Boeing 767-34AF
Service difficulty reports · 6,321
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09656977Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH & GOUGE AT STA 1380 TO 1480 RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656976Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 833 TO 930, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656975Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 731 TO 833, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656972Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 930 TO 975, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656971Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1114 TO 1197+22 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656970Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1480 TO 1598, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656969Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1207 TO 1320, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656968Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 873 TO 932, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656966Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 975 TO 1114, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656965Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1320 TO 1380 RBL 11 TO RBL 33. FLOOR PNL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656963Attach Fitting · crackedINSPECTION TYPE:C AFT CARGO STA 1085 RBL 25 BELOW FLOOR SUPPORT BEAM ATT CLIP CRACK. CRACK LENGTH 0.875 INCH. AFT CARGO COMPT STA 1085 RBL 25 BELOW FLOOR SUPPORT BEAM ATT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656962Attach Fitting · crackedINSPECTION TYPE:C AFT CARGO STA 1085 LBL 25 BELOW FLOOR SUPPORT BEAM ATT CLIP FOUND CRACK. CRACK LENGTH 1 INCH. AFT CARGO STA 1085 LBL 25 BELOW FLOOR SUPPORT BEAM ATT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656961Hinge Fitting · crackedINSPECTION TYPE:C RT WING I/B AFT FLAP HINGE FITTING FOUND CRACK. CRACK LENGTH I/B FLANGE 1.2 INCH, O/B FLANGE 1.5 INCH. RT WING I/B AFT FLAP HINGE FITTING REPAIRED AS PER SRM 57-53-02-2R1 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATERSDR IPXA09656925Floor Panel · damagedINSPECTION TYPE:N/A POS 3R FLOOR PANEL DAMAGED. REPAIRED PER EO B767-5320-34455-A.SDR IPXA09656911Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL 9C DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA09657021Stiffener · crackedINSPECTION TYPE:C MAIN EQUIPMENT CTR STA 246 FLOORBEAM STIFFENER AT LBL 25 FOUND CRACKED. CRACK LENGTH 0.5 INCH. MAIN EQUIPMENT CTR STA 246 FLOORBEAM STIFFENER AT LBL 25 REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09657020Stiffener · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOORBEAM STIFFENER AT RBL 25 FOUND CRACK. CRACK LENGTH 0.75 INCH. MAIN EQUIPMENT CENTER STA 246 FLOORBEAM STIFFENER AT RBL 25 REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656964Stiffener · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOOR BEAM STIFFENER AT LBL 50 FOUND CRACKED. CRACK LENGTH 0.75. MAIN EQUIPMENT CENTER STA 246 FLOORBEAM STIFFENER AT LBL 50 REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656958Stiffener · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOORBEAM STIFFENER AT RBL 10 FOUND CRACK. CRACK LENGTH 2 INCHES. MAIN EQUIPMENT CENTER STA 246 FLOORBEAM STIFFENER AT RBL 10 REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656985Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 975 TO 1114, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656984Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1197+22 TO 1207 RBL 55 TO RBL 77. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656967Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 654+22 TO 690, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656876Fairing · delaminatedINSPECTION TYPE:C LT WING I/B MAIN FLAP O/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-03 PAR 5A (1) FIG 5 REV 44. THIS CLASSIFIED AS MAJOR REPAIR WITH REPAIR MATERIAL RESIN EY3804PT AND GLASSFIBER BMS9-3TYH3CSDR IPXA09656877Skin · dentedINSPECTION TYPE:C CUSTOMER REQUEST - CARRY OUT PERMANENT REPAIR AT FUSELAGE SKIN DENT AREA AT BS 1418 STR 29L-30L AREA. FASTENERS REMOVED & REINSTALLED WITHIN A 2 INCH PERIPHERY OF THE DENT AREA PER HX RS R53-61-36381 REV A, NO DAMAGES OR CRACK WERE FOUND AFTSDR IPXA09656858Fairing · delaminatedINSPECTION TYPE:C RT WING I/B MAIN FLAP O/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-03 PAR 5A (1) FIG 5 REV 44. THIS REPAIR CLASSIFIED AS MAJOR REPAIR WITH MATERIAL RESIN EY3804PT AND GLASS FIBER BMS 9-3TYHSDR IPXA09656817Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540 RBL 11 TO RBL 33 FOUND GOUGE & DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656816Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 283 TO 412, RBL 11 TO RBL 33 FOUND SCORE AND DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656815Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 731 TO 833 LBL 11 TO LBL 33 FOUND SCORE & DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656813Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 833 TO 930 LBL 55 TO LBL 77 FOUND GOUGE AND DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656863Support Frame · crackedINSPECTION TYPE:C RT WING - I/B AILERON I/B HINGE SUPPORT FRAME AFT UPPER FLANGE FOUND CRACKED, CRACK LENGTH 1 INCH. RT WING I/B AILERON I/B HINGE SUPPORT FRAME AFT UPPER FLANGE REPAIRED AS PER HX RS R57-55-36384 REV A. THIS REPAIR IS CLASSIFIED AS MAJOR REPSDR IPXA09656862Wedge · misrepairedINSPECTION TYPE:C LT WING O/B TRAILING EDGE FLAP TRAILING EDGE WEDGE LOWER SURFACE I/B AREA THE EXISTING REPAIR PATCH NON-STANDARD REPAIR. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-07 PAR 5G FIG 14 REV 44. THIS IS CLASSIFIED AS MAJOR REPAIR WITHSDR IPXA09656859Wedge · misrepairedINSPECTION TYPE:C LT WING O/B TRAILING EDGE FLAP T/E WEDGE LOWER SURFACE I/B AREA THE EXISTING REPAIR PATCH NON-STANDARD REPAIR. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-07 PAR 5G FIG 14 REV 44. THIS REPAIR CLASSIFIED AS MAJOR REPAIR WITH MATERSDR IPXA09656856Attach Fitting · crackedINSPECTION TYPE:C LT WING L/E LES 622 FRONT SPAR ATT CLIP FOUND CRACKED, CRACK LENGTH 1.125 INCH. LT WING L/E LES 622 FRONT SPAR ATT CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656854Wedge · misrepairedINSPECTION TYPE:N/A LT WING O/B TRAILING EDGE FLAP TRAILING EDGE WEDGE LOWER SURFACE I/B AREA THE EXISTING REPAIR PATCH NON-STANDARD REPAIR. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-07 PAR 5G FIG 14 REV 44. THIS REPAIR IS CLASSIFIED AS MAJOR RESDR IPXA09656716Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL POS 7 CTR DAMAGED. REPAIRED PER EO B767-5320-34305-A.SDR IPXA09656715Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL POS 10 CTR DAMAGED. REPAIRED PER EO B767-5320-34306-A.SDR IPXA09656713Floor Panel · damagedINSPECTION TYPE:N/A MCD POS 4 CTR FLOOR PANEL DAMAGED. REPAIRED PER EO B767-5320-34304-A.SDR IPXA09656789Fitting · crackedINSPECTION TYPE:C LT WING I/B MAIN FLAP DRIVE ARM UPPER FITTING LWR FLANGE CRACKED, CRACK AT BOTH I/B & O/B FLANGE. LT WING I/B MAIN FLAP DRIVE ARM UPPER FITTING REPAIRED AS PER SRM 57-53-02-2R1 FIG 201 REV 44, THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MSDR IPXA09656860Skin · crackedINSPECTION TYPE:C LT WING NR 4 SLAT I/B NOSE SKIN FASTENER HOLE AREA FOUND CRACKED, CRACK LENGTH 0.125 INCH. LT WING NR 4 SLAT OSS573 NOSE SKIN REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 7075-T6-0.0SDR IPXA09656857Skin · crackedINSPECTION TYPE:C RT WING NR 9 SLAT O/B NOSE SKIN FASTENER HOLE AREA FOUND CRACKED, CRACK LENGTH 0.125 INCH. RT WING NR 9 SLAT AT OSS 641.62 NOSE SKIN REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 7075-SDR IPXA09656855Skin · crackedINSPECTION TYPE:N/A LT WING NR 4 SLAT O/B NOSE SKIN FASTENER HOLE AREA FOUND CRACKED, CRACK LENGTH 0.125 INCH. LT WING NR 4 SLAT OSS 641.55 NOSE SKIN REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 7075-TSDR IPXA09656853Skin · crackedINSPECTION TYPE:C LT WING NR 3 SLAT I/B AREA NOSE SKIN FASTENER HOLE AREA FOUND CRACKED, CRACK LENGTH 0.125 INCH. LT WING NR 3 SLAT AT OSS 724.49 NOSE SKIN REPAIRED AS PER SRM 57-43-01-2R2 FIG 201 REV 44. THIS REPAIR CLASSIFIED AS MAJOR REPAIR WITH MATERIAL SDR IPXA09656819Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 246 TO 412 RBL 55 TO RBL 77 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656818Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 690 TO 731, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656814Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540 RBL 33 TO RBL 55 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656812Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 936 TO 985 RBL 77 TO RBL 88 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656811Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656810Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 833 TO 930, LBL 11 TO LBL 33 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656809Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1460 TO 1540 LBL 55 TO LBL 77 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656808Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 975 TO 1114, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.
Back to Boeing 767-34AF