SDR 2008UALA03618Stringer · corrodedFWD PIT BS 785.9, S-39R STRINGER END FITTING IS CORRODED. REPLACED STRINGER END FITTING. INSTALLED FITTING.SDR 2008UALA03622Transmitter · malfunctionedFLIGHT CREW REPORT SLIGHT SPLIT BETWEEN LEFT AND RIGHT T/E FLAP INDICATOR NEEDLES NORMAL AT 1 AND 25 BUT SLIGHT SPLIT AT UNITS 5, 10 & 15. REPLACED LEFT FLAP POSITION TRANSMITTER NR 1 PER AMM CH 27-51-45 OP CHECK NORMAL. AC OK FOR SERVICE.SDR 2008UALA03599Valve · faultyDEBRIEFED CREW AND NOTED ON APPROACH AT APPROX 4K FEET AND EQUIP COOLING POS ON OVERRIDE, THE "NO COOLING" LIGHT ILLUMINATED UNTIL ACFT BLOCKED INTO GATE. AFTER EXTENSIVE TROUBLE SHOOTING FOUND FAULTY OVERRIDE VALVE AND EQUIPMENT COOLING CARD. REPLACED COOLISDR 2008UALA03614Bushing · out of positionNR 1 PYLON INBOARD MID SPAR FITTING BUSHING MIGRATED .035 NO CORROSION OR ROTATION.SDR 2008UALA03613Bushing · out of positionNR 2 PYLON INBOARD MID SPAR FITTING BUSHING MIGRATED .030 NO CORROSION OR ROTATION.SDR UALA2008111303580Indication Sys · malfunctionedEICAS MESSAGES T/E FLAP DISAGREE & T/E FLAP SHUTDOWN DISPLAYED. CREW COMMENTS: FLAPS DISAGREE FROM 20 TO 25. RAN L/E AND T/E DEVICES THRU SEVERAL CYCLES AND OPERATED IN RAPID FLAP POSITION CHANGES. OPERATION APPEARS NORMAL. FSEU BITE=NO FAULTS. MESSAGE CSDR 2008UALA03585Heat Exchanger · faultyCREW COMMENTS: GOT HOT IN CABIN 74-79-81, HAVE TO OPERATE RT PACK IN STBY C TO HAVE A COMFORTABLE TEMP. *S/D* SUSPECT FAULTY HEAT EXCHANGER. REPLACED LEFT HEAT EXCHANGER IAW MM 21-51-02, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03581Compressor · stalledLEFT ENGINE COMPRESSOR STALL WHEN THROTTLES ADVANCED. ALSO OCCURRED DURING REVERSER OPERATION. UNABLE TO FIND ANY DAMAGE TO ACCOUNT FOR THE REPORTED STALL. ADDITIONALLY, NO SURGE FLAG WAS SET. BECAUSE OF REPEATED POWERPLANT INTERFACE MANAGEMENT UNIT (PIMU) SDR 2008UALA03580Warning System · activatedEICAS MESSAGES T/E FLAP DISAGREE & T/E FLAP SHUTDOWN DISPLAYED.
SDR UALA2008111303552Structure · damagedDAMAGE TO LWR CHORD IN LT AC BAY ABOVE PLENUM. MAJOR REPAIR ACCOMPLISHED. AFTER HEAT TREAT AND CAD PLATING INSTALLED ANGLES, STRAP AND CHORD SECTION. LOWER CHORD REPAIRED PER UA-EVA-71685.SDR 2008UALA03572Spring · weakAFT LT SVC DOOR DEPLOYMENT BAR GAS SPRING IS WEAK. REPLACED GAS SPRING IAW MM 25-66-03. AC OK FOR SERVICE.SDR 2008UALA03571Spring · weakAFT RT SVC DOOR DEPLOYMENT BAR GAS SPRING IS WEAK. FOUND WEAK GAS SPRING IN DEPLOYMENT BAR SERVICE DOOR. REPLACED GAS SPRING IAW MM 25-66-03. AC OK FOR SERVICE.SDR 2008UALA03553Web · crackedNR 2 PYLON UPPER WEB CRACKED, NAC STA 182 AT FWD OUTBD CORNER OF FEED THROUGH CUTOUT. FOUND CRACKED WEB SUSPECT NORMAL AC OPERATION. REPAIRED CRACK IAW SB 767-54-0091 FIG 10. AC OK FOR SERVICE.SDR 2008UALA03552Structure · damagedDAMAGE TO LWR CHORD IN LT AC BAY ABOVE PLENUM.SDR 2008UALA03523Lamp · inoperative29H EEL LIGHT INOP. SUSPECT FAULTY LAMP. REPLACED LAMP OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03566Pressure Switch · faultyEICAS MSG STAB TRIM DISPLAYED & STAB TRIM LIGHT ILLUMINATED. STABILIZER TRIM RATE NORMAL. FOUND FAULTY PRESSURE SWITCH. REPLACED RT STAB MODULE BRAKE PRESSURE SWITCH. PER MM 27-41-07. OPS CHECK GOOD, LEAK CHECK GOOD, AC OK FOR SERVICE.SDR 2008UALA03532Lamp · looseEMERGENCY ESCAPE PATH LIGHTING LOOSE AT ROW 1, RIGHT SIDE. FOUND LOOSE LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03531Angle · crackedUPON REMOVAL OF GALLEY TIE ROD ATTACH PLATE THE L-ANGLE STRINGER WAS DAMAGED, FASTNER REMOVAL CAUSED END OF ANGLE TO CRACK OFF. REPAIRED IAW SRM 51-20-01 AND SRM 51-40-02.SDR UALA2008111303487Guard · corrodedMAIN CABIN FLOOR SUPPORT ANGLE SPLASH GUARD HAS CORROSION AT BS 285 AND RBL 83. REMOVED & REPLACED SPLASH GUARD.SDR 2008UALA03486Floorbeam · crackedMAIN CABIN FLOORBEAM AT BS 246, AFT FACE UPPER ANGLE CRACKED, LBL 11. *S/D* FOUND UPPER CHORD CRACKED. REMOVED DAMAGE, FABRICATED NEW UPPER CHORD AND INSTALLED IAW SRM 53-10-51.SDR 2008UALA03487Floor Support · corrodedMAIN CABIN FLOOR SUPPORT ANGLE -SPLASH GUARD- HAS CORROSION AT BS 285 AND RBL 83.SDR 2008UALA03468Seal · noisyWINDOW SEAL BEGAN TO SQUEAL LOUDLY. CAPTAIN REPORTED, NOISE IS TOO LOUD TO OPERATE SAFELY, RTFL. REPLACED SEAL. APPLIED SEALANT AROUND FILLET. PERFORMED PRESSURE CHECK. ALL CHECKS NORMAL.
SDR 2008UALA03485Power Supply · malfunctionedEMERGENCY ESCAPE PATH LIGHTING COMES ON FROM ROW 28 TO DOOR 2R (ONLY ON RIGHT SIDE OF A-C). AFTER TROUBLESHOOTING FOUND FAULTY POWER SUPPLY. REPLACED POWER SUPPLY M734 AND OPS CHECKS OK. AC OK FOR SERVICE.SDR 2008UALA03466Structure · damagedLT FWD NLG DOOR SKIN HAS A LIGHTNING STRIKE APROX 17 INCHES AFT OF LEADING EDGE OF DOOR AND 7.75 INCHES FROM INBOARD EDGE OF DOOR. *S/D* FOUND LIGHTNING STRIKE IN NOSE LANDING GEAR DOOR. REMOVED DAMAGE TO LT FWD NLG DOOR AND INSTALLED COMPOSITE REPAIR PER SSDR 2008UALA03464Floorbeam · corrodedCORROSION FOUND AT BS 805, LBL 11, UNDER MAIN CABIN FLOOR. *S/D* SUSPECT MOISTURE CONTAMINATION. CUT OUT DAMAGED SECTION OF T-CAP SPLICED IN NEW SECTION PER SRM 53-00-51, SRM 51-20-01 AND SRM 51-40-02. AC OK FOR SERVICE.
SDR 2008UALA03451Idg · faultyL GEN DRIVE LIGHT CONTINUOUSLY FLICKERS IN FLIGHT. GEN WORKS NORMALLY. *S/D* SUSPECT FAULTY INTEGRATED DRIVE GENERATOR. REPLACED LEFT IDG PER MM 24-11-01, ALL OPS AND INDICATE NORMAL. AC OK FOR SERVICE.SDR 2008UALA03465Stiffener · crackedE&E COMPARTMENT AT STA 246 FLOORBEAM AND LBL 40 HAS CRACKED VERTICAL STIFFENER. REPLACED CRACKED STIFFENER. FABRICATED & INSTALLED NEW REPAIR.SDR 2008UALA03445Floorbeam · wornMAIN CABIN FLOORBEAM UPPER SURFACE HAS WEAR MARKS AROUND FASTENER HOLE AT BS 764 BETWEEN RBL 20 AND RBL 54. *S/D* SUSPECT TOOLING MARKS. REMOVED DAMAGE AREA, FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-51 FIG 201 TABLE I. AC OK FOR SERVICE.SDR 2008UALA03448Connector · looseEEL LIGHT AT SEAT 33H INOPERATIVE. FOUND LOOSE CONNECTION. SECURED CONNECTION. AC OK FOR SERVICE.SDR 2008UALA03447Connector · looseEEL LIGHT AT SEAT 25H INOP. FOUND LOOSE CONNECTION. SECURED CONNECTION. AC OK FOR SERVICE.SDR 2008UALA03446Connector · looseEEL LIGHT AT SEAT 32A INOP. FOUND LOOSE CONNECTION. SECURED CONNECTION. AC OK FOR SERVICE.SDR 2008UALA03444Floorbeam · corrodedCABIN FLOORBEAM AT BS 805, RBL 11 IS CORRODED. REMOVED DAMAGE, FABRICATED NEW REPAIR AND INSTALLED IAW SRM 53-00-51 AND SRM 51-40-02. AC OK FOR SERVICE.SDR 2008UALA03443Floorbeam · crackedSTA 303, RBL 88.5, CRACK ON FLOORBEAM. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED T-CHORD, REPAIR SPLICE & STRAP.SDR 2008UALA03438Actuator · malfunctionedON LANDING LOST ALL HYDRAULIC FLUID LEFT SIDE. FOUND FAULTY ACTUATOR. REPLACED NR 6 SPOILER IN BOARD ACTUATOR PER MM27-61-01 OP AND PRESS CHECK NORMAL. AC OK FOR SERVICE.SDR 2008UALA03404Barrel · unserviceableLEAKING BARREL. REPLACED BARREL. READY FOR SERVICE.SDR 2008UALA03413Pressure Switch · leakingL HYD QUANTITY ZERO. RAMP NOTES, FLUID LEAKING FROM LEFT ENGINE. PACKING IN LT SYSTEM PRESSURE SWITCH TORN. REPLACED SWITCH AND PACKING. SERVICED HYDRAULIC RESERVOIR AND PRESSURE CHECKED OP CHECK NORMAL. AC OK FOR SERVICE.SDR 2008UALA03370Idg · faultyRT GEN DRIVE LIGHT AND EICAS ILLUM. DISCONNECTED RT GEN PER IRREG, APU ON LINE. REPLACED RIGHT ENG. IDG IAW MM24-11-01 OP CHECKED GOOD, AC OK FOR SERVICE.SDR 2008UALA03369Switch · faultyLEFT HYDRAULIC SYSTEM FAILURE. RTFL. FOUND FAULTY SWITCH. REPLACED S30 SWITCH OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03437Switch · faultyPRESS LIGHT DO NOT COME ON WHEN RIGHT ELECTRIC DEMAND PUMP IS TURNED OFF. FOUND FAULTY SWITCH. REPLACED S30 SWITCH OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03401Fan · shortedFWD EQUIP SUPPLY FAN STATUS MSG SHORTLY AFTER LANDING. BURNING SMELL IN COCKPIT FOR 4 MINS. SUSPECT EQUIPMENT SUPPLY FAN SHORTED. REPLACED FAN PER MM 21-58-06. TEST NORMAL. AC OK FOR SERVICE.SDR 2008UALA03400Duct · crackedLT PACK INOPERATIVE - REHEATER INLET DUCT CRACKED. *S/D* SUSPECT IMPROPER INSTALLATION. REPLACED LT PACK REHEATER DUCT PER MM 21-51-21. OP CHECKS NORMAL. AC OK FOR SERVICE.SDR 2008UALA03368Shutoff Valve · faultyEQUIPMENT COOLING FAN EICAS MESSAGE. AFTER TROUBLESHOOTING FOUND SHUTOFF VALVE TO BE FAULTY. REPLACED VALVE PER MM 21-23-08, ALL OPS & INDICATIONS NOW NORMAL. AC OK FOR SERVICE.SDR 2008UALA03367Blower · faultyEQ COOLING OVERHEAT INDICATION. RTFL. AFTER TROUBLESHOOTING SUSPECT FWD CARGO DETECTOR BLOWER AT FAULT. REPLACED FWD CARGO DETECTOR 2. MSG CLEARED. TEST NORMAL. REPLACED EQUIP COOLING FWD RACK EXHAUST FAN ACCT NOISY. EQ COOLING EXHAUST HAS LOW AIR FLOW. REMSDR 2008UALA03357Chiller · trippedSMOKE POSSIBLY ELECTRICAL IN BUSINESS GALLEY IN FLT. ALL POWER TO GALLEY SECURED. *S/D* FOUND CHILLER CIRCUIT BREAKER TRIPPED. REPLACED MID FWD GALLEY CHILLER, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03341Idg · faultyAT TOC HAD LEFT ELEC BUSS POWER PROBLEM OF A TRANSITORY NATURE WHICH MOMENTARILY BLANKED CAPT'S EADI AND EHSI. *S/D* SUSPECT FAULTY BEARING IN IDG. REPLACED NR 1 IDG ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03360Motor · faultyCABIN ALT AUTO 1 STATUS MSG. *S/D* AFTER TROUBLESHOOTING FOUND OUT FLOW VALVE MOTOR TO BE FAULTY. REPLACED NR 1 (AFT) AC OUTFLOW VALVE MOTOR PER MM 21-31-05, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03358Battery Pack · faultyEMERGENCY PATH LIGHTS & WINDOW 'EXIT' LIGHTS FLASHING ON-OFF DURING FLIGHT. *S/D* SUSPECT BATTERY. REPLACED BATTERY PACK. AC OK FOR SERVICE.SDR 2008UALA03340Power Supply · faultyTHREE OVERWING AND DOOR 1L EMERGENCY LIGHTS WON'T COME ON. *S/D* SUSPECT FAULTY POWER SUPPLY. REPLACED POWER SUPPLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03350Angle · crackedMAIN CABIN UNDER FLOOR, INTERCOSTAL UPPER ANGLE CRACKED BETWEEN BS 742 AND BS 764, AND RBL 40. MAJOR REPAIR ACCOMPLISHED: INSTALLED NEW ANGLE (P/N OA00002UD).SDR 2008UALA03359Shutoff Valve · faultyNR 1 ENG PRSOV FAILED HEALTH CHECK REFERENCE PRESSURE LOW. *S/D* DURING HEALTH CHECK FOUND PRESSURE REGULATING SHUT OFF VALVE FAULTY. REPLACED PRSOV. AC OK FOR SERVICE.