Boeing 767-322
Service difficulty reports · 11,768
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010080902890Charger · faultySTATUS MSG 'MAIN BAT CHRG' ANNUNCIATED. REPLACED CHARGER. MSG CLEARED. BATTERY NEEDS TO BE CHANGED AFTER EXPERIENCING EXCESSIVE CHARGE RATE. REPLACED BATTERY, ALL CHECKS OK ON GROUND.SDR UALA2010080902887Transceiver · faultyWEATHER RADAR FAIL IS INTERMITTENTLY DISPLAYED WITH RADAR SELECTED ON. REPLACED WEATHER RADAR TRANSCEIVER PER MM. OPS NORMAL.SDR UALA2010080902885Exciter · malfunctionedAPU NO START 3 ATTEMPT SWITCH FAULT LIGHT. REPLACED APU IGNITER AND IGNITION EXCITER AS PER MM, OPS CHECKED GOOD.SDR UALA2010080902881Pin · brokenSEAT 4H AFT EEL LIGHT INOPERATIVE. NEED MORE TIME TO FURTHER TROUBLESHOOT, NO POWER TO HARNESS. TROUBLESHOT TO BROKEN WIRE AT FLAT CONNECTOR AISLE LT L300 STA 888, WL 283 RBL 40 PIN ONE WIRE NR W1222-100-20. NEED FLAT PIN CONNECTOR REPAIR. INSTALLED NEW PISDR UALA2010080902880Hydraulic Line · leakingHYDRAULIC LEAK AT LT MAIN LANDING GEAR AREA. MAINT TEXT: AT LEFT MAIN GEAR OUTBOARD OF UPPER TRUNNION, FOUND FLEX LINE LEAKING. REPLACED FLEX LINE, PINED GEARS AND CYCLED GEAR UP AND DOWN 6 TIMES, NO LEAKS NOTED, SERVICED HYD LEVELS AND REPLACED UNDERWING SDR UALA2010080902874Slide · unserviceableTHE 1L ENTRY SLIDE RAFT LACING CABLES FOUND PULLED FROM SLIDE PACK, LEFT SIDE. REPLACED SLIDE ON DOCK WU L0302H.SDR UALA2010080502837Brake · fireNR2 FWD BRAKE FAILED ON LANDING. AFTER SLIDE DEPLOYMENT AT DOOR 1R, REMOVED SLIDE ASSY AND CLOSED DOOR. REPLACED SLIDE-RAFT AT DOOR 1R. ALSO REPLACED BRAKE. OPS NORMAL.SDR UALA2010080502845Shutoff Valve · faultyR PACK OFF EICAS AND PACK OFF LIGHT WITH ENG BLEED ON 32 PSI. SUPPLEMENTAL DATA UPDATE REPLACED LOW LIMIT CONTROL VALVE, NO HELP. REPLACED FLOW CONTROL SHUTOFF VALVE, PACK CHECKED NORMAL.SDR UALA2010080502846Sense Line · damagedFOUND AIR SENSE LINE DAMAGED ON LT SIDE OF NR 2 ENG TURBINE CASE AT STARTING AT APPROX 9 O'CLOCK POSITION, LINE IS RIGID AND APPROX 4' IN LENGTH. REPLACED WITH NEW SENSE LINE. SAFTIED AND SECURED.SDR UALA2010080502844Computer · failedSTATUS MESSAGE "RT EICAS CMPTR" ON TAXI TO GATE. CYCLED RT EICAS COMPUTER C/B, NO HELP. REPLACED RIGHT EICAS COMPUTER. OPS ARE NORMAL.SDR UALA2010080402834Actuator · faultyC HYD SYS MAINT STATUS MSG CAME ON SHORT FINAL. OPERATED C1 AND C2 PUMPS ONE AT A TIME. C2 ONLY PUTTING OUT 2510 PSI. SHOULD BE 2800-3200 PSI. DEFERRED FOR NO TIME. AIR DRIVEN PUMP & C1 PUMP OK. REPLACED C HYD SYS C2 ACMP, NO HELP. SUSPECT PRESS TRANSMITTER SDR UALA2010080402833Shutoff Valve · faultyENGINE BLEED ISSUE. ON SHUT DOWN LT HPSOV BLEED LIGHT ON. REPLACED HPSOV AND CHECKED IAW AMM, NO FAULT PRESENT. AFTER ENG START, UNABLE TO GET ANY BLEED PRESSURE OFF LT ENG. CYCLED LT ENG BLEED CONTROL CB AND NO HELP. REPLACED PRESSURE REGULATING AND SHUTOFF VSDR UALA2010080402813Battery · failedMAIN BATTERY CHARGER STATUS. REPLACED MAIN BATTERY, GROUND CHECKS OKAY.SDR UALA2010080202809Cover · damagedDURING ARRIVAL WALK AROUND FOUND DAMAGE TO ELECTRICAL TRUNKING IN RT MLG WHEELWELL. ACCOMPLISHED REPAIR IAW UA-EVA74006. REPAIR AND ADJACENT AREA TO BE INSPECTED EACH FLT TO ENSURE NO DAMAGE. 287T1030-112 RACEWAY ON PAC (L6836) AND PCN 161-0285 PANEL ON PAC NSDR UALA2010080202777Wire · shortedEDP (ENGINE DRIVEN PUMP) HYD PWR. POS 2O1=L,O2=R) EDP HYD LOW PRESS LGT ILLUM. EICAS MSG DISPLAYED (LT,RT) HYD PRIM PUMP. EICAS MSG (LT,RT) HYD SYS MAINT (WAS, WAS NOT) DISPLAYED. CREW COMMENTS: PUMP AND SYS LO PSI LIGHT ON WITH R ELEC DEMAND SWITCH IN AUTO OSDR UALA2010080202806Light · obstructedBOTH LT AND RT EMERGENCY LIGHTS AT FWD LAV COVERED OVER WITH CARPET. TRIMMED CARPET TO EXPOSE EMERGENCY LIGHT. LIGHTS BACK IN TOLERANCE.SDR UALA2010080202805Battery Pack · inoperativeRT SIDE EMERGENCY LIGHTS INOP IN BOTH FIRST AND BUS CLASS. REPLACED DEFECTIVE BATTERY PACK. OPS ARE NOW NORMAL.SDR UALA2010080202779Switch · faultyRIGHT ENG OIL FILTER EICAS AND STATUS LIGHT ON AFTER ENG START. SWITCH HAS MALFUNCTIONED. REPLACED OIL FILTER AND BYPASS SWITCH PER MM.SDR UALA2010080202804Light · inoperativeX AISLE LIGHT INOP FRONT GALLEY. REPLACED LIGHT STRIP.SDR UALA2010080202778Engine · crackedENG FAILED BORO INSPECTION EC6271 CONTINUOUS LOUVER CRACK THROUGH KNUCKLES. REPLACED NR 1 ENGINE. FUEL INJECTOR GUIDE AND HEATSHIELD IS ROTATED 45 DEG FROM IT'S NORMAL POSITION, LOCATED AT THE APPROX 12 O'CLOCK POSITION. RVI PICS SENT SFOLM EMC CONTACTED. ISDR UALA2010080202759Wire · damagedEICAS MSG R GEN OFF DISPLAYED. GEN OFF & FIELD OFF LIGHTS ILLUM & FAILED TO RESET. FUEL WAS SUFFICIENT FOR APU OPERATION FOR THE REST OF FLIGHT. DISCONNECTED IDG AND TAPED OVER IDG DISCONNECT AND LOW PRESS SWITCH. IDG REPLACED. TROUBLESHOT AND FOUND DAMAGESDR UALA2010080202794Light · inoperativeEMERGENCY LIGHT IN FC GALLEY INOP. REPLACED LIGHT AND STRIPS. OPS CHECKS GOOD.SDR UALA2010080202795Connector · damagedRIGHT NR 7 SPOILER BLOWDOWN ACTUATOR CONNECTOR PINS BENT. REMOVED AND REPLACED SQUIB WITH NEW SQUIB IAW MM.SDR UALA2010080202769Charger · faultyMAIN BATTERY CHARGER EICAS MESSAGE. CHARGER FOUND FAULTY. REPLACED BATTERY CHARGER AND MESSAGE CLEARED.SDR UALA2010080202762Structure · dentedBULK CARGO DOOR LOWER FWD CORNER HAS (2) DENTS. (1) DENT IS 0.5 INCH BY 0.25" DEEP AND THE OTHER 1.0 INCH BY 0.O50 INCH. BOTH DENTS ARE 2 INCHES FROM DOOR EDGE AT LOWER FWD CORNER. CUT-OUT DAMAGED AREA AND FABRICATED A REPAIR FILLER AND DOUBLER AND INSTALLEDSDR UALA2010073002752Shutoff Valve · malfunctionedRIGHT ENG BLEED LIGHT & RT ENG HPSOV EICAS MSG, ENG BLEED SW OFF & ENG RUNNING, LT & RT DUCT PRESS ARE ON. BLEED LIGHT ALSO ON PRESSURE ALMOST 0-3 PSI. HPSOV LOCKED CLOSED. REPLACED HPSOV AND HPSOV CONTROLLER, OPS CHECK GOOD.SDR UALA2010073002745Fuel Line · damagedNR 2 ENGINE FUEL LINE FROM FUEL-OIL COOLER 'FUEL OUT' LINE TO FUEL PUMP INSULATION DAMAGED. REMOVED FUEL LINE. COMPLETED INSTALLATION, LEAK CHECKED GOOD. REPLACED FUEL PUMP. OPS & LEAK CHECKED GOOD.SDR UALA2010072802716Pump · faultedBSTR PUMP LOW PRESS LIGHT-ON, RTFL. REPLACED RT AFT BOOST PUMP. FOUND R AFT FUEL BOOST PUMP CB (G21) TRIPPED. REPLACED CIRCUIT BREAKERS C371, C370 AND WIRES CONNECTED TO CB'S. ALL BOOST PUMPS TEST GOOD.SDR UALA2010072802726Light · obstructedCARPETING IS COVERING THE FLOOR PATH (EEL) LIGHTS AT LEFT FWD AISLE NEXT TO FWD LAV. AT RIGHT FWD AISLE NEXT TO FWD GALLEY. AT LEFT AISLE MID LAV. AT RIGHT AISLE MID LAV. SUPPLEMENTAL DATA UPDATE TRIMMED CARPETS AT LEFT AND RIGHT AISLE NEXT TO MID LAVS, FWD AISDR UALA2010072802724Connector · defectiveFLOOR PROXIMITY EMERGENCY LIGHT AT FWD ENTRY CROSSAISLE IS INOPERATIVE. REPLACED CONNECTOR. TESTS OKAY.SDR UALA2010072902737Wire · chafedPER CREW AFTER ENGINE START THE HAVE L ENG EEC C1 STATUS MSG. FOUND WIRE GOING TO FMU CHAFING AND CONTACTING REV COWL. INSULATION WORN REPAIR PER GNMM. RAN ENG AND OPS CHECK NORMAL.SDR UALA2010072802730Transceiver · faultyWEATHER RADAR FAIL DISPLAYED ON HSI. WEATHER RADAR FAIL RT DISPLAYED ON HSI WHEN IN WEATHER RADAR TEST. WX FAIL & RT DISPLAYED ON HSI IN FLT. REPLACED WEATHER RADAR TRANSCEIVER IAW MM, SYS TESTS NORMAL.SDR UALA2010072802728Connector · unsecureFLOOR PROXIMITY EMERGENCY LIGHT IS INOP AT THE LT AISLE MID LAV. SECURED BATTERY CONNECTOR. CHECKS GOOD.SDR UALA2010072802727Connector · unsecureFLOOR PROXIMITY EMERGENCY LIGHT IS INOP AT ROW 19 CROSS AISLE. SECURED BATTERY CONNECTOR. CHECKS GOOD.SDR UALA2010072802725Light · inoperativeFLOOR PROXIMITY EMERGENCY LIGHTS ARE INOP AT LT AISLE NEXT TO THE FWD LAV. REPLACED LIGHT ASSY. TESTS OK.SDR UALA2010072802723Actuator · leakingEVIDENCE OF HYD FLUID ON BOTTOM OF LT ELEVATOR. INSPECTED AND FOUND LT ELEVATOR MIDDLE PCA FOR RT HYD SYS LEAKING. REPLACED LT SIDE ELEVATOR PCA (MIDDLE ONE). ACTUATOR IN AND SECURED. CLOSING UP.SDR UALA2010072802717Fan · failedFWD EQ COOLING MSG, FLIGHT DIVERTED. REPLACED M867. ALSO REPLACED RELAY K626, EQUIP COOLING NOW TESTS OK. REPLACED FWD RACK EXHAUST FAN. SYS OPERATED IN GROUND MODE AND FLT MODE, NO FAULTS. REPLACED OVERRIDE VALVE IAW AMM 21-58-20. OP-CHECK NORMAL. RECEIVESDR UALA2010072802731Filter · failedAPU INOP. AUTO SHUTSDOWN 10 SECONDS AFTER REACHING 95 PERCENT RPM. APU FAULT LIGHT ON. REFER TO MM-49-61-00, CODE C6. BITE APU BOX FOUND GEN FILTER MESSAGE. REPLACED GEN SCAVENGE FILTER IAW AMM. SERVICED OIL TO FULL. OPS CHECKED NORMAL.SDR UALA2010072702709Guard · looseEEL LIGHT SWITCH GUARD ON FLIGHT DECK OVERHEAD PANEL IS LOOSE. SECURED GUARD.SDR UALA2010072702708Battery · dischargedLOWER EEL EXIT SIGN BY RIGHT AFT OVERWING EXIT DOOR IS INOP. BY- 116760 REPLACED BATTERY, CHECKS GOOD.SDR UALA2010072702707Battery · dischargedEEL LOWER EXIT SIGN BY FWD RIGHT OVERWING EXIT DOOR IS INOPERATIVE. REPLACED BATTERY, CHECKS GOOD.SDR UALA2010072702706Battery · dischargedEMERGENCY FLOOR STRIP BY RIGHT MID LAV IS INOP. REPLACED BATTERY, CHECKS GOOD.SDR UALA2010072702701Control Panel · faultyCABIN ALTITUDE CONTROL PANEL UNABLE TO SET LANDING ALTITUDE. REPLACED PANEL, OPS OK.SDR UALA2010072702699Contact · dirtyEXTERIOR EEL LIGHT BY DOOR 1 RIGHT IS INOPERATIVE. RELAMPED, NO HELP. CLEANED AND ADJUSTED LAMP CONTACTS, CHECK OKAY.SDR UALA2010072602681Transmitter · fluctuatesLT HYD QTY FLUCTUATING. REMOVED AND SECURED PTU SIGNAL WIRE AND WILL REQUIRE RECONNECTION IAW MEL ITEM. SYS IS INOP IAW MEL. QUANTITY VERIFIED. QTY NORMAL AND LOW PRESSURE LIGHT IS OPERATIVE. REPLACED LT HYD TRANSMITTER IAW MM. NO LEAKS NOTED. RECONNECTSDR UALA2010072702692Battery Pack · failedRT OVERWING SLIDE SQUIB FAILS TEST WHEN ACCOMPLISHING TEST 1. REPLACED BATTERY PACK AND POWER SUPPLY AND ACCOMPLISHED SQUIB TEST. OPS CHECK NORMAL, NO EICAS MESSAGES.SDR UALA2010072602648Pump · failedCTR HYD DEM PUMP FAILURE, FLIGHT DIVERTED. REPLACED CENTER HYDRAULIC SYSTEM AIR DRIVEN PUMP. ALSO REPLACED CENTER SYSTEM AIR DRIVEN PUMP PRESSURE AND CASE DRAIN FILTERS, NO SMALL METAL PARTICLES FOUND IN BOWL AND ELEMENTS OF FILTERS. ACFT RELEASED BACK TO SDR UALA2010072602677Vane · damagedNR 1 ENGINE, REPLACE REV CASCADE VANE SEGMENTS 8 AND 9 ON THE LT REV HALF REFERENCE MM. NO DAMAGE ALLOWED. REPLACED CASCADE SEGMENT.SDR UALA2010072602655Warning System · activatedDURING TAXI, NOTICED AN OVERHEAD EMERGENCY DOOR ILLUMINATED ALONG WITH A RIGHT WING SLIDE EICAS MESSAGE. STARTED DISARM OF OFF WING ESCAPE SYS FOR T/S. REMOVED AIR GRILL FOR ACCESS. REF OFF WING ESCAPE SYS RT MM. RE-INSTALLED AIR GRILLES. OPS NORMAL.SDR UALA2010072602691Connector · dirtyGROUND HANDLING TRU CB ON P34 POPPED. REPLACED TRU AND TRU CB PER MM, NO HELP. CB APPEARED TO POP WHEN UNDER LOAD AND WOULD ONLY STAY IN WHEN FWD AND AFT CARGO HANDLING CBS WERE PULLED. REMOVED AND CLEANED CONNECTOR D4926P. INSPECTED WIRING IN P34 PANEL AN
Back to Boeing 767-322