPS CHECKS GOOD IAW B767 AMM.SDR UALA2011111506244Floorbeam · corrodedSTA 325, RBL 45 FLOORBEAM CORRODED. MAJOR REPAIR ACCOMPLISHED DUE TO 100 PERCENT MATERIAL LOSS RMV'D AREA IAW B767 SRM. FABRICATED, TREATED, PRIMED AND INSTALLED REPAIR PARTS ON FLOORBEAM AT STA 325 RBL 45 IAW B767 SRM 53-00-51 REPAIR 2.SDR UALA2011111506242Crease Beam · corrodedCORROSION ON CREASE BEAM INNER CHORD AT DOOR L1 STATION 287 - 325 (BOTH LEGS). MAJOR REPAIR ACCOMPLISHED. CORROSION WAS NOT ON CREASE BEAM RATHER THE SPLASH GUARD (NON-PSE). 100 PERCENT MATERIAL LOSS OUT OF LIMITS. REMOVED & REPLACED SPLASH GUARD IAW B767 SSDR UALA2011111406219Controller · faultyL HPSOV AND L BLEED LIGHT CAME ON FOR A MINUTE DURING BEGINNING OF DESCENT. REPLACED AIR SUPPLY CONTROLLER. ACP BITE TEST PER MM PASSED TEST. OK FOR SERVICE.SDR UALA2011111406235Floor Panel · delaminatedRIGHT AISLE AT WING EXT FLOOR SOFT. PANEL DELAMINATION FOUND AT SEAT ROW 21KJ RT AISLE. DELAMINATED AREA IS APPROX ONE FOOT BY ONE FOOT. INTERIM REPAIR PERFORMED PER AMM.SDR UALA2011111406217Battery Pack · faultyCABIN EMERGENCY EXIT FLOOR LIGHTS FLASH ON OFF INTERMITTENTLY. A ZONE, LEFT SIDE EMERGENCY LIGHTS FLICKERING. REPLACED BATTERY PACK AND OP CHECKED.SDR UALA2011111406208Wire · shortedREPEAT WRITE UP CB S11 ENG BLEED CONT POPPED. FOUND 2 WIRES APPROXIMATELY 8" FROM PRESS REGULATING VALVE CONTROLLER CHAFING AND SHORTING. REPAIRED WIRES WITH ENVIRONMENTAL SPLICES, CB NOW OK. RAN ENGINE PER JRH, CHECKS OK.SDR UALA2011111406230Pressure Switch · faultyAPU START FAULT X2. REPLACED OIL PRESSURE SWITCH, OPS CHECKS GOOD.SDR UALA2011111406231Monitor · faultyREPORTED ELECTRICAL BURNING SMELL COMING FROM MONITOR AT ROW 10. READING LIGHTS INOP. BURNING SMELL COMING FROM MONITOR AT 10AB. INOPED MONITOR. RESET READING LIGHT MASTER SWITCH - READING LIGHTS WORK NORMALLY.SDR UALA2011111406184Idg · failedRT IDG FAILURE, RTFL. RIGHT GEN DRIVE LT ON CLIMBOUT WITH ENGINE VIBRATION. REPLACED NR 2 IDG.SDR UALA2011111406232Cap · missingMISSING WINDSHIELD HEAT TERMINAL CAP F/O WINDSCREEN. REPLACED CAP.SDR UALA2011111406218Wire · chafedLEFT ENGINE AIR SUPPLY PRESSURE REGULATING AND SHUTOFF VALVE SUSPECTED OF POPPING CIRCUIT BREAKER. REPLACED LEFT ENGINE AIR SUPPLY PRESSURE REGULATING AND SHUTOFF VALVE. DID NOT HELP POPPING CIRCUIT BREAKER PROBLEM. REPEAT WRITE UP CB S11 ENG BLEED CONT POPPSDR UALA2011111406197Connector · damagedFWD EMERGENCY LIGHT STRIP ON SEAT 1H INOPERATIVE. LIGHT STRIP CONNECTOR DAMAGED. CAPPED AND STOWED WIRES & SECURED. REPLACED LIGHT HARNESS ASSY LIGHT TEST GOOD.
Back to Boeing 767-322