Boeing 777-222

Service difficulty reports · 9,718

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '777222'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2007UALA02968Blade · damagedRTFL UNDER AMBER ALERT AFTER EXPERIENCING SURGE ON NR 2 ENGINE. ENGINE WAS REPLACED AT SFO. SHOP TEARDOWN FOUND HEAVY HPC BLADE DAMAGE THROUGHOUT THE COMPRESSOR. THE DAMAGE RESULTED FROM LIBERATION OF OF SEVERAL STAGE-6 VARIABLE STATOR VANE TRUNNION 'BUTTOAug 1, 2007 · N215UA · Boeing 777222 · Turbine Engine Compressor SectionSDR 2007UALA02965Circuit Board · faultedDET ZONE 1 CARGO AFT MESSAGE. REPLACED CARGO SMOKE DETECTOR. TESTED THRU THE MAINTENANCE ACCESS TERMINAL. NO MESSEGE FOUND GROUND TESTED NORMAL. SUSPECT ELECTRONIC CIRCUIT FAULT.Aug 1, 2007 · N791UA · Boeing 777222 · Smoke DetectionSDR 2007UALA02972Light · inoperativeNR 4R DOOR EXTERIOR EMERGENCY SLIDE LIGHT INOP. RELAMPED SLIDE LIGHT.Jul 30, 2007 · N210UA · Boeing 777222 · Emergency LightingSDR 2007UALA02910Light · inoperativeEEL LIGHTS INOP AT SEATS 2F AND 3F AFT LIGHTS ONLY. RESPLICED NEW EEL SYSTEM ASSY AT SEATS 2F AND 3F. SYSTEM OK CHECKED OK FOR SERVICE.Jul 28, 2007 · N782UA · Boeing 777222 · Emergency LightingSDR 2007UALA02909Oxygen Mask · leakingOXYGEN MASK PROBLEM CREW COMMENTS: F/O MASK HARNESS LEAKS WHEN HARNESS INFLATED. REPLACED FIRST OFFICER'S O2 MASK PER MM. SUSPECT LEAK DUE TO INFLATION CYCLING OF HARNESS.Jul 27, 2007 · N776UA · Boeing 777222 · Crew Oxygen SystemSDR 2007UALA02860Apu · odorSTRONG ELECTRICAL ODOR IN COCKPIT. [80-21-07] ACCOMPLISHED FIM 21-00 TASK 808 AND FOUND THE APU TO BE THE SOURCE OF THE ODOR IN THE FLT DECK AND CABIN. ACCOMPLISHED PACK BURN USING ENG BLEED TO OPERATE PACKS, OPS NORMAL NO DEFECTS NOTED. REPLACED BOTH OZJul 26, 2007 · N211UA · Boeing 777222 · Airborne Auxiliary Power Unit (APU) SystemSDR 2007UALA02839Fan · odorFA'S REPORTED FAINT ELECTRICAL ODOR IN CABIN. ODOR MAINLY NOTED BY FIRST CLASS GALLEY TO BUSINESS CLASS AREA. CREW NOTED UPPER RECIRC FAN STATUS MSG. [08-21-07] FOUND FWD UPPER RECIRC FAN C-B POPPED. :REPLACED UPPER RECIRC FAN PER MM 21-25-01. ALSO, REPLAJul 25, 2007 · N782UA · Boeing 777222 · Air Distribution FanSDR 2007UALA02805Unknown · unknownCENTER FUEL QUANTITY INOPERATIVE.Jul 23, 2007 · N787UA · Boeing 777222 · Aircraft Fuel SystemSDR 2007UALA02783Inverter · failedTHE 2E BOTH EEL LIGHTS INOPERATIVE. [08-14-07] TROUBLESHOOTING FOUND INVERTER FAILED, INSTALLED SERVICEABLE REF WDG25-25-21 SHT6. OPS CHECKED, SYS OPS NORMAL. RETURNED AC BACK TO NORM, OK FOR SERVICE.Jul 22, 2007 · N775UA · Boeing 777222 · Emergency LightingSDR 2007UALA02782Lamp · inoperativeTHE 9F FWD, 24C & 39G EEL LIGHTS ARE INOPERATIVE. [08-14-07] RELAMPED, AS PER MM33-51- 05, OPS CHECKED. SYS OPS NORMAL, RETURNED AIRCRAFT FOR SERVICE.Jul 22, 2007 · N775UA · Boeing 777222 · Emergency LightingSDR 2007UALA02758Tire · failedLEFT WING INBD FLAP LEADING EDGE AND LOWER SKIN SUSTAINED DAMAGED. [08-14-07] 1R MLG TIRE RECAP CAME OFF DURING TAKE OFF ROLL. DAMAGE TO PANELS 552CB, 551FB AND BULLNOSE OF LT INBD MID FLAP HAS DAMAGE REQUIRING GLASS LAYUP REPAIRED. WING INBD FLAP LEADINGJul 19, 2007 · N772UA · Boeing 777222 · TireSDR 2007UALA02748Oxygen System · reads lowFOUND CREW OXYGEN PRESSURE READING 710 PSI. [08-14-07] REPRESSURIZED CREW O2 CYLINDERS MANY TIMES. AFTER TROUBLESHOOTING, REPLACEMENT OF THE O2 MASK STOWAGE BOX RESOLVED PROBLEM. NO RECURRENCE. AIRPLANE OK FOR SERVICE.Jul 19, 2007 · N225UA · Boeing 777222 · Crew Oxygen SystemSDR 2007UALA02747Connector · mispinnedFWD BUSINESS CLASS CABIN HAS STRONG ELECTRICAL ODOR. [08-14-07] SUSPECT ONE OF ELEC UNIT UNDER SEAT ROW 9FED CREATED THE ODOR. DEACTIVATED ALL ELEC. UNIT AT THIS SEAT ROW. RECONNECTED VIDEO CONNECTIONS UNDER SEATS 8 DE&F, 9 DE&F, OPS CHECKED SYSTEM FOR ABOJul 19, 2007 · N218UA · Boeing 777222 · Communications System WiringSDR 2007UALA02699Light · inoperativeEEL LIGHT AT SEAT 33G IS INOPERATIVE. REPLACED LIGHT ASSY. OPS CHECKS GOOD.Jul 18, 2007 · N774UA · Boeing 777222 · Emergency LightingSDR 2007UALA02698Connector · unsecureAFT EMERGENCY EXIT LIGHT ON SEAT 2E INOP. SECURED CONNECTOR. OPS CHECKS GOOD.Jul 18, 2007 · N774UA · Boeing 777222 · Light System WiringSDR 2007UALA02694Unknown · unknownUNEVEN FUEL TANKS AND CTR SCAVENGE SYS CTR TANK APPEARS TO BE TRANSFERING TO RT MAIN IMMEDIATELY. LT MAIN QTY UNCHANGED AND RT INCREASES ABOUT 2.3 DURING 1ST 2 HRS. IT ONLY TRANSFERED WHEN CENTER PUMPS WERE ON AND APPEARED TO FILL RT TANK TO LIMIT. OPTED RIGJul 17, 2007 · N783UA · Boeing 777222 · Aircraft Fuel Distribution SystemSDR 2007UALA02701Light · brokenSEAT PROXIMITY EEL LIGHT BROKEN AT SEAT 37G. REPLACED PROXIMITY EEL LIGHT ASSY.Jul 17, 2007 · N214UA · Boeing 777222 · Emergency LightingSDR 2007UALA02700Radar · smokeFLIGHT CREW REPORTED SMOKE IN COCKPIT COMING FROM WX RADAR. PULLED C/B'S AND SMOKE DISSIPATED. [08-17-07] REPLACED WX RADAR CONTROL PANEL, BITE TEST OK. AIRPLANE RETURNED TO SERVICE.Jul 17, 2007 · N779UA · Boeing 777222 · Weather Radar SystemSDR 2007UALA02683Receptacle · fireFIRE AT EXTERNAL POWER RECEPTICLE WHILE EXTERNAL POWER CORD HOOKED UP. [08-17-07] REPLACED PRI EXTERNAL RECEPTACLE PER MM24-41-04, OP CHK WITH GROUND POWER, OP CHECKS GOOD. GROUND POWER CABLE HAD HIGH CURRENT SHORT WHERE RUBBER INSULATION HAD BROKEN DOWN ANJul 16, 2007 · N204UA · Boeing 777222 · External Power SystemSDR 2007UALA02657Lamp · inoperativeTHE 1F FWD, 3E AFT, 9F AFT & 17G EEL LIGHTS ARE INOPERATIVE. RELAMPED. BACK TO NORM, OK FOR SVC.Jul 15, 2007 · N773UA · Boeing 777222 · Emergency LightingSDR 2007UALA02660Ballast · overheatedLAV 100 MIRROR LIGHT ASSY SHOWED SIGNS OF OVERHEATING. [08-07-07] REPLACED LIGHT ASSY AND BALLAST. OP CK GOOD.Jul 15, 2007 · N783UA · Boeing 777222 · Passenger Compartment LightingSDR 2007UALA02658Connector · looseFIRE LOOP 2 APU. [08-07-07] FOUND CONNECTOR AT LUG LOOSE. SECURED LUG AFTER MEGGER OF ELEMENT. M26009. FIRE DET. TEST CHECKS NORMAL.Jul 14, 2007 · N777UA · Boeing 777222 · Fire Protection System WiringSDR 2007UALA02659Light · missingEXIT PATH LIGHT COVER 1E NOT ATTACHED. EEL STRIP MISSING.Jul 13, 2007 · N206UA · Boeing 777222 · Emergency LightingSDR 2007UALA02621Charger · faultyEICAS STATUS MESSAGES, APU BATTERY, APU BATTERY CHARGER. [08-07-07] REPLACED APU BATTERY AND APU CHARGER. AIRCRAFT READY FOR SERVICE.Jul 13, 2007 · N796UA · Boeing 777222 · Airborne Auxiliary Power Unit (APU) SystemSDR 2007UALA02560Cover · damagedCOVER AT 24D HAS SHARP EDGE AT PAX FEET. [08-08-07] REPOSITIONED COVER PLATE AT SEAT 24D. NO LONGER HAS SHARP EDGE AT CONTACT POINT. OPERATES SATISFACTORIALLY.Jul 11, 2007 · N769UA · Boeing 777222 · Fuselage Miscellaneous StructureSDR 2007UALA02553Line · leakingNR 2 ENGINE HAS FIRE DAMAGE FROM FUEL LEAKING AT THE MAIN FUEL SUPPLY HOSE AT THE NACELLE DISCONNECT PANEL. FIRE NOT CONFIRMED. ECM DATA SHOWED UNDER COWL TEMPERATURES TO BE NORMAL. HOWEVER, THERE WAS DAMAGE DUE TO A FUEL LEAK IN THE AREA. DAMAGE WAS FOUNDJul 10, 2007 · N783UA · Boeing 777222 · Engine Fuel DistributionSDR 2007UALA02563Light · inoperativeBOTH EEL LIGHTS AT SEAT 1E ARE INOP. [07-27-07] REPLACED BOTH EEL STRIPS, OPS CK OK.Jul 10, 2007 · N797UA · Boeing 777222 · Emergency LightingSDR 2007UALA02562Overheat Loop · failedBLEED LOOP 1 WING R FAILURE OF RIGHT WING DUCT LEAK DETECTION LOOP OR CENTER DUCT LEAK OVERHEAT DETECTION SYSTEM (DLODS) CARD. [08-08-07] CHECKED FOR DUCT LEAK RH AC PACK-BAY AREA. ALSO CHKED FOR DAMAGE OF SENSOR ELEMENTS. ALL SENSORS ARE OK. UNABLE TO DUPLIJul 10, 2007 · N219UA · Boeing 777222 · Overheat DetectionSDR 2007UALA02561Light · missingEEL LIGHT ON SIDE OF SEAT 1E MISSING. [07-27-07] REPLACED LIGHT ASSY.Jul 10, 2007 · N780UA · Boeing 777222 · Emergency LightingSDR 2007UALA02525Indicator · inoperativeFUEL QTY INDICATOR BLANKING. [08-08-07] ACCOMPLISHED TANK ENTRY & REPLACED FUEL PROBES. NR 3 RT CENTER AND NR 3 LT CENTER. RT MAIN NR 19 AND 20. AND LT MAIN NR 19 AND NR 20 PE. CHECKED VALUES AFTER INSTALLATION AND ALL ACCEPTABLE. AIRCRAFT READY FOR SERVJul 10, 2007 · N774UA · Boeing 777222 · Fuel Quantity IndicatorSDR 2007UALA02528Circuit Card · faultyFIRE LOOP 2 ENG R STATUS MESSAGE. REPLACED CIRCUIT CARD.Jul 9, 2007 · N781UA · Boeing 777222 · Fire DetectionSDR 2007UALA02514Oxygen Bottle · reads lowCREW O2 LOW 300 PSI. [08-08-07] REMOVED AND REPLACED CREW O2 BOTTLE, LEAK CHK OK. AIRCRAFT RETURNED TO SERVICE.Jul 8, 2007 · N781UA · Boeing 777222 · Crew Oxygen SystemSDR 2007UALA02513Stringer · damagedDAMAGE REPORTED BY CATERING TRUCK ADJACENT TO R2 DOOR. DAMAGE IS AT STA 793, ON STRINGER S-33R. [08-08-07] DOUBLER INSTALLED & INSPECTED. AIRCRAFT OK FOR SERVICE. DAMAGE CAUSED BY CONTACT WITH CATERING TRUCK.Jul 6, 2007 · N781UA · Boeing 777222 · Fuselage Main, Longeron/StringerSDR 2007UALA02449Slide · damagedLARGE SLIT DOWN BOTTOM TUBE APPROXIMATELY 2 TO 2.5 FEET IN LENGTH. [08-08-07] OPERATIONALLY CHECKED EMERGENCY ESCAPE SLIDE AT DOOR 4L 649-9016 MR25718 PER MM 25-66-00, PAGE SERIES 501. AFTER COMPLETION, SIGN-OFF USING NR DATA. SLIDE DID NOT DEPLOY PROPJul 5, 2007 · N219UA · Boeing 777222 · Escape SlideSDR 2007UALA02409Cooling Fan · dirtyEXPERIENCED ODOR OF SMOKE. SOURCE DETERMINED TO BE FAILED COOLING FAN. CONTINUED TO DESTINATION. [07-27-07] REPLACED EQUIPMENT COOLING FAN AND RESTORED P210 ELMS CARD. OPS CHECKED NORMAL. SUSPECT DIRT ACCUMULATED IN STATOR & SHORTED THE MOTOR.Jul 4, 2007 · N792UA · Boeing 777222 · Air Distribution FanSDR 2007UALA02377Oven · fumesFLIGHT DIVERTED DUE TO FUMES COMING FROM A BUSINESS CLASS OVEN. [07-27-07] FOUND ODOR TO BE STRONGEST IN MID GALLEY AREA. APPEARED TO BE ACIDY SMELL. WHEN WARMING OVEN W33 WAS OPENED, ODOR BECAME MUCH STRONGER. FOUND PAPER TOWEL AND RESIDUE OF MELTED PLASTJul 2, 2007 · N209UA · Boeing 777222 · Buffet/GalleysSDR 2007UALA02363Light · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 1R IS OUT. [07-27-07] RELAMPED. OPS CHECKED NORMAL.Jul 1, 2007 · N220UA · Boeing 777222 · Emergency LightingSDR 2007UALA02362Light · inoperativeTHE 2E AFT & 35C EEL LIGHTS ARE INOPERATIVE. [07-27-07] RELAMPED. SYS OPS NORMAL.Jul 1, 2007 · N220UA · Boeing 777222 · Emergency LightingSDR 2007UALA02359Slat · damagedRIGHT WING MOST OUTBOARD L/E SLAT 14 IS DAMAGED. [07-27-07] REMOVED NR 14 SLAT AND INSTALLED SERVICABLE SURFACE PER 27-81-15. ACCOMPLISHED TEST FLIGHT. AIRCRAFT TESTS OK & IS READY FOR SERVICE. SUSPECT SLAT IMPACTED BY GROUND EQUIPMENT.Jun 29, 2007 · N213UA · Boeing 777222 · Leading Edge DevicesSDR 2007UALA02358Light · inoperativeTHE 8D FWD, 11F FWD, 12F FWD, 19G AND 34C EEL LIGHTS ARE INOPERATIVE. RELAMPED EMERGENCY LIGHTS. OPS CHECKS GOOD.Jun 29, 2007 · N778UA · Boeing 777222 · Emergency LightingSDR 2007UALA02357Windshear Sys · inoperativeWXR SYS WXR DISPLAY IS NOT PRESENT WHEN WXR SELECTED ON EFIS CONTROL PANEL. WINDSHEAR SYS EITHER PREDICTIVE OR REACTIVE WINDSHEAR ALERTING FUNCTIONS ARE FAILED SUCH THAT WINDSHEAR ALERTING CAPABILITY IS REDUCED OR NOT AVAILABLE. A REACTIVE WINDSHEAR FAILURE Jun 29, 2007 · N774UA · Boeing 777222 · Wind Shear Detection SystemSDR 2007UALA02356Battery Pack · unreliableDOOR 2L EPAS BATTERY PACK -DATE LAST SERVICED OR MFG- IS UN-READABLE. [07-27-07] REPLACED DOOR 2L EPAS BATTERY PACK. AIRCRAFT READY FOR SERVICE.Jun 29, 2007 · N769UA · Boeing 777222 · Emergency LightingSDR 2007UALA02269Elbow · crackedFLIGHT DIVERTED DUE TO A HYDRAULIC INDICATION PROBLEM. HYD LEAK ON NR 1 PYLON. FOUND CRACKED ELBOW MS21907W10, NON STOCK PART AVAILABLE AT BOEING. REPLACED ELBOW. SERVICED HYD SYSTEM. LEAK CHECK OK WITH ENG MOTORING, NO LEAKS NOTED. AIRCRAFT RETURNED TO Jun 27, 2007 · N792UA · Boeing 777222 · Hydraulic System, MainSDR 2007UALA02227Unknown · odorBURNING SMELL IN CABIN ON ARRIVAL. INBOARD CABIN CREW REPORTED BURNING SMELL IN AFT SIDE CABIN AFTER LANDING. CHECKED NO CIRCUIT BREAKERS POPPED IN AFT GALLEY. ALSO CHECKED AFT CABIN AREA WITH CEILING PANEL REMOVED, CONDITION NORMAL. CABIN AND LAV LIGHTINGJun 25, 2007 · N217UA · Boeing 777222 · Buffet/GalleysSDR 2007UALA02179Valve · leakingUNWANTED FUEL TRANSFER FROM CENTER TANK TO RIGHT MAIN TANK. *S/D* AFTER EXTENSIVE TROUBLESHOOTING AND REPLACEMENT OF LEFT REFILL VALVE CONTROLLER DIDN'T SOLVE PROBLEM. REPLACED LEFT MAIN AFT PUMP DISCHARGE CK VALVE PER MM 28-22-08. OPS CHECK GOOD.Jun 23, 2007 · N204UA · Boeing 777222 · Fuel Boost PumpSDR 2007UALA02214Light · inoperativeEMERGENCY LIGHT IN AFT GALLEY AT FLOOR LEVEL CTR POST IS OUT. RELAMPED. OPS CHECKS GOOD .Jun 22, 2007 · N221UA · Boeing 777222 · Emergency LightingSDR 2007UALA02215Battery · faultyFOUND MAIN BATTERY AT 17V AND DISCHARGING AT 4A. [07-20-07] REPLACED MAIN BATTERY PER MM24-31-01. TESTS OK FOR RETURN TO SERVICE.Jun 22, 2007 · N227UA · Boeing 777222 · Battery/Charger SystemSDR 2007UALA02213Light · inoperativeEMERGENCY LIGHT AT SEAT 3E AFT LIGHT IS OUT. RELAMPED. OPS CHECKS GOOD.Jun 22, 2007 · N221UA · Boeing 777222 · Emergency LightingSDR 2007UALA02158Charger · failedMAIN BATTERY MAIN BATTERY CHARGER FAILURE. [07-17-07] REPLACED MAIN BATTERY AND ELMS CARD. OP CHECKED OK FOR SERVICE.Jun 22, 2007 · N227UA · Boeing 777222 · Battery/Charger SystemSDR 2007UALA02169Extinguisher · unserviceableWATER EXTINGUISHER-DOOR 1R MISSING SAFETY WIRE. [07-20-07] REPLACED EXTINGUISHER WITH SERVICABLE ONE. AIRCRAFT OK FOR RETURN TO SERVICE.SUSPECT SAFETY WIRE SNAGGED BY PASSENGER SERVICE EQUIPMENT AND BROKEN OFF.Jun 21, 2007 · N795UA · Boeing 777222 · Fire Bottle, Portable
Back to Boeing 777-222