SDR 2007UALA04624Unknown · vibrationON STARTING LEFT ENGINE, LOUD RUMBLING NOISE AND HEAVY VIBRATION FELT IN CABIN. RAN NUMEROUS DIAGNOSTIC TESTS ON LT ENGINE. NO ENGINE PROBLEM NOTED. DURING DRY MOTORING, AIR SURGES THROUGH ENG CORE, SIMILAR TO PREVIOUS APU SURGE CONTROL VALVE FAULT, ACCOSDR 2007UALA04652Anti-Ice Valve · faultyICING WING PRIMARY ICE DETECTION SYSTEM (LEFT OR RIGHT ICE DETECTORS) DETECTS ICE, AND THE WING ANTI-ICING (WAI) SWITCH IS OFF. *S/D* REPLACED RIGHT WING ANTI-ICE VALVE PER MM 30-11-03 & ACCOMPLISHED OPS CHECKS PER MM 30-11-00, ALL OPS & INDICATIONS NOW NORMSDR 2007UALA04718Aspirator · leakingLOWER TUBE ASPIRATORS ARE LEAKING. REPLACED ASPIRATOR DURING SLIDE OVERHAUL. SUSPECT ASPIRATOR CRUSHED DURING ASSEMBLY.SDR 2007UALA04602Light · inoperativeAFT EEL LIGHT AT SEAT 1F INOP. REPLACED LIGHT ASSY AT SEAT 1F AFT.SDR 2007UALA04592Wire Harness · damagedFLAP SLAT SKEW MSG IN VIEW. FOUND WIRE HARNESS DAMAGED ON RT OUTBOARD FLAP-SLAT SKEW. REPLACED SKEW SENSOR NR 7 WIRING HARNESS. OP CHECKED PASSED. AC OK FOR SERVICESDR 2007UALA04573Filter · cloggedLEFT IDG "FILTER BLOCKED" ON ELECTRICAL PAGE. DELTA P IS POPPED. NO DEPOSITS FOUND IN FILTER. INSTALLED NEW FILTER PER MM24-11-02. OPERATED ENGINE AT IDLE AND FILTER MSG ON ELECT PAGE NOW NORMAL. A/C OK FOR SERVICESDR 2007UALA04577Wire · damagedNLG RED SAFETY LIGHT WILL NOT ILLUMINATE WHEN PTT SWITCH IS CLOSED. ALSO, WHEN CLOSING MLG AND NLG DOORS FROM GROUND CIRCUIT BREAKER IN COCKPIT FOR SAFETY VALVE TRIPS. SUSPECT BROKEN WIRE. REPAIRED WIRE IN LT MAIN WHEEL WELL. CLEANED LIGHT SOCKET IN NOSE WSDR 2007UALA04525Lamp · burned outEXIT EMERGENCY LIGHT AT DR 3R IS BURNT OUT. RELAMPED.SDR 2007UALA04513Skin · nickedNICK WAS FOUND ON OUTER SKIN OF LWR FUSELAGE CENTER LINE, STA 529, STR 46R. INSTALLED DOUBLER REPAIR OF SKIN DAMAGE. OK FOR SERVICE.
SDR 2007UALA04512Skin · dentedDENT ON STA 277 ABOVE STR 28 LT. NDT, NO CRACKS OUT OF LIMITS. ACCOMPLISHED CAT B. REPAIR . REQ FUTURE REINSPECTION. NEW CF WILL BE CREATED. PERMANENT REPAIR WITHIN 16,000 FC OR NEXT HMV. AC OK FOR SERVICE.
SDR 2007UALA04502Switch · faultyDOOR 3L EPAS POWER SUPPLY FAILS TEST. FOUND DOOR OPEN SWITCH BAD (S52125). WILL ALSO NEED SLIDE ASSY REPLACED. REPLACED DOOR OPEN SWITCH AT 3L. OP CHECKED GOOD, NO FAULTS. SLIDE ASSY REPLACED. A/C OK FOR SERVICE.SDR 2007UALA04468Light · inoperativeSEAT 1E FWD EEL INOP. REPLACED LIGHT ASSY AT 1E, OP CHECKS OK.
SDR 2007UALA04467Lamp · inoperativeEMERGENCY LIGHT ON GALLEY WALL ACROSS FROM DR 4R, AFT LIGHT IS OUT, RELAMPED.SDR 2007UALA04466Light · inoperativeEMERGENCY LIGHTS AT LT & RT SIDE BUSS CLASS AND COACH DIVIDER ARE OUT. RELAMPED EMERGENCY LIGHTS.SDR 2007UALA04478Fmc · malfunctionedCAPTAIN'S FMC POINTING 15 DEGREES RIGHT, F/O' S POINTS STRAIGHT AHEAD. LEFT CALCULATED BEARING HEADING 15 DEGREES DIFFERENCE FROM RIGHT. EXTENSIVE TROUBLE SHOOTING PERFORMED ON AIMS. UNABLE TO DUPLICATE FAULT. FMC TESTS NORMALLY AFTER RESET. A/C OK FOR SERSDR 2007UALA04348Drive Unit · failedWEATHER RADAR SYSTEM FAILURE. REPLACED RADAR ANTENNA DRIVE UNIT, OPS CHEKS OK. SUSPECT BAD ANTENNA CONNECTION. AC OK FOR SERVICE
SDR 2007UALA04321Toilet · leakingRTFL DUE TO WATER LEAK FROM THE GALLEY, SOAKING THE CREW REST AREA / PASSENGER SECTION. SUSPECT TOILET ASSEMBLY. REMOVED AND REPLACED THREE TOILET ASSEMBILES AT LAV 101, 131,141. REPLACED AFT DRAIN RESTRICTOR VALVE. OPS CHECK GOOD.SDR 2007UALA04342Light · inoperativeEMERGENCY LIGHT INOP SEAT 2E AFT LIGHT. REPLACED LIGHT.SDR 2007UALA04341Sign · looseMAIN AISLE EXIT SIGN AT 3L FOUND HANGING BY WIRE HARNESS. RESECURED SIGN.SDR 2007UALA04312Circuit Breaker · burnedAPU GEN IS INOPERATIVE. REPLACED APB CONTACTOR . APU OPS CHECKED GOOD. SUSPECT AUX POWER BREAKER BURNED AND UNABLE TO HOLD SET POSITION. AC OK FOR SERVICE.SDR 2007UALA04247Bleed Air Sys · unknownLEFT ENGINE BLEED PROBLEM. REPLACED UPPER FLOW CONTROL ISOLATION VALVE. OP CHECKS GOOD & AIRCRAFT RETURNED TO SERVICE.
SDR 2007UALA04231Flap System · malfunctionedFLAP SLAT STATUS MESSAGE DISPLAYED. REPLACED FLAP/SLAT ELECTRONICS UNIT 1 PER MM 27- 51-01. MSG CLEARED, SYSTEM OK FOR SERVICE.
SDR 2007UALA04165Fmu · leakingFUEL LEAKING BETWEEN FUEL PUMP AND FMU. REPLACED NR 2 ENG FMU UNIT. LEAK CHECKED OK. CAUSE WAS CONNECTION SECURITY OR FAULTY SEAL. VERIFICATION FLIGHT CONFIRMS NORMAL OPERATION.
SDR 2007UALA04164Light · inoperativeDOOR 4R EMERGENCY LIGHT IS INOP. 11-01-07 RELAMPED.SDR 2007UALA04118Skin · delaminatedNR 14 LEADING EDGE SLAT DELAMINATED OTBD END. REMOVED THE SLAT, BONDING REPAIRED, AND INSTALLED THE SLAT, PERFORMED ADJUSTMENT. PERFORMED SLAT SYS PRIMARY CONTROL TEST.TEST OK.SDR 2007UALA04116Battery Pack · faultyFOUND DOOR 2R EPAS BITE LIGHT IS NOT BLINKING GREEN. REPLACED EPAS BATTERY PACK. OP CHECK OK FOR SERVICESDR 2007UALA04117Hinge Fitting · damagedFOUND LIGHTNING STRIKE DAMAGE IS AT VERTICAL STAB REAR SPAR UPPER RUDDER HINGE FITTING AT RUB STA 522. REMOVED AND REPLACED HINGE FITTING. A/C OK FOR SERVICESDR 2007UALA04084Power Supply · inoperativeFOUND AFT CABIN ALL SEAT EEL INOP. REPLACED POWER SUPPLYSDR 2007UALA04056Bottle · faultyNR 3 MED EMERG SLIDE DOOR ASST BOTTLE NEEDS SERVICING. REPLACED BOTTLE AND SQUIB ASSEMBLY. OK FOR SERVICE
SDR 2007UALA04055Reservoir · failedFOUND DOOR 4R POWER ASSIST RESERVOIR SQUIB FAILS TEST. REPLACED DOOR ASSIST RESERVOIR. BITE TEST OK FOR SERVICE.SDR 2007UALA04054Slide · faultyNR 3 LT MED SLIDE IS FAULTY. REPLACED SLIDE ASSY. OK FOR RETURN FOR SERVICE.SDR 2007UALA03962Eec · unknownRTFL DUE TO NR 1 ENG ELECTRONIC ENGINE CONTROL ISSUES. 10-26-07 TROUBLESHOOTING ISOLATED PROBLEM TO P2 MANIFOLD (PRESSURE INPUT) P2 MANIFOLD IS BLOCKED OR LEAKING. HAD ELECTRONIC ENGINE CONTROL MSG ON L ENG, CH B. CHECKED CONNECTIONS ON P2 MANIFOLD AND LISDR 2007UALA04004Slide · misinstalledDOOR 2R ESCAPE SLIDE PACK IS FAULTY. 2R ESCAPE SLIDE PACK REPLACED. SLIDE APPEARED TO BE IMPROPERLY INSTALLED. AIRCRAFT OK SERVICE.
SDR 2007UALA04003Bracket · damagedDOOR 2R GIRT BAR PICK UP LINKAGE BRACKET DAMAGED. REMOVED FROM RT SIDE. REPLACED BRACKET AND REINSTALLED SLIDE. OK FOR SERVICESDR 2007UALA03978Battery · failedAPU BATTERY FAILURE. 10-26-07 REPLACED APU BATTERY & APU BATTERY CHARGER, SYSTEM OP CHECKS GOOD.SDR 2007UALA04009Connector · unsecureEEL AT FIRST CLASS SEAT 3E INOP. SECURED EEL CONNECTOR.SDR 2007UALA04008Light · inoperativeEEL AT FIRST CLASS SEAT 2E INOPERATIVE. RECONNECTEDSDR 2007UALA03957Circuit Card · faultyAPU FIRE CARD MESSAGE DISPLAYED. 10-23-07 REPLACED CARDS A9 & A12. MESSAGE CLEARED. AIRCRAFT RETURNED TO SERVICE.SDR 2007UALA03930Warning Message · illuminatedWINDSHEAR PREDICTIVE STATUS MSG. R SYS OK L SYS INOP. WINDSHEAR ALERTING FUNCTIONS ARE FAILED SUCH THAT WINDSHEAR ALERTING CAPABILITY IS REDUCED OR NOT AVAILABLE. A REACTIVE WINDSHEAR FAILURE WILL ONLY SET THE MESSAGE WITH THE REACTIVE WINDSHEAR OPTION ACTIVSDR 2007UALA03928Cabin Pressure · fluctuatesFLIGHT EXPERIENCED PRESSURIZATION FLUCTUATIONS. PERFORMED GROUND TEST OF ( L) AND (R) AUTO PRESS CONTROLLERS AND CHECKED NORMAL. NO HISTORY ON THIS AUTO PRESS CONTROL SYS. AS PRECAUTION ALSO CHECKED MANUAL OPERATION OF FWD AND AFT OUTFLOW VLVS. CONDUCTED SDR 2007UALA03927Lens · missingTHE 33C, 35G & 37G EEL LIGHT LENSES ARE MISSING. RE-LENSED AS PER MM 33-51-05. OP CHECKED PER SAME, SYS OPS NORMALLY. RETURNED AC BACK TO SERVICE.
SDR 2007UALA03926Lamp · inoperativeTHE 12F AFT EEL LIGHT INOPERATIVE. *S/D* RELAMPED AS PER MM 33-51-05 OPS CKD PER SAME, SYS OPERATED NORMALLY.SDR 2007UALA03909Engine · fodLEFT ENGINE HAS SIGNS OF BIRD STRIKE. ACCOMPLISHED INSPECTION OF ENGINE PER MM 72-00-00. CONFIRMED FOD DAMAGE TO 7TH STAGE COMPRESSOR. 7TH STAGE BLADE IS OUT OF LIMITS. WHEN LOOKING THROUGH AP5 PORT. ALSO FOUND LESS SIGNIFICANT DAMAGE TO 10TH AND 11TH STASDR 2007UALA03870Indicator · faultyBOTTLE DISCHARGE LIGHT AND FIRE BOTTLE ARMED LIGHT ON NOSE GEAR APU GROUND CONTROL PANEL WILL NOT PRESS TO TEST. RELAMPED BOTTLE DISCHARGE LIGHT, NO HELP. REPLACED FIRE BOTTLE ARMED LIGHT INDICATOR. OP CHECKS OK FOR SERVICE.SDR 2007UALA03871Connector · disconnectedCREW REPORT - EEL STRIP LIGHT AT SEAT 3F LOOSE. LIGHTING IN PLACE BUT NOT WORKING. RECONNECTED CONNECTOR AND EEL STRIP, OPS CHECKS OK FOR SERVICE.SDR 2007UALA03876Terminal · corrodedAPU DISCHARGE LIGHT ON INTERMITTENTLY. CLEANED CORRODED TERMINALS AT L26504 GD TERMINAL 2, AT P5 BTL DISCH AND AT P40 BTL DISCH LIGHT. OP CHECKS GOOD.SDR 2007UALA03860Oil System · overtempNR 1 ENGINE HIGH OIL TEMPERATURE. 10-19-07 REPLACED SERVO FUEL HEAT EXCHANGER. ACCOMPLISHED PACK BURN AND FIM 71 -08 TASK 821 AFTER REPLACEMENT. NO ODOR IN CABIN. AIRCRAFT RETURNED TO SERVICE.SDR 2007UALA03799Girt Bar · bentCREW VERBAL: FLIGHT ATTENDANT REPORTS DOOR 2R DISARM LEVER IS STIFF. 10-16-07 REINSTALLED GIRT BAR ACP INSPECTION OF DOOR AND ARMING MECHANISM .DOOR OPS NORMAL. REPLACED GIRT BAR PICK-UP FITTING. FOUND AFT HOOK ASSY. BENT. GIRT BAR IS BINDING ON AFT FLSDR 2007UALA03788Fseu · failedPRIMARY SLATS FAIL ON FINAL. 10-16-07 REPLACED FSEU 2 PER MM 27-51-01. ACCOMPLISHED MAT TEST AND TEST PASSED. SLAT PROBLEM STILL CHRONIC. REPLACED SLAT PRIMARY CONTROL VALVE PER 27-81-05. LEAK CHECK OK. PERFORMED SLAT PRIMARY CONTROL VALVE TEST. FOLLOSDR 2007UALA03780Starter · malfunctionedAPU START SYSTEM APUC DETECTED FAILURE IN THE ELECTRIC STARTER, FUEL SCHEDULING, IGNITION, OR LUBE DEPRIME SYSTEMS OR NO SIGNAL FROM ELMS TO THE APUC. 10-16-07 REPLACED APU IGNITOR PLUG NR 1 PER MM49-41-02, AND IGNITION LEAD NR 1 PER MM49-41-04. APU BIT