Boeing DHC-8-102

Service difficulty reports · 9,272

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DHC8102'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HNAA2013022500094Bulb · failedOVERHEAD EMERGENCY LIGHT AT ROW 5 IS INOP. R & R OVERHEAD EMERGENCY LIGHT AT ROW 5. OPS CHECKED GOOD.Feb 25, 2013 · N837EX · Dhav DHC8102 · Emergency LightingSDR HNAA2013022500093Bulb · failed17TH AND 21ST FLOOR EMERGENCY LIGHTS ARE INOPERATIVE. R & R BULBS IN FLOOR EMERGENCY LIGHTS. OPS CHECKED GOOD.Feb 25, 2013 · N934HA · Dhav DHC8102 · Emergency LightingSDR HNAA2013022500092Bulb · inoperativeLAST CEILING EMERGENCY LIGHT IS INOPERATIVE. R & R EMERGENCY CEILING LIGHT, OPS CHECKED GOOD.Feb 25, 2013 · N934HA · Dhav DHC8102 · Emergency LightingSDR HNAA2013022500091Control Box · intermittentALL EMERGENCY LIGHTS ILLUMINATED INTERMITTENTLY. MX INSPECTED BOTH BRUSH BLOCKS AND ADJACENT WIRE HARNESS. NO DEFECTS NOTED. GROUND RAN ACFT AND COULD NOT DUPLICATED. R & R EMERGENCY LIGHT CONTROL BOX FOR MX CONVENIENCE. OPS CHECKED GOOD IAW 33-51-00. OK Feb 25, 2013 · N914HA · Dhav DHC8102 · Emergency LightingSDR CA130226003Hose · leaking(CAN) ON CLIMB, THE FLIGHT CREW NOTICED 1 OF THE TAIL DE-ICE BOOTS WAS NOT INFLATING. THE WEATHER AT THE DESTINATION WAS SNOW AND FLIGHT WOULD ENCOUNTER ICING CONDITIONS. ACFT RETURNED TO BASE FOR MAINTENANCE ACTION. A LEAKING HOSE IN THE REAR FUSELAGE WAS FOFeb 23, 2013 · Dhav DHC8102 · Airfoil Anti/De-ice SystemSDR HNAA2013022200089Bulb · burned outEMERGENCY EXIT DOOR LIGHTS HAS ONE BULB OUT. REPLACED BULB IAW AMM 33-52-00.Feb 22, 2013 · N931HA · Dhav DHC8102 · Emergency LightingSDR HNAA2013022200088Connector · dirtyNR 2 STANDBY HYD SYS PRESSURE DROPPED AND CIRCUIT BREAKER TRIPPED FOR NR 2 STBY PUMP. RESET CIRCUIT BREAKER, GROUND RAN ACFT, CLEANED NR 2 STBY PUMP CONNECTOR AND R & R CIRCUIT BREAKER FOR NR 2 STBY PUMP. OPS CHECKED GOOD IAW 29-11-17.Feb 21, 2013 · N808EX · Dhav DHC8102 · Hydraulic Power System WiringSDR HNAA2013022000083Sill · corrodedSURFACE CORROSION ON DOOR SILL AT GALLARY DOOR AREA. LIGHTLY BLENDED ON DOOR SILL. REMOVED TWO SMALL AREAS OF LIGHT CORROSION, ALODINED AND PRIMED.Feb 20, 2013 · N326EN · Dhav DHC8102 · Fuselage Miscellaneous StructureSDR HNAA2013021900080Relay · failedLT AC BUSS FAILURE IN FLIGHT WITH EMERGENCY LIGHTS FLICKERING. ALSO ASSOCIATED CAUTION LIGHTS ON. R & R 2421-S2 AND 2421-K2. RAN ENGINES FOR OVER 10 MINUTES. OPS CHECKED ALL AC POWER RELATED SYS. NO DISCREPENCIES NOTED AT THIS TIME.Feb 19, 2013 · N907HA · Dhav DHC8102 · AC Power Distribution SystemSDR HNAA2013021900082Bulb · failedSECOND EMERGENCY FLOOR LIGHT IS INOPERATIVE. R & R EMERGENCY FLOOR LIGHT. OPS CHECKED GOOD. RESECURED LENS.Feb 19, 2013 · N938HA · Dhav DHC8102 · Emergency LightingSDR HNAA2013021900081Bulb · weakSIDE WALL EMERGENCY EXIT SIGN IS DIM AT PAX DOOR. R & R BULBS IN SIDE WALL EMERGENCY EXIT SIGN. OPS CHECKED GOOD.Feb 19, 2013 · N839EX · Dhav DHC8102 · Emergency LightingSDR HNAA2013021900079Warning Light · false activationON ROTATION, RECEIVED A LT ELEVATOR HORN HEAT CAUTION LIGHT. SWITCHED LT ELEVATOR HORN HEAT SWITCH TO ALT POSITION. OPS CHECKED GOOD.Feb 19, 2013 · N808EX · Dhav DHC8102 · Central WarningSDR HNAA2013021900077Wire · brokenAFTER GEAR EXTENSION, CREW HEARD A SINGLE POP NOISE, THEN AFTER ROLL OUT, WHEN FLAPS WHERE SELECTED TO 5 DEGREES FROM 15 DEGREES, FLAPS DID NOT MOVE. BUT WHEN ZERO WAS SELECTED, THE FLAPS RETRACTED FULLY. MOVING FLAP SELECTOR TO ZERO, A RESISTANCE WAS FELT.Feb 19, 2013 · N943HA · Dhav DHC8102 · Flight Control System WiringSDR CA130220002Sequence Valve · failed(CAN) ON DEPARTURE WHEN THE GEAR WAS SELECTED UP, THERE WAS A LOUD BANG FROM THE NOSE GEAR AREA. THE GEAR WOULD NOT RETRACT AND NUMEROUS HYD SERVICES CAUTION LIGHTS CAME ON INCLUDING THE NR 2 HYD ISO VALVE. THE NR 2 HYDRAULIC QTY HAD RAPIDLY DROPPED TO 0.6 QTFeb 18, 2013 · Dhav DHC8102 · Nose/Tail Landing GearSDR CA130221002Relay · failed(CAN) ON CLIMBOUT, THE LEFT PROP DE-ICE CIRCUIT BREAKER POPPED. FLIGHT HAS RETURNED TO BASE, LANDED SAFELY AND WAS REMOVED FROM SERVICE FOR TROUBLESHOOTING. A CONTINUITY CHECK ON THE LT BRUSH BLOCK AND SLIP RINGS, NO FAULT FOUND. 115 VOLT AC POWER TO PHASE AFeb 17, 2013 · Dhav DHC8102 · Propeller/Rotor Anti-Ice/De-Ice SystemSDR HNAA2013021500059Socket · burnedSTRONG ELECTRICAL ODOR COMING FROM REAR OF CABIN OVERHEAD LIGHT AT ROW 7AC SOCKET BURNED. DE-ACTIVATED CABIN INTERIOR NORMAL LIGHT SYS IAW SPECIAL PRECEDURE 33.1. FOUND O/H LIGHT SOCKET BURNED AT ROW 7AC. REMOVED AND REPLACED LIGHT SOCKET AND BALLAST AT ROW Feb 15, 2013 · N810EX · Dhav DHC8102 · Passenger Compartment LightingSDR HNAA2013021500076Retainer · crackedLT NACELLE EXHAUST SHROUD SEAL RETAINER IS CRACKED. REPAIRED SEAL RETAINER IAW DWG 85411375.Feb 15, 2013 · N975HA · Dhav DHC8102 · Engine Collector/Tailpipe/NozzleSDR HNAA2013021500075Seat Track · corrodedCORROSION FOUND ON LT AND RT INBD SEAT TRACK DEFLECTOR BETWEEN STA X260 AND X387. REPAIRED DEFLECTOR FOR LT AND RT INBD SEAT TRACK IAW SRM 51-42-05Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2013021500074Seat Track · corrodedRT INBD SEAT TRACK IS CORRODED AT STA 219 TO X240. REPAIRED RT SEAT TRACK IAW RD8-53-3074 AND DWG 85320490. ALODINE AS REQUIRED.Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2013021500073Angle · crackedRT NACELLE FINGERNAIL OTBD LOWER AFT HEAT SHIELD ANGLE IS CRACKED. R & R LOWER AFT ANGLE IAW SRM 51-42-05.Feb 15, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon Miscellaneous StructureSDR HNAA2013021500072Bracket · crackedGENERATOR INTAKE COOLING BRACKET IS CRACKED ON RT ENGINE COWLING PANEL 424AR. REPAIRED INNER SKIN OF RT ENGINE COOLING DUCT BRACKET IAW EA16-2013-037 AND E08-71-13-0034.Feb 15, 2013 · N975HA · Dhav DHC8102 · Engine Cowling SystemSDR HNAA2013021500071Bracket · crackedRT ENGINE COWLING GEN COOLING INTAKE DUCT BRACKET IS CRACKED. REPAIRED RT ENGINE COWLING PANEL 424AR IAW EO8-71-13-0073, EA09-2013-019.Feb 15, 2013 · N975HA · Dhav DHC8102 · Engine Cowling SystemSDR HNAA2013021500070Hinge · crackedCARGO ARTICULATED PANEL HINGE IS CRACKED. R & R HINGE PANEL FOR CARGO ARTICULATED PANEL.Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage Main, StructureSDR HNAA2013021500069Channel · crackedANGLE FOUND CRACKED ON FRAME STA X545, STR 16 AND STR 22. REPLACED CHANNEL ASSY ON FRAME BETWEEN STRINGERS 16 AND 22, AT STA X545 IAW SRM 51-42-05Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage Miscellaneous StructureSDR HNAA2013021500068Angle · crackedLEFT INBD AND OTBD UPPER ANGLE IS CRACKED. REPAIRED BOTH LT AND RT UPPER ANGLES IAW SRM 51-42-45.Feb 15, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon Miscellaneous StructureSDR HNAA2013021500067Stiffener · crackedTWO STIFFENERS AND ONE CHANNEL WAS FOUND CRACKED ON RT NACELLE HEAT SHIELD. REPAIRED STIFFENERS AND CHANNEL ON RT NACELLE HEAT SHIELD AD IAW RD8-54-1153 AND RD8-54-3195.Feb 15, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon Miscellaneous StructureSDR HNAA2013021500066Seat Track · corrodedLEFT AND RIGHT INBD SEAT TRACK FROM STA X182 TO X526 HAVE LIGHT SURFACE CORROSION. REPAIRED LT SEAT RAIL, INBD FROM STA X182 TO X526 IAW RD8-53-1339. REPAIRED RT INBD SEAT TRACK IAW RD8-53-1339. HFEC INSPECTION WAS COMPLIED WITH. NO DEFECTS FOUND.Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2013021500065Angle · crackedLT FORWARD CLOSING ANGLE IS CRACKED. R & R CLOSING ANGLE IAW SRM 51-40-10, SRM 51-42-45, SRM 51-42-05, RD8-51-0015 AND RD8-51-0102.Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage Miscellaneous StructureSDR HNAA2013021500064Bracket · crackedRT SHROUDED BLEED PIPE LOWER BRACKET IS CRACKED. REPAIRED RT LOWER BRACKET FOR BLEED PIPE SHROUD IAW SRM 51-42-05.Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage Main, Attach FittingsSDR HNAA2013021500063Threshold · corrodedPAX DOOR THRESHOLD IS CORRODED ON TOP AND BOTTOM SURFACE. R & R PAX DOOR THRESHOLD ASSY IAW SRM 61-42-05.Feb 15, 2013 · N975HA · Dhav DHC8102 · Fuselage Miscellaneous StructureSDR HNAA2013021500062Battery · failedEMERGENCY FLOOR PATH LIGHT AT 1ST AND 2ND POSTION FROM FRONT IS INOP. R & R EMERGENCY LIGHT BATTERY AT POSTION 3352-PS2 IAW 33-51-00. OPS CHECKED GOOD.Feb 15, 2013 · N806EX · Dhav DHC8102 · Emergency LightingSDR HNAA2013021500061Bulb · failed12TH EMERGENCY FLOOR PATH LIGHT IS INOPERATIVE. R & R BULB FOR EMERGENCY FLOOR PATH LIGHT. OPS CHECKED GOOD.Feb 15, 2013 · N907HA · Dhav DHC8102 · Emergency LightingSDR HNAA2013021500060Indicator · out of adjustNR 2 PROPELLER RPM AT 1225 ON TAKEOFF ROLL. ALL OTHER INDICATIONS NORMAL. ADJUSTED NR 2 SPEED TRIM SCREW 1/8 TURN COUNTER CLOCKWISE IAW MM 61-22-00. GROUND RAN ACFT. PROP SPEED WITHIN LIMITS.Feb 15, 2013 · N937HA · Dhav DHC8102 · Propeller AssemblySDR HNAA2013021500058Unknown · warning lightRT AC BUSS CAUTION LIGHT ILLUMINATED IN FLIGHT WITH ASSOCIATED CAUTION LIGHTS. PROBLEM OCCURED TWO MINUTES AFTER SELECTING PROP HEAT ON. ON PREVIOUS THREE LEGS, NO AC BUSS CAUTION LIGHT WITH PROP HEAT SELECTED OFF. R & R 2421-S2. R & R 2421-K2. RAN ENGINEFeb 15, 2013 · N907HA · Dhav DHC8102 · Electrical Power SystemSDR HNAA20130200057Diaphragm · crackedDIAPHRAGM IS CRACKED ON RT FINGERNAIL AT STA XN215, OTBD LOWER CORNER. R & R DIAPHRAGM IAW STRUCTURAL REPAIR MANUAL 51-42-051.Feb 14, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon, Main FrameSDR HNAA2013021400056Drag Angle · crackedLT NACELLE TO WING INBD DRAG ANGLE IS CRACKED. REPAIRED LT DRAG ANGLE IAW RD8-57-1053 AND RD8-51-0015. HIGH FREQUENCY EDDIE CURRENT WAS COMPLIED WITH IAW RD8-57-1053. NO DEFECTS NOTED.Feb 14, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon, Main FrameSDR HNAA2013021400055Drag Angle · crackedRT NACELLE TO WING OTBD DRAG ANGLE WAS FOUND TO BE CRACKED. REPAIRED DRAG ANGLE IAW EA 16-2013-042. HIGH FREQUENCY EDDIE CURRENT WAS COMPLIED WITH IAW EA 16-2013-042. NO DEFECTS FOUND.Feb 14, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon, Main FrameSDR HNAA2013021400054Release Cable · chafedLEFT NACELLE MLG EMERGENCY RELEASE CABLE IS CHAFED AND CORRODED. R & R EMERGENCY RELEASE CABLE IN LT NACELLE IAW AMM32-35-00.Feb 14, 2013 · N975HA · Dhav DHC8102 · Landing Gear Retraction/Extension SystemSDR HNAA2013021400053Structure · crackedLEFT NACELLE FWD DOOR OPENING, OTBD CORNING IS CRACKED. STOP DRILLED AND TRIMMED AWAY CRACK, FILLED AND SEALED IAW RD8-54-119.Feb 14, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon, Main FrameSDR HNAA2013021300052Bulb · failedTERRAIN CAUTION LIGHT FOR DISARM LIGHT IS INOPERATIVE. R & R CAUTION LIGHT. RESECURED LENS. OPS CHECKED GOOD.Feb 13, 2013 · N942HA · Dhav DHC8102 · Central WarningSDR HNAA2013021100049Bulb · malfunctionedFORWARD AFT EMERGENCY SIGN LIGHT IS DIM. REMOVED BULBS AT LOWER RT EMERGENCY SIGNS. OPS CHECKED GOOD.Feb 11, 2013 · N935HA · Dhav DHC8102 · Emergency LightingSDR HNAA2013021100048Bulb · failedEMERGENCY LIGHT SWITCH BACKLIGHT IS INOP. R & R BULB. OPS CHECKED GOOD.Feb 11, 2013 · N808EX · Dhav DHC8102 · Emergency LightingSDR HNAA2013021100046Unknown · unknownON CLIMB OUT, LT AC BUSS, LT TRU AND LT ELEVATOR HORN HEAT CAUTION LIGHTS ILLUMINATED. RETURN TO FIELD. INSPECTED BOTH 1 AND 2 ENGINES PROP BRUSH BLOCKS AND CLEANED CONNECTOR PLUGS AS WELL. INSPECTED BOTH ENGINES PROP HEATER LEADS. NO DEFECTS NOTED. GROUNFeb 11, 2013 · N907HA · Dhav DHC8102 · Central WarningSDR HNAA2013021100045Brush Block · saturatedON CLIMBOUT, RT AC BUSS, RT TRU AND RT ELEVATOR HORN HEAT CAUTION LIGHTS CAME ON. STAYED ON FOR ENTIRE FLIGHT. NR 2 BRUSH BLOCK WAS OILED SOAKED. R & R NR 2 PROP BRUSH BLOCK. OPS CHECKED GOOD. OPS CHECKED IAW WC 24-20-04Q. BUS CONTACTOR OPS CHECKED NORMALFeb 11, 2013 · N907HA · Dhav DHC8102 · Ice/Rain Protection System WiringSDR HNAA2013021100044Radar · faultedWEATHER RADAR IS INOPERATIVE, SHOWS ANT FAULT MESSAGE. ACFT RETURNED TO FIELD. R & R RADAR R/T. OPS CHECKED GOOD IAW MANUAL 34-41-02. OPS CHECKED GOOD. NO DEFECTS NOTED. OK FOR SERVICE.Feb 11, 2013 · N911HA · Dhav DHC8102 · Weather Radar SystemSDR HNAA2013021100043Generator · inoperativeON CLIMB OUT, RT AC BUSS, RT TRU AND RT ELEVATOR HORN HEAT CAUTION LIGHTS ILLUMINATED. ACFT WAS AIR TURNBACK. R & R NR 2 AC GENERATOR, GCU IAW WC 24-20-11R. OPS AND LEAK CHECKED GOOD.Feb 11, 2013 · N907HA · Dhav DHC8102 · AC Generator-AlternatorSDR HNAA2013020800042Stiffener · crackedTWO STIFFENERS AND ONE CHANNEL WAS FOUND CRACKED ON RT NACELLE SHIELD. FABRICATED HEAT SHIELD IAW RD 8-54-1153 AND RD8-54-3195.Feb 8, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon Miscellaneous StructureSDR HNAA2013020800041Structure · crackedLEFT ENGINE COWL OPENING IS CRACKED, XN 125.50. HFEC INSPECTION WAS DONE IAW RD8-54-1315. NO DEFECTS NOTED.Feb 8, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon, Main FrameSDR HNAA2013020800040Structure · corrodedNR 2 NACELLE AFT ID CORRODED. REPAIRED RT AFT ID IAW RD8-54-020. NO DEFECTS NOTED.Feb 8, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon Miscellaneous StructureSDR HNAA2013020800039Drag Angle · crackedRT NACELLE TO WING OTBD DRAG ANGLE WAS FOUND CRACKED. DRAG ANGLE WAS REPAIRED IAW EA 16-2013-042. COMPLIED WITH HFEC INSPECTION. REINSTALLED ACCES SKIN PANEL IAW RD8-51-0015 AND SRM 51-42-05.Feb 8, 2013 · N975HA · Dhav DHC8102 · Nacelle/Pylon, Main Frame
Back to Boeing DHC-8-102