SDR HALA0700349Battery · weakETOPS SIGNIFICANT SYSTEM, UNABLE TO START APU. EICAS MESSAGE APU FAULT. FOUND MINI FLAG 34 DURING BITE OF APU CONTROL UNIT, REPLACED APU BATT PER M/M. APU STARTED SEVERAL TIMES SATISFACTORLY. BITE PROCEDURE 49-11-00 FIG 103 M/M24-31-04. NO FAULTS PRESENTSDR HALA0700346Lamp · inoperativeRT SIDE OVERWING EMERGENCY LIGHT INOP. RELAMPED. OPS CKS NORMALSDR HALA0700344Power Cable · damagedEMERGENCY LIGHTS AT 17-22AB AND MID LAV INOP. REMOVED AND REPLACED 2 EA EMERGENCY POWER CABLE PER HAL MM 33-51-00-032-001 HA MM 33-51-00-032-002. EMERGENCY LIGHTS TEST PER HA MM 33-51-00-715-001. EMERGENCY LIGHTS OPERATE NORMALLY.SDR HALA0700345Engine · oil consumptionETOPS SIGNIFICANT SYSTEM, APU FAULT DID NOT START AFTER LANDING DUE TO OIL QTY 0. ADDED 3 PINTS OF OIL. NO LEAKS NOTED. FOUND "NO LIGHT OFF" FAULT ON ECU. REPLACED IGNITER PLUG PER FIM 49-11-00 AND M/M 74-21-2. OPS CK LEAK CK GOOD.SDR HALA0700338Coupler · inoperativeETOPS SIGNIFICANT SYSTEM, NR 2 HF INOP. REMOVED AND REPLACED NR 2HF COUPLER GND CHK OK PER 23-11-01.SDR HALA0700333Lamp · inoperativeOVERHEAD AISLE EMERGENCY LIGHT ADJACENT TO 39 B INOP. RELAMPED PER AMM 33 51 05, OPS NML. OK FOR SERVICE.SDR HALA0700330A/C Pack · malfunctionedETOPS SIGNIFICANT SYSTEM, EICAS MTC MSG 'LT PACK BITE'. PERFORMED BITE ON LT PACK, LOW LIMIT VALVE FAULT LIGHT. VERIFIED OK, CLEARED MSG.SDR HALA0700326Brake Assy · smokeINFO TO MAINTENANCE ATC GROUND ADVISED SOME SMOKE COMING FROM RT LDG GEAR (BRAKE AND TIRES JUST CHANGED). REMOVED AND REPLACED NR 7 BRAKE PER M/M 32-41-08 AND REINSTALLED TIRE PER M/M/ 32-45-01.SDR HALA0700324Connector · damagedETOPS SIGNIFICANT SYSTEM, EICAS MESSAGE"L ENG FIRE LP 1". ACCOMPLISHED FIM 26-11-00. REMOVED AND REPLACED LOWER FWD FIRE LOOP, COND SAME. FOUND CONNECTOR AT AFT LOWER LOOP BAD. INSTALLED NEW LUG. OPS/TEST OK (REF WDM 26-11-11).SDR HALA0700315Engine · flamed outETOPS SIGNIFICANT SYSTEM, BTB, NR 1 ENGINE FLAMED OUT AFTER INITIAL START. PERFORMED FIM 73-21-00, C/W PIMU BITE PROCEDURE, NO CURRENT FAULTS FOUND, NO MTC OR EICAS MSGS. ACCOMPLISHED AMM TASK 28-22-11-404-008, STEP H. OPS TEST NR 1 ENG FUEL S/OFF ACT. NO SDR HALA0700313None · noneETOPS SIGNIFICANT SYSTEM, FOUND 'LEFT ENG FIRE LOOP NR 1' EICAS MSG DURING OVERNIGHT CHECK. PERFORMED TEST, MSG CLEARED PER FIM 26-11-00 FIG-105.SDR HALA0700306Control Panel · malfunctionedETOPS SIGNIFICANT SYSTEM, PREFLIGHT, COPILOTS RADAR ALT DH REF INDICATOR WILL NOT RESET. REPLACED F/O'S EFIS CONTROL PNL. GND OPS CHK OK IAW 34-22-02. NO FAULTS NOTED. A/C OK TO REMAIN AT LAND 3 STATUS.SDR HALA0700304Circuit Card · malfunctionedETOPS SIGNIFICANT SYSTEM, DURING ETOPS 1 CHECK FOUND L ENG FIRE LP 1 EICAS MESSAGE ILLUMINATED. REPLACED LT ENG FIRE DET CARD (M681), OPS CHECK OK IAW AMM 26-12-000.SDR HALA0700305Transceiver · inoperativeETOPS SIGNIFICANT SYSTEM, NR 2 HF INOP. NO TRANSMIT, RECEIVE, SIDETONE, DATALINK. REMOVED AND REPLACED NR 2 HF XCVR. GND CHK OK PER AMM 23-11-03.SDR HALA0700298Starter · malfunctionedETOPS SIGNIFICANT SYSTEM - BTB - WHILE STARTING LT ENG N2 REACHED 23 PERCENT AND THEN DECREASED TO 0. REMOVED AND REPLACED NR 1 STARTER IAW 80-11-01 AND SERVICED, DRIED MOTORED ENG IAW AMM-71-00-00-201, ALL OK.SDR HALA0700301Connector · looseETOPS SIGNIFICANT SYSTEM, EICAS STATUS MESSAGE " LEFT FIRE LP2 " DISPLAYED. FOUND LOOSE CONNECTOR ON LOWER AFT DETECTOR ASSY. CONNECTOR NR TS 682B/2. PER FIM 26-11-00 SYSTEM TEST NORMAL.SDR HALA0700299Display · malfunctionedETOPS SIGNIFICANT SYSTEM, L. RADAR SYS WILL NOT DISPLAY ON EITHER HSI. SWITCHED TO R RADAR SYS DISPLAY APPEARS NORMAL. RESET LEFT WX RADAR SYS C/B OPS CHK OK PER MM 34-43-00.SDR HALA0700300Radar · failedETOPS SIGNIFICANT SYSTEM, RIGHT WEATHER RADAR FAIL. TROUBLESHOOT SYS PER FIM 34-41-00 ALL SETTINGS NORMAL, SYSTEM OK FOR SERVICE.SDR HALA0700296Housing · crackedETOPS SIGNIFICANT SYSTEM, NR 2 STARTER GEAR BOX HOUSING ASSEMBLY CRACKED. REPLACED NR 2 HOUSING ASSY. LEAK CHECK OK.SDR HALA0700293Starter · failedETOPS SIGNIFICANT SYSTEM - BTB - RETURNED TO GATE, ON STARTING ENGINE NR 2 GND PERSONAL REPORT SPARKS FROM RT ENG PRIOR TO FUEL INTRO START TERMINATED, STARTER CUTOFF LIGHT AND RT ENG VALVE LIGHT REMAINED ON. RIGHT ENGINE REPLACED STARTER PER AMM 80-11-01. LSDR HALA0700290Connector · unsecureEMERGENCY ESCAPE PATH LIGHTS INOP LT SIDE ROWS 31-38 ON OVERNIGHT CHECK. RESECURED STRIP CONNECTOR, SYSTEM NOW CHECKS NORMAL PER B767 AMM 33-51-10-402.SDR HALA0700287Fire Detector · malfunctionedETOPS SIGNIFICANT SYSTEM, EICAS STATUS MESSAGES "LEFT FIRE LP1" AND L ENG FIRE LP2". REMOVED, CLEANED, AND REINSTALLED PYLON CONNECTORS J1, J2, J3, J4, AND J5. PER FIM REPLACED LOWER AFT DETECTOR ASSY PER AMM 26-11-02. LEFT ENGINE FIRE DETECTION SYSTEM NOWSDR HALA0700288Unknown · unknownETOPS SIGNIFICANT SYSTEM, APU AUTO SHUT DOWN AT GATE. PERFORMED ECU BITE PER FIM 40-11-00-1. NO FAULTS NOTED. RESTARTED APU, OPS CK NORMAL WITH NO FAULTS. OK FOR SERVICE.SDR HALA0700289Unknown · unknownETOPS SIGNIFICANT SYSTEM, PNEUMATIC PRESSURE DRIPS EXCESSIVELY WHEN USING APU AIR FOR ENGINE STARTS. OPS CHECKED APU BLEED AIR PEC AMM 49-11-00-802, OPS CHECKED GOOD ALSO CHECKED FIM 36-10-00 FIG 118. NO FAULTS NOTED.SDR HALA0700286Fitting · leakingETOPS SIGNIFICANT SYSTEM, R GEN DRIVE LIGHT CAME ON APPROACH, TURNED ON APU. PERFOMED BPCU BITE PER FIM 24-20-00. ALL ELECTRICAL SYSTEMS CHECK GOOD. NO FAULTS. FOUND IDG OVERFLOW SERVICE FITTING LEAKING. REPLACED SERVICE AND OVERFLOW SERVICE ADAPTERS PER SDR HALA0700284Idg · inoperativeETOPS SIGNIFICANT SYSTEM, RIGHT IDG OUT AND RISE TEMPERATURES VARY RAPIDLY AND ERRATICALLY FROM 0 TO 140. SERVICED RT IDG TO PROPER LEVEL. NO MSG ON BPCU. RAN ENG, OPS NML PER FIM 24-20-00.SDR HALA0700283Pump · inoperativeETOPS SIGNIFICANT SYSTEM, RIGHT ELEC DEMAND PUMP INOP. ACCOMPLISHED FIM 29-11-00 FIG 104A, OPS CHECK NORMAL NOW.SDR HALA0700285Unknown · unknownETOPS SIGNIFICANT SYSTEM, REQUIRES 2 UNITS LT YOKE DISPLACEMENT FOR WINGS LVL.//INFO NOTED WITHIN LIMITS PER AMM27-01-00. OK FOR SERVICE.SDR HALA0700279Compressor · overheatedF/A REPORTED SMELLING AN ELECTRICAL ODOR IN THE AFT RIGHT CABIN LAST 5 ROWS ON THE RIGHT SIDE, ALL GALLEY EQUIPMENT WAS OFF. INSP CABIN AREA AROUND SEATS 39-43 H/J INCLUDING UNDER SEATS, OVERHEAD BINS, AFT GALLEY AND AFT LAVS CHECKED FWD, AFT AND BULK CARGO CSDR HALA0700280Slide · unwanted deployLT OVERWING SLIDE DEPLOYED DURING RT OVERWING SLIDE REPLACEMENT. REMOVED AND REPLACED LEFT OVERWING SLIDE ASSY PER AMM 25-65-01 AND 767-3-195002.SDR HALA0700276Relay · malfunctionedETOPS SIGNIFICANT SYSTEM, EICAS MSG "C HYD SYS MAINT" DISPLAYED HYD PRESS NORMAL. REPLACED HYD GEN ADP CMD RELAY K865 & SYS 1 AIR/GROUND RELAY K1788 PERFORMED OPERATIONAL TEST PER M/M 29-11-00-715-896. OPS CKS NORMAL.SDR HALA0700275Relief Valve · leakingETOPS SIGNIFICANT SYSTEM, C HYD FLUID QUANTITY DECREASED TO .47. FOUND PACKING ON PRESSURE RELIEF VALVE OF ADP FILTER MODULE LEAKING. REPLACED PACKING ON RELIEF VALVE PER TASK 29-11-19-004-001. LEAK CK'S OK. SERVICED CENTER HYD SYSTEM TO FULL.SDR HALA0700272Oil System · fluctuatesETOPS SIGNIFICANT SYSTEM, APU OIL QTY FLUCTUATES BETWEEN .50 AND FULL. SHUT DOWN APU AND CHECKED OIL LEVEL. ADDED 1/2 PINT OIL. STARTED APU NO OIL LEAKS NOTED. EICAS READS FULL. OK FOR SERVICE.SDR HALA0700270Unknown · unknownETOPS SIGNIFICANT SYSTEM, ON CLIMB-OUT RT I/B AILERON APPEARED ON STATUS PAGE TO BE IN EXTENDED UP POSITION THIS CAUSED LEFT RUDDER TRIM USE OF 4 UNITS. IN CRUISE LOOK AT BOTH I/B AIL BOTH APPEARED TO BE BELOW NORMAL WHILE STATUS PG DEPICTED THEM ABOVE NORMALSDR HALA0700271Unknown · unknownETOPS SIGNIFICANT SYSTEM, AIRCRAFT REQUIRES 4 UNITS OF LEFT RUDDER TRIM TO KEEP THE AILERON TRIM INDICATOR AT ZERO ONLY DURING CLIMB AND DESCENT. AT CRUISE, ALL TRIM SETTINGS ARE NORMAL. T/S PER FIM 27-21-00. OPERATED RUDDER TRIM FULL LT AND RT. RUDDER TRISDR HALA0700262Pitot System · malfunctionedETOPS SIGNIFICANT SYSTEM - BTB: FO'S PITOT HEAT EICAS MESSAGE AFTER ENGINE START. T/S PER FIM 30-31-01-05 IDENTIFIED F/OS PITOT STATIC PROB B28 INOP. REMOVED AND REPLACED PER AMM 34-11-01. PERFORMED PITOT STATIC PROBE TEST PER AMM TASK 34-11-01-725-001. LKSDR HALA0700261Unknown · unknownETOPS SIGNIFICANT SYSTEM, RUDDER RATIO EICAS OVERHEAD PANEL ILLUM. RUDDER RATIO SYS CHECKS GOOD PER FIM 27 21 00 FIG 104 MSG CLEARED DID NOT RETURN.SDR HALA0700260Wire · shortedETOPS SIGNIFICANT SYSTEM, R ENG SHUTDOWN DID NOT DISPLAY AND AURAL WARNING AND APPROPRIATE ENGINE RELATED MESSAGES WERE NOT INHIBITED WITH ENG SHUTDOWN. REMOVED AND REPLACED RT ENGINE FUEL METERING UNIT PER AMM 73-21-01, CONDITION SAME FOUND CONNECTOR WIRES SSDR HALA0700259Starter · malfunctionedETOPS SIGNIFICANT SYSTEM, APU ON START UP SHOWED APU FAULT AND SHUT DOWN AUTOMATICALLY EICAS MSG APU FAULT. BITE CK ECD "START ABORTED" FAULT. FOUND STARTER BRUSH IND LOW/BATT VOLTAGE LOW W/LOAD. REMOVED AND REPLACED APU BATT PER MM 24-31-04. REMOVED AND RSDR HALA07431Seat Track · corrodedLEVEL 1 CORROSION AT SEAT TRACK RBL 59 AT STA. 69, AREA REWORKED AND FOUND WITHIN LIMITS PER SRM 53-00-52. REWORKED AREA ALODINED AND PAINTED.SDR HALA0700254Warning System · malfunctionedETOPS SIGNIFICANT SYSTEM, L ENG CONTROL ILLUMINATED AFTER START EICAS WARNING. BIT L PIMU PER FIM NO FAULTS RAN ENG OPERATION NML 73 2100. OK FOR SERVICE.SDR HALA0700244Controller · malfunctionedETOPS SIGNIFICANT SYSTEM, L FWD WINDOW HEAT INOP "L FWD WINDOW" EICAS MSG DISPLAYED. REPLACED WINDOW HEAT CONTROLLER PER AMM 30-41-01, OPS CHECK GOOD.SDR HALA0700234Control System · malfunctionedETOPS SIGNIFICANT SYSTEM, AILERON TRIM UNITS TO THE LEFT DURING TAKEOFF,CLIMB AND APPROACH. OK DURING CRUSE SEGMENT. PERFORMED OPERATIONAL TEST AILERON AND AILERON TRIM, TRIM CONTROL SYSTEM PER AMM 27-11-00-715-002. OPERATION NORMAL.SDR HALA0700231Unknown · unknownETOPS SIGNIFICANT SYSTEM, TOTAL FUEL DIFFERS FORM CAPT AND F/O FMC(S) CALCULATED FUEL QTY. FUEL QTY ERROR PAGE 2/2 ALERT MSG DISPLAYED. FUEL FLOW WAS NORMAL TOTAL FUEL 24.8 FMC CALCULATED FUEL 22.3. NO EVIDENCE OF FUEL LEAK. PERFORMED T/S PER FIM 34-61-00 SDR HALA0700220Iru · unknownETOPS SIGNIFICANT SYSTEM, C IRS FAULT LIGHT ON EICAS AND IRS PANEL. REPLACED C IRU. OPS CHECK OK PER MM 34-21-01. PERFORMED MCDP TEST NR 30 PASSED. A/C LMP STATUS REMAINS IN "LAND 3".SDR HALA0700210Ecu · malfunctionedETOPS SIGNIFICANT SYSTEM, APU WOULD NOT START AFTER 2 ATTEMPTS. REMOVED AND REPLACED ECU AND RESEATED CONNECTOR AT APU COMPARTMENT. OPS CHECK GOOD, WORK DONE IAW AMM 49-61-05.SDR HALA0700211Light · inoperativeFLOOR PATH FROM SEAT 16 THRU 20 EMERGENCY, LIGHTS INOP, LEFT SIDE. REMOVED AND REPLACED EMERGENCY LIGHTS. FLOOR PATH FROM SEAT 16 THRU 20 PER 33-51-3. OPS CHECK NORMAL, OK FOR SERVICE, LEFT SIDE.SDR HALA0700208Relay · malfunctionedETOPS SIGNIFICANT SYSTEM, R IDG VALVE STATUS MSG. TROUBLESHOT SYSTEM PER FIM 24-20-00 FIG 101 BLOCK 1, ALL TESTS CHECK GOOD. REPLACED K1032 RELAY, OPS CHECKS NORMAL.SDR HALA0700176A/C Pack · unknownETOPS SIGNIFICANT SYSTEM, L PACK HIGH EICAS AND LT PACK AUTO SHUTDOWN ON FINAL. PERFORMED PTC BITE PROCEDURES PER FIM 21-51-00; SYS CHECK OK. LEFT AC PACK OPS CHECK OK, NO ALERTS/MSGS NOTED. OK FOR SVC.SDR HALA0700174Switch · stuckETOPS SIGNIFICANT SYSTEM, RIGHT PACK TEMP, ICAS MSG RIGHT PACK RESET SWITCH IS STUCK IN THE IN (PRESSED) POSITION. RESET RT PACK RESET SWITCH. CHECK OK.
Back to Boeing 767-33A