SDR 2007UALA05142Smoke Detector · faultySMOKE DETECTOR GOING OFF IN LAV AT DOOR 3. SUSPECT INSTALLATION SHORT ADJUSTED SMOKE DETECTOR FOR SENSITIVITY TEST OK. AC OK FOR SERVICE.SDR 2007UALA05110Smoke Detector · faultyDET ZONE 1 CARGO AFT AFT CARGO COMPARTMENT SMOKE DETECTOR ZONE FAILURE, SUSPECT SMOKE DETECTOR AT FAULT. REPLACED AFT PIT SMOKE DETECTOR. OPS CHECKED GOOD. AC OK FOR SERVICESDR 2007UALA05119Valve · shutdownAPU AUTO SHUTDOWN AT DEPARTURE. HIGH OIL TEMP. ALSO, APU OIL PRESSURE -3 PSI. REPLACED LUBE CLUSTER AND THERMAL BYPASS VALVE
A/C OK FOR SERVICE.SDR 2007UALA05109Carbon Seal · leakingLANDED UNDER EMERGENCY CONDITIONS DUE TO REPORTED SMOKE IN THE CABIN. SLIDE RAFTS DEPLOYED AND AIRCRAFT EVACUATED ONCE CLEAR OF ACTIVE. NR 2 ENGINE REPLACED AT ORD DUE TO HEAVY METAL DEPOSITS ON MAGNETIC CHIP DETECTORS. TEARDOWN REVEALED A FAILURE OF NR 2 BSDR 2007UALA05107Light · brokenFOUND SEAT 32R, SEAT EEL BROKEN. REPLACED LIGHT ASSY.SDR 2007UALA05106Light · brokenFOUND SEAT 33R, SEAT EEL LIGHT BROKEN. REPLACED LIGHT ASSY.SDR 2007UALA05105Terminal Block · brokenSIDE EEL LIGHTS OF MID GALLEY, 3 EA, INOP. FOUND TERMINAL BLOCK BROKEN. REPLACED.SDR 2007UALA05104Switch · faultedLEFT FWD WINDSHIELD HEAT INOPERATIVE. FOUND FAULTY SWITCH. REPLACED LT FWD SWITCH CAP AND MODULE, OPERATIONAL CHECK GOOD. A/C OK FOR SERVICE.SDR 2007UALA05103Light · inoperativeFOUND SEAT 3E AND SEAT 2F (1 OF 2) EMERGENCY PROX LIGHTS INOPERATIVE. REPLACED LIGHT ASSY.SDR 2007UALA05076Idg · failedLT GENERATOR FAILURE ON TAKEOFF ROLL. DISCONNECTED GENERATOR AND CONTINUED TO ORD AFTER PHONE PATCH WITH SAMC AND DISPATCH. NR 1 ENGINE INTEGRATED DRIVE GENERATOR FREQUENCY IS LOW. REPLACED NR 1 IDG. AC OK FOR SERVICE.SDR 2007UALA05065Girt Bar · misinstalled1R DOOR SLIDE-RAFT GIRT BAR IN INSTALLED INCORRECTLY. GIRT BAR IS INSTALLED INCORRECTLY. INSTALLED GIRT BAR AND SLIDE. AC OK FOR SERVICE.SDR 2007UALA05064Bracket · misinstalledIMPROPERLY INSTALLED GIRT BAR RESULTING IN SLIDE DEPLOYMENT WHEN SLIDE LEVER IN DISARMED POSITION. FWD FLAG BRACKET BROKEN. REPLACED FLAG BRACKET SLIDE AND BOTTLE. GIRT BAR ENGAGES NORMAL. AC OK FOR SERVICE.SDR 2007UALA05062Wire · damagedF/O WINDSHIELD OVERHEATED AND STARTED TO SMOKE AT THE WINDOW TERMINAL LUGS. FWD WINDOW HEAT WAS TURNED OFF AND WINDOW DOES NOT SHOW SIGNS OF CRACKING OR DELAMINATION PER CREW. REPLACED WINDOW AND SPLICED IN NEW WIRE TO WIRE HARNESS. SUSPECT WIRE CRACK OR OPENSDR 2007UALA05039Battery · faultyFOUND EMERGENCY FLASH LIGHT USED AT DOOR 3R. REPLACED BATTERY.SDR 2007UALA05037Lens · brokenFOUND EMERGENCY EXIT PATH LIGHT BROKEN AT ROW 37G. REPLACED BROKEN LENSSDR 2007UALA04991Skin · misrepairedEXTERNAL FUSELAGE HAS 1 EA LARGE TRI-WING FASTENER INSTALLED THROUGH SKIN AT STATION 2200 NEAR STRINGER 32R. SUSPECTED LIGHTNING STRIKE. FASTENER IS SUBSTITUTED FOR RIVET SRM 51-40-03-001 PARA 4. REMOVED FASTENER DID HFEC INSP, NO CRACK. INSTALLED REPAIR 5SDR 2007UALA05038Sign · looseFOUND EMERGENCY EXIT SIGN ABOVE DOOR 4L IS LOOSE. SECURED SIGN.SDR 2007UALA05036Wire · shortedFOUND COACH SEAT ROWS 17 THRU 26 SEAT MOUNTED EEL LIGHTS ARE INOP. FOUND SHORTED CONNECTION. CLEARED SHORT. REPLACED FUSE IN POWER SUPPLY.
SDR 2007UALA05003Lens · missingFOUND SEAT 3F EEL LIGHT COVER IS MISSING. REPLACED LENS.SDR 2007UALA05005Skin · delaminatedRIGHT SIDE OF THE VERTICAL STABILIZER IS DELAMINATED. BLISTER ON VERTICAL FIN BETWEEN STATIC PORTS RT PANEL REMOVED FOR REPAIR. SENT TO SHOP 273. R&R R30639. REINSTALLED PANEL. AC OK FOR SERVICE.SDR 2007UALA04981Blades · failedFLIGHT CANCELLED DUE TO RT ENGINE VIBRATION AND METAL CHIPS FOUND ON DETECTOR. ENGINE REPLACED AT LHR. SHOP TEARDOWN REVEALED ONE STAGE-2 HP TURBINE BLADE FRACTURED AT THE AIRFOIL MID-SPAN. THE FRACTURE WAS THE RESULT OF INTERNAL SULFIDATION RESULTING FROM TSDR 2007UALA04968Window · faultySTATUS MSG, `WINDOW HEAT L FWD` DISPLAYED MAINT MSG 30-21031. FOUND OPEN CIRCUITS ON PRIMARY AND SPARE SENSORS ON WINDOW. REPLACED WINDOW PER 56-11- 01. AC OK FOR SERVICE
SDR 2007UALA04947Blade · damagedNR 2 ENG HAS HPT STG 1 BLADE TRAILING EDGE BREAKTHROUGH INTO INTERNAL CAVITY. 1 BLADE TRAILING EDGE BREAKTHROUGH INTO INTERNAL CAVITY. REPLACED WITH ESN 222175 IN POS 02. PER TOD AMM 71-00-02 CONFIG 2 FIG 422.SDR 2007UALA04945Seal · damagedDURING A-CHECK SERVICE OF NR 1 IDG, FOUND IDG LEVEL LOW. FOUND EVIDENCE OF INPUT SHAFT SEAL OF IDG LEAKING. INPUT SHAFT SEAL OF IDG LEAKING. REPLACED IDG. AC OK FOR SERVICE.SDR 2007UALA04927Girt Bar · dirtyDOOR 4L WILL NOT ARM. REMOVED FOREIGN OBJECT. LT SIDE OF GIRT BAR, OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2007UALA04896Cover · missingTHE 37C EMERGENCY EXIT COVER IS MISSING. REPLACED LIGHT.SDR 2007UALA04872Connector · damagedRIGHT UTILITY BUSS NO POWER. FOUND PIN "A1" DAMAGED ON M24211 & ON RECEPTICAL. REPLACED P200 PANEL. ACCOMPLISHED P200 PANEL OP CHECK. A/C OK FOR SERVICE.SDR 2007UALA04868Battery Pack · misinstalledNR 4 RT PED EPAS BATTERY HAS BEEN FOUND INSTALLED UPSIDE DOWN, NEW TYPE BATTERY PACK. REINSTALLED CORRECTLY. AC OK FOR SERVICE.
SDR 2007UALA04870Light · faultyAFT GALLEY LT AFT CEILING LIGHT BLINK. RELAMPED LIGHT.SDR 2007UALA04869Oven · faultyOVEN R-52 WILL NOT TURN OFF. OVEN WAS SMOKING AND C/B WAS PULLED BY CREW PER SAM. POWER SWITCH STAYS IN ALL THE TIME, REPLACED OVEN. AC OK FOR SERVICE.SDR 2007UALA04853Unknown · odorSMOKE ODOR IN AREA OF AFT GALLEY. CREW DEBRIEF STATED ODOR PREVELANT THROUGHOUT CABIN , INSPECTED E&E COMPARTMENT , OVERHEAD AREA AT FWD GALLEY AND LAVS , AFT AND MID GALLEYS WITH ALL ELECTRICAL EQUIPMENT POWERED. TOOK AIRCRAFT TO PAD FOR HIGH POWER RUN WITH SDR 2007UALA04807Detector · faultyICE DETECTOR R RIGHT ICE DETECTOR FAILURE. FAILED TEST NUMEROUS TIMES. REPLACED RT ICE DETECTOR. TESTED NORMAL AND MESSAGE GONE PER MM 30-81-01. AC OK FOR SERVICE.SDR 2007UALA04824Engine · making metalUNABLE TO START NR 2 ENGINE. FOUND METEL ON NR 2 ENG MAIN GEARBOX CHIP DETECTOR. SUSPECT BEARING FAILURE. REPLACED NR 2 ENG. AC OK FOR SERVICE.SDR 2007UALA04808Light · missingEMERGENCY ESCAPE PATH LIGHT (AFT) ON SEAT 2E IS MISSING. REPLACED LIGHT ASSY.SDR 2007UALA04806Lamp · brokenEEL LIGHTING AT SEAT 1E BROKEN. INSTALLED LAMPSDR 2007UALA04795Igniter · failedIGNITOR L1 FAILED TO START LEFT ENG.SDR 2007UALA04773Line · leakingNR 2 ENGINE BLEED PROBLEMS. SECURED HPSOV MUSCLE LINE. ALL PRESSURES CHECK NORMAL. AC OK FOR SERVICE.SDR 2007UALA04785Light · inoperativeDOOR 3R EXTERIOR SLIDE LIGHT INOPERATIVE. DOOR 3R EXTERIOR SLIDE LIGHT INOPERATIVE , REPLACED BULB OK FOR SERVICESDR 2007UALA04731Valve · faultyFLIGHT DIVERTED TO YEG TO REMOVE AN ILL PASSENGER. THE AIRCRAFT DEVELOPED A MECHANICAL PROBLEM AND RETURNED TO SFO. REPLACED RT JET ISOLATION VALVE. OP CHK'D THRU MAINT ACCESS TERMINAL. PASSED, NO EXISTING FAULT. NO STATUS MSG.SDR 2007UALA04723Wire · burnedCREW REPORTED AN ELECTRICAL ODOR FROM REAR GALLEY AREA. RECIRC FANS AND GALLEY POWER TURNED OFF AND ODOR DISSIPATED. GALLEY AREA CHECKED AND NO OBVIOUS FAULTS FOUND. CHECKED FOR ODOR IN GALLEY CEILING AREA, UNDER FLOOR AND CHECKED WIRING IN AREA AND NO FAUSDR 2007UALA04743Lamp · inoperativeDOOR 4R EXTERIOR EMERGENCY LIGHT IS INOP. RELAMPED.SDR 2007UALA04711Wedge · damagedRIGHT MID FLAP TRAILING EDGE WEDGE IS CRUSHED AND CUT THROUGH. SUSPECTED TRAILING EDGE DAMAGED DURING GROUND MAINTENANCE. CATEGORY A REPAIR OF ACCOMPLISHED. NO FUTURE INSPECTION REQUIRED. AC OK FOR SERVICE.
SDR 2007UALA04710Skin · damagedNR 12 L/E SLAT LOWER SKIN NEAR MID HAS 6 INCH LONG CREASE. CUT OUT DAMAGE ON EXT SKIN AND INTERIOR NOSE BEAM, FABRICATED FILLER AND DOUBLER. INSTALLED REPAIR. AC OK FOR SERVICESDR 2007UALA04715Engine · fireNR 2 ENG FAILED TO START. FIRE NOTED IN TAILPIPE DURING ATTEMPT.SDR 2007UALA04696Lamp · inoperativeFOUND SEAT 2F AFT EMERGENCY LIGHT OUT. REPLACED LAMP ASSY.SDR 2007UALA04636Light · brokenEEL LIGHT STRIP IS BROKEN IN AFT GALLEY BY CART 400. REPLACED BROKEN LIGHT STRIP.SDR 2007UALA04673Engine · shutdownNR 1 ENGINE JUST SHUT DOWN ON TAXI OUT.SDR 2007UALA04637Charger · faultyAFTER BLOCKING OUT -MAIN BATTERY DISCHARGE- ADVISORY MESSAGE DISPLAY, WITH A -12 AMP DISCHARGE ON MAIN BATTERY. CYCLED STBY POWER SW ON OVERHEAD AND DISCHARGE DECREASED TO -2 AMP WITH 24 VDC ON MAIN BATTERY. REPLACED MAIN BATTERY CHARGER, OP CHECKED OK FOR SSDR 2007UALA04656Actuator · no testRAN RT FLAPERON POSITION TEST AND RESULT WAS FAILURE OF RT OTBD FLAPERON ACTUATOR TO ACHIEVE COMMANDED POSITION. RAN RIGHT FLAPERON POSITION TEST AND RESULT WAS FAILURE OF RH OTBD FLAPERON ACTUATOR TO ACHIEV E COMMANDED POSITION. INSTALLED NEW FLAPERON ACTUASDR 2007UALA04623Valve · malfunctionedFLIGHT DIVERTED DUE TO A WING ANTI-ICE PROBLEM THAT DEVELOPED EN ROUTE AND ASSOCIATED NON-ICING RESTRICTION WHICH PRECLUDED LANDING AT PLANNED DESTINATION. AFTER TROUBLESHOOTING FOUND BAD WING ANTI-ICE VALVE. SUSPECT DEBRIS PREVENTED FULL VALVE OPERATION.