Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2018022700821Tee Fitting · damagedRT MLG WW FAIL SAFE TEE FITTING HAS ONE HOLE WITH A DEFECT. REMOVED AND REPLACED THE TEE FITTING IAW J/C 5340-01478, REV C, STEP 18 (1-14).SDR CALA2018022300763Fuse · inoperativeEXTERIOR EMERGENCY LIGHT LEFT SIDE OF AIRCRAFT INOPERATIVE. REPLACED THE FUSES IN M738 CHARGER. OPS CHECKED NORMALSDR CALA2018022300765Lamp · inoperativeOVERHEAD EMERGENCY LIGHT AT SEAT ROW 19K INOPERATIVE. REPLACED THE LAMPS. OK FOR SERVICE.SDR CALA2018022300764Lamp · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 4K INOPERATIVE. REPLACED THE LAMPS, OK FOR SERVICE.SDR CALA2018022300759Fuse · inoperativeEXTERIOR EMERGENCY LIGHT AFT OF L2 DOOR INOP. REPLACED FUSES IN M738 CHARGER OPERATIONAL CHECK NORMAL.SDR CALA2018022200752Lens · missingAISLE CEILING PANEL EMERGENCY LIGHT LENS IS MISSING AT 26B. INSTALLED MISSING LENS/BEZEL AS REQUIRED, REF IPC 33-51-04.SDR CALA2018022200750Oven · smokeBLACK SMOKE WAS COMING FROM OVEN 712 3 MINS AFTER IT WAS TURNED ON . TURNED OFF PULLED CB. SMOKE CLEARED. REPLACED OVEN, IAW AMM. ALL OPS NOW OKSDR CALA2018030800860Skin · crackedLEFT EXTERIOR FUSELAGE SKIN CRACKED AT A RIVET, BS 1654.5 JUST BELOW STRINGER 3L. REPAIRED THE SKIN IAW EC/RA 5330-06296.SDR CALA2018022100723Light · inoperativeFLIGHT DECK EMERGENCY EXIT LIGHT, INOPERATIVE. INSTALLED AND TURNED ON EMERGENCY LIGHTS, LIGHT CHECKED GOOD IAW AMM 33-51-00.SDR CALA2018022100722Light · inoperativeEMERGENCY LIGHT ABOVE COCKPIT DOOR INOPERATIVE. REMOVED AND REPLACED LIGHT ASSY TESTS PASSED.SDR CALA2018022000704Relay · faultyINTEGRAL LIGHTING ON THE FUEL PANEL EQUIPMENT COOLING PANEL AND PANEL/ FLOOD FLICKERING ON/OFF. EMERGENCY DECLARED. REPLACED RELAY K755. REF WDM 33-13-16. OPS CK NORMALSDR CALA2018021900687Web · corrodedCABIN FLOOR SUPPORT WEB CORRODED BS 280 TO 286, LBL 44 TO LBL 77. REMOVED AND REPLACED THE WEB IAW SRM 51-10-02, 53-00-51, FIG 101, DETAIL 2, 51-20-01, 51-40-02, AND GMM 07-35-05, PG 3.SDR CALA2018021600646Socket · damagedEMERGENCY LIGHT NEAR SEAT 1K FOUND DAMAGED. REMOVED AND REPLACED THE SOCKET ASSY AND INSTALLED NEW LENS.SDR CALA2018021600645Light · inoperativeCROSS AISLE FLOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LIGHT ASSY. OPS CHECKED NORMAL. OK FOR SERVICE.SDR CALA2018021600644Lens · missingLENS MISSING FOR THE CEILING EMERGENCY LIGHT AT 29B. REPLACED THE LENS.SDR CALA2018021600616Outflow Valve · faultyCLIMBING THRU 10K FT, SUDDEN DRAMATIC CHANGE IN NOISE LEVEL, VERY LOUD WIND SOUND WITH LANDING GEAR MONITOR. AIRCRAFT DID NOT PRESSURIZE NORMALLY. EMERGENCY DECLARED. REPLACED CABIN PRESSURE PANEL ASSY IAW AMM 21-31-01. REPLACED THE OUTFLOW VALVE IAW AMMSDR CALA2018021600641Frame · crackedBS 1809, BULKHEAD LT FOUND CRACKED. REPAIRED IAW EA 5300-01600, REV A, OP 002.SDR CALA2018021600640Skin · crackedBS 1809, STRINGER 12A, SKIN CRACKED. REPAIRED IAW EA 5300-01600, REV A, OP 002, FIG 4.SDR CALA2018021600639Stringer · crackedBS 1809, STRINGER 12A, FOUND CRACKED REPAIRED IAW EA 5300-01600, REV A, OP 002SDR CALA2018021600633Skin · crackedNR 2 PYLON, LT ACCESS DOOR 446BL FWD UPPER CORNER CUTOUT FOUND CRACKED. THE SKIN WAS REPAIRED IAW ECRA 5430-02146, REV- .SDR CALA2018021600632Failsafe · crackedBS 955 RT FAILSAFE STRAP FOUND CRACKED. THE FAILSAFE WAS REPAIRED IAW EA 5340-01478, REV C, OP 04.SDR CALA2018021600631Tee Fitting · crackedBS 955 COMMON TO THE FAILSAFE STRAP AND THE TEE FITTING WAS CRACKED, THE TEE FITTING WAS REPLACED IAW EA 5340-01478 REV.C OP.04SDR CALA2018021200606Fitting · corrodedFOUND CORROSION ON THE CASTING FITTING AT MAIN CABIN FWD WET AREA LBL 54, BETWEEN BS 266 AND 287. CORROSION REMOVED FROM CASTING AND FOUND OUT OF LIMITS IAW SRM 51-10-02, AND 53-00-51, FIG.101, DETAIL II. REMOVED AND REPLACED THE CASTING FITTING IAW SRM 51-SDR CALA2018021200604Module · faultyGEAR DISAGREE LIGHT AND ASSOCIATED EICAS WITH TAILSKID LIGHT, AND EICAS ON FINAL. EMERGENCY DECLARED. FOUND MESSAGE WOULD CLEAR WITH SLIGHT MOVEMENT OF GEAR HANDLE. R & R THE LANDING GEAR CONTROL LEVER MODULE IAW AMM32-31-01. ALL TESTS PASSED.SDR CALA2018021100595Light · missing34F EMERGENCY PATH LIGHT MISSING. REPLACED 34F EMERGENCY PATH LIGHT OPS CHECKS GOOD.SDR CALA2018021100596Light · damagedEMER ESCAPE PATH MARKING LIGHT AT 33F AND 32F IS PUSHED IN. REPLACED EMER ESCAPE PATH MARKING LIGHT AT 33F AND 32F OPS CHECKS GOOD.SDR CALA2018021000577Floor Support · crackedBS 245 - 266, RBL 60 THE FLOOR SUPPORT WAS FOUND CRACKED. THE FLOOR SUPPORT WAS REPAIRED IAW ECRA 5310-07350 REV -.SDR CALA2018020900546Battery · inoperativeEXTERIOR EMERGENCY EXIT LIGHT AT THE L1 DOOR WAS INOPERATIVE. REPLACED THE BATTERY AND POWER SUPPLY IAW 33-51-07-002-014-002SDR CALA2018020900536Altimeter · reads highSTANDBY ALTIMETER READS PLUS 600 FEET AT ALTITUDE. REMOVED AND REPLACED THE STANDBY ALTIMETER IAW AMM 34-13-06-344-031. OPS CHECKED SATISFACTORY. NO DEFECTS NOTED. OK TO CONTINUE.SDR CALA2018020900549Switch · missingFA JUMPSEAT, MISSING THE EVACUATION SWITCH. R & R THE EVACUATION CONTROL PANEL IAW AMM 25-63-00, TESTED GOOD.SDR CALA2018020900548Clevis · damagedRIGHT OVERWING ESCAPE SLIDE COMPARTMENT DOOR, FWD LATCH CONTROL ROD, FWD CLEVIS IS BENT AND RUSTED. REPLACED THE CLEVIS.SDR CALA2018020900547Lamp · inoperativeINTERIOR OVERHEAD EMERGENCY LIGHTS AT SEATS 35J, 6B, AND 6J ARE INOPERATIVE. REPLACED THE LAMPS, OPS CHECKED NORMAL.SDR CALA2018020900495Light · not seatedFLIGHT DECK EMERGENCY LIGHT INOPERATIVE. RESEATED THE LIGHT ASSY, OPS TEST PASSED IAW AMM 33-51-00.SDR CALA2018020500484Controller · faultyFA'S COMPLAINED OF LIGHT HEADED AND NAUSEA, ESP IN BUSINESS CLASS AND 1ST CLASS, ELT LACK OF AIRFLOW AND STRUGGLED WITH BALANCE ISSUES AND FELT THEY WERE IN A CONSTANT TURN, SEVERAL PAX COMPLAINED AS WELL. NO FUMES OR SMOKE WAS NOTED, PRESSURIZATION WAS ROUGH SDR CALA2018012900391Flag · out of adjustDOOR 1R YELLOW ARMED FLAG DID NOT POP UP WHEN DOOR WAS ARMED. ADJUSTED ORIENTATION OF SLIDE FLAG AS REQUIRED. FLAG SHOWS WHEN ARMED. OKAY FOR SERVICE.SDR CALA2018012800368Indicator · reads highAT FL360 STANDBY ALTIMETER WAS 500 FEET HIGH AT 36500 FEET. FOUND VIBRATOR INOP. REPLACED STBY ALT INDICATOR. OPS CHECKS GOOD. REF AMM 34-13-06.SDR CALA2018012600325Strap · brokenR2 DOOR ESCAPE SLIDE GIRT BAR FWD HOLDING STRAP BROKEN. REMOVED AND REPLACED IAW 25-66-01-004-001.SDR CALA2018012600310Skin · crackedA CRACK WS FOUND ON LOWER LT WING SKIN AT WS 990.2. REPAIRED THE SKIN IAW EA 5720-02611, REV B.SDR CALA2018012600309Skin · crackedA CRACK WAS FOUND ON THE LOWER RT WING SKIN WS 990.2. REPAIRED CRACK ON LOWER SKIN WS 990.2 FASTENER HOLE 1 ON RIGHT WING IAW EA 5720-02611 REV B.SDR CALA2018012600306Floorbeam · corrodedBS 324, RBL 16 - 64 FLOORBEAM FOUND CORRODED. THE FLOORBEAM WAS REPAIRED IAW SRM 53-0051, REPAIR 1, FIG 201.SDR CALA2018012600304Floor Support · corrodedB767-20-3-6043 FWD CGO STA 520 LWR OF 5R PDU RH AFT MOUNT BOLT BELOW AREA CORROSION CRACKED FORWARD CARGO STA 520 LOWER OF 5R PDU RH AFT MOUNT BOLT BELOW IN TERCOSTAL REPLACED PER SRM 51-10-02 AND INSTALLED PER SRM
51-40-02.SDR CALA2018012600305Floorbeam · corrodedBS 287, RBL 23 FLOORBEAM FOUND CORRODED. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIG 201.SDR CALA2018012200286Flap System · malfunctionedTE FLAP DISAGREE, FLAP WOULD NOT EXTEND BEYOUND FLAPS 5. EMERGENCY DECLARED. FIM 27-51-00-815-810 COMPLIED WITH. SYSTEM OK. DURING FLAP OPERATION NOTED THE C HYD ADP INOPERATIVE. OPERATED ADP TEST & RESET SWITCH IAW AMM 29-11-00-865-459. ADP OPS CHECKESDR CALA2018012200283Unknown · odorSULFUR ODOR COMING FROM AREA NEAR L2 AND R2 DOORS. INSPECTION PERFORMED NEAR TO DOORS 2L AND 2R NOTHING NOTED AND THE INBOUND CREW CONFIRM THAT 15 MINUTES AFTER TAKE OFF THE ODOR WAS NO LONGER PRESENTSDR CALA2018011900232Latch · failedLEFT OVERWING ESCAPE SLIDE DOOR LATCH AND DISCONNECT, TORQUE CHECK FAILED IAW EA2560-02662, OPS 1. ACCOMPLISHED TORQUE CHECK IAW EA 2560-02662-OPS1.SDR CALA2018011900231Connector · damagedEMERGENCY LIGHTS AT ROWS 34D AND 34F INOPERATIVE. REPAIRED THE CONNECTOR. R & R THE FUSE AT POWER SUPPLY M9047, AND REPLACED THE LIGHT ASSY AT SEAT 34D IAW WDM 33-51-15. OPS CHECKED GOOD.SDR CALA2018011900230Battery Pack · inoperativeL1 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED THE BATTERY PACK . OP CHECKED NORMAL IAW AMM 33-51-07.SDR CALA2018011900221Support Beam · crackedFWD CARGO DOOR FRAME LOWER BEAM FOUND CRACKED AT RBL48, BS 500 & 566. A NEW SUPPORT BEAM WAS REINSTALLED IAW SRM 51-10-02 AND AMM 20-11-00.SDR CALA2018011200152Lens · missingEMERGENCY EXIT LIGHT LENS IS MISSING FROM CEILING PANEL AT 21B. REPLACED THE LENS.SDR CALA2018011200128Floorbeam · corrodedBS 1518, BL 0 TO LBL 29 FLOORBEAM FOUND CORRODED. THE FLOORBEAM UPPER TEE WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIG 201.