SDR IPXA09656807Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540, RBL 55 TO RBL 77 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656806Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1207 TO 1350, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656805Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 540 TO 654+22, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656804Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 833 TO 930 LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656803Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1480 TO 1598 RBL 33 TO RBL 55 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656802Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 985 TO 1087 LBL 75 TO LBL 88 FOUND POOR CONDITION. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656801Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 654+22 TO 690 LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656800Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1480 TO 1598, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656799Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1197 TO 1207 LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656798Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 833 TO 930, RBL 33 TO RBL 55 FOUND DAMAGE. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656861Stiffener · crackedINSPECTION TYPE:C FWD CARGO COMPT STA 785.9 WING CENTER SECTION FRONT SPAR STIFFENER FOUND CRACK AT LBL 32.94 WL 194, CRACK LENGTH 1.125 INCH. FWD CARGO COMPT STA 785.9 WING CENTER SECTION FRONT SPAR AT LBL 32.94 STIFFENER REPAIRED PER HX RS R57-10-36376 REV SDR IPXA09656835Stiffener · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOORBEAM STIFFENER FOUND CRACK AT LBL 40, CRACK LENGTH 1.25 INCH. MAIN EQUIPMENT CTR STA 246 LBL 40 FLOORBEAM STIFFENER REPAIRED PER SRM 53-10-51-2R4 FIG 201 REV 44. THIS CLASSIFIED AS MAJOR REPAIR WITH MATERISDR IPXA09656797Floor Support · crackedINSPECTION TYPE:C AFT CARGO STA 1087 FLOOR PNL SUPPORT CLIP FOUND CRACK AT RBL 26, CRACK LENGTH 1 INCH. AFT CARGO STA 1087 FLOOR PNL SUPPORT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44 JUST AT RBL 26.SDR IPXA09656796Floor Support · crackedINSPECTION TYPE:C AFT CARGO COMPT STA 1087 FLOOR PNL SUPPORT CLIP FOUND CRACK AT LBL 26, CRACK LENGTH 1 INCH. AFT CARGO COMPT STA 1087 FLOOR PNL SUPPORT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656788Fitting · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOORBEAM CLIP FOUND CRACK AT RBL 10, CRACK LENGTH 1.75 INCH. MAIN EQUIPMENT CENTER STA 246 RBL 10 FLOORBEAM CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656787Fitting · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOORBEAM CLIP FOUND CRACK AT LBL 50, CRACK LENGTH 1 INCH. MAIN EQUIPMENT CENTER STA 246 LBL 50 FLOORBEAM CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656786Floorbeam · crackedINSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOORBEAM ANGLE FOUND CRACK AT LBL 25, CRACK LENGTH 075 INCH. MAIN EQUIPMENT CENTER STA 246 LBL 25 FLOORBEAM ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656709Floor Panel · crackedINSPECTION TYPE:PS D399757 MCD POS 12 RT 2ND FROM O/B FLOOR PANEL INTERIM REPAIR PERMANENT REPAIR AT C-CHECK. REPLACED FLOOR PANEL PER EO B767-5320-9693-F.SDR IPXA09656708Floor Panel · damagedINSPECTION TYPE:PS D399756 MCD POS 9 AND 10 RT 2ND FROM O/B PANEL INTERIM REPAIR 1 HOLE .5 INCH DEEP 1.5 X 1 INCH 2-HOLES WITH CRACKS BOX APPX 1 INCH FWD AREA POS 10 SAME FLOOR PANEL. PERMANENT REPAIR AT C CHECK. REPLACED FLOOR PANEL PER EO B767-5320-9693-F.SDR IPXA09656656Escape Rope · frayedINSPECTION TYPE:N/A ESCAPE ROPE FALLS OUT OF STORAGE POUCH AND BINDING DOOR AS IT OPENS. REPLACED DESCENT ROPE AND CHANNEL COVER.SDR IPXA09656636Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL DAMAGED. REPAIRED FLOOR PANEL.SDR IPXA09656634Floor Panel · damagedINSPECTION TYPE:N/A FLOORBOARD DAMAGED. FABRICATED FLOOR IAW EO B767-5320-9693.SDR IPXA09656606Floor Panel · dentedINSPECTION TYPE:N/A D395815: MCD FLOOR PANEL AT POS 10 RT OF CTR HAS DENT 1.875 X 1 INCH AT NR 8 PALLET LOCK. FABRICATED FLOOR PANEL PER EO B767-5320-9693 APPX B.SDR IPXA09656602Floor Panel · puncturedINSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PNL AT POS 10L .5 INCH PUNCTURE. REPAIR PER EO B767-5320-34205-A.SDR IPXA09656600Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL POS 10 DAMAGED. REPAIRED PER EO B767-5320-34204-A.SDR IPXA09656596Floor Panel · damagedINSPECTION TYPE:N/A MC DECK FLOOR PANEL POS 1 O/B RIGHT AT STA 368 HAS 1.25 X .875 INCH HOLE. FABRICATED REPLACEMENT PANEL PER EO D767-5320-9693-F.SDR IPXA09656675Support · crackedINSPECTION TYPE:7C RIGHT WING - L/E LES 675 FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR BRACKET FOUND CRACKED. RIGHT WING L/E LES 675 FIXED FAIRING UPPER SUPPORT WEB AFT FRONT SPAR BRACKET REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656660Fairing · delaminatedINSPECTION TYPE:C RIGHT WING I/B MAIN FLAP O/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5A (1) FIG 5 REV 44.SDR IPXA09656653Slat · debondedINSPECTION TYPE:7C LEFT WING - NR 4 SLAT O/B UPPER CORNER FOUND DEBOND. DEBOND AREA REPAIR PERFORMED AS PER SRM 51-70-10, REPAIR 1, FIG 201, SHEET 1, REV 44.SDR IPXA09656684Skin · crackedINSPECTION TYPE:7C NR 2 PYLON - ACCESS PANEL 442AL CUTOUT SKIN CRACKED. NR 2 PYLON I/B ACCESS FWD HOLE CUTOUT SKIN REPAIRED AS PER HX RS R54-51-36368 REV A AND UPS EO B767-5430-34212-A. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATERIAL AMS4911-0090IN ASDR IPXA09656683Fairing · delaminatedINSPECTION TYPE:7C LEFT WING - OUTBOARD T/E FLAP L/E INBOARD FAIRING DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5A (1), FIG 5, REV 44.SDR IPXA09656652Fairing · delaminatedINSPECTION TYPE:7C LEFT WING - O/B FLAP L/E MID FAIRING DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5A (1), FIG 5, REV 44.SDR IPXA09656651Skin Panel · dentedINSPECTION TYPE:7C LEFT WING L/E PANEL 511PT UPPER SURFACE FOUND DENT. METAL HOT BOND REPAIR PERFORMED AS PER SRM 51-70-10 REPAIR 2, FIG 203, REV 44.SDR IPXA09656624Attach Angle · crackedINSPECTION TYPE:7C AFT OF BULK CARGO COMPT STA 1582 LBL 81 MAIN DECK FLOORBEAM O/B ATT ANGLE FOUND CRACKED. MAIN DECK DOOR BEAM O/B ATTACH ANGLE AT BS 1582 LBL 81 AREA REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656564Skin · dentedINSPECTION TYPE:N/A RIGHT O/B FLAP TWO AREAS OF DENTS ON UPPER AND LWR SURFACE. REPAIRED REF EO-B767-5750-32516-B.SDR IPXA09656655Skin · dentedINSPECTION TYPE:7C LEFT WING NR 4 SLAT UPPER SURFACE FOUND DENT. METAL HOT BOND REPAIR PERFORMED AS PER SRM 51-70-10 REPAIR 4, FIG 202, SHEET 8, REV 44.SDR IPXA09656607Attach Angle · crackedINSPECTION TYPE:7C AFT OF BULK CARGO COMPT STA 1582 LBL 80 MAIN DECK FLOORBEAM ATTACH ANGLE FOUND CRACK. MAIN DECK FLOORBEAM ATTACH ANGLE AT BS 1582 LBL 80 AREA REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656598Attach Fitting · crackedINSPECTION TYPE:C MAIN E/E COMPT STA 246 RBL 10 MAIN DECK FLOORBEAM ATT CLIP FOUND CRACK (CRACK LENGTH 1.25 INCH). MAIN DECK E/E COMPT STA 246 RBL 10 FLOORBEAM ATTACH CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 44.SDR IPXA09656563Wedge · damagedINSPECTION TYPE:N/A RIGHT O/B FLAP T/E WEDGE DAMAGED. REPAIR PER EO B767-5750-32516-B.SDR IPXA09656674Fitting · crackedINSPECTION TYPE:7C AFT CARGO COMPARTMENT BILGE AREA STA 1087 LBL 26 CLIP FOUND CRACK. AFT CARGO COMPARTMENT BILGE AREA STA 1087 LBL 26 CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656673Fitting · crackedINSPECTION TYPE:7C AFT CARGO COMPARTMENT BILGE AREA STA 1087 RBL 26 CLIP FOUND CRACKED. AFT CARGO COMPARTMENT BILGE AREA STA 1087 RBL 26 CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.SDR IPXA09656659Skin · crackedINSPECTION TYPE:C LEFT WING NR 4 SLAT I/B NOSE SUPPORT SKIN FOUND CRACKED (CRACK 0.125 INCH LENGTH). LEFT WING NR 4 SLAT OSS 573.18 AREA NOSE SKIN REPAIRED AS PER SRM 57-43-01- 2R2 FIG 201 REV 44. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 7075-SDR IPXA09656654Hinge Fitting · crackedINSPECTION TYPE:7C LEFT WING - I/B MAIN FLAP I/B AFT FLAP HINGE FIG FOUND CRACKED. LEFT WING I/B MAIN FLAP I/B AFT FLAP HINGE FIG REPAIRED AS PER SRM 57-53-02- 2R1, FIG 201, REV 44. THIS REPAIR IS CLASSIFIED AS MAJOR REPAIR WITH MATERIAL AND 10134-2007-7075TSDR IPXA09656650Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 730 TO 833, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656646Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO 540, RBL 55 TO RBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656645Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 690 TO 764, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656644Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1197+22 TO 1207, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656643Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 730 TO 833, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656642Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 933 TO 870, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656641Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 654+22 TO 690 LBL 11 TO LBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.
Back to Boeing 767-34AF