Boeing 767-322

Service difficulty reports · 11,768

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '767322'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2007UALA02841Light · inoperativeEMERGENCY EEL LIGHTS AT SEATS 20AB TO 23AB INOP, EMERGENCY EXIT DOORS.Jul 25, 2007 · N668UA · Boeing 767322 · Emergency LightingSDR 2007UALA02840Light · shortedMID GALLEY CROSSAISLE EMERGENCY EEL STRIP INOP. REPLACED EEL STRIP AT CROSSAISLE MID GALLEY.Jul 25, 2007 · N668UA · Boeing 767322 · Emergency LightingSDR 2007UALA02822Engine · stalledNR 2 ENG APPEARED TO SUSTAIN A STALL DURING WAKE TURB ENCOUNTER. ALL ENG PARAMETERS REMAINED NORMAL AND ENG CONTINUED TO OPERATE NORMALLY. [08-14-07] BORESCOPE OF HPC PER AMM 72-00-00 SHOWED NO DAMAGE. BLEED SYSTEM CHECKED NORMAL. ALL OTHER CHECKS WERE WJul 24, 2007 · N676UA · Boeing 767322 · Engine (Turbine/Turboprop)SDR 2007UALA02821Wire · brokenEEL LEAD WIRE BROKEN. REMOVED AND REPLACED EEL LIGHT BARS PER MM 33-51-10 AND OPS CHECK GOOD PER MM 33-51-00 ON N-R 25692.Jul 24, 2007 · N649UA · Boeing 767322 · Light System WiringSDR 2007UALA02820Lamp · inoperativeRIGHT SIDE EXTERNAL OVERWING EMERGENCY EXIT LIGHT IS INOPERATIVE. TROUBLESHOT AND FOUND BAD LAMP. REMOVED AND REPLACED LAMP. OPS CHECKS GOOD.Jul 24, 2007 · N649UA · Boeing 767322 · Emergency LightingSDR 2007UALA02819Cap · looseF/A REPORTS AISLE LIGHT AT SEAT 1B END CAP IS COMING OFF. INSTALLED CAP AND SECURED CONNECTOR AND EEL CHECKS GOOD.Jul 24, 2007 · N647UA · Boeing 767322 · Emergency LightingSDR 2007UALA02818Light · missingEEL LIGHT MISSING BY SEAT 2E. INSTALLED LIGHT. CHECKS GOOD.Jul 24, 2007 · N647UA · Boeing 767322 · Emergency LightingSDR 2007UALA02817Light · inoperativeLARGE AFT GALLEY EEL STRIP IS INOPERATIVE. REPLACED EEL STRIP. CHECKS GOOD.Jul 24, 2007 · N647UA · Boeing 767322 · Emergency LightingSDR 2007UALA02816Connector · unsecureFWD LEFT AND MID LEFT LAV FLOOR EEL STRIPS ARE INOPERATIVE. SECURED CONNECTOR. CHECKS GOOD.Jul 24, 2007 · N647UA · Boeing 767322 · Emergency LightingSDR 2007UALA02781Fuel Sys · leakingFLIGHT DIVERTED & LANDED UNDER AMBER ALERT DUE TO A FUEL LEAK INDICATION.Jul 22, 2007 · N673UA · Boeing 767322 · Aircraft Fuel SystemSDR 2007UALA02779Light · unsecureEMERGENCY STRIP LIGHTING IN FIRST CLASS IS LOOSE. [08-14-07] RESECURED STRIP LIGHT.Jul 22, 2007 · N648UA · Boeing 767322 · Emergency LightingSDR 2007UALA02778Light · unsecureEMERGENCY FLOOR LIGHTS 2EF SOME LIGHTS ARE INOP. [08-14-07] SECURED LIGHT STRIP. OP CHECKS OK FOR SERVICE.Jul 22, 2007 · N648UA · Boeing 767322 · Emergency LightingSDR 2007UALA02777Light · inoperativeTHE 27A EMERGENCY FLOOR LIGHTS INOPERATIVE. [08-14-07] FOUND CUT IN CABLE ASSY. SPLICED CUT STRIP. TESTS OK.Jul 22, 2007 · N648UA · Boeing 767322 · Emergency LightingSDR 2007UALA02796Transmitter · malfunctionedL ENG OIL PRESSURE IS RED 0. [08-07-07] REPLACED OIL PRESSURE TRANSMITTER PER AMM 79-32-01. OPS CHECKED NORMAL.Jul 21, 2007 · N675UA · Boeing 767322 · Engine Oil PressureSDR 2007UALA02780Light · illuminatedFLOOR EMERGENCY EXIT LIGHTS ARE ILLUMINATED ROW 5 THRU 10 RIGHT SIDE ONLY IN CRUISE. [08-14-07] CHECKED WIRING TO BATTERY PACK, UNABLE TO DUPLICATE, GROUND CHECKED OK PER MM33-51-00. NO REPEAT WRITE-UP IN SUCCEEDING 21 DAYS.Jul 21, 2007 · N654UA · Boeing 767322 · Emergency LightingSDR 2007UALA02776Light · damagedFLOOR EEL STRIP AT DOOR 1L CLOSET HAS BEEN DAMAGED AND IS INOP. [08-14-07] REPAIRED EEL STRIP AT DOOR 1L CLOSET.Jul 21, 2007 · N644UA · Boeing 767322 · Emergency LightingSDR 2007UALA02746Light · inoperativeEEL INOP IN AISLE AFT OF MED 1L. REPAIRED FLOOR-MOUNTED EEL PER MM 33-51-10.Jul 19, 2007 · N648UA · Boeing 767322 · Emergency LightingSDR 2007UALA02745Stiffener · crackedCABIN FLOORBEAM STA 246 VERTICAL STIFFENER AT FWD FACE, RBL 11, CRACKED AT BEND RADIUS. [08-14-07] REMOVED AND REPLACED VERTICAL STIFFENER PER SRM 53-10-51, PARAGRAPH 3. AIRPLANE READY FOR SERVICE. SUSPECT FATIGUE EXACERBATED BY ASSEMBLY PRE-LOAD.Jul 19, 2007 · N649UA · Boeing 767322 · Fuselage Main, Floor BeamSDR 2007UALA02733O-Ring · leakingRIGHT WING FUEL TRANSFERRING INTO CENTER FUEL TANK AT A RATE OF 350LBS PER HOUR. FOUND LEAKY COUPLING IN CENTER RIGHT AUX TANK UPPER RIB, SCAVENGE LINE TO CENTER TANK, ORDERED PACKING PCN 750-7006. FOUND THE RIGHT CENTER AUX SCAVENGE LINE LEAKING. REPLACED Jul 18, 2007 · N654UA · Boeing 767322 · Aircraft Fuel Distribution SystemSDR 2007UALA02720Floor Panel · gougedFWD CARGO PIT TORQUE FLOOR GOUGED FWD AND AFT OF PDU 8C, RBL 5, STA 560. [08-14-07] FOUND OUT OF LIMITS. FABRICATED NEW PANEL PER BAC DWR 451T2504. INSTALLED NEW PANEL PER SRM51-40-02. AIRPLANE RETURNED TO SERVICE READY.Jul 18, 2007 · N649UA · Boeing 767322 · Fuselage Floor PanelSDR 2007UALA02719Connector · damagedFLOOR MOUNTED EEL LIGHTS INOP RIGHT SIDE IN F-C. FLOOR MOUNTED CONNECTOR HAS BEEN DAMAGED. [08-14-07] FLOOR MOUNTED CONNECTOR HAS BEEN DAMAGE BY CLEANERS. -RPR-:REPAIRED FLOOR-MOUNTED EEL PER MM 33-51-10.Jul 18, 2007 · N648UA · Boeing 767322 · Light System WiringSDR 2007UALA02718Cap · out of positionF/A REPORTS AISLE LIGHT AT SEAT 1B END CAP IS COMING OFF. [08-14-07] SHORT EEL STRIP IN FRONT OF END CAP HAS BROKEN END PINS AND DOES NOT ILLUMINATE. REPLACED EEL STRIP. AIRPLANE OK FOR SERVICE.Jul 18, 2007 · N647UA · Boeing 767322 · Emergency LightingSDR 2007UALA02681Light · inoperativeMID GALLEY EEL FLOOR STRIP IS INOPERATIVE. REPLACED EEL STRIP CHECKS GOOD.Jul 16, 2007 · N674UA · Boeing 767322 · Emergency LightingSDR 2007UALA02689Apu · shutdownAPU AUTO SHUTDOWN. [08-17-07] RESET APU ENGINE CONTROL UNIT. APU CK'S OK. AIRPLANE RETURNED TO SERVICE.Jul 16, 2007 · N658UA · Boeing 767322 · APU Core EngineSDR 2007UALA02682Feeder Cable · inoperativeEEL LIGHT ON SEAT 13A IS INOPERATIVE. [08-17-07] REPLACED SEAT CABLE. CHECKS GOOD.Jul 16, 2007 · N674UA · Boeing 767322 · Light System WiringSDR 2007UALA02652Wire Harness · damagedELECTRICAL BURNING ODOR WITH SMOKE FROM MID GALLEY (416) AFT COUNTER HOTPLATE AREA. C/B FOR HOTPLATE H41 HAS BEEN PULLED AND BURNING ODOR AND SMOKE HAS DISSIPATED. HOTPLATE WAS NOT HOT BUT AREA AROUND HOTPLATE WAS HOT, POSSIBLE DAMAGED WIRING HARNESS. [08-1Jul 15, 2007 · N659UA · Boeing 767322 · Electrical Power System WiringSDR 2007UALA02651Lamp · inoperativeEXTERNAL EEL LIGHT JUST AFT OF LEFT WING IS INOP. [07-27-07] RELAMPED AND LIGHT CHECKS GOOD.Jul 15, 2007 · N652UA · Boeing 767322 · Emergency LightingSDR 2007UALA02656Oil Cooler · failedAPU FAILED DURING TAXI OUT WITH FAIL LIGHT ILLUMINATED. [08-17-07] REPLACED OIL COOLER RAN APU WITH FULL LOAD 35 MIN, AND NO AUTO SHUTDOWN. OPS CHECK NORMAL AT THIS TIMEJul 14, 2007 · N677UA · Boeing 767322 · APU Oil SystemSDR 2007UALA02655Wire · brokenFWD GALLEY CROSS AISLE EEL STRIP INOP. [08-17-07] REPAIRED BROKEN EEL EXTENSION, OPS CK OK.Jul 14, 2007 · N664UA · Boeing 767322 · Light System WiringSDR 2007UALA02654Connector · unsecureEEL STRIP AT DOOR 1L AFT LAV INOP. [07-27-07] SECURED LOOSE CONNECTOR, OPS CK OK.Jul 14, 2007 · N664UA · Boeing 767322 · Light System WiringSDR 2007UALA02653Light · inoperativeFWD EEL LIGHT AT SEAT 1HJ AND LIGHTS AT SEATS 12AB & 29AB ARE INOPERATIVE. [07-27-07] REPLACED EEL STRIP, OPS CK OK.Jul 14, 2007 · N664UA · Boeing 767322 · Emergency LightingSDR 2007UALA02627Transformer · out of rigCAPTAIN REPORTED, T/E FLAP DISAGREE ON FINAL. [08-17-07] FSEU BITE CARRIED OUT WITH FLAP HANDLE SET FOR 30 AND READOUT SHOWING 20. THIS CONFIG RESULTED FROM THE FLAP LEVER ROTARY VARIABLE DIFFERENTIAL TRANSFORMER BEING IN MISRIGGED CONFIGURATION & OUTBD Jul 14, 2007 · N662UA · Boeing 767322 · Trailing Edge Flap Control SystemSDR 2007UALA02626Engine · overtempNR 2 ENGINE EXPERIENCED OVERTEMP DURING CLIMB. [07-27-07] OIL TEMPERATURE IN YELLOW BAND DURING CLIMB. RETURNED TO FIELD IAW FLT MANUAL IRREG PROCEDURE 14.40.17. ORDMM FOUND OIL LEAK AT FUEL OIL COOLER BYPASS VALVE SOLENOID MATING SURFACE. REPLACED SOLJul 14, 2007 · N654UA · Boeing 767322 · Engine (Turbine/Turboprop)SDR 2007UALA02616Blade · fracturedCREW SHUTDOWN THE NR 1 ENGINE DUE TO VIBRATION. LANDED UNDER AMBER ALERT. [08-14-07] ENGINE REPLACED AT IAD. SHOP TEARDOWN FOUND ONE STAGE-2 HPT BLADE FRACTURED AT THE PLATFORM. THIS CAUSED AN UNBALANCE THAT PRODUCED HEAVY VIBRATION. FAILURE RESULT OFJul 13, 2007 · N653UA · Boeing 767322 · Turbine SectionSDR 2007UALA02613Warning Light · illuminatedLEFT GEN DRIVE LIGHT ILLUMINATED WITH ASSOCIATED EICAS L GEN DRIVE DISC MSG. [08-07-07] REPLACED LT IDG AS PER MM 24-11-01, FINAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.Jul 12, 2007 · N651UA · Boeing 767322 · Central WarningSDR 2007UALA02612Hose · damagedRIGHT OVERWING SLIDE CYLINDER LWR INFLATION HOSE IS KINKED AND COLLAPSED. [08-07-07] REPLACED HOSE IAW 20-10-10. SLIDE PROBLEM ROOT CAUSE: SLIDE & INFLATION HOSE ARE IN AN AREA CONTAINING MANY HYDRAULIC LINES & SERVICING ACCESS; SUSPECT HOSE DAMAGED BY SJul 12, 2007 · N649UA · Boeing 767322 · Escape SlideSDR 2007UALA02544Wire · damagedTROUBLESHOOTING FOR EMERGENCY LIGHTS, LIGHTS WILL NOT GO OUT IN ARMED POSITION, ALL LIGHTS ON IN ON. [07-27-07] REPAIRED WIRE WITH A NEW ONE.Jul 11, 2007 · N673UA · Boeing 767322 · Light System WiringSDR 2007UALA02545Battery · inoperativeEXIT LIGHTS INOP BY 2L. SUPPLEMENTAL DATA UPDATE -REPLACED BATTERY AND LIGHTS TURN ON.Jul 10, 2007 · N673UA · Boeing 767322 · Emergency LightingSDR 2007UALA02559Latch · wornRIGHTHAND OVERWING SLIDE COMPARTMENT DOOR NR 3 LATCH WORN. REMOVED & REPLACED LATCH AND KEEPER.Jul 10, 2007 · N649UA · Boeing 767322 · Escape SlideSDR 2007UALA02543Battery Pack · faultyMULTIPLE EXIT LIGHTS OUT BY FWD OVERWING EXIT. REPLACED BATTERY PACKJul 10, 2007 · N673UA · Boeing 767322 · Emergency LightingSDR 2007UALA02533Drain · cloggedRTFL DUE TO AFT LAV TANK INOP LIGHT ILLUMINATED. CREW REPORTED LAVS FULL AND OVERFLOWING. RETURNED TO FIELD DUE TO NO FUNCTIONING LAVS. FOUND DRAINS CLOGGED. UNPLUGGED DRAINS. FOUND 9 CLOTH NAPKINS, 2 RUBBER LAV DOOR SEAL, AND 2 PIECES OF POLYURETHANIC Jul 10, 2007 · N643UA · Boeing 767322 · Waste Disposal SystemSDR 2007UALA02531Fire Detector · faultyFWD CARGO DETECTOR NR 2 AND GROUND PROXIMITY SYS STATUS WILL NOT CLEAR. [08-08-07] RESTARTED SYSTEM. FWD CARGO "DET 2" MSG CLEARED. GROUND PROX SYSTEM MESSAGE STILL PRESENT. RESET GLIDESLOPE DISCRETE PER MM34-46-00 MESSAGE CLEARED. MESSAGE REPEATED 8 DJul 10, 2007 · N642UA · Boeing 767322 · Fire DetectionSDR 2007UALA02523Pump · inoperativeLOST LEFT ENGINE DRIVEN HYD PUMP. [08-08-07] REPLACED LEFT HYD ENG PUMP PER MM 29-11-05. OPS CKS OK. NO LEAKS AFTER SHUTDOWN. AFTER LT HYDRAULIC EDP CHANGE FOUND PUMP LOW PRESSURE LIGHT AND EICAS MSG REPLACED EDP PRESSURE SWITCH. ALSO, REPLACED CONNEJul 10, 2007 · N671UA · Boeing 767322 · Hydraulic Pump (Electric/Engine), MainSDR 2007UALA02552Lamp · damagedEMERGENCY LIGHT STRIP FOUND TORN UP IN LEFT AISLE ADJACENT TO BUSINESS CLASS GALLEY. [07-27-07] REPLACED EEL LAMP ASSY OPS NORMALJul 9, 2007 · N661UA · Boeing 767322 · Emergency LightingSDR 2007UALA02551Battery · faultyEMERGENCY FLASH LIGHT BETWEEN 1L & 1R FLIGHT ATTENDANT SEAT DOES NOT BLINK. [08-08-07] REPLACED BATTERY AND SEAL. AIRCRAFT OK FOR SERVICE.Jul 9, 2007 · N641UA · Boeing 767322 · Emergency EquipmentSDR 2007UALA02497Hose · damagedRIGHT OFF WING ESCAPE SLIDE INFLATION HOSE FROM INFLATION CYLINDER IS CONTAMINATED WITH HYDRAULIC FLUID AND IS DETERIORATED. [08-08-07] HOSE IS DETERIORATED AND WALLS HAVE COLLAPSED FROM LONG TERM CONTACT WITH HYDRAULIC FLUID. REPLACED HOSE ASSY. SLIDE Jul 9, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA02456Hose · contaminatedRIGHT OFF WING ESCAPE SLIDE INFLATION HOSE FROM INFLATION CYLINDER IS CONTAMINATED HYDRAULIC FLUID, AREA OF CONTAMINATION IS ADJACENT TO THE HYD SYSTEM SERVICING SELECTOR. PRESSURIZED HYD SYSTEMS AND NO LEAKS DETECTED. PIPE IS SPONGY AND WALLS HAVE COLLAPSEDJul 8, 2007 · N654UA · Boeing 767322 · Escape SlideSDR 2007UALA02511Lamp · inoperativeLEFT SIDE EXTERNAL EEL LIGHT JUST AFT OF WING IS INOP. [07-27-07] RELAMPED. CHECKS GOOD.Jul 7, 2007 · N662UA · Boeing 767322 · Emergency LightingSDR 2007UALA02510Lamp · inoperativeAFT LEFT & AFT RIGHT DOOR EXTERNAL EEL LIGHTS ARE INOP. [07-27-07] RELAMPED. CHECKS GOOD.Jul 7, 2007 · N662UA · Boeing 767322 · Emergency LightingSDR 2007UALA02509Feeder Cable · unsecureAFT GALLEY LONG EEL STRIP IS INOP. [07-27-07] SECURED FEEDER CABLE. CHECKS GOOD.Jul 7, 2007 · N662UA · Boeing 767322 · Light System Wiring
Back to Boeing 767-322