SDR 2007UALA03785Pump · failedNR 2 ENG EDP FAILED DURING ENG RUN. 10-16-07 REPLACED ENGINE DRIVEN HYDRAULIC PUMP PER MM 29-11-0 5. FOUND SLUDGE IN LINES & FLUSHED SYSTEM LINES. ALL VALVES CHECKED OK. HYDRAULIC SYSTEM CHECKS OK FOR SERVICE.SDR 2007UALA03742Engine · shutdownCREW REPORTED LEFT ENGINE AUTO SHUTDOWN, HIGH VIBRATION AND HIGH EGT.SDR 2007UALA03733Lamp · failedDOOR 3R EXTERIOR EMERGENCY LIGHT FAILED TO ILLUMINATE DURING TEST. 10-9-07 REPLACED LAMP. EMERGENCY LIGHT OP CHECKED OK FOR SERVICE.SDR 2007UALA03709Light · inoperativeEMERGENCY LIGHT AT SEAT 35G INOP. REPLACED LIGHT ASSY.SDR 2007UALA03670Blade · failedRTFL DUE TO RIGHT ENGINE FAILURE. ENGINE REPLACED. SHOP TEARDOWN REVEALED AN HPT STAGE-1 BLADE FAILED AT THE ROOT. THE REMAINDER OF THE TURBINE SUFFERED HEAVY RESULTANT DAMAGE. STRESS CORROSION CRACKING, A KNOWN FAILURE MODE, IS SUSPECTED, BUT COULD NOT BE CSDR 2007UALA03683Warning Message · activatedBATTERY CHARGER APU; STATUS MESSAGE RECEIVED. 10-5-07 REPLACED APU BATTERY CHARGER, BATTERY, AND CARD M24406A4 IN PANEL P310, OP CHECKS OK.SDR 2007UALA03677Light · inoperativeSEAT 36C EEL LIGHT IS INOP. 10-05-07 REPLACED LIGHT. CHECKS GOOD.SDR 2007UALA03676Light · missingSEATS 1E & 1F EACH HAVE ONE EEL LIGHT MISSING. 10-05-07 REPLACED LIGHT IN EACH SEAT POSITION. CHECKS GOOD.SDR 2007UALA03678Connector · damagedHYD PUMP DEM C2 LOW CENTER HYDRAULIC DEMAND PUMP NR 2 PRESSURE WHEN COMMANDED ON, OR CENTER DEMAND PUMP NR 2 OVERHEATED. 10-05-07 AFTER TROUBLESHOOTING & HISTORY REVIEW, DETERMINED THAT NR 2 CONTROL HYD PUMP OPERATED OK FOR SEVERAL LEGS AFTER PIN D7716B (SDR 2007UALA03620Structure · damagedEXTERNAL FUSELAGE FWD OF NR 2 MAIN ENTRY DOOR IS DAMAGED. 10-11-07 MAJOR REPAIR DOUBLER INSTALLED FWD OF NR 2 MAIN ENTRY DOOR REF SRM 53-00-01.
SUSPECT DAMAGE DUE TO IMPACT WITH GROUND EQUIPMENT.SDR 2007UALA03642Light · inoperativeEEL LIGHT INOPERATIVE 42D. 10-11-07 RELAMPED AS PER MM33-51-05. OP CHECKED PER SAME, SYS OPS NORM. RETURNED AC BACK TO NORMAL, OK FOR SERVICE.SDR 2007UALA03619Oxygen Mask · leakingOXYGEN MASK PROBLEM CREW COMMENTS: CAP OXYGEN MASK LEAKS. 10-11-07 REPLACED CAPTAIN'S OXYGEN MASK. LEAK CHECKS GOOD. OK FOR SERVICE. SUSPECT PRESSURIZATION CYCLES & CARELESS STOWAGE CAUSED THE LEAKAGE.SDR 2007UALA03613Light · inoperativeEMERGENCY LIGHTS INOP AT SEATS 21C & 9F FWD LT.SDR 2007UALA03589Light · inoperativeEEL LIGHT AT SEAT 37G IS INOP.SDR 2007UALA03564Structure · damagedLIGHTNING STRIKE AT STA 496 RBL 1 & STA 613 STR 1L.SDR 2007UALA03544Float Valve · stuckFUEL IMBALANCE EXIST WHEN CTR TANK FUEL IS PRESENT. RT MAIN RECEIVING EARLY TRANSFER FROM SCAVENGE PUMPS. SUSPECT CTR TANK SCAVENGE FLOAT VLV STUCK IN OPEN POSITION AFTER T/S WITH FLT CREW.SDR 2007UALA03550Smoke Detector · inoperativeAFT LOWER CARGO COMPARTMENT SMOKE DETECTION SYSTEM INOPERATIVE. REPLACED DETECTOR.SDR 2007UALA03501Light · brokenSEAT 1E HAS ONE EEL LIGHT BROKEN.SDR 2007UALA03491Unknown · unknownENG OIL PRESS L LEFT ENGINE OIL PRESSURE BELOW THE RED LINE LIMIT WITH ENGINE RUNNING. ENGINE REPLACED AT ORD. SHOP TEARDOWN REVEALED A FAILURE OF THE NR 2 BALL BEARING. A 2.5" CIRCUMFERENTIAL X 1" WIDE CHUNK WAS BROKEN OFF OF THE OUTER RACE. THE BEARING HSDR 2007UALA03490Unknown · unknownCREW COMMENTS: RIGHT HYDRAULIC QTY DROPPED TO .40 IN FLT.SDR 2007UALA03471Generator · faultyRIGHT BACKUP GENERATOR FAILED.SDR 2007UALA03470Engine · faultyCREW REPORTS APU AUTO SHUTDOWN WHILE AT THE GATE. AFTER TROUBLESHOOTING & DURING RESTART OF APU HAD A TAIL PIPE FIRE, SHUTDOWN APU.SDR 2007UALA03469Battery · reads lowAPU BATTERY NOT CHARGING.SDR 2007UALA03468Skin · delaminatedNR 9 SLAT OUTBOARD EDGE DELAM ON UPPER AND LOWER SURFACE.SDR 2007UALA03452Light · unsecureEMERGENCY LIGHT STRIP AT SEATS 1E AND 2E COMING LOOSE. SECURED EEL STRIP AT ASSOCIATED SEATS. OP CHECKS GOOD.SDR 2007UALA03394Light · inoperativeAFT EMERGENCY LIGHT AT SEAT 1F IS OUT. REPLACED LIGHT ASSY. OPS CHECK GOOD.SDR 2007UALA03376Oil System · lowNR 1 ENG SHUTDOWN DUE EICAS AT 10,000 FT FOR OIL PRESSURE AND QUANTITY ZERO. EMERGENCY DECLARED BY CREW. ENGINE REPLACED. FOUND ONE HPT STAGE-2 BLADE FAILED UNDER THE PLATFORM DUE TO STRESS CORROSION CRACKING (SCC). AN ADJACENT BLADE WAS FRACTURED 0.100 ISDR 2007UALA03363Light · inoperativeEXTERIOR EMERGENCY LIGHTS AT DOORS 4L AND 4R ARE INOP. RELAMPED LT AND RT EXT EMERGENCY LIGHTS AT DOOR 4 RT AND LT PER MM 33-51-00.SDR 2007UALA03364Cover · misinstalledDOOR 4R AFT GIRT BAR DOESN'T SHOW ARMED. FOUND AFT GIRT BAR POSITION INDICATOR PLASTIC COVER IN UPSIDE DOWN POSITION. REINSTALLED COVER. GIRT BAR SHOWS ARMED.SDR 2007UALA03345Battery · faultyMAIN BATTERY + BATTERY CHARGER MAIN STATUS MSG WITH MAIN BATTERY DISCHARGE EICAS. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM24-31-02 AND 24-31-01. BOTH CHECK OK FOR SERVICE.SDR 2007UALA03319Warning System · activatedBATTERY CHARGER AND APU BATTERY MESSAGES DISPLACED ON STATUS PAGE. REPLACED BATTERY AND CHARGER PER MM24-31-05 & MM24-31-06. OP CHECKS READY FOR SERVICE.SDR 2007UALA03338Circuit Card · failedHYD PUMP DEM C1 MESSAGE. ACP FAILED GROUND TEST. REPLACED C1 LOGIC SPEED CONTROL CARD AND OPS TEST OK IAW AMM 29-11-15.SDR 2007UALA03316Light · inoperativeSEAT 11F EEL LIGHT INOPERATIVE. RELAMPED, OPS CHECKS GOOD.SDR 2007UALA03280Light · inoperativeAFT PROX EEL LIGHT AT SEAT 3F IS INOP. 08-31-07 REPLACED LIGHT ASSY. OP CHECKS GOOD.SDR 2007UALA03237Light · inoperativeFOUND SEAT 1F HAS AFT EEL LIGHT INOPERATIVE. 08-31-07 REPLACED LIGHT ASSY. OP CHECKS GOOD.SDR 2007UALA03236Controller · faultedDET CHAN 1 CARGO FWD FORWARD CARGO COMPARTMENT SMOKE DETECTOR CONTROLLER CHANNEL NR 1 FAILURE STATUS. 08-31-07 PERFORMED MTCE ACCESS TERMINAL FWD CARGO SMOKE DETECTOR TEST. SHOWS INTERMITTENT FAULT, MSG 26-20021. :REPLACED CARGO SMOKE DETECTOR. OP CHECSDR 2007UALA03230Fire Warning · illuminatedDURING PUSH-BACK, CREW HAD AN APU FIRE WARNING INDICATION. 08-31-07 REPLACED APU. ALSO, ACCOMPLISHED APU FIRE EXTINQUISHUNG BOTTLE REPLACEMENT PER MM 26-22-01-401. SUSPECT INTERNAL APU FAILURE: SYMPTOMS CONSISTENT WITH T1 BLADE FAILURE.SDR 2007UALA03217Unknown · odorCREW REPORTS HAD ELECTRICAL ODOR COMING FROM THE CHIME MODULE. 08-31-07 REPLACED FORTRESS DOOR STRIKER ASSY & OP CHECKS OK PER MM 52-51-02 PG401.SDR 2007UALA03216Wire Harness · damagedFOUND ENGINE HARNESS W0623 DAMAGED AT 9 O'CLOCK POSITION. BUNDLE MELTED THRU TO INNER WIRES. FOUND ENG HARNESS W0623 DAMAGED AT 9 O'CLOCK. BUNDLE MELTED THRU TO INNER WIRES. REPLACED HARNESS, READJUSTED CLAMPS, RAN ENGINE AND ALL CHECKED NORMALLY.SDR 2007UALA03150Cover · out of positionEMERGENCY LIGHT COVER OFF AT 19C. 10-23-07 REPLACED EEL LIGHT ASSY TO PROVIDE COVER WITH RETAINERS. AIRCRAFT OK FOR SERVICE.SDR 2007UALA03151Apu · shutdownAPU AUTO SHUT DOWN AT DEPARTURE. 10-23-07 REPLACED APU PER MM 49-11-01. ACCOMPLISHED APU VERIFICATION FLIGHT. ACCEPTED BY FLT CREW AND RETURNED TO FULL ETOPS SERVICE.SDR 2007UALA03116Aspirator · leakingBOTH ASPIRATORS ARE LEAKING FROM THE FLAPPER VALVES. REPLACED ASPIRATORS. 08-31-07 SUSPECT ASPIRATOR BODIES CRUSHED DURING PACKING.SDR 2007UALA03084Brake Assy · malfunctionedLANDED UNDER AMBER ALERT DUE TO HYDRAULIC QUANTITY INDICATION. 08-31-07 AFTER TROUBLESHOOTING, THERE WAS EVIDENCE OF LEAKING & BRAKE CONTAMINATION W/ HYD FLUID, REPLACED NR 2 CENTER BRAKE ASSY, INCLUDING SUSPECTED LEAK SOURCE, THE HYDRAULIC COUPLING TO BRSDR 2007UALA03048Wire Harness · damagedENGINE CONTROL SYSTEM IS OPERATING WITH REDUCED REDUNDANCY. FAULTY T3 INDICATION. REPLACED WO636 HARNESS.SDR 2007UALA03047Connector · unsecureFIRST CLASS SEATS 1E, 1F, 2E AND 2F FWD AND AFT EMERGENCY LIGHT ASSEMBLIES ARE INOPERATIVE. 08-31-07 SECURED POWER JUMPER PLUGS AT SEAT 2E. EEL LIGHT ASSY TESTED OK FOR SERVICE.SDR 2007UALA03046Sensor · leakingFOUND OIL LEAKING FROM COVER PLATE ABOVE OIL PRESSURE SENSOR AT APU LUBE CLUSTER, ALSO FOUND OIL LEAKING FROM GENERATOR FEEDER CABLES. FOUND GENERATOR SOAKED WITH OIL AND GENERATOR FEEDER CABLES ARCING AND BURNED. APU WAS FOUND LOW ON OIL. 08-31-07 REPLACSDR 2007UALA03031Line · failedC-HYD FAILURE AFTER FINAL APPROACH. 08-31-07 REPLACED INBOARD. NOSE STEERING HYDRAULIC LINE. PRESSURE CHECKED SYSTEM. CHECKED OK FOR SERVICE.SDR 2007UALA03034Light · inoperativeEMERGENCY EEL LT INOP AT SEAT 35CD. 08-31-07 REPLACED LT ASSY AT SEAT 35CD. OP CHECKED OK.SDR 2007UALA03033Wire · shortedEMERGENCY EXIT LIGHTS AT SEATS 3E (AFT SIDE) AND 3F (AFT POSN) ARE INOPERATIVE. 08-31-07 FOUND SHORT IN-SEAT EEL STRIP. REPLACED EEL LIGHT ASSY. OP CHECKS OK.SDR 2007UALA02987Transducer · reads lowO2 PRESSURE TRANSDUCER READS 300 PSI TO LOW. REPLACED TRANSDUCER. READINGS NOW IN CORRECT RANGE. AIRCRAFT OK FOR SERVICE.