Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA02701Shaft · shearedELEC BACKUP GEN L LEFT BACKUP GENERATOR IS OFF OR HAS FAILED. ADVISORY MSG01- LATCHED CRUISE MODE DEPENDENT; BACKUP GENERATOR (L) OIL PRESSURE IS LOW. DB- BACKUP CONVERTER MSG02- ACTIVE CRUISE MODE DEPENDENT; BACKUP GENERATOR (L) HAS A SHEARED SHAFT. DB- BSDR 2008UALA02700Charger · faultyAPU BATTERY CHARGE MESSAGE DISPLAYED ON EICAS. SUSPECT FAULTY BATTERY CHARGER. REPLACED BATTERY CHARGER PER MM 24-31-06. AC OK FOR SERVICE.SDR 2008UALA02729Converter · faulted"MANUALLY INITIATED ENGINE START TEST". THIS TEST GIVES FAULT, "BACKUP CONVERTER HAS INTERNAL FAULT". SUSPECT FAULTY CONVERTOR. REPLACED BACK UP GENERATOR CONVERTER PER MM 24-25-09. PASSED TEST PER MM 24-25-00. AC OK FOR SERVICE.SDR UALA2008111302679Door · crackedRT AFT NLG DOOR AFT LOWER CORNER CRACKED APPROX 3 X 1 INCH AREA. SUSPECT GROUND EQUIPMENT DAMAGE. INTERIM REPAIR PER EVA-71532. ** MF2588 CREATED TO MONITOR. AC OK FOR SERVICE.SDR 2008UALA02679Door · crackedRT AFT NLG DOOR AFT LOWER CORNER CRACKED APPROX 3 INCH BY 1 INCH AREA.SDR 2008UALA02663Oil Filter · false activationL ENG OIL FILTER STATUS MESSAGES. REPLACED MAIN OIL FILTER. NO SLUDGE OR CONTAMINATION NOTED, CHECKED MASTER CHIP DETECTOR, NOTHING FOUND. RAN ENGINE, CLEARED MESSAGE, NO FURTHER ANOMALIES NOTED. NO LEAKS NOTED AFTER ENGINE RUN.
SDR 2008UALA02641Skin · damagedA DENT WAS FOUND ON EXTERNAL SKIN OF BULK CARGO DOOR AT FWD LOWER CORNER. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. ACCMP HFEC INSP FOR CRACK FREE CUTOUT. INSTALLED REPAIR DOUBLER.SDR 2008UALA02627Engine · vibrationNR 1 ENGINE VIBRATION. FLT 803-05 DIVERTED TO SEA DUE TO PHYSICAL VIBRATION. VIB FOLLOWED THROTTLE. AVM PEGGED AT 10 UNITS. AFTER SHUTDOWN AT SEA, N1 ROTOR LOCKED UP. ENGINE REPLACED AT SEA. TEARDOWN REVEALED THAT THE THRUST BALANCE AIRSEAL (TB AIRSEAL) WAS SDR 2008UALA02642Warning Horn · false activationEQUIPMENT COOLING HORN SOUNDING AT DEPARTURE. RESETED ECSMC CARD POWER SWITCH AND RESETED C-B (G27) PER FIM 21-27 TASK 830. PERFORMED GROUND TEST PASSED, MSG DISAPPEAR. AC OK FOR SERVICE.SDR 2008UALA02625Relay · faultyFOUND MSG 24-13783, ALSO APU BATTERY WILL NOT DROP BELOW 31 VOLT. REPLACED RELAY. MSG CLEARED. AC OK FOR SERVICE.SDR 2008UALA02614Bearing · making metalMETAL DEBRIS FOUND ON NR 2 ENG MAGNETIC CHIP DETECTOR. SEM CONFIRMED BEARING MATERIAL. A/C FERRIED TO SFO FOR ENGINE CHANGE. ENGINE REPLACED AT SFO ON 5/4/08. SHOP TEARDOWN REVEALED THAT THE NR 1 BEARING HAD ONE BALL WITH A LARGE AREA OF SPALLATION, AND ITSSDR 2008UALA02613Warning Horn · malfunctionedEQUIPMENT COOLING HORN KEEPS GOING OFF. FOUND EQUIPMENT COOLING AIR FILTER DIRTY. REPLACED FILTER. RESET ECS CARD HORN SILENCED. AC OK FOR SERVICE.SDR 2008UALA02612Detector · failedICE DETECTOR L LEFT ICE DETECTOR FAILURE. STATUS CREW COMMENTS, STATUS MESSAGE ICE DETECTOR L MSG-3010141 ACTIVE ES HARD. REPLACED ICE DETECTOR LRU IAW MM30-81-01 OPS CHK GOOD. AC OK FOR SERVICE.SDR UALA2008111302571Actuator · faultyRT TANK QTY INCREASES 300 LBS EVERY 10 MINUTES WITH CENTER TANK PUMPS ON. OCCURS IN NORMAL CONFIGURATION, JUST CENTER TANK RT AND LT PUMPS ON. REPLACED FWD RT MAIN DISCHARGE CHECK VALVE. PROBLEM REOCCURRED. RPL'D L-H JETTISON ISO VALVE ACTUATOR. OP'S CHK OSDR 2008UALA02573Light · unsecureLIGHT STRIP LOOSE AT SEAT 1F ARMREST. FOUND LOOSE LIGHT STRIP. SECURED LIGHT STRIP OPS CHECK GOOD.AC OK FOR SERVICE.SDR 2008UALA02571Unknown · unknownRIGHT TANK QTY INCREASES 300 LBS EVERY 10 MINUTES WITH CENTER TANK PUMPS ON. OCCURS IN NORMAL CONFIGURATION, JUST CENTER TANK RIGHT AND LEFT PUMPS ON.SDR 2008UALA02496Filter · blockedRIGHT BACKUP GENERATOR FILTER BLOCKED UPON ARRIVAL. REPLACED RT BACK UP GENERATOR PER MM 24-25-01 OP AND LEAK CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA02482Battery · dischargedCREW REST AREA EMERGENCY LIGHTS FAILED TIME TEST. SUSPECT LOW BATTERY PACK. RECHARGED SYSTEM. OPS CK'D GOOD PER MM 33-51-00, PG 209.AC OK FOR SERVICE.SDR 2008UALA02481Battery Pack · failedCEILING AND EMERGENCY LIGHTS AT PED NR 1 LT FAILED TIME TEST. REPLACED POWER SUPPLY AT DOOR 1L AND CHARGED BATTERY PACK, OPS CHECK GOOD PER MM 33-51-00 PG 209.AC OK FOR SERVICE.SDR 2008UALA02450Idg · failedLEFT GENERATOR DROPPED OFF LINE. APU ON AND FLIGHT WILL CONTINUE. FOUND FAULTY IDG. REPLACED NR 1 IDG. RAN OP CHECKS. OKAY FOR SERVICE.
SDR 2008UALA02451Starter · misriggedNR 1 ENGINE START VALVE APPEARS TO BE ASSEMBLED IMPROPERLY TO ALLOW MANUAL START, VALVE DOES NOT ALIGN WITH TUBE IN COWL. FOUND ALIGNMENT TANG TO BE 30 DEGREES OFF WHEN ASSEMBLED IN SHOP. REPLACED STARTER VALVE REF MM 80-11-02, OPS CHECKS OK.AC OK FOR SERVICSDR 2008UALA02424Receiver · faultyPRE-DEPARTURE CHECK FOUND NO LAND 3 ILS C ON STATUS PAGE. FOUND CENTER INSTRUMENT LANDING SYSTEM RECEIVER FAULTY. REPLACED CENTER ILS RECEIVER PER AMM 34-31-01. CAT III CHECK OKAY PER AMM 22-11-00. AC OK FOR SERVICE.SDR 2008UALA02425Control Panel · faultedELMS P310 PANEL THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P310 PANEL IS FAULTED SUCH THAT IT CANNOT SUPPORT AIRPLANE DISPATCH. AIMS HAS LOST ARINC 629 COMMUNICATION WITH THE P310 PANEL, OR ONE P310 PANEL CHANNEL IS LOST AND THE OTHER FAULTED AND IS OPERATISDR 2008UALA02373Blades · damagedNR 1 ENG HPC STG 7 HAS SEVERAL DAMAGED BLADES BEYOND LIMITS AND ARE NOT BLENDABLE. ALSO, HPC STAGE 12 HAS 1 BLADE WITH CRACK BEYOND LIMITS. ENGINE CONDITION MONITORING (ECM) DETECTED AN ENGINE GASPATH PARAMETER SHIFT. SUBSEQUENT BORESCOPE INSPECTION (BSI) FSDR 2008UALA02391Light · missingSEAT MOUNTED EMERGENCY LIGHT AT 2F AFT MISSING. REPLACED LIGHT ASSY. OP CHK OKAY.SDR 2008UALA02390Light · inoperativeEMERGENCY LIGHTS ON SIDES OF SEATS 32G, 2F AND 9F ARE INOP. RELAMPED & REPLACED LIGHT ASSY AS NEEDED. OPS CK GOOD.SDR UALA2008111302332Fire Loop · faultyFIRE LOOP 2 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG01- ACTIVE CLIMB INTERMITTENT; FIRE LOOP 2 (RIGHT ENGINE) IS SHORTED. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG02- ACTIVE CLIMB HARD; ENGINE FIRE DETECTION CARD (RIGHT) HAS AN ISDR 2008UALA02365Feeder Cable · unsecureSEAT 2F BOTH EEL LTS INOP. DURING TROUBLESHOOT, FOUND UNDER SEAT POWER CABLE LOOSE. SECURED THIS CABLE. OP CHK'D OKAY.SDR 2008UALA02364Feeder Cable · failedSEAT 2E BOTH EEL LTS INOP. DURING TROUBLESHOOT, FOUND UNDER SEAT PWR CABLE FOR BOTH SEATS FAILED. REPLACED THIS CABLE. OP CHKS OKAY.SDR 2008UALA02334Bottle · reads lowLOW BOTTLE. SUPPLEMENTAL, FILLER VALVE LOOSE. TIGHTENED FILLER VALVE AND TOPPED OFF CYLINDER.SDR 2008UALA02332Fire Detector · faultyFIRE LOOP 2 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG01, ACTIVE CLIMB INTERMITTENT; FIRE LOOP 2 (RIGHT ENGINE) IS SHORTED. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG02, ACTIVE CLIMB HARD. ENGINE FIRE DETECTION CARD (RIGHT) HAS AN SDR UALA2008111302330Connector · unstableWHILE ACCOMPLISHING EG8515 FOR CARGO PIT FIRE BOTTLE CHECK, NOTICED THAT WHEN DISC SWITCH IS PUSHED THAT VOLTAGE AT SQB CONN SPIKES TO 24.96 VDC FOR A SPLIT SECOND THEN GOES BACK TO APPROX ZERO AND STAYS ZERO UNTIL 20 MINS WHEN IT GOES TO APPROX 24 VDC AS STATSDR 2008UALA02330Bottle · unknownWHILE ACCOMPLISHING EG8515 FOR CARGO PIT FIRE BOTTLE CHECK, NOTICED THAT WHEN DISC SWITCH IS PUSHED THAT VOLTAGE AT SQB CONN SPIKES TO 24.96 VDC FOR A SPLIT SECOND THEN GOES BACK TO APPROX ZERO AND STAYS ZERO UNTIL 20 MINS WHEN IT GOES TO APPROX 24 VDC AS STATSDR 2008UALA02306Acm · frozenLEFT PACK AIR CYCLE MACHINE FROZEN.SDR 2008UALA02302Battery · weakAPU ARRIVED AT GATE WITH AN APU WEAK BATTERY MESSAGE AND APU CHARGER MESSAGE. BATTERY VOLTS AT 24 VDC, CHARGER NO MORE THAN 1 AMP CHARGE. FOUND FAULTY CHARGER. REPLACED APU BATTERY CHARGER AND APU BATTERY, REF MM 24-31-06 AND MM 24-31-05. OPS TEST OK.AC OK SDR 2008UALA02335O-Ring · leakingLOW BOTTLE. SUPPLEMENTAL, GAUGE FITTING BACK UP RING LEAKS. REPLACED BACK UP RING.SDR 2008UALA02331Lamp · inoperativeFOUND DOOR 3L EXTERIOR EMERGENCY LIGHT INOP. FOUND FAULTY LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02272Converter · failedELEC BACKUP GEN R RIGHT BACKUP GENERATOR IS OFF OR HAS FAILED. RESET ONCE, TRIPPED AGAIN. TURNED OFF, MSG-2446090 LATCHED ER MODE. SUSPECT BUG CONVERTER HAS INTERNAL FAULT. REPLACED CONVERTER POWER TEST GOOD. AC OK FOR SERVICE.SDR 2008UALA02247Lamp · inoperativeEXTERIOR EMERGENCY LIGHTS AT DOORS 1L, 2R, AND 4R INOP.SDR 2008UALA02238Light · unsecureSEAT 1E EEL LIGHTING MOUNTED ON THE SEAT NEEDS TO BE SECURED.SDR 2008UALA02237Skin · crackedNR 1 SLAT, OUTBOARD TRACK HAS CRACK ON WING CUTOUT, ABOUT 1.25 INCH LONG. REMOVED 3 RIVETS AND 1 LOCK FASTENER. REMOVED DAMAGE LAID UP REPAIR AND STARTED CURE CYCLE. REF SRM 57-41-01. CURED THEN CLOSED UP. AC OK FOR SERVICE.SDR 2008UALA02205Unknown · unknownELEC BACKUP GEN L LEFT BACKUP GENERATOR OFF DUE TO A PROTECTIVE TRIP. STATUS MSG01- LATCHED CRUISE MODE DEPENDENT; BACKUP GENERATOR (L) OIL PRESSURE IS LOW. DB- BACKUP CONVERTER MSG-2446080 LATCHED ER MODE.SDR 2008UALA02204Fitting · strippedFOUND ACFT CREW O2 SERVICE FITTING STRIPPED.SDR 2008UALA02202Indication Sys · malfunctionedFUEL FLOW INDICATION (ENGINE), BLANK MSG01, ACTIVE DESCENT HARD; FUEL FLOW TRANSMITTER (R ENG) SIGNAL IS OUT OF RANGE. DB-ELECTRONIC ENGINE CONTROL (R ENG, CH A) MSG02- ACTIVE DESCENT HARD; FUEL FLOW TRANSMITTER (R ENG) SIGNAL IS OUT OF RANGE, MSG-7360952 ACSDR 2008UALA02203Charger · inoperativeBATTERY CHARGER MESSAGE ON EICAS. FOUND FAULTY BATTERY CHARGER AND BATTERY. REPLACED BATTERY AND BATTERY CHARGER. AC OK FOR SERVICE.SDR 2008UALA02201Processing Unit · faultedFUEL QUANTITY PROCESSOR HAS AN INTERNAL FAULT, CMC MSG 28-20050, ACTIVE. FOUND CHANNEL-L INOP, REPLACED FUEL QUANTITY PROCESSOR UNIT PER MM28-41-01-401, OPS NORMAL. AC OK FOR SERVICE.SDR 2008UALA02171Idg · faultedELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). AFTER EXTENSIVE TROUBLE SHOOTING AND PART REPLACEMENT. FOUND IGD FAULTY SUSPECT FAULTY BEARING. BUG REPLACED SUSPECT FAULTY BEARING. BACK UP CONVERTER REPLACED SUSPECT INTERNAL FAULT. ALL OPS ANSDR 2008UALA02159Lamp · burned outEMERGENCY LIGHT AT SEAT 12D AFT LIGHT IS BURNT OUT. RELAMPED. OPS CHECKED GOOD.SDR 2008UALA02169Battery · discharged10 MINUTES PRIOR TO DEPARTURE CREW CALL EICAS MSG 'APU BATTERY. FOUND FAULTY BATTERY. REPLACED APU BATTERY. AC OK FOR SERVICE.SDR 2008UALA02160Light · shortedEMERGENCY LIGHTS ON SEATS 31 TO 43 BOTH SIDES ARE NOT WORKING. FOUND SHORTED LIGHT ASSEMBLY SEAT 33A. REPLACED LIGHT ASSY,POWER SUPPLY ASSEMBLY OP CHECK GOOD. AC OK FOR SERVICE.
Back to Boeing 777-222